Clavex Plus Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module PC Software Controller with Graphic Display Printer Module Features Ÿ 160 X 80 Monochrome Graphic Display for Comprehensive Process Information Ÿ 4 Universal Temperature Inputs for Control & Mapping Ÿ User Programmable Temperature Measurement Strategy (MAP-1 or Average of MAP-1 to MAP-4 or Min/Max of All Mappings) Ÿ 1 Universal Input (ma / V) for Pressure Indication with Programmable Units (PSI, KG/CM2, BAR & EU) Ÿ Programmable Setpoint for Air Exhaust Valve Closing Ÿ Automatic Cycle Abortion at High Temperature Safety Limit & Low Water Level Ÿ Front / Remote Sterilization Cycle Start Command Ÿ F0 Value Calculation & Indication Ÿ Temperature Dependent Cycle Resumption Upon Power Interruption Ÿ Digital Inputs for Door Open & Low Water Level Detection Ÿ In-built Huge Memory for Autoclave Cycle Data Recording with Settable Interval Ÿ Digital s (SSR Drive) for Heating, Air Exhaust Valve and Alarm Ÿ 21 CFR Compliance PC Software for Report Generation with User Programmable Company Name/Logo & Footer Ÿ Programmable Sterilization Timer with Setpoints for Timer Pause & Reset Ÿ Optional Printer Interface Module for Direct Printout of Report on 80/132 Column Dot-Matrix Printer
Specifications Display Graphic LCD Keys Functions Analog Inputs 4 Temperature Inputs (Control & Mapping) Strategy for Computing Temperature for Control Pressure Input Accuracy Display Resolution Zero Offset ADC Sampling Time Common Mode Rejection Signal Conditioning Door Status Monitoring Input Function Water Level Monitoring Input Function Alarm System Process Alarm Door Open Alarm Water Level Alarm Audio Alert Alarm Acknowledge Temperature Control Loop Control Parameters 160 X 80 STN Monochrome 6 Tactile Switches SCROLL PAGE START / STOP & ALARM ACK UP DOWN ENTER User Programmable (Common for all 4 Inputs) RTD Pt100, 3 wire DC Linear : 0-20 ma, 4-20 ma, 0-5 V, 0-10 V, 1-5 V User Programmable Ÿ MAP-1 Temperature as Final Temperature Ÿ Average of MAP-1 to MAP-4 Ÿ Default MAP-1. If MAP-1 Sensor fails then Average of other MAPs Ÿ Min / Max of MAP-1 to MAP-4 for different Cycle States User Programmable : 0-20 ma, 4-20 ma, 0-5 V, 0-10 V, 1-5 V RTD Pt100 : ± 0.25% of reading ± 1 C DC Volts/Current : ± 0.25% of reading ± 1 LSD For Temperature : 0.1 C For Pressure User Programmable : 1 / 0.1 / 0.01 / 0.001 User Adjustable over Full Range (Independent for Each Input) 16 Bit (±32,768 Counts), Sigma-Delta (ΣΔ) 250mS (4 Samples per Second) > 100dB at 50/60 Hz L-C Analog Filter on Each Input Digital Input (Potential-free Contacts) from Door Switch Abort Running Cycle / Ignore Start Command & Alarm Digital Input (Potential-free Contacts) from Float Switch Abort Running Cycle / Ignore Start Command & Alarm High Temperature Safety Limit Alarm on Door Open Alarm on Water Level Low in Steam Generator In-Built Buzzer (Beeper) SSR for Remote Switching of Audio/Visual Gadget on Alarms Front Panel Alarm Acknowledge (Mute) Key ON-OFF Control Band (Hysteresis) SSR Drive Voltage
Air Exhaust Control Control Strategy (Programmable) Data Recording Storage Device Recording Interval On-Off Ÿ Remains open till temperature reaches Air Outlet SP Ÿ Closes after reaching Air Outlet SP until Process completed SSR Drive Voltage In-built Micro SD Card (2 GB) User Programmable Recording Data (Date/Time Stamped) Power Supply Line Voltage Consumption Physical Mounting Overall Dimensions Panel Cutout Terminals Environmental Operating Ambient Ÿ Process Values Mapping Temperatures & Pressure Ÿ Events Start Command Air Valve Close Sterilization Start Air Valve Open Sterilization End Sterilization Reset Stop Command Change in Date/Time Settings Change in Recording Interval Change in Parameter Values Autoclave Door Open Fail Safe Low / High Alarm Ÿ Final F0 Value Switch Mode (SMPS) 18 ~ 32 VDC, nominal 24 VDC @ 1A Min. Note : In case of looping multiple instruments on one power source, make sure that the source is capable of supplying minimum 1A current per instrument. 5VA Max Plug-in with Panel Mounting Clamps 80 (H) X 160 (W) 144 (D) 78 (H) X 154 (W), mm Storage Temperature -10 to +70 C 3.5 mm Pitch, Pluggable Terminal Blocks 0~55 C & 5~90%RH Non-condensing Atmospheres Not Suitable for use in Corrosive or Explosive Atmospheres. The Panel in which the Instrument is Mounted must be free of Electrically Conductive Pollution.
Back Panel Terminations 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 + DOOR ma- MAP-4 MAP-3 MAP-2 MAP-1 + - WATER LEVEL V Temperature Inputs START PRESSURE COMMON MAP CONNECTIONS Control s MAP - X Supply RS485 COMM HTR AIR ALM DEV PC + - + - + - + - + - Clavex Plus + - 1 2 3 4 5 6 7 8 9 10 RTD Configuration 31 32 33 18~32VDC V ma PC Printer PC Interface with 21 CFR Compliant Software Supported Operating Systems (OS) Minimum PC Configuration Requirements Windows Vista Windows 7 32 bit / 64 bit Windows 8 32 bit / 64 bit Pentium Dual Core 2.8 GHz Clock Speed 2 GB RAM 40 GB Hard Disk Printer Interface (Optional Add-on Device) Controller Interface Port Printer Interface Port Printer Support Print Data Supply Voltage RS485 Serial Centronix (Parallel Interface) 80/132 Column Dot-Matrix (EPSON LX-300-II or Equivalent) Well-Formated, Date-Time Stamped Process value & Event Records (PC Tool for user Programmable Header & Footer) 10~30 VDC (24 VDC Nominal)
Sample Report ProcessPrecisionInstruments(AnISO9001:2008Company) 101,DiamondIndustrialEstate,Navghar,VasaiRoad(E),Dist.Palghar-401210,Maharashtra,India 0250-2391722/33/37/420250-2391734sales@ppiindia.net www.ppiindia.net