Code Compliance Commercial Application Guide

Similar documents
Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2012

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

ANSI/ASHRAE/IES

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

ANSI/ASHRAE/IES

Quick Install Energy Solutions Featuring Energi TriPak

Quick Install Energy Solutions

Light control solutions

Retrofit Solutions NEW. Energy-saving products for single rooms. Lutron energy-saving products. Patient Rooms. Office Spaces. Affordable Solutions

Vive wireless hub. BACnet Integration. Demand Response

Lutron Sensor Solutions. Lutron energy-saving light controls for your home or office. simple. affordable. energy-saving.

lighting control Simple and scalable Flexible control every step of the way DESIGN INSTALL MAINTAIN

Maestro Wireless dimmers, switches and sensors

Quick Install Energy Solutions Featuring Energi TriPak

MANDATORY MEASURES MANDATORY LIGHTING CONTROLS (a) Area Controls: Manual controls that control lighting in each area separately

Codes and Controls Commercial Building Energy Code Requirements for Light Control. Michael Jouaneh, CEM, LEED AP September 20, 2012

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

FCSENS0R Occupancy Sensor. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

lighting control Flexible control every step of the way Simple, scalable, wireless DESIGN INSTALL MAINTAIN

Code Compliance. Lightcloud. Guides for California Title 24 & ASHRAE

lighting control Simple and scalable Flexible control every step of the way DESIGN INSTALL MAINTAIN

RA2 Select. Whole home lighting control made simple. Lutron.com/ra2select. Lutron Electronics Co., Inc Suter Road Coopersburg, PA

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

Application Note #407 Revision F March 2019

Spaces are over lighted by 10-20% designed for worst-case interiors and fabrics, adjustable systems can tune-out waste

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130)

Wireless Wall-Mount Sensor

lighting control Simple, scalable, wireless Transform existing buildings with wireless lighting controls Wireless controls and sensors

Volume 1: Basic devices and single-space systems

GRAFIK RA 2. Convenient, wireless light and blind control Integrates with leading smart home brands

ASHRAE October 18, 2013

Vive PowPak Fixture Controls

Code Review TITLE PRESENTED BY POURIA NIKNAM

WSA120: New Energy Codes and Lighting Controls

Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard & 2013

Fixture Controller. Applications. Features. Specifications. Certifications & Affiliations. Catalog #: ALC/ALCE Part #: /

Mini Product Guide.

Lighting Control Strategies. to meet code requirements save energy and improve building performance

Maestro 0 10 V Dimmer Sensor

Education Title Solutions

visual environment technologies etcconnect.com

TITLE 24 ICONOGRAPHY. Iconography System

Wireless Indoor Lighting Control System

Lighting Application Guide for K-12 Classrooms

visual environment technologies etcconnect.com

ViveTM Basic Packages

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings

LED Control Solutions

California Title Design Guide for Smart Lighting Control and Energy Solutions

A Guide for Applicants and Lighting Designers

Lighting Control. Sensor Daylight 2. Daylight+Motion 3. Daylight+Motion+Control 4. Daylight+Motion+Control IP67 5

GRAFIK T Controls GRAFIK T

IECC. nlight Applications Guide.

Note: A summary of the applicable code sections is shown in the CEC _Table100A.

Office Title Solutions

Here we see the list of auto shutoff controls we will cover in the next few slides

The Bahen Centre for Information Technology. Meeting Room Lighting Redesign. Introduction. University of Toronto ~ Toronto, Ontario, Canada

Energi Savr NodeTM. A versatile, energy saving lighting control solution that is easy to install and easy to expand

Healthcare Title Solutions

Good-Better-Best LED Retrofit Guide

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 26 ELECTRICAL

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

Lighting Controls. Energy-Saving Solutions For Efficient Buildings

Restaurants ASHRAE Solutions

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Restaurants IECC 2015 Solutions

Dimmer/Switch with Occupancy and Vacancy Sensor

Hospitality Title Solutions

Reduce lighting energy costs with controls

DUFFERIN-PEEL CATHOLIC DISTRICT SCHOOL BOARD

Wireless Wall-Mount Sensor

Energy Codes. Connected Lighting simplified by Eaton. design and application guide

miniz Quick Start Guide

LIGHTING CONTROLS

RadioRA 2 PRELIMINARY COPY 68 F 70 F. Wall-mounted seetemp display for temperature control Coming soon!

PRESCRIPTIVE APPROACH

SENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1

LED Control Solutions. Smooth, flicker-free dimming for every application

2015 IECC. Design Guide for Smart Lighting Control and Energy Solutions

Philips Lighting North America Corporation 200 Franklin Square Drive Somerset, NJ Tel

Wireless Wall-Mount Sensor

600 Watt Dimmer Install Guide

Commercial Energy Solutions Suggested List Pricing. October 1, 2009 Euro

The two type sensors are innovative and active motion dimmable LED drivers or ballasts.

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

Advanced Lighting For Office

Sensors Explained AUTOMATION

CA TITLE 24 QUICK SOLUTIONS GUIDE FOR

Applied Lighting Controls

GRAFIK TTM Controls GRAFIK TTM. Wallbox Controls

EcoSystem H-Series Ballasts

Are LED s ready for Prime Time?

INTEGRATED CONTROLS GUIDE

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Dimming Ballast + Controls and CALCTP Bonus. New Product Overview

WARRANTY LED ECO PANEL.

LED ECO PANEL.

Maestro Occupancy Sensing Switch

Surface Materials. Surface Material Reflectance. Acoustic Ceiling 80% Tile. Painted Gypsum 75% Wall Board. Vinyl Composition 32% Tile

Transcription:

Code Compliance Commercial Application Guide ASHRAE 90.1-2010 IECC 2012 Title 24-2013

Summary of code requirements for lighting control In the following pages, we ve provided examples of how Lutron solutions save energy and help meet energy codes in commercial spaces such as classrooms, offices, restrooms, and more. The table below describes new construction and retrofit (lighting alterations 1 ) code requirements for ASHRAE 90.1-2010, IECC 2012, and Title 24-2013 2. For specific commercial building code lighting requirements in your state, please visit www.lutron.com/energycodes. Code Provision (ASHRAE 90.1-2010; IECC 2012; T24-2013) Description Key exceptions or notes Classroom, Lecture Hall, Training Room Conference, Meeting, Multipurpose Room Applications where needed Office (enclosed <250 ft 2 ) Office (open) Corridor Restroom Stairwell Storage Room Area Control [9.4.1.2; C405.2.1.1; 130.1(a)] Automatic Lighting Shutoff [9.4.1.1; N/A; 130.1(c)] Each space must have an accessible, manual control device (switch or dimmer) to control the general lighting. All indoor lighting must have an automatic shut-off control, such as an occupancy sensor or time switch (i.e. timeclock). ASHRAE 90.1: sensors comply. IECC: Corridors and stairwells are exempt. Daylight Control [9.4.1.4; C405.2.2.3.1; 130.1(d)] Daylight control is required for general lighting in daylight zones; some codes require this to be automatic and multi-level. ASHRAE 90.1: Only required in new construction. Requires automatic multi-level control. IECC: Requires automatic multi-level control for skylighted zones and when the window-to-wall ratio is greater than 30%. Otherwise, a separate daylight zone with manual on/off complies. Title 24: Requires automatic multi-level control. Functional Testing [9.4.4; C408.3; 130.4(a)] Manual ON or Partial ON [9.4.1; N/A; N/A] Multi-level Lighting Control [9.4.1.2a; C405.2.1.2; 130.1(b)] Sensor Control [9.4.1.2b; C405.2.2.2; 130.1(c)5] Lighting controls must be tested to ensure that they are working properly. Automatic controls (e.g. occupancy sensors) must be manual-on or auto-on to not more than 50% lighting power. Most spaces must allow the occupants to select a lighting level that is between 30% and 70% of full power (at least 50% or lower for IECC) in addition to OFF. This requirement does not apply to spaces with a lighting power density less than 0.5 W/sq. ft. or smaller than 100 sq. ft. sensors that turn off lighting within 30 minutes of vacancy are required in certain spaces. ASHRAE 90.1: Only required in new construction. Title 24: Not required. ASHRAE 90.1: Only required in new construction. Not required in corridors, restrooms, or storage rooms. IECC: Spaces with occupancy sensing are exempt. Not required in corridors, restrooms, or storage rooms. - A uniform level of illumination must be maintained. - Continuous dimming complies. ASHRAE 90.1: Must be manual ON or partial ON. IECC: Must be manual ON or partial ON. Partial OFF Control [9.4.1.6g; N/A; 130.1(c)6C] Lighting power must be automatically reduced by at least 50% within 30 minutes of vacancy. ASHRAE 90.1: Only required in new construction. ASHRAE 90.1: Not required in corridors. IECC: Not required. Disclaimer: This table is a summary only; other exceptions or details may apply. Jurisdictions may have requirements that differ from these standards. See page 32 for notes/references.

Classroom: Switching Lighting Alterations 3 Daylight Control Manual Sensor Control All lights are switching only Manual On Auto Off SW2 do not automatically turn on when automatically turn off 15 minutes SW3 MRF2-1S8A-1VK Simple Retrofit Corner Vacancy Package 1 $198.00 MRF2-8S-DV-WH Maestro Wireless Switch 2 $150.00 Total Price $498.00 Manual Wall Light Control provides ON/OFF control for the interior general lighting SW2 provides ON/OFF control for the whiteboard lighting SW3 provides ON/OFF control for the daylight row near the windows 45%4 04 See page 32 for notes/references. 05

Classroom: Dimming 1 of 12 Daylight Control Automatic Multi-level Lighting Control Sensor Control SW2 EHDT832MU210 EcoSystem H-Series Ballast 12 $79.00 RMJ-ECO32-DV-B PowPak EcoSystem Dimming Module 1 $170.00 LRF2-VKLB-P-WH Low voltage wiring Wireless Corner Vacancy Sensor 1 $85.00 LRF2-DCRB-WH Radio Powr Savr Wireless Daylight Sensor 1 $120.00 PJ-3BRL-GWH-I01 Pico Wireless Control 2 $25.00 PICO-FP-ADAPT Pico Faceplate Adapter 2 $8.00 All lights are dimmable The maximum light level has been set to 80% do not automatically turn on when automatically turn off 15 minutes Daylight The general lighting is controlled by the daylight sensor and automatically brightens and dims to maintain the required light level in the space The daylight sensor can be manually overridden by wall switch is programmed to control all of the general lighting and provides ON/OFF control, BRIGHTEN/DIM control, and allows for one preset light level SW2 is programmed to control the whiteboard lighting and provides ON/ OFF control, BRIGHTEN/DIM control, and allows for one preset light level Manual On Full On Max: 100% Max: 80% Full On 80% Auto Off Dim Dim Personal Dimming High-End Trim/Tuning Daylight Harvesting 65%4 Total Price $1,389.00 06 See page 32 for notes/references. 07

Conference Room: Switching Lighting Alterations 3 SW2 Daylight Control Manual Sensor Control All lights are switching only Manual On Auto Off do not automatically turn on when automatically turn off 15 minutes LRF2-VKLB-P-WH Wireless Corner Vacancy Sensor 1 $85.00 MRF2-8S-DV-WH Maestro Wireless Switch 2 $150.00 Total Price $385.00 Manual Wall Light Control provides ON/OFF control for the daylight row near the windows SW2 provides ON/OFF control for the interior general lighting 40%4 08 See page 32 for notes/references. 09

Conference Room: Dimming 1 of 6 SW2 Daylight Control Automatic Multi-level Lighting Control Sensor Control EHDT832MU210 EcoSystem H-Series Ballast 6 $79.00 RMJ-ECO32-DV-B PowPak EcoSystem Dimming Module 1 $170.00 LRF2-VKLB-P-WH Low voltage wiring Wireless Corner Vacancy Sensor 1 $85.00 LRF2-DCRB-WH Radio Powr Savr Wireless Daylight Sensor 1 $120.00 PJ-3BRL-GWH-I01 Pico Wireless Control 2 $25.00 PICO-FP-ADAPT Pico Faceplate Adapter 2 $8.00 All lights are dimmable The maximum light level has been set to 80% do not automatically turn on when automatically turn off 15 minutes Daylight All of the lights are controlled by the daylight sensor and automatically brighten and dim to maintain the required light level in the space The daylight sensor can be manually overridden by wall switches and SW2 is programmed to control the four lights closest to the door and provides ON/ OFF control, BRIGHTEN/DIM control, and allows for one preset light level SW2 is programmed to control the whiteboard lighting and provides ON/OFF control, BRIGHTEN/DIM control, and allows for one preset light level Manual On Full On Max: 100% Max: 80% Full On 80% Auto Off Dim Dim Personal Dimming High-End Trim/Tuning Daylight Harvesting 65%4 Total Price $915.00 10 See page 32 for notes/references. 11

Private Office: Switching Lighting Alterations 3 Daylight Control Manual Sensor Control SW2 All lights are switching only Manual On Auto Off do not automatically turn on when automatically turn off 15 minutes MRF2-1S8A-1VC Simple Retrofit Ceiling Vacancy Package 1 $198.00 MRF2-8S-DV-WH Maestro Wireless Switch 1 $150.00 Total Price $348.00 provides ON/OFF control for the daylight row near the windows SW2 provides ON/OFF control for the interior general lighting 30%4 12 See page 32 for notes/references. 13

Private Office: Dimming 1 of 4 Daylight Control Automatic Multi-level Lighting Control Sensor Control EHDT832MU210 EcoSystem H-Series Ballast 4 $79.00 RMJ-ECO32-DV-B PowPak EcoSystem Dimming Module 1 $170.00 LRF2-VCR2B-P-WH Low voltage wiring Wireless Ceiling Vacancy Sensor 1 $85.00 LRF2-DCRB-WH Radio Powr Savr Wireless Daylight Sensor 1 $120.00 PJ-3BRL-GWH-I01 Pico Wireless Control 1 $25.00 All lights are dimmable The maximum light level has been set to 80% do not automatically turn on when automatically turn off 15 minutes Daylight All of the lights are controlled by the daylight sensor and automatically brighten and dim to maintain the required light level in the space The daylight sensor can be manually overridden by wall switch is programmed to all of the lights and provides ON/OFF control, BRIGHTEN/DIM control, and allows for one preset light level Manual On Full On Max: 100% Max: 80% Full On 80% Auto Off Dim Dim Personal Dimming High-End Trim/Tuning Daylight Harvesting 60%4 PICO-FP-ADAPT Pico Faceplate Adapter 1 $8.00 Total Price $724.00 14 See page 32 for notes/references. 15

Open Office: Switching Lighting Alterations 3 Daylight Control Manual Sensor Control All lights are switching only Manual On Auto Off do not automatically turn on when automatically turn off 15 minutes RMJ-16R-DV-B PowPak Relay Module (16A) 2 $109.00 LRF2-VCR2B-P-WH SW2 Wireless Ceiling Vacancy Sensor 4 $85.00 PJ-2B-GWH-I01 Pico Wireless Control 2 $25.00 provides ON/OFF control for the daylight rows near the window SW2 provides ON/OFF control for the interior general lighting 35%4 PICO-FP-ADAPT Pico Faceplate Adapter 2 $8.00 Total Price $644.00 16 See page 32 for notes/references. 17

Open Office: Dimming 1 of 16 Daylight Control Automatic Multi-level Lighting Control Sensor Control All lights are dimmable The maximum light level has been set to 80% do not automatically turn on when automatically turn off 15 minutes Manual On Auto Off 80% Max: 100% Max: 80% Full On Dim High-End Trim/Tuning Daylight Harvesting EHDT832MU210 EcoSystem H-Series Ballast 16 $79.00 RMJ-ECO32-DV-B PowPak EcoSystem Dimming Module 1 $170.00 LRF2-VCR2B-P-WH Low voltage wiring Wireless Ceiling Vacancy Sensor 4 $85.00 LRF2-DCRB-WH Radio Powr Savr Wireless Daylight Sensor 1 $120.00 PJ-3BRL-GWH-I01 Pico Wireless Control 1 $25.00 Daylight The two perimeter rows of lights are controlled by the daylight sensor and automatically brighten and dim to maintain the required light level in the space The daylight sensor can be manually overridden by wall switch is programmed to all of the lights and provides ON/OFF control, BRIGHTEN/DIM control, and allows for one preset light level 60%4 PICO-FP-ADAPT Pico Faceplate Adapter 1 $8.00 Total Price $1,927.00 18 See page 32 for notes/references. 19

Corridor/Hallway: Switching Sensor Control To Emergency Power The emergency light is not controlled All controlled lights are switching only automatically turn on when an occupant enters the space automatically turn off 15 minutes Occupied: On Vacant: Off RMJ-5R-DV-B PowPak Relay Module (5A) 1 $89.00 LRF2-OHLB-P-WH Wireless Hallway Sensor 1 $85.00 Total Price $174.00 50%4 20 See page 32 for notes/references. 21

Corridor/Hallway: Dimming Corridor/Hallway: Dimming Multi-level Lighting Control Sensor Control Partial OFF 1 of 6 To Emergency Power Low voltage wiring All lights are dimmable The maximum light level has been set to 80% automatically turn on to 80% when an occupant enters the space Occupied: On Vacant: Off 80% Max: 100% Max: 80% High-End Trim/Tuning automatically turn off 15 minutes Instead of turning off, lights can be programmed to dim to a low light level if desired EHDT832MU210 EcoSystem H-Series Ballast 6 $79.00 RMJ-ECO32-DV-B PowPak EcoSystem Dimming Module 1 $170.00 LRF2-OHLB-P-WH Wireless Hallway Sensor 1 $85.00 PJ-3BRL-GWH-I01 Pico Wireless Control 1 $25.00 is programmed to all of the lights and provides ON/OFF control, BRIGHTEN/DIM control, and allows for one preset light level 60%4 PICO-FP-ADAPT Pico Faceplate Adapter 1 $8.00 Total Price $762.00 22 See page 32 for notes/references. 23

Restroom: Single Stall Sensor Control All lights are switching only Occupied: On Vacant: Off automatically turn on when an occupant enters the space automatically turn off 15 minutes provides ON/OFF control for all the lights in the space MS-OPS6M2-DV-WH Maestro Switch 1 $49.00 Total Price $49.00 50%4 24 See page 32 for notes/references. 25

Restroom: Multiple Stalls 1 of 4 Multi-level Lighting Control Sensor Control EHDT832MU210 EcoSystem H-Series Ballast 4 $79.00 RMJ-ECO32-DV-B PowPak EcoSystem Dimming Module 1 $170.00 LRF2-OCR2B-P-WH Low voltage wiring Wireless Ceiling Sensor 2 $85.00 PJ-3BRL-GWH-I01 Pico Wireless Control 1 $25.00 All lights are dimmable The maximum light level has been set to 80% automatically turn on to 80% when an occupant enters the space automatically turn off 15 minutes Instead of turning off, lights can be programmed to dim to a low light level if desired is programmed to all of the lights and provides ON/OFF control, BRIGHTEN/DIM control, and allows for one preset light level Occupied: On Vacant: Off 80% Max: 100% Max: 80% High-End Trim/Tuning 60%4 PICO-FP-ADAPT Pico Faceplate Adapter 1 $8.00 Total Price $689.00 26 See page 32 for notes/references. 27

Stairwell Sensor Control Partial OFF All lights are dimmable The maximum light level has been set to 80% automatically turn on to 80% when an occupant enters the space Occupied: On Vacant: Off 80% Max: 100% Max: 80% High-End Trim/Tuning automatically dim to 20% 15 minutes after all occupants leave the space FX-SW-XX-14-2-28- U-82-SM-XX-WH LRF2-OKLB-P-WH Lutron 4' Two-Lamp T8 Fluorescent Stairwell Fixture Wireless Corner Sensor 2 $390.00 1 $85.00 PJ-2B-GWH-I01 Pico Wireless Control 1 $25.00 is programmed to all of the lights and provides ON/OFF control 70%4 PICO-FP-ADAPT Pico Faceplate Adapter 1 $8.00 Total Price $898.00 28 See page 32 for notes/references. 29

Storage Room Sensor Control All lights are switching only do not automatically turn on when Manual On Auto Off automatically turn off 15 minutes provides ON/OFF control for all of the lights in the space MS-VPS6M2-DV-WH Maestro Vacancy Switch 1 $49.00 Total Price $49.00 30%4 30 See page 32 for notes/references. 31

Notes/References 1. Lighting alterations and control requirements : Lighting alterations that involve more than 10% of the lighting load in a space must meet the Automatic Lighting Shutoff provision (9.4.1.1). A lighting alteration includes the addition or removal of luminaires, or the replacement of lamps plus ballasts in a space. : Lighting alterations require compliance with all of the lighting control requirements. A lighting alteration is defined as a replacement of 50% or more of the luminaires in a space. The replacement of only the lamps plus ballasts within an existing luminaire is exempt from meeting the control requirements in the space as long as the alteration doesn t increase the lighting power density (W/ft 2 ). Title 24-2013: Replacement of more than 10% of the luminaires, or modifying 40 or more existing luminaires, requires compliance with all the control requirements for the altered space (daylight control and demand responsive control are not always required; see the Table 141.0E and 141.0F in the Standard for details). 2. Demand response is required in Title 24-2013 for buildings larger than 10,000 sq. ft. 3. Separate daylight zone and switch (manual daylight control) not required in ASHRAE 90.1-2010 for lighting alterations. 4. All savings numbers based on data collected from Lutron projects and the following journal articles: VonNieda B, Maniccia D, & Tweed A. 2000. An analysis of the energy and cost savings potential of occupancy sensors for commercial lighting systems. Proceedings of the Illuminating Engineering Society. Paper #43. Williams A, et al. 2012. Lighting Controls in Commercial Buildings. Leukos. 8(3) pg 161-180. Reinhart CF. 2002. Effects of interior design on the daylight availability in open plan offices. Study of the American Commission for an Energy Efficient Environment (ACE) Conference Proceedings. To achieve maximum lighting savings, automated shades are utilized. Galasiu AD, et al. 2007. Energy saving lighting control systems for open-plan offices: A field study. Leukos. 4(1) pg 7-29. 32