INSTALLATION INSTRUCTIONS AND SPECIFICATIONS: COOLING COIL

Similar documents
RCTA Horizontal Evaporator Coil Installation Instructions

Evaporator Coil. Installation Instructions GENERAL

Evaporator Coil. Installation Instructions GENERAL

PL Series Premier Indoor Plenum Coils

Upflow/Downflow A-Coil Specifications

EL SERIES INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP

INSTALLATION INSTRUCTIONS TXV Coils EDM, EDD, EDA

Aluminum Cased Heat Pump / Cooling Coils 2-5 Ton

INSTALLATION INSTRUCTIONS TXV Coils EBU, EBA

INSTALLATION INSTRUCTIONS TXV Coils EBD, EBA

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP MODELS: TABLE OF CONTENTS LIST OF FIGURES

HIGH EFFICIENCY AIR HANDLER

Use the information in this manual for the installation / servicing and keep the document near the furnace for future reference.

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions Replacement R-22 A-Coil Model RCTA- 8060

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

SMART DUCT SYSTEM. Caution: Do not tamper with the unit or its controls. Call a qualified service technician.

Installation Instructions

AIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY UIM-C-0214

Cased Aluminum "Convertible" Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC**

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

RE9X Series Downflow, Upflow Electric Furnaces

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

INSTALLATION INSTRUCTIONS

Installation Instructions

Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

INSTALLATION INSTRUCTIONS

Installation Instructions

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

Installation Instructions

INSTALLATION INSTRUCTIONS

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

Ruud High Efficiency Air Handler

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY

2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

HIGH EFFICIENCY AIR HANDLER

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

Rheem High Efficiency Air Handler

FEM4X. Product Specifications FAN COILS /14/15

INDOOR COILS INDOOR COILS. Airflow Capacities 400 to 2,250 CFM [188.8 to L/s] FORM NO. C REV. 14 Supersedes Form No. C Rev.

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION INSTRUCTION

Installation Instructions

INSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC LIST OF SECTIONS LIST OF FIGURES

Uncased Vertical Aluminum Upflow Cooling/HP Coils 2-5 Ton 4PXA. Heat Pump / Cooling Coils for R-410A PUB. NO

Rheem High Efficiency Air Handler

Premier Dealer Collection Dealer Guide. Trane American Standard. The ADP Advantage...

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

INSTALLATION MANUAL WARNING WARNING FULL-CASED UPFLOW/COUNTERFLOW FOR COOLING/HEAT PUMPS FULL-CASED MULTI-POSITION FOR COOLING/HEAT PUMPS MODELS: CF

FG7T (C and L Series)

Installation Instruction

E3EB-xxx-H Series Downflow, Upflow Electric Furnaces

Ruud Standard Efficiency Air Handler

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

Installation Instructions

E4EB-xxx-H Series Downflow, Upflow Electric Furnaces

INSTALLATION INSTRUCTION

Installation Instructions

Ruud Standard Efficiency Air Handler

RIGHT-SIZED SYSTEM SMART DUCT SYSTEM

PACKAGE AIR CONDITIONER

INSTALLATION INSTRUCTIONS FOR RCQD COILS

UPFLOW/DOWNFLOW COILS

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Product Data. Fig. 1 - Unit 50VR -A

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

Contents INDEX. TDM Series Indirect Fired Heaters

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor

! WARNING: FIRE OR EXPLOSION HAZARD. Applies to: Model SC, Separated-Combustion Duct Furnace. Model SC INSTALLATION / OPERATION / MAINTENANCE

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

INSTALLATION INSTRUCTIONS

PT9 SERIES DOWNFLOW/HORIZONTAL 2-STAGE NATURAL GAS FURNACE (90%) (STYLE A)

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

E3EH-xxx-H Series E3EB-xxx-H Series

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER

Rheem Standard Efficiency Air Handler

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

Gas-Fired Indoor and Outdoor Duct Furnaces

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

FC9V SERIES 2-STAGE CONDENSING VARIABLE SPEED UPFLOW NATURAL GAS FURNACES (STYLE C)

Wt. Lbs Model Number (BTUH) Hz

E2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits

FC9V SERIES - UPFLOW 2-STAGE CONDENSING VARIABLE SPEED NATURAL GAS FURNACES (STYLE A)

CHINOOK WARM AIR GAS FURNACE DESIGNED, ENGINEERED AND MANUFACTURED IN CANADA INCLUDING COMPONENTS MADE IN THE USA

Installer s Guide Convertible Air Handlers 1-1/2 5 Ton

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560)

Transcription:

INSTALLATION INSTRUCTIONS AND SPECIFICATIONS: COOLING COIL VERTICAL AND MULTIPOSITION COOLING COIL FOR CHINOOK AND SUPREME Models: CC1.0-10.0-M CC1.5-13.5-V & CC1.5-13.5-M CC2.5-13.5-V & CC2.5-13.5-M CC2.5-15.7-V & CC2.5-15.7-M CC3.0-15.7-V & CC3.0-15.7-M CC3.0-21.0-V & CC3.0-21.0-M CC1.5-S-V & CC1.5-S-M CC2.5-S-V & CC2.5-S-M CC3.0-S-V & CC3.0-S-M Printed in Canada on 100% recycled paper 2018-04-11 X40249 Rev.A

Table of content 1 GENERAL 2 1.1 Vertical........................................................................ 2 1.2 Multi-position..................................................................... 2 2 METERING DEVICE 2 List of figures Figure 1: Multi-position configuration........................................ 4 Figure 2: Coil dimensions.............................................. 5 List of tables Table 1: Performances............................................... 3 Table 2: Specifications............................................... 3 1

1.2 Multi-position 1 GENERAL Our coils are designed to be used with our Alizé heat pump outdoor unit. These instruction are intended as a general guide and do not supersede local codes in any way. Consult with local authorities having jurisdiction before installation. Read this manual and all safety messages prior to installing the evaporator coil. Check coil for shipping damage and verify the contents of the box containing the evaporator coil. If you should find damage, immediately contact the last carrier. Check the Alizé installation guide (X40228) for proper line sizing. Coils are shipped with a 10 psi dry air holding charge. Puncture rubber plug on suction line to release charge before removing plugs. The absence of pressure does not verify a leak. Check the coil for leaks before installing or returning it to your wholesaler. For an installation with a Chinook, position the coil on the supply or the return of the furnace using sheet metal screws. Drain pans are made of a polymer that can withstand temperatures up to 232.22 C (450 F). Maintain a minimum of 6 clearance over the heat exchanger for installation in the supply. For an installation with a Modulating Supreme, position the coil on the return of the furnace. This is necessary in order to benefit from Auto Backup function, allowing the Supreme and the Alizé heat pump to work together. For installation with all other types of Supreme (Comfort and Advantage), install the coil on either the supply or the return. 1.1 Vertical Vertical A-Coils are designed for upflow and downflow applications. Drain pans have drain connections on the right and left front side of the evaporator coil. See Alize manual for more information. Multi-position A-Coils come factory installed with a vertical and horizontal drain pans and can be configured for upflow, downflow, horizontal blow-through (figure 1 C) or horizontal pull-through (figure 1 B) installations. In the center opening of vertical drain pan, a metal Inlet Air Restrictor is factory installed and is required for horizontal applications. It may be removed for vertical applications. For horizontal configuration, install splash guard onto the coil outlet, and extend suction line insulation into the coil cabinet by 2" to prevent moisture from dripping onto the insulation (the rubber grommet may need to be moved). Splash guard installation is not required for vertical configurations. Bottom flange of guard should rest on pan and sides screwed to the duct flanges. In downflow and counter flow configurations, aluminium foil tape must be applied to seal the top edge of insulation to the cabinet. This tape will prevent the possibility of the insulation delaminating and blocking airflow. In horizontal pull-through and counter flow configurations, a minimum 12" transition is required in front. This is required to ensure proper airflow distribution and to reduce pressure drop. Coil should be level, or pitched slightly towards the drain connection. It is recommended to add silicone caulking between drain pans to prevent water carryover See Alize manual for more informations. 2 METERING DEVICE Do not install any metering device on the indoor coil. The expansion valve is located in the outdoor unit. If a metering device is already installed in the indoor coil, it must be removed. If a metering device (orifice) is installed remove it and be sure to tape it on the coil. This will help ensure it has been removed and help anyone doing service. 2

Table 1 Performances MODEL AIRFLOW VELOCITY WET COIL AIR PAN DEPTH COIL HEIGHT CFM FPM PRESSURE DROP (in w.c.) (IN) (IN) CC1.0-10.0-M 400 261 0.08 19.16 14.25 CC1.5-13.5-V/M 600 224 0.15 19.50 13.00 CC2.5-13.5-V/M 1000 375 0.22 19.50 13.00 CC2.5-15.7-V/M 1000 375 0.18 19.50 13.00 CC3.0-15.7-V/M 1200 337 0.20 19.50 17.00 CC3.0-21.0-V/M 1200 337 0.16 19.50 17.00 CC1.5-S-V/M 600 224 0.09 19.50 13.00 CC2.5-S-V/M 1000 281 0.09 19.50 17.00 CC3.0-S-V/M 1200 337 0.16 19.50 17.00 Table 2 Specifications MODEL NOMINAL CONNECTIONS CONNECTIONS SHIP TONS LIQUID (IN) GAS (IN) WEIGHT (LBS) CC1.0-10.0-M 1.0 1/4 1/2 40 CC1.5-13.5-V/M 1.5 1/4 5/8 40 CHINOOK CC2.5-13.5-V/M 2.5 1/4 5/8 40 CC2.5-15.7-V/M 2.5 1/4 5/8 40 CC3.0-15.7-V/M 3.0 1/4 5/8 41 CC3.0-21.0-V/M 3.0 1/4 5/8 51 CC1.5-S-V/M 1.5 1/4 5/8 51 SUPREME CC2.5-S-V/M 2.5 1/4 5/8 51 CC3.0-S-V/M 3.0 1/4 5/8 51 3

Figure 1 Multi-position configuration 4

Figure 2 Coil dimensions 5