LED Compatible Daylight Harvesting and Motion Sensor System

Similar documents
FR-A180 FR-A360. Occupancy detector. Use

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components

IN2 Lighting Control Devices

User Manual 120/240/300 Outdoor Motion Detector

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

compact office 24V compact office 24V Lux

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

PräsenzLight PräsenzLight PräsenzLight A.. PräsenzLight A..

Reduce lighting energy costs with controls

compact office 24V compact office 24V Lux

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

1. Basic safety information 3 2. Proper use 3

EBMHS (standard & slim-line PSU)

Sensors Explained AUTOMATION

Sensors and Detectors

µdim Microwave Sensors User Manual

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Analogue Dimming Microwave Presence/Absence Detector

IP 55 (category II) IP 54 (category II) 4. Connection. 1. Basic safety information. 2. Proper use. 5. Installation. 3. Description.

Busch-Watchdog presence. Overview and applications of presence detectors.

B.E.G. LUXOMAT. Find the right detector.

The Power To Supply... All Your Electrical Products

, ,

SENSA MRE DDM MR

The two type sensors are innovative and active motion dimmable LED drivers or ballasts.

1. Basic safety information 3 2. Proper use 3

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

PresenceLight 180 PresenceLight 360

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Direct Dim Microwave Presence/Absence Detector

Integrated PIR detectors

SWITCHLITE MRE DDM ADJ

HF Motion Sensor Introduction

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Product and Applications Description

False Ceiling HF Sensors

Lighting Control Strategies. to meet code requirements save energy and improve building performance

600 Watt Dimmer Install Guide

Introduction. Dimming Function MC003V (Standard Version) MC003V R (Reinforced Version)

Loop out. Ambient daylight threshold

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Product Specifications

Lighting Control. Sensor Daylight 2. Daylight+Motion 3. Daylight+Motion+Control 4. Daylight+Motion+Control IP67 5

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX..

INSTRUCTIONS MANUAL SAUNA USER INTERFACE ENGLISH

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

Tebis application software

PRODUCT CATALOGUE LIGHT CONTROL Grässlin products for the intelligent control of light

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

UP 258E11 OPTISENS OFFICE

Tri-level Control HF Sensor

Tri-level Control HF Sensor

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

Trios Training Manual

The Power To Supply... All Your Electrical Products

BRIGHTEN YOUR LIFE. LED Troffer Light. Benefits. RoH S BB-RTGD-XXX-A-XX-D

Product Specifications

DHL-LP-LED Low Profile LED Linear High/Low Bay

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle

Detailed operating instructions

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

Note: A summary of the applicable code sections is shown in the CEC _Table100A.

Integrated Classroom Control System. Installation and Operation Manual

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

North America Version / Dimming Function. Introduction

LED ECO PANEL.

Light Management Systems: Energy Savings.

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

WARRANTY LED ECO PANEL.

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

Installation Instructions

Lighting & Controls Motion & Presence Detectors

design guide for wireless l i g h t i n g c o n t r o l

Eco-sensors - PIR. Catalogue number(s): / / Use. 1. Use Technical characteristics (continued)

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

CS1200 WHT Pir Ceiling Mount Occupancy Sensor

Devices for Special Applications

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

TROFFER RETROFIT KIT (TRK)

LPCMPIRM65 & LPCMPIRDSI65

Tri-level Control HF Sensor

Description of the application programme for KNX occupancy detectors version 3.1

High Frequency Sensor

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

Transcription:

MADE IN GERMANY BY OUR FRIENDS AT EPV

DH1 Technical Data MAX. MOUNTING HEIGHT AMBIENT TEMP. CURRENT CONSUMPTION 5m 0 50 C (Indoor) max. 15mA at 24V SWITCHING CAPACITY Occupancy Signal: Max. Dimming Status Signal: Daylight Dimming Signal Open Collector, max. 30 ma Open Collector, max. 30 ma 1..10V, max 10mA DELAY TIME 10 secs -14 min Adjustable DIMMING SET POINT Guaranteed maintained light level above which the artificial lighting is dimmed (100-1.000 lux) REAR FRONT DH1 CONNECTIONS POWER SUPPLY 15-28V AC or DC from Occupancy Sensor Adapter BMA or customer systems. e.g. building management system

DH1 Installation & Accessories Installation by qualified Electricians only. Do not mount the sensor in the direct light of the switched lamps. How to select the dimming setpoint. Turn the dimming potentiometer to the point where without any daylight the artifical lights are on at 100% and there is no dimming just yet (10V). Measure output to ballast with voltmeter with balllasts connected. How to select the delay time. When using the DH1 with fluorescent lamps, please set the delay time to approx. 10 minutes or more (recommendation by lamp manufacturers). FLUSH MOUNTING SURFACE MOUNTING OCCUPANCY SENSOR ADAPTER Standard installation in suspended ceilings. 45mm ceiling hole. Sensor is held in place with clip (supplied). Applicable to partitioned ceilings e.g. ceiling tiles. Optional installation ring. Applicable e.g. to plasterboard ceilings where standard clip can not be fitted from behind. Product-Nr. 101415 Applicable for retrofits on concrete ceilings. Product- Nr. 101472 Accessories for concrete canister mounting also available on request. Connect up to 4 of 24V sensors in parallel, incl. Daylight Dimming. 230V power supply + switching relay. Optional remote control for DH1. DH1 Motion Sensor Observation Area W W L The DH1 covers a rectangular area on the floor. The orientation of the rectangle is indicated by a symbolic rectangle on the front of the sensor, so you can orient the sensor to best match your room. The size of this observation area can be reduced by pulling out the shading ring around the sensor lense (not applicable for 10m types). 5M TYPES Height(m) W(m) L(m) 1.9 4.3 5.37 2.0 4.53 5.65 2.1 4.75 5.93 2.2 4.98 6.21 2.3 5.21 6.5 2.4 5.43 6.78 2.5 5.66 7.06 2.6 5.89 7.34 2.7 6.11 7.62 2.8 6.34 7.91 2.9 6.57 8.19 3 6.79 8.47 3.1 7.02 8.75 3.2-5m 7.24 9.04

Daylight Harvesting: Definitions and Diagrams. What is Daylight Harvesting? Daylight harvesting is the ability to sense the light levels as they change using a daylight harvesting senor. A Daylight Harvesting Sensor automatically dims the LED lights to maintain an exact light level in a room. INTERIOR LIGHT LEVEL ENERGY SAVINGS 12AM 1AM 12PM 6PM 12AM TIME OF DAY TARGET LIGHT LEVEL LED LIGHTING DAYLIGHT ENEREGY SAVINGS

DH1 Power Pack for Daylight Harvesting This DH1 Motion Sensor adapter provides a quick and easy way to connect up to 4 of the 24V Occupancy Sensors in parallel. Use in connection with 1 Lead Sensor DH1/24V/5Lsa or /Lsab (incl. Daylight Dimming) and add up to 3 additional simpler sensors DH1/24V/5 (sensors without dimming). The sensors are connected to the adapter with RJ12 cables. The observation areas of the sensor add up resulting in the connected sensors working like one sensor with a very large observation are. Typical use: Open plan offices, large areas. Can also be used with sensors that do NOT provide a Daylight dimming output. In this case the Dimming Signal remains at Max (10V) constantly. Also available with remote control, see next page. DH1 Power Pack: Technical Data POWER SUPPLY 230V, 50 Hz AMBIENT TEMP. 0 50 C Indoor POWER CONSUMPTION max. 3 VA MAXIMUM LOAD ON DIMMING OUPUT (1..10V) 10mA SCOPE OF DELIVERY SWITCHING CAPACITY (BUILT-IN RELAY) 10A continuous or 120A inrush current (whichever applies first). For a further switching capacity extension we offer an external contactor relay (30A continuous, 250A inrush current) Product-Nr. 101511 PLEASE NOTE Disconnect mains power when connecting the low-voltage side. DH1 Power Pack: Accessories 2 INTO 1 PLUG. ART. NR. 101382 CABLE ADAPTER KA 01M ART. NR. 100539 These plugs enable the connection of several DH1/24V sensors with RJ12 cables. For example, wire RJ12 from Power Pack to first sensor, into the 2-into-1 plug and loop the RJ12 onwards to the next sensor and so on. Easy access & extension option if you want to use existing wiring instead of full RJ12. Not supplied with BMA2-NL.

DH1 Power Pack with Remote Control Option DH1 Power Pack Functionality With Occupancy / Daylight Harvesting Sensor (e.g. DH1/24V/5LSa) connected: Toggle between manual and automatic dimming. Lights can be dimmed up and down manually by holding down the butto on the remote control. This disables/overwrites the automatic Daylight Harvesting. A short press on the button puts the system back into fully automatic Occupancy Sensing and Daylight Harvesting mode. No Occupancy Sensor connected = Standalone remote controlled manual dimmer Lights can be dimmed up and down manually to the desired light level by holding down the button on the remote control. A short press on the button turns the lights on and off. Dimming speed (min to max.): approx. 6 seconds Applications: Conference rooms, offices. How to program the power pack to recognize a remote control: How to delete remote controls from the power pack: