PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LK-004

Similar documents
PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-107

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP- 099

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-076

PRILOGA K AKREDITACUSKI LISTINI Annex to the accreditation certificate

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-004

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

Arrow Instruments Calibration

Metode preskušanja cementa - 1. del: Določanje trdnosti Methods of testing cement - Part 1: Determination of strength

BITUMINOUS DIGITRAC AUTO STABILITY PRESS MARSHALL AUTOMATIC DIGITAL TESTER MARSHALL TESTING MACHINE W/ RECORDER MODELS

ANSI-ASQ National Accreditation Board/ACLASS

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

Građevinski laboratorij d.o.o. Borongajska cesta 84, HR Zagreb Laboratorij Sesvete Slatinska 7, HR Sesvete

SEZNAM AKREDITIRANIH METOD V PRESKUSNEM LABORATORIJU IRMA (LP-008) / LIST OF ACCREDITED METHODS IN TESTING LABORATORY IRMA (LP-008)

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-076

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

Cylinders for Domestic Purposes Heat Pumps

Supertron Sensing Pte Ltd Certificate No. : LA C Blk 16 Kallang Place #07-04 Issue No. : 4 Singapore Date : 04 February 2015

Norma: HRN EN ISO/IEC 17025:2007 Standard: (ISO/IEC 17025:2005+Cor.1:2006; EN ISO/IEC 17025:2005+AC:2006)

MC2501 OPERATING AND CALIBRATION INSTRUCTIONS

Model : LPSA-40A Please read this manual carefully before using the instrument Labnics Equipment

M7100 Pressure Transducer

Seznam akreditiranih metod. Laboratorij za toplotno zaščito in akustiko

Seznam akreditiranih metod Laboratorij za cemente, malte in keramiko

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-047

Simco Calibration Laboratory

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

PSA Series. Particle Size Analyzer

M5800 Pressure Transducer with Rotatable Display

Vibration tests on a TNAML Luminaire

Ultrasonic Clamp-On Flow Meter Testing

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

23" PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT

Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems

Manual Pressure Pump Generators Standard Laboratory Models Operation and Seal Packing Instructions

FRESH AND HARDENED CONCRETE TESTING

الجمهورية الجزائرية الديمقراطية الشعبية

onlinecomponents.com

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

HEAD QUARTER NEW JERSEY LBORATORY VIETNAM LABORATORY

Andrew Cooper Cooper Research Technology. Talar du engelska?

More Precision. indusensor // Linear inductive displacement sensors

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

BCTC CARPET TECHNICAL CENTRE

SPECIFICATIONS. SENSOR SOLUTIONS ///LM Page 1 09/2015

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

Haridarshan Instru-Lab

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

86A SPECIFICATIONS. 316L SS Pressure Sensor Small Profile V High Level Output Gage, Absolute ASIC Calibrated

Contact person Date Reference Page Christian Larsson P01958A 1 (3) Safety

U5600. Wireless Pressure Transducer SPECIFICATIONS

M5800 Pressure Transducer with Rotatable Display

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

17" UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT

CALIBRATION HOW IT WORKS

PRILOG POTVRDI O AKREDITACIJI br: 3115 Annex to Accreditation Certificate Number:

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

Druck DPI 705/DPI 705 IS Series

ISO INTERNATIONAL STANDARD

More Precision. indusensor // Linear inductive displacement sensors

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-032

Laboratorija za ispitivanje građevinskih materijala MMLab d.o.o. Kotor Lasta Grbaljska bb, Kotor

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

U5300 Industrial Pressure Transducer

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

818 Series Low-Power Detectors

OPERATION MANUAL MODEL 8102 ACCELEROMETER

The application of Long Range Ultrasonic Testing (LRUT) to inspect railway tracks

MODEL 834M1 ACCELEROMETER

89BSD Digital Output

STS Directory Accreditation number: STS 0329

BC-HTO RELIABLE SENSING TECHNOLOGY

INTERNATIONAL STANDARD

MSP100 Pressure Transducer

STS Directory Accreditation number: STS 0030

86BSD Digital Output

Annex of the certificate (Page 1/5) Accreditation Scope

XEUS mirror calibration:

Measuring Couch Motion Accuracy with X-ray Beam Fluence

CALIBRATION HOW IT WORKS

More Precision. indusensor // Linear inductive displacement sensors

SECTION METERS AND GAGES FOR HVAC PIPING

TECHNICAL SPECIFICATION

Technical Note. Noise emission from Dehumidifier Type C65E TC Project no.: I Page 1 of July 2016

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

15203B 25203B 35203B Uniaxial Biaxia Triaxial

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

INTERNATIONAL STANDARD

PHIREX AUSTRALIA CATALOGUE & DATA SHEETS. April 2005, Rev 2. Fogex Water Mist Fire Protection System Components PHX-3064

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

SOFTWARE GSHOB - Version A

M5200 Industrial Pressure Transducer

metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD.

ß-Aerosolmonitor FHT 59 C

Transcription:

Reg. št. / Ref..: 3150-0005/10-0019 Datum izdaje / Issued on: 21. december 2017 Zamenjuje izdajo z dne / Replaces Annex dated: 10. november 2016 Veljavnost akreditacije je mogoče preveriti na spletni strani SA,. Information on current accreditation status is available at the SA website,. PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LK-004 1 AKREDITIRANI ORGAN / Accredited body SIJ Ravne Systems d.o.o. Koroška cesta 14, 2390 Ravne na Koroškem 2 STANDARD SIST EN ISO/IEC 17025:2005 3 OBSEG AKREDITACIJE / Scope of accreditation V okviru te akreditacijske listine Slovenska akreditacija priznava akreditiranemu organu usposobljenost za opravljanje naslednjih dejavnosti: / SA hereby acknowledges the accredited body as being competent for performing the following activities: 3.1 Skrajšani opis obsega akreditacije / A short description of the scope Kalibriranje na naslednjih področjih in naštetih pod-področjih (Calibration in the following fields and the specified sub-fields): o Dimenzionalne veličine / Dimensional Quantities: Dolžina / Length (L): merila dolžine, črtna merila, instrumenti za merjenje dolžine, premer, odstopek oblike, hrapavost, navojne veličine, koordinatne merilne naprave, etaloni za velikost delcev / Length gauges, Ruler displacement, Length measuring instruments, Diameter, Form error, Roughness, Thread quantities, Co-ordinate measuring machines, Standards for particle size; Kot / Angle: merila kota, merilniki nagiba / Angle gauges, Clinometers; o Elektrika / Electricity OB05-32 Izdaja 7 Stran 1 od 22

Električne veličine in visokofrekvenčne (VF) veličine / Electric quantities and High Frequency (HF) Quantities o Čas in frekvenca / Time and Frequency Čas / Time Frekvenca / Frequency o Mehanske veličine / Mechanical Quantities: Sila / Force: Merilni sistemi za silo, pretvorniki sile (natezno, tlačno) / Force measuring systems, Force transducers (tension and compression forces); Tehtnice / Weighing instruments: Neavtomatske tehtnice / n-automatic weighing instruments (NAWI); Tlak / Pressure: Manometri za industrijsko uporabo / Manometers for industrial application; Moment sile / Torque: Pretvorniki momenta, momentni ključi, naprava za preverjanje momentnih ključev / Torque transducers, Torque wrenches Mehanska energija / Mechanical energy: Merilniki udarne žilavosti / Pendulum impact-testing machines Merilniki trdote / Hardness testing machines: Brinell, Vickers, Rockwell, Shore; o Fluidne veličine / Fluid quantities: Prostornina tekočin / Volume of Liquids (Porozimetri / porosimeters); o Temperatura, vlaga in termofizikalne lastnosti / Temperature, humidity and thermo-physical properties: Tekočinski termometri / Liquid in-glass thermometers; Indikacijski termometri / Thermometers with indicators; OB05-32 Izdaja 7 Stran 2 od 22

3.2 Podrobni opis obsega akreditacije / Detailed scope of accreditation 3.2.1 Kalibracijski laboratorij, Koroška cesta 14, 2390 Ravne na Koroškem Tabela / Table 1 kalibracije v laboratoriju / in-lab calibrations DIMENZIONALNE VELIČINE / Dimensional Quantities Dolžina / Length (L) Merila dolžine Length gauges Mejna vzporedna dolžinska merila - merilne kladice Gauge blocks L = merjena dolžina / length of the gauge block kalibracijskem postopku QNCL103 QNCL103 1. (0,5 do/to 100) mm 0,05 µm + 2,0 10-6 L - Jeklene merilne kladice - Steel gauge blocks 2. (0,5 do/to 100) mm 0,06 µm + 2,0 10-6 L - Keramične merilne kladice, merilne kladice iz karbidne trdine - Ceramic gauge blocks, tunsten carbide gauge blocks 3. Naprave za kalibracijo mejnih vzporednih dolžinskih meril Gauge block comparators Mejna vzporedna merila merilne kladice in palice Gauge blocks and gauge bars (steel) (0 do/to 100) mm 0,035 µm + 0,002 D kalibracijskem postopku QNCL124 - D= razlika med etaloni v <µm> QNCL124 - measured difference D in <µm> 4. (0 do/to 600) mm 0,4 µm + 2,0 10-6 L kalibracijskem postopku QNCL104 QNCL104 5. (0 do/to 1200) mm 0,6 µm + 2,0 10-6 L 6. (1200 do/to 3000) mm 0,8 µm + 3,0 10-6 L kalibracijskem postopku QNCL104a QNCL104a 7. Stopničasta merila Step gauges Merilne urice Dial gauges (0 do/to 750) mm 2,0 µm + 4,0 10-6 L kalibracijskem postopku QNCL127 QNCL127 kalibracijskem postopku QNCL126 QNCL126 8. (0 do/to 100) mm 3,0 µm + 3,0 10-6 L Ločljivost 0,01 mm / resolution 0,01 mm 9. (0 do/to 100) mm 0,5 µm + 3,0 10-6 L Ločljivost 1 µm / resolution 1 µm OB05-32 Izdaja 7 Stran 3 od 22

10. Vzvodne merilne urice za zunanje in notranje utore ter luknje. Dial gauges for outside and inside measurement. 11. Naprave za kalibracijo merilnih uric Dial gauge testers Induktivna in inkrementalna tipala Inductive and incremental probes (0 do/to 100) mm 3,0 µm + 3 10-6 L kalibracijskem postopku QNCL166 QNCL166 (0 do/to 100) mm 0,1 µm + 2,5 10-6 L kalibracijskem postopku QNCL122, QNCL122a QNCL122, QNCL122a kalibracijskem postopku QNCL131 QNCL131 12. (0 do/to 2 ) mm 0,15 µm 13. (2 do/to 100 ) mm 0,3 µm + 4,0 10-6 L Debelinska merila Thickness gauges kalibracijskem postopku QNCL138 QNCL138 14. (0 do/to 100 ) mm 1 µm + 8 10-6 L 15. (100 do/to 1000 ) mm 2 µm + 10-5 L 16. Merilniki profila pnevmatik Tyre profile depth gauge 17. Volanski kotomeri Steering wheel protractor 18. Merilniki debeline Thickness gauges 19. Merilniki debeline nanosa Coating thickness gauges 20. Ultrazvočni merilniki debeline Ultrasonic thickness gauges (0 do/to 100 ) mm 0,025 mm + 8 10-6 L kalibracijskem postopku QNCL139 QNCL139 (30 do/to 180) º 0,3 º kalibracijskem postopku QNCL137 QNCL137 (0 do/to 100) mm 2,0 µm + 3 10-6 L kalibracijskem postopku QNCL151 QNCL151 (0 do/to 2 ) mm 1,5 µm kalibracijskem postopku QNCL156 QNCL156 (0 do/to 100) mm 20 µm + 1,5 10-5 L kalibracijskem postopku QNCL165 QNCL165 Črtna merila / Ruler displacement Toga črtna merila Rulers kalibracijskem postopku QNCL130, QNCL130a QNCL130, QNCL130a 21. (0 do/to 250) mm 0,6 µm + 2,5 10-6 L 22. (250 do/to 3000) mm 20 µm + 6 10-5 L OB05-32 Izdaja 7 Stran 4 od 22

23. Tračna merila Tape measures 24. Teleskopski metri / Telescopic measuring rods (0 do/to 100) m 20 µm + 2 10-5 L kalibracijskem postopku QNCL114 QNCL114 (0 do/to 10000) mm 0,3 mm + 2,5 10-5 L kalibracijskem postopku QNCL167 QNCL167 Instrumenti za merjenje dolžine / Length measuring instruments Železniška merila - merila za širino in naddvižek tira / Railway length gauges - track and cant gauge kalibracijskem postopku QNCL136 QNCL136 25. Širina Width 26. Naddvižek tira Track and cant 27. Ravnost Flatness 28. Dvotočkovni mikrometri (zunanji) 2 point micrometers (external) 29. Dvotočkovni mikrometri (notranji) 2 point micrometers (internal) Pomična merila Vernier calliper gauges (0 do/to 1435) mm 0,2 mm (-30 do/to 200) mm 0,5 mm 0,1 mm (0 do/to 1000) mm 1,6 µm + 5 10-6 L kalibracijskem postopku QNCL110 QNCL110 (25 do/to 2000) mm 1,6 µm + 8 10-6 L kalibracijskem postopku QNCL110 QNCL110 kalibracijskem postopku QNCL109 QNCL109 30. (0 do/to 1000) mm 10 µm + 1 10-5 L 31. (1000 do/to 2000) mm 25 µm + 1 10-5 L 32. Merilne naprave za merjenje dolžin pri strojih za merjenje mehanskih lastnosti materialov Extensometers in uniaxial testing 33. Merilna kolesa s števcem Measuring wheels with counter Laserski merilniki razdalje Laser distance meters (0 do/to 100) mm 0,5 µm + 1,5 10-5 L kalibracijskem postopku QNCL145 QNCL145 (0 do/to 1000) m 8 mm + 1,5 10-3 L kalibracijskem postopku QNCL158 QNCL158 kalibracijskem postopku QNCL159 QNCL159 34. (0 do/to 10) m 0,15 mm + 3 10-5 L Ločljivost 0,1 mm / resolution 0,1 mm 35. Višinska merila Height gauge (0 do/to 1000) mm 0,6 µm + 1,7 10-6 L kalibracijskem postopku QNCL109a QNCL109a Premer / Diameter OB05-32 Izdaja 7 Stran 5 od 22

36. Trni, gladki Plain plug gauges (0 do/to 200) mm 0,6 µm + 5,0 10-6 L kalibracijskem postopku QNCL106 QNCL106 Obroči, gladki / Plain plug gauges 37. (2 do/to 10) mm 0,7 µm + 5 10-6 L -Neposredna kalibracija po internem kalibracijskem postopku QNCL105a -Direct calibration according to internal QNCL105a 38. (10 do/to 300) mm 0,6 µm + 5,0 10-6 L kalibracijskem postopku QNCL105 QNCL105 39. Tritočkovni mikrometri 3 point micrometers (2 do/to 300) mm 1,6 µm + 7 10-6 L kalibracijskem postopku QNCL110 QNCL110 Odstopek oblike / Form error Merilne plošče Surface plates kalibracijskem postopku QNCL116 QNCL116 40. 4 m x 4 m 1,8 µm + 1 10-6 L 41. 500 x 500 mm Premera / diameter 2,5 µm 42. Lasasta ravnila Knife edge straight edges 43. Ploska ravnila Straight edges 44. Obroči in trni (okroglost) Ring and plug gauges (roundness) 45. Merilniki okroglosti Roundness measuring machine (0 do/to 600) mm 1,5 µm kalibracijskem postopku QNCL152 QNCL152 (0 do/to 2000) mm 5,4 µm kalibracijskem postopku QNCL154 QNCL154 (5 do/to 200) mm 0,15 µm kalibracijskem postopku QNCL161 QNCL161 (0 do/to 275) mm 0,08 µm kalibracijskem postopku QNCL162. QNCL162. Hrapavost / Roughness 46. Vzorci hrapavosti Roughness specimen 47. Tipalni instrumenti za merjenje hrapavosti Stylus instruments for roughness measurements (0,05 do/to 3) µm 0,01 µm + 7 10-2 R a kalibracijskem postopku QNCL128 QNCL128 - Parameter R a (0,05 do/to 3) µm 0,01 µm + 6 10-2 R a kalibracijskem postopku QNCL129 QNCL129 - Parameter R a Navojne veličine / Thread quantities OB05-32 Izdaja 7 Stran 6 od 22

Navojni kalibrski trni / Screw plug gauges: kalibracijskem postopku QNCL108 - Merila: valjasti QNCL108 - Measures: Cylindrical 48. Korak Pitch 49. Bočni kot Thread angle 50. Srednji premer Simple pitch diameter Navojni kalibrski obroči / Screw ring gauges: 51. Korak Pitch 52. Bočni kot Thread angle 53. Srednji premer Simple pitch diameter (0,25 do/to 6,5) mm 0,8 µm (30 do/to 60) º α=bočni kot (po EA-10/10, metoda 1a) / α=thread angle, according to EA-10/10, method 1a (1 do/to 200) mm α= 30º : 6,0 µm + 4 10-6 L α= 55º : 3,5 µm + 4 10-6 L α= 60º : 3,5 µm + 4 10-6 L (0,25 do/to 6,5) mm 0,8 µm kalibracijskem postopku QNCL107, QNCL107a QNCL107, QNCL107a (55 do/to 60) º α=bočni kot (po EA-10/10, metoda 1a) / α=thread angle, according to EA-10/10, method 1a (3 do/to 100) mm α= 55º : 3,5 µm + 4 10-6 L α= 60º : 3,5 µm + 4 10-6 L Koordinatne merilne naprave I Co-ordinate measuring machines 1D merilne naprave 1D measuring machines (po osi/ per axis) kalibracijskem postopku QNCL118, QNCL 120, QNCL 121. QNCL118, QNCL 120, QNCL 121. 54. (0 do/to 100) mm 0,3 µm + 4 10-6 L 55. (100 do/to 1200) mm 0,5 µm + 4 10-6 L 2D merilne naprave 2D measuring machines (po osi/ per axis) kalibracijskem postopku QNCL117, QNCL 119. QNCL117, QNCL 119. 56. (0 do/to 300) mm 1,1 µm + 4 10-6 L Pravokotnost Squareness: 3 " OB05-32 Izdaja 7 Stran 7 od 22

57. Merilni sistemi za merjenje točnosti linearnega pozicioniranja in ponovljivosti osi na obdelovalnih in merilnih strojih Measuring systems for measuring linear positioning accuracy and repeatability of axes in machine tools and measuring machines (0 do/to 40) m 3 µm + 1,5 10-5 L kalibracijskem postopku QNCL160. QNCL160. Etaloni za velikost delcev / Standards for particle size 58. Preskusna sita Test sieves (0 do/to 400) mm 3,2 µm + 4 10-6 L kalibracijskem postopku QNCL146. QNCL146. Kot / Angle Merila kota / Angle gauges 59. Kotniki 90 Squares 90 (0 do/to 600) mm 3,0 µm kalibracijskem postopku QNCL111. QNCL111. 60. Kotomeri Protractors (0 do/to 360) º 2,5 ' kalibracijskem postopku QNCL140. QNCL140. 61. Cilindrični kotniki 90 Cylindrical squares 90 (0 do/to 1000) mm 3,0 µm kalibracijskem postopku QNCL112. QNCL112. 62. Sinusna ravnila Sine bars (0 do/to 700) mm Dolžina / Length: 4,0 µm Ravnost / Flatness: 1,0 µm Vzporednost / Parallelism: 3,0 µm kalibracijskem postopku QNCL113. QNCL113. Merilniki nagiba / Clinometers 63. (0 do/to 1000) mm 5 µm/m kalibracijskem postopku QNCL115. QNCL115. ELEKTRIKA / Electricity Električne veličine in visokofrekvenčne (VF) veličine / Electric quantities and High Frequency (HF) Quantities Ultrazvočni aparati za preiskavo materiala Ultrasonic instruments for material examination Metoda kalibracije skladna s SIST EN 12668-1:2011 točki 8.8.2 in 9, interni postopek QNCL170 -Calibration according to SIST EN 12668-1:2011 paragraph 8.8.2 and 9, internal procedure QNCL170 OB05-32 Izdaja 7 Stran 8 od 22

64. Stabilnost po času ogrevanja: amplitude signala položaja signala 0,8 % amplitude signala 0,2 % položaja signala - 65. Trepetanje prikaza: amplitude signala položaja signala 0,8 % amplitude signala 0,2 % položaja signala 66. Stabilnost pri spreminjanju napajalne napetosti: amplitude signala položaja signala 0,8 % amplitude signala 0,2 % položaja signala 67. Oddajni impulz - napetost V 50: (-1000 do/to 1000) V(DC) 68. Ekvivalentni vhodni šum N in: (0 do/to 1) V/Hz^0,5 69. Iznihavanje oddajnega impulza V r: amplitude signala 70. Nastavitev slabljenja: (0 do/to 110) db 4 % Glede na izmerjeno vrednost 10 % Glede na izračunano vrednost 1 % amplitude signala 0,3 db Glede na izmerjeno vrednost 71. Linearnost vertikalne skale: amplitude signala 1 % amplitude signala 72. Linearnost časovne baze: položaja signala 0,2 % položaja signala ČAS IN FREKVENCA / Time and Frequency Čas / Time Ultrazvočni aparati za preiskavo materiala Ultrasonic instruments for material examination Metoda kalibracije skladna s SIST EN 12668-1:2011 točki 8.8.2 in 9, interni postopek QNCL170 -Calibration according to SIST EN 12668-1:2011 paragraph 8.8.2 and 9, internal procedure QNCL170 73. Oddajni impulz - meritev časa vzpona impulza t r: (0,003 do/to 10) µs 9 % Glede na izmerjeno vrednost OB05-32 Izdaja 7 Stran 9 od 22

74. Oddajni impulz - meritev časa trajanja impulza t d: (0,003 do/to 10) µs 3 % Glede na izmerjeno vrednost Frekvenca / Frequency Ultrazvočni aparati za preiskavo materiala Ultrasonic instruments for material examination Metoda kalibracije skladna s SIST EN 12668-1:2011 točki 8.8.2 in 9, interni postopek QNCL170 -Calibration according to SIST EN 12668-1:2011 paragraph 8.8.2 and 9, internal procedure QNCL170 75. Sprejemnik meritev frekvenčnega območja (0 do/to 100) MHz 4,0 % Glede na izračunano vrednost MEHANSKE VELIČINE / Mechanical Quantities Sila / Force Pretvorniki sile (natezno, tlačno) Force transducers (tension and compression forces) kalibracijskem postopku QNCL147, QNCL147a QNCL147, QNCL147a 76. (10 do/to 1000) N 0,2 % - Z referenčnimi utežmi - With reference weights 77. (0,001 do/to 100) kn 0,25 % - Z referenčnimi električnimi pretvorniki sile - With reference force transducers Merilniki trdote / Hardness testing machines 78. Merilnik trdote kovin po Brinellu Brinell hardness testing machine 60-500 HB 1,5 % - Posredna in neposredna metoda kalibracije skladna s SIST EN ISO 6506-2:2014, interni postopek QNCL148, QNCL148a - Indirect and direct calibration according to SIST EN ISO 6506-2:2014, internal procedure QNCL148, QNCL148a 79. Merilnik trdote kovin po Vickersu Vickers hardness testing machine 120-900 HV 1,5 % - Posredna in neposredna metoda kalibracije skladna s SIST EN ISO 6507-2:2006, interni postopek QNCL150, QNCL150a - Indirect and direct calibration according to SIST EN ISO 6507-2:2006 internal procedure QNCL150, QNCL150a Merilnik trdote kovin po Rockwellu Rockwell hardness testing machine - Posredna in neposredna metoda kalibracije skladna s SIST EN ISO 6508-2:2015, interni postopek QNCL149, QNCL149a - Indirect and direct calibration according to SIST EN ISO 6508-2:2015 internal procedure QNCL149, QNCL149a 80. 20-88 HRA 1,2 HRA 81. 35-100 HRB 1,8 HRB 82. 20-70 HRC 1,2 HRC OB05-32 Izdaja 7 Stran 10 od 22

83. Merilnik trdote po Shore Shore hardness testing machine 10 Shore do/to 100 Shore 0,6 Shore (Shore A in Shore D) - metoda kalibracije po ISO 18898:2012, interni postopek QNCL157. - calibration according to ISO 18898:2012, internal procedure QNCL157. Tehtnice / Weighing instruments Neavtomatske tehtnice / n-automatic weighing instruments - Metoda kalibracije skladna z EURAMET/cg-18/v4.0, interni postopek QNCL144. - Calibration according to EURAMET/cg-18/v4.0, internal procedure QNCL144. 84. m 1 g 0,05 mg 85. 1 g < m 2 g 0,07 mg 86. 2 g < m 3 g 0,12 mg 87. 3 g < m 4 g 0,14 mg 88. 4 g < m 5 g 0,20 mg 89. 5 g < m 10 g 0,17 mg 90. 10 g < m 20 g 0,15 mg 91. 20 g < m 50 g 0,17 mg 92. 50 g < m 100 g 0,28 mg 93. 100 g < m 150 g 0,45 mg 94. 150 g < m 200 g 0,50 mg 95. 200 g < m 220 g 0,65 mg 96. 220 g < m 250 g 0,67 mg 97. 250 g < m 300 g 0,78 mg 98. 300 g < m 400 g 1,00 mg 99. 400 g < m 500 g 1,50 mg 100. 500 g < m 600 g 1,75 mg 101. 600 g < m 1000 g 2,70 mg 102. 1 kg < m 2 kg 5,50 mg 103. 2 kg < m 200 kg 10-4 m Tlak / Pressure OB05-32 Izdaja 7 Stran 11 od 22

Manometri za industrijsko uporabo / Manometers for industrial application kalibracijskem postopku QNCL135. QNCL135. - Merilni instrumenti: mehanski, elektronski. - Measuring instruments: mechanical, electronical. : medij: plin, tekočina, : medium: gas, fluid. 104. (-1 do/to 600) bar 0,16 %; ne manj kot 1 mbar 105. (600 do/to 1000) bar 0,60 % Moment sile / Torque Pretvorniki momenta / Torque transducers - Metoda kalibracije skladna z EURAMET/cg-14/v2.0, interni postopek QNCL132. - Calibration according to EURAMET/cg-14/v2.0, internal procedure QNCL132. : desno / levo, : Clockwise / anticlockwise. 106. (20 do/to 1000) Nm 0,20 % Momentni ključi /Torque wrenches - Metoda kalibracijeskladna z ISO 6789:2003 interni postopek QNCL133. - Calibration according to ISO 6789:2003 internal procedure QNCL133. : desno / levo, : Clockwise / anticlockwise. 107. (0,4 do/to 5) Nm 1,5 % 108. (5 do/to 1500) Nm 0,8 % Naprava za preverjanje momentnih ključev / Device for testing torque wrenches - Metoda kalibracije skadna z EURAMET/cg-14/v.02, interni postopek QNCL164 - Calibration according to EURAMET/cg- 14/v.02, internal procedure QNCL164 : levo / desno : clockwise / anticlockwise. 109. (0,4 do/to 1000) Nm 0,8 % FLUIDNE VELIČINE / Fluid Quantities Prostornina tekočin / Volume of Liquids 110. Porozimetri Porosimeters (0 do/to 10) l 0,1 % - Metoda kalibracije skladna z ASTM C231/C231M-10, Annex A1 točka A1.9, interni postopek QNCL 153. - Calibration according to ASTM C231/C231M-10, Annex A1 item A1.9 internal procedure QNCL153. : samo porozimetri tipa B, Remarks: B type porosimeters only. TEMPERATURA, VLAGA IN TERMOFIZIKALNE LASTNOSTI / Temperature, humidity and thermo-physical properties OB05-32 Izdaja 7 Stran 12 od 22

Tekočinski termometri / Liquid-in-glass thermometers - Primerjalna meritev v po internem kalibracijskem postopku QNCL143. - Calibration by comparison according to internal QNCL143. 111. (-20 do/to 140) C 0,08 C Indikacijski termometri / Thermometers with indicators - Primerjalna meritev v po internem kalibracijskem postopku QNCL143. - Calibration by comparison according to internal QNCL143. 112. (-20 do/to 140) C 0,08 C OB05-32 Izdaja 7 Stran 13 od 22

Tabela / Table 2 kalibracije na terenu (pri stranki) / on-site (at customer location) DIMENZIONALNE VELIČINE / Dimensional Quantities Dolžina / Length (L) Merila dolžine Length gauges L = merjena dolžina / length of the gauge block 113. Naprave za kalibracijo mejnih vzporednih dolžinskih meril Gauge block comparators Merilne urice Dial gauges (0 do/to 100) mm 0,035 µm + 0,002 D kalibracijskem postopku QNCL124 - D= razlika med etaloni v <µm> QNCL124 - measured difference D in <µm> kalibracijskem postopku QNCL126 QNCL126 114. (0 do/to 100) mm 3,0 µm + 2,5 10-6 L Ločljivost 0,01 mm / resolution 0,01 mm 115. (0 do/to 100) mm 0,5 µm + 2,5 10-6 L Ločljivost 1 µm / resolution 1 µm 116. Vzvodne merilne urice za zunanje in notranje utore ter luknje. Dial gauges for outside and inside measurement. 117. Naprave za kalibracijo merilnih uric Dial gauge testers Induktivna in inkrementalna tipala Inductive and incremental probes (0 do/to 100) mm 3,0 µm + 3 10-6 L kalibracijskem postopku QNCL166 QNCL166 (0 do/to 100) mm 0,1 µm + 2,5 10-6 L kalibracijskem postopku QNCL122, QNCL122a QNCL122, QNCL122a kalibracijskem postopku QNCL131 QNCL131 118. (0 do/to 2 ) mm 0,15 µm 119. (2 do/to 100 ) mm 0,3 µm + 4,0 10-6 L Debelinska merila Thickness gauges kalibracijskem postopku QNCL138 QNCL138 120. (0 do/to 100 ) mm 1 µm + 8 10-6 L 121. (100 do/to 1000 ) mm 2 µm + 10-5 L 122. Merilniki profila pnevmatik Tyre profile depth gauge 123. Merilniki debeline Thickness gauges (0 do/to 100 ) mm 0,025 mm + 8 10-6 L kalibracijskem postopku QNCL139 QNCL139 (0 do/to 100) mm 2,0 µm + 3 10-6 L kalibracijskem postopku QNCL151 QNCL151 OB05-32 Izdaja 7 Stran 14 od 22

124. Ultrazvočni merilniki debeline Ultrasonic thickness gauges (0 do/to 100) mm 20 µm + 1,5 10-5 L kalibracijskem postopku QNCL165 QNCL165 Instrumenti za merjenje dolžine / Length measuring instruments 125. Dvotočkovni mikrometri (zunanji) 2 point micrometers (external) 126. Dvotočkovni mikrometri (notranji) 2 point micrometers (internal) 127. Pomična merila Vernier calliper gauges 128. Merilne naprave za merjenje dolžin pri strojih za merjenje mehanskih lastnosti materialov Extensometers in uniaxial testing 129. Višinska merila Height gauge (0 do/to 1000) mm 1,6 µm + 5 10-6 L kalibracijskem postopku QNCL110 QNCL110 (25 do/to 2000) mm 1,6 µm + 8 10-6 L kalibracijskem postopku QNCL110 QNCL110 (0 do/to 1000) mm 10 µm + 1 10-5 L kalibracijskem postopku QNCL109 QNCL109 (0 do/to 100) mm 0,5 µm + 1,5 10-5 L kalibracijskem postopku QNCL145 QNCL145 (0 do/to 1000) mm 0,6 µm + 1,7 10-6 L kalibracijskem postopku QNCL109a QNCL109a Premer / Diameter 130. Tritočkovni mikrometri 3 point micrometers (2 do/to 300) mm 1,6 µm + 7 10-6 L kalibracijskem postopku QNCL110 QNCL110 Odstopek oblike / Form error 131. Merilne plošče Surface plates 132. Lasasta ravnila Knife edge straight edges 133. Ploska ravnila Straight edges 134. Merilniki okroglosti Roundness measuring machine 4 m x 4 m 1,8 µm + 1 10-6 L kalibracijskem postopku QNCL116 QNCL116 (0 do/to 600) mm 1,5 µm kalibracijskem postopku QNCL152 QNCL152 (0 do/to 2000) mm 5,4 µm kalibracijskem postopku QNCL154 QNCL154 (0 do/to 275) mm 0,08 µm kalibracijskem postopku QNCL162. QNCL162. Hrapavost / Roughness 135. Tipalni instrumenti za merjenje hrapavosti Stylus instruments for roughness measurements (0,05 do/to 3) µm 0,01 µm + 6 10-2 R a kalibracijskem postopku QNCL129 QNCL129 - Parameter R a OB05-32 Izdaja 7 Stran 15 od 22

Koordinatne merilne naprave I Co-ordinate measuring machines 1D merilne naprave 1D measuring machines (po osi/ per axis) kalibracijskem postopku QNCL118, QNCL 120, QNCL 121. QNCL118, QNCL 120, QNCL 121. 136. (0 do/to 100) mm 0,3 µm + 4 10-6 L 137. (100 do/to 1200) mm 0,5 µm + 4 10-6 L 2D merilne naprave 2D measuring machines (po osi/ per axis) kalibracijskem postopku QNCL117, QNCL 119. QNCL117, QNCL 119. 138. (0 do/to 300) mm 1,1 µm + 4 10-6 L Pravokotnost Squareness: 3 " 139. Merilni sistemi za merjenje točnosti linearnega pozicioniranja in ponovljivosti osi na obdelovalnih in merilnih strojih Measuring systems for measuring linear positioning accuracy and repeatability of axes in machine tools and measuring machines (0 do/to 40) m 3 µm + 1,5 10-5 L kalibracijskem postopku QNCL160. QNCL160. ELEKTRIKA / Electricity Električne veličine in visokofrekvenčne (VF) veličine / Electric quantities and High Frequency (HF) Quantities Ultrazvočni aparati za preiskavo materiala Ultrasonic instruments for material examination Metoda kalibracije skladna s SIST EN 12668-1:2011 točki 8.8.2 in 9, interni postopek QNCL170 -Calibration according to SIST EN 12668-1:2011 paragraph 8.8.2 and 9, internal procedure QNCL170 140. Stabilnost po času ogrevanja: amplitude signala položaja signala 0,8 % amplitude signala 0,2 % položaja signala - 141. Trepetanje prikaza: amplitude signala položaja signala 0,8 % amplitude signala 0,2 % položaja signala OB05-32 Izdaja 7 Stran 16 od 22

142. Stabilnost pri spreminjanju napajalne napetosti: amplitude signala položaja signala 0,8 % amplitude signala 0,2 % položaja signala 143. Oddajni impulz - napetost V 50: (-1000 do/to 1000) V(DC) 144. Ekvivalentni vhodni šum N in: (0 do/to 1) V/Hz^0,5 145. Iznihavanje oddajnega impulza V r: amplitude signala 146. Nastavitev slabljenja: (0 do/to 110) db 4 % Glede na izmerjeno vrednost 10 % Glede na izračunano vrednost 1 % amplitude signala 0,3 db Glede na izmerjeno vrednost 147. Linearnost vertikalne skale: amplitude signala 1 % amplitude signala 148. Linearnost časovne baze: položaja signala 0,2 % položaja signala ČAS IN FREKVENCA / Time and Frequency Čas / Time Ultrazvočni aparati za preiskavo materiala Ultrasonic instruments for material examination Metoda kalibracije skladna s SIST EN 12668-1:2011 točki 8.8.2 in 9, interni postopek QNCL170 -Calibration according to SIST EN 12668-1:2011 paragraph 8.8.2 and 9, internal procedure QNCL170 149. Oddajni impulz - meritev časa vzpona impulza t r: (0,003 do/to 10) µs 150. Oddajni impulz - meritev časa trajanja impulza t d: (0,003 do/to 10) µs 9 % Glede na izmerjeno vrednost 3 % Glede na izmerjeno vrednost Frekvenca / Frequency OB05-32 Izdaja 7 Stran 17 od 22

Ultrazvočni aparati za preiskavo materiala Ultrasonic instruments for material examination Metoda kalibracije skladna s SIST EN 12668-1:2011 točki 8.8.2 in 9, interni postopek QNCL170 -Calibration according to SIST EN 12668-1:2011 paragraph 8.8.2 and 9, internal procedure QNCL170 151. Sprejemnik meritev frekvenčnega območja (0 do/to 100) MHz 4,0 % Glede na izračunano vrednost MEHANSKE VELIČINE / Mechanical Quantities Sila / Force Merilni sistemi za silo Force measuring systems - Kovinski material po ISO 7500-1:2016; - Metallic materials according ISO 7500-1:2016 kalibracijskem postopku QNCL134 QNCL134 - Betonske stiskalnice po EN 12390-4:2000 skupaj z ISO 7500-1:2016 - Testing machine for concrete according EN 12390-4 together with ISO 7500-1:2016 kalibracijskem postopku QNCL155 QNCL155 152. 10 N do/to 500 kn 0,2 % 153. (0,5 do/to 5) MN 0,75 % Pretvorniki sile (natezno, tlačno) Force transducers (tension and compression forces) kalibracijskem postopku QNCL147, QNCL147a. QNCL147, QNCL147a. 154. (10 do/to 1000) N 0,2 % - Z referenčnimi utežmi - With reference weights Merilniki trdote / Hardness testing machines 155. Merilnik trdote kovin po Brinellu Brinell hardness testing machine 60-500 HB 1,5 % - Posredna in neposredna metoda kalibracije skladna s SIST EN ISO 6506-2:2014, interni postopek QNCL148, QNCL148a. - Indirect and direct calibration according to SIST EN ISO 6506-2:2014, internal procedure QNCL148, QNCL148a. OB05-32 Izdaja 7 Stran 18 od 22

156. Merilnik trdote kovin po Vickersu Vickers hardness testing machine Merilnik trdote kovin po Rockwellu Rockwell hardness testing machine 120-900 HV 1,5 % - Posredna in neposredna metoda kalibracije skladna s SIST EN ISO 6507-2:2006, interni postopek QNCL150, QNCL150a. - Indirect and direct calibration according to SIST EN ISO 6507-2:2006, internal procedure QNCL150, QNCL150a. - Posredna in neposredna metoda kalibracije skladna s SIST EN ISO 6508-2:2015, interni postopek QNCL149, QNCL149a. - Indirect and direct calibration according to SIST EN ISO 6508-2:2015, internal procedure QNCL149, QNCL149a. 157. 20-88 HRA 1,2 HRA 158. 35-100 HRB 1,8 HRB 159. 20-70 HRC 1,2 HRC 160. Merilnik trdote po Shore Shore hardness testing machine 10 Shore do/to 100 Shore 0,6 Shore (Shore A in Shore D) - Metoda kalibracije po ISO 18898:2012, interni postopek QNCL157. - Calibration according to ISO 18898:2012, internal procedure QNCL157. Tehtnice / Weighing instruments Neavtomatske tehtnice / n-automatic weighing instruments - Metoda kalibracije skladna z EURAMET/cg-18/v4.0, interni postopek QNCL144. - Calibration according to EURAMET/cg-18/v4.0, internal procedure QNCL144. 161. m 1 g 0,05 mg 162. 1 g < m 2 g 0,07 mg 163. 2 g < m 3 g 0,12 mg 164. 3 g < m 4 g 0,14 mg 165. 4 g < m 5 g 0,20 mg 166. 5 g < m 10 g 0,17 mg 167. 10 g < m 20 g 0,15 mg 168. 20 g < m 50 g 0,17 mg 169. 50 g < m 100 g 0,28 mg 170. 100 g < m 150 g 0,45 mg 171. 150 g < m 200 g 0,50 mg 172. 200 g < m 220 g 0,65 mg 173. 220 g < m 250 g 0,67 mg OB05-32 Izdaja 7 Stran 19 od 22

174. 250 g < m 300 g 0,78 mg 175. 300 g < m 400 g 1,00 mg 176. 400 g < m 500 g 1,50 mg 177. 500 g < m 600 g 1,75 mg 178. 600 g < m 1000 g 2,70 mg 179. 1 kg < m 2 kg 5,50 mg 180. 2 kg < m 200 kg 10-4 m Tlak / Pressure Manometri za industrijsko uporabo / Manometers for industrial application kalibracijskem postopku QNCL135. QNCL135. - Merilni instrumenti: mehanski, elektronski. - Measuring instruments: mechanical, electronical. : medij: plin, tekočina, : medium: gas, fluid. 181. (-1 do/to 600) bar 0,16 %; ne manj kot 1 mbar 182. (600 do/to 1000) bar 0,60 % Moment sile / Torque Momentni ključi /Torque wrenches - Metoda kalibracije skladna z ISO 6789:2003 interni postopek QNCL133. - Calibration according to ISO 6789:2003 internal procedure QNCL133. : desno / levo, : Clockwise / anticlockwise. 183. (0,4 do/to 5) Nm 1,5 % 184. (5 do/to 1500) Nm 0,8 % Naprava za preverjanje momentnih ključev / Device for testing torque wrenches - Metoda kalibracije skadna z EURAMET/cg-14/v.02, interni postopek QNCL164 - Calibration according to EURAMET/cg- 14/v.02, internal procedure QNCL164 : levo / desno : clockwise / anticlockwise. 185. (0,4 do/to 1000) Nm 0,8 % Mehanska energija / Mechanical energy OB05-32 Izdaja 7 Stran 20 od 22

Merilniki udarne žilavosti / Pendulum impact-testing machines -Posredna in neposredna metoda kalibracije skladna s : SIST EN ISO 148-2:2017 in SIST EN ISO 13802:2015 ali ASTM E23 16b, interni kalibracijski postopek QNCL163 -Indirect and direct calibration according to SIST EN ISO 148-2:2017 and SIST EN ISO 13802:2015 or ASTM E23 16b, internal QNCL163. FLUIDNE VELIČINE / Fluid Quantities Prostornina tekočin / Volume of Liquids (0,2 do/to 750) J Sila / Force: 0,25 % Dolžina /Length: 0,3 mm Kot / Angle:0,1 Čas / Time: 0,1 s Energija / Energy: 4 % 186. Porozimetri Porosimeters (0 do/to 10) l 0,1 % - Metoda kalibracije skladna z ASTM C231/C231M-10, Annex A1 točka A1.9, interni postopek QNCL 153. - Calibration according to ASTM C231/C231M-10, Annex A1 item A1.9 internal procedure QNCL153. : samo porozimetri tipa B, : B type porosimeters only. TEMPERATURA, VLAGA IN TERMOFIZIKALNE LASTNOSTI / Temperature, humidity and thermo-physical properties Tekočinski termometri / Liquid-in-glass thermometers - Primerjalna meritev v po internem kalibracijskem postopku QNCL143. - Calibration by comparison according to internal QNCL143. 187. (-20 do/to 140) C 0,08 C Indikacijski termometri / Thermometers with indicators - Primerjalna meritev v po internem kalibracijskem postopku QNCL143. - Calibration by comparison according to internal QNCL143. 188. (-20 do/to 140) C 0,08 C * CMC opomba / CMC te Razširjena negotovost je podana kot kombinirana standardna negotovost pomnožena s takšnim faktorjem pokritja k, da določa interval zaupanja približno 95 %. / Expanded uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by the coverage factor k such that the coverage probability corresponds to approximately 95 %. ** Navedba informacije o merilnih instrumentih se v tej koloni uporabi le v tistih primerih, kjer to ne izhaja že iz opredelitve veličine, opisa (pod)področja in instrumentov v drugi koloni tabele. / Information on measuring instruments are specified in this column only if it is not clear from the description of quantity, (sub-) field, and/or instruments in the second column of this table. *** Kadar je za enoumno razumevanje zmogljivosti potreben opis robnih pogojev, vplivnih veličin ali drugih omejitev se ti navajajo v tej koloni (z enoumno oznako kolone), območje merjene veličine pa je v takem primeru določeno že v drugi koloni te tabele. / When a description of the boundary conditions, influence quantity or other limits is required for an unequivocal understanding of capabilities it is specified in this column (clearly indicated), providing that the range of measured quantity is defined in the second column of this table. OB05-32 Izdaja 7 Stran 21 od 22

Kopija priloge k akreditacijski listini za objavo na spletnem mestu. Podpisani original priloge na vpogled na sedežu SA. Copy of Annex to the accreditation certificate for web publishing. Signed original of Annex available for consultation at the SA head office. Direktor / Director dr. Boštjan Godec OB05-32 Izdaja 7 Stran 22 od 22