Optoelectronic level switches, models OLS-C. Optoelektronische Füllstandsschalter, Typen OLS-C. Commutateurs de niveau opto-électroniques, type OLS-C

Similar documents
Gas cylinder scale Model GCS-1

max C 15 minutes other types on request 3 x 0,25 mm2 or plug M8, other types on request

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

Instruction Manual. Electronic gas and smoke detector GRM

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

TTV 4500 / TTV 4500 HP / TTV 7000

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

3-way switching valve

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

Indoor/outdoor resistance thermometer Model TR60

Universal controller for panel mounting Models CS6S, CS6H, CS6L

ED3002 ED3004 ED3007 ED3030 ED3100

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

MANUAL Oil Level Sensor

TDS 20 R / TDS 30 R / TDS 50 R

Operating Manual. Series FCU5xxx. Sauna Sauna & Humidity Sauna, Humidity & IR Steam Bath FCU5000 FCU5200 FCU5400 FCU5000-STEAM. VDE in preparation

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

FSW300 Series Flow Switch

SCHMIDT LED Measured Value Display MD Instructions for Use

WIO200 Water in oil sensor

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

Operating Manual. VIENNA Hot Display

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

BES M30EP-PFC12F-S04G-D12 BES Q40ZU-PFC15B-S04G-D12 BES Q40ZU-PFC20F-S04G-D12 Inductive Safety Sensors User's Manual

Operator s manual. Battery charger C 48/ en / 03

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Original operating instructions Safety switch with guard locking AC901S AC902S

Flameproof Manual Call Points

GB Operating instructions

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

SWARCO TRAFFIC SYSTEMS GMBH. TDD1-MW Traffic Detector User Manual TDD1-MW_BE_00

Silent TS. Nr / Ideas for dental technology / A. Made in Germany

BKA-EN Fire Damper. Additional operating instructions according to

Original instructions JSNY7 Magnetic switch

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

EUROFLAT SERIES TYPES C... S... M...

Original instructions Sense7-series Non-contact coded safety switch

BSK-RPR Fire Damper. Additional operating instructions according to

Laser Distance Sensor Type M Analog-Output

Part 3 Troubleshooting

Operating Manual MS220DA

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

/ / 2018

Conductivity Electrode LRG Original Installation Instructions English

Retroreflective sensor with polarization filter

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Turbimax CUE21 / CUE22

USE AND INSTALLATION HANDBOOK

compact office 24V compact office 24V Lux

TTK 70 S OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK70S-TC-001-EN

Turbimax CUE21 / CUE22

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

TTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN

Aluminum Heating Mantles

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

Operating Manual MS220KA and MSR220KA

Operating Instructions. Digital Radar Motion Detector With Infrared Remote Control MWD BF. Hörmann KG Verkaufsgesellschaft

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

Sensing light curtain as per DIN 18650/EN 16005

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

compact office 24V compact office 24V Lux

AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Rev A

Sensing light curtain as per DIN 18650/EN 16005

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

Table of Contents. 1. Mounting Tips... 2

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

HXL. Operating instructions

EHA Hoffmann International GmbH

WIO200 Water In Oil measuring instrument

Vacuum Controller with Control Unit VC 900

SILENT compact /

Important Safety Notice

PAC 2000 E OPERATING MANUAL LOCAL AIR CONDITIONER TRT-BA-PAC2000E-TC EN

Monitored Pneumatic Valves On Series Ported Manifold

Operating instructions

Operating Manual. English. Refrigerators for chemicals KRC 50 KRC 180

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.


INSTALLATION GUIDE Ultrasonic Sensors Series UPR-A Atex

Operating Instructions

Operating Instruction

Retroreflective sensor with polarization filter

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

2. General information Page Warnings Page Technical characteristics Page Installation Page Front panel Page 7

User manual DEAN-10-C

3.2 E1 Outdoor Unit PCB Abnormality E4 Actuation of Low Pressure Sensor E5 Compressor Motor Lock 3 52

SHORT WAVE INFRARED PANEL DRYER

Black Body Calibration Source User Manual

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Vibracon LVL-A* Level limit switch for liquids, compact design

Transcription:

Operating instructions Operating instructions Betriebsanleitung Mode d'emploi Manual de instrucciones Optoelectronic level switches, models OLS-C Optoelektronische Füllstandsschalter, Typen OLS-C Commutateurs de niveau opto-électroniques, type OLS-C Interruptores de nivel optoelectrónicos, modelos OLS-C DE FR ES Examples for optoelectronic level switches models OLS-C Model OLS-C01 Model OLS-C02 Model OLS-C20 FLUID CONTROL A division of the WIKA group

Contents Contents 31076041.02 09/2015 /DE/FR/ES 1. General information 34 2. Design and function 45 3. Safety 89 4. Transport, packaging and storage 12 13 5. Commissioning, operation 12 13 6. Faults 15 16 7. Maintenance and cleaning 17 18 8. Dismounting, return and disposal 18 19 9. Specifications 19 20 Appendix 1: EC declaration of conformity models OLS-C01, OLS-C02, OLS-C04, OLS-C05 23 24 Appendix 2: EC declaration of conformity model OLS-C20 24 25 Appendix 3: EC declaration of conformity model OLS-C29 25 26 Declarations of conformity can be found at online www.tc-fluidcontrol.com at www.wika.com. WIKA operating instructions optoelectronic level switches, models OLS-C 3 TC Fluid Control operating instructions Optoelectronic level switches, models OLS-C 2

1. General information 1. General information The level switches described in the operating instructions have been designed and manufactured using state-of-the-art technology. All components are subject to stringent quality and environmental criteria during production. Our management systems are certified to ISO 9001 and ISO 14001. These operating instructions contain important information on handling the instrument. Working safely requires that all safety instructions and work instructions are observed. Observe the relevant local accident prevention regulations and general safety regulations for the instrument's range of use. The operating instructions are part of the product and must be kept in the immediate vicinity of the instrument and readily accessible to skilled personnel at any time. Pass the operating instructions onto the next operator or owner of the instrument. Skilled personnel must have carefully read and understood the operating instructions prior to beginning any work. The general terms and conditions contained in the sales documentation shall apply. Subject to technical modifications. Further information: - Internet address: www.wika.de / www.wika.com - Relevant data sheet: LM 31.31 (OLS-C01), LM 31.32 (OLS-C02), LM 31.33 (OLS-C05), LM 31.34 (OLS-C04), LM 31.02 (OLS-C20), LM 31.03 (OLS-C29) 4 WIKA operating instructions optoelectronic level switches, models OLS-C TC Fluid Control operating instructions Optoelectronic level switches, models OLS-C 3 31076041.02 09/2015 /DE/FR/ES

2. Design and function 2. Design and function 2.1 Description This instrument is used for the detection of limit levels in liquids. The measuring principle is independent of refractive index, colour, density, conductivity and dielectric constant. The switches consist of an infrared LED and a phototransistor. The light of the LED is directed into a prism. So long as the sensor tip of the prism is in the gas phase, the light is reflected within the prism to the receiver. When the liquid in the vessel rises and wets the glass tip, the infrared lightbeam into the liquid is interrupted and only a small portion reaches the receiver. Operating principle Gas Liquid The integrated switch electronics offer an automatic adjustment so that there is a wide field of application. For the output, there is an O.C. pnp-transistor switching output or a relay switching output. 31076041.02 09/2015 /DE/FR/ES 2.2 Instrument construction Depending on the switch type, the instruments are fitted with different process connections. These contain a glass prism and the electronics responsible for the evaluation. TC WIKA Fluid operating Control operating instructions instructions optoelectronic Optoelectronic level switches, level switches, models models OLS-C OLS-C 4 5

2. Design and function Dimensions in mm Model OLS-C01 Model OLS-C02 Function indicator LED Circular connector M8 x 1, 3-pin (alternatively cable connection) Cable Cable outlet M16 x 1.5, PG11 (alternatively circular or angular connector) Glass prism Glass prism 6 WIKA operating instructions optoelectronic level switches, models OLS-C TC Fluid Control operating instructions Optoelectronic level switches, models OLS-C 5 31076041.02 09/2015 /DE/FR/ES

2. Design and function Model OLS-C04 Model OLS-C05 Angular connector 175301-803 A Cable Cable outlet (alternatively circular connector) Function indicator LED (alternatively cable connection or circular connector) SW 30 Glass prism Glass prism 31076041.02 09/2015 /DE/FR/ES TC WIKA Fluid operating Control operating instructions instructions optoelectronic Optoelectronic level switches, level switches, models models OLS-C OLS-C 6 7

2. Design and function Model OLS-C20 green LED Cable outlet (alternatively circular connector) Cable length 3,000 Legend: ML fixed measuring length 24 mm Model OLS-C29 LED dependent on process connection ca. 64 LED 41 62 Process connection 47 Case with electronics 2.3 Scope of delivery Cross-check scope of delivery with delivery note. Cable 8 WIKA operating instructions optoelectronic level switches, models OLS-C TC Fluid Control operating instructions Optoelectronic level switches, models OLS-C 7 31076041.02 09/2015 /DE/FR/ES

3. Safety 3. Safety 3.1 Explanation of symbols WARNING!... indicates a potentially dangerous situation that can result in serious injury or death, if not avoided. Information... points out useful tips, recommendations and information for efficient and trouble-free operation. 3.2 Intended use The optoelectronic level switches should only be used for level control or monitoring of liquid media. Their scope of application is defined by their technical performance limits and their materials. Improper use is defined as any application that exceeds the technical performance limits or is not compatible with the materials. Checking against improper use is the responsibility of the operator. The liquids must not have any large contamination or coarse particulates and must not have a tendency to crystallise. Ensure that the wetted materials of the switch are sufficiently resistant to the medium being monitored. Not suitable for dispersion, abrasive liquids, highly viscous media and colours. This instrument is not permitted to be used in hazardous areas! 31076041.02 09/2015 /DE/FR/ES The maximum power and voltage values as specified in the operating instructions should be adhered to. TC WIKA Fluid operating Control operating instructions instructions optoelectronic Optoelectronic level switches, level switches, models models OLS-C OLS-C 8 9

3. Safety Do not operate the instruments in the immediate vicinity of strong electromagnetic fields or in the immediate vicinity of equipment that can be affected by magnetic fields (min. clearance 1 m). The responsiveness of the instrument is preset and, with models OLS-C20 and OLS-C29, cannot be adjusted. With the models OLS-C01, OLS-C02, OLS-C04 and OLS-C05, the responsiveness can only be adjusted if the switch is fitted with a trimmer. The switches must not be exposed to heavy mechanical strain (impact, bending, vibration). The instrument has been designed and built solely for the intended use described here, and may only be used accordingly. The manufacturer shall not be liable for claims of any type based on operation contrary to the intended use. 3.3 Improper use WARNING! Injuries through improper use Improper use of the instrument can lead to hazardous situations and injuries. Refrain from unauthorised modifications to the instrument. Do not use the instrument within hazardous areas. Any use beyond or different to the intended use is considered as improper use. Do not use this instrument in safety or emergency stop devices. 10 WIKA operating instructions optoelectronic level switches, models OLS-C TC Fluid Control operating instructions Optoelectronic level switches, models OLS-C 9 31076041.02 09/2015 /DE/FR/ES

3. Safety 3.4 Responsibility of the operator The instrument is used in the industrial sector. The operator is therefore responsible for legal obligations regarding safety at work. The safety instructions within these operating instructions, as well as the safety, accident prevention and environmental protection regulations for the application area must be maintained. To ensure safe working on the instrument, the operating company must ensure that the operating personnel are regularly instructed in all topics regarding work safety, first aid and environmental protection and know the operating instructions and in particular, the safety instructions contained therein. that the instrument is suitable for the particular application in accordance with its intended use. 3.5 Personnel qualification WARNING! Risk of injury should qualification be insufficient Improper handling can result in considerable injury and damage to equipment. The activities described in these operating instructions may only be carried out by skilled personnel who have the qualifications described below. 31076041.02 09/2015 /DE/FR/ES Skilled personnel Skilled personnel, authorised by the operator, are understood to be personnel who, based on their technical training, knowledge of measurement and control technology and on their experience and knowledge of country-specific regulations, current standards and directives, are capable of carrying out the work described and independently recognising potential hazards. TC WIKA Fluid Control operating operating instructions instructions optoelectronic Optoelectronic level level switches, switches, models models OLS-C OLS-C 10 11

3. Safety 3.6 Labelling, safety marks Product label (examples) Model OLS-C20 Model OLS-C20 Art.-Nr.13496159 SA G1/2 + - 24 V WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 63911 Klingenberg BN (2) WS (1) GN (3) Output Pin assignment Model OLS-C04 Date of manufacture Symbols Before mounting and commissioning the instrument, ensure you read the operating instructions! For further specifications Instruments see data bearing sheet LM this 31.01 mark and comply order with documentation. the relevant European directives. 12 WIKA operating instructions optoelectronic level switches, models OLS-C TC Fluid Control operating instructions Optoelectronic level switches, models OLS-C 11 31076041.02 09/2015 /DE/FR/ES

4. Transport... / 5. Commissioning, operation 4. Transport, packaging and storage 4.1 Transport Check the switch for any damage that may have been caused by transport. Obvious damage must be reported immediately. 4.2 Packaging and storage Do not remove packaging until just before mounting. Permissible conditions at the place of storage: Storage temperature: 0... 70 C 5. Commissioning, operation When unpacking the switch, check all components for any external damage. Prior to installation, a functional check can also be carried out. For this, the instrument should be connected temporarily and the glass prism dipped in and out of a glass of liquid to test it. 5.1 Mounting Before installation, it must be ensured that the mounting hole and the fixing device for the switches in the vessel are correct in size and dimension. 31076041.02 09/2015 /DE/FR/ES Mount the switch, pressure-sealed, into the process connection. Following installation, the glass tip should have a distance of at least 10 mm to the opposite wall. This minimum clearance can vary dependent upon the geometry and surface finish of the wall. Note: with electropolished pipes, the minimum distance to the opposite surface must be a minimum of 20 mm. WIKA operating instructions optoelectronic level switches, models OLS-C 13 TC Fluid Control operating instructions Optoelectronic level switches, models OLS-C 12

5. Commissioning, operation Installation instructions Horizontal installation Vessel or pipe wall Rubber or metal sealing Vertical installation fitting with sealing face Inclined installation Installation in elongated fitting elongated fitting Insulation 5.2 Electrical connection The electrical connection of the switches can be found in the following connection diagrams. 14 WIKA operating instructions optoelectronic level switches, models OLS-C TC Fluid Control operating instructions Optoelectronic level switches, models OLS-C 13 31076041.02 09/2015 /DE/FR/ES

5. Commissioning, operation Electrical connection diagram Models OLS-C01, OLS-C02, OLS-C04 and OLS-C05 Connector assignment DC 12... 32 V DC 12... 32 V Output Output Load 0 V 0 V Model OLS-C20 brown 24 V Connector assignment green Output 0 V 24 V white Load 0 V Output Model OLS-C29, power supply 230 V OLS-C29 BN (brown) YE (yellow) GN (green) OG (orange) BK (black) Phase NO COM NC Output Neutral conductor 31076041.02 09/2015 /DE/FR/ES Model OLS-C29, power supply 24 V OLS-C29 RD (red) YE (yellow) GN (green) OG (orange) BK (black) 24 V NO COM NC Output Neutral conductor TC WIKA Fluid operating Control operating instructions instructions optoelectronic Optoelectronic level switches, level switches, models models OLS-C OLS-C 14 15

5. Commissioning, operation / 6. Faults Switching delay and blink codes for model OLS-C29 The model OLS-C29 switch features a pre-programmed switching delay of 1 s (optional are other times, up to 12 s), after which time the signal relay's state changes. This acts to suppress fast changes in the switching status, e.g. with bubbling or wave effects in the tank. The functional check can be carried out in-situ via the built-in LEDs. Their blink codes are given in the following table. Operating state LED Relay Switching on blinks 3 x deactivated Wetted (sensor in the optically denser medium) goes on 2 x per second activated Dry (sensor in the optically less dense medium) goes off 2 x per second deactivated Error blinks 5 x per second deactivated 6. Faults The following table contains the most frequent causes of faults and the necessary countermeasures. 16 WIKA operating instructions optoelectronic level switches, models OLS-C TC Fluid Control operating instructions Optoelectronic level switches, models OLS-C 15 31076041.02 09/2015 /DE/FR/ES

6. Faults Faults Causes Measures No function Despite a change in level, no alteration in the display and no switching of the output Failure in power supply Glass tip dirty Glass tip too close to an opposite surface Measure voltage, check cable or plug connection Clean the glass tip (introduce service intervals) Increase the distance, change the mounting location Glass tip defective Exchange the glass tip (model OLS-C29) or return to the manufacturer Instrument responds inversely Wrong switching function (normally open, normally closed) Replace instrument Relay connections inverted (model OLS-C29) Change relay connections over Instrument obviously does not respond or responds too slowly on a level change (model OLS-C29) Switching delay Wait for delay time 31076041.02 09/2015 /DE/FR/ES CAUTION! Physical injuries and damage to property and the environment If faults cannot be eliminated by means of the listed measures, the instrument must be taken out of operation immediately. Ensure that pressure is no longer present and protect against accidental commissioning. Contact the manufacturer. If a return is needed, please follow the instructions given in chapter 8.2 Return. WIKA operating instructions optoelectronic level switches, models OLS-C 17 TC Fluid Control operating instructions Optoelectronic level switches, models OLS-C 16

7. Maintenance and cleaning 7. Maintenance and cleaning For contact details, please see chapter 1 General information or the back page of the operating instructions. 7.1 Maintenance The optoelectronic level switches work maintenance-free in normal operation. They must be subjected to visual inspection within the context of regular servicing, however, and included in the tank pressure test. Repairs must only be carried out by the manufacturer. 7.2 Cleaning CAUTION! Physical injuries and damage to property and the environment Improper cleaning may lead to physical injuries and damage to property and the environment. Residual media in the dismounted instrument can result in a risk to personnel, the environment and equipment. Rinse or clean the removed instrument. Sufficient precautionary measures must be taken. 1. Prior to cleaning, properly disconnect the instrument from the process and the power supply. 2. Clean the instrument carefully with a moist cloth. 3. Electrical connections must not come into contact with moisture! CAUTION! Damage to property Improper cleaning may lead to damage to the instrument! Do not use any aggressive cleaning agents. Do not use any pointed and hard objects for cleaning. 18 WIKA operating instructions optoelectronic level switches, models OLS-C TC Fluid Control operating instructions Optoelectronic level switches, models OLS-C 17 31076041.02 09/2015 /DE/FR/ES

8. Dismounting, return and disposal 8. Dismounting, return and disposal WARNING! Physical injuries and damage to property and the environment through residual media Residual media in the dismounted instrument can result in a risk to personnel, the environment and equipment. Wash or clean the dismounted instrument, in order to protect personnel and the environment from exposure to residual media. 8.1 Dismounting Only disconnect the measuring instrument once the system has been depressurised and the power disconnected! If necessary, the measuring line must have strain relief. 8.2 Return Wash or clean the dismounted switch before returning it, in order to protect personnel and the environment from exposure to residual media. Information on returns can be found under the heading Service on our local website. 31076041.02 09/2015 /DE/FR/ES 8.3 Disposal Incorrect disposal can put the environment at risk. Dispose of instrument components and packaging materials in an environmentally compatible way and in accordance with the countryspecific waste disposal regulations. WIKA operating instructions optoelectronic level switches, models OLS-C 19 TC Fluid Control operating instructions Optoelectronic level switches, models OLS-C 18

9. Specifications 9. Specifications Models OLS-C01, OLS-C02, OLS-C04 and OLS-C05 General data Measuring accuracy Mounting position Visual indication of the switching status ±0.5 mm as required 1 LED (not for model OLS-C02) Design data Responsiveness preset Medium temperature Models OLS-C01, OLS-C02: -30... +100 C Model OLS-C04: -40... +100 C Model OLS-C05: -40... +150 C Ambient temperature Models OLS-C01, OLS-C02: -25... +70 C Model OLS-C04: -30... +70 C Model OLS-C05: -30... +80 C Operating pressure 0 2.5 MPa (0 25 bar) Model OLS-C04: 0 4 MPa (0 40 bar) Electrical data Power supply Max. current supply Output Switching function Switching current DC 12... 32 V 40 ma PNP transistor, protected against reverse polarity Normally open (closed in medium) or normally closed (open in medium) 200 ma Ingress protection IP 65 Number of switch points 1 20 WIKA operating instructions optoelectronic level switches, models OLS-C TC Fluid Control operating instructions Optoelectronic level switches, models OLS-C 19 31076041.02 09/2015 /DE/FR/ES

9. Specifications Model OLS-C20 General data Measuring accuracy Light source Ambient light Mounting position Visual indication of the switching status ±0.5 mm IR light 930 nm max. 10,000 Lux as required green LED Design data Medium temperature -30... +135 C Ambient temperature -25... +70 C Pressure range Materials Sensor housing Light guide Packing Case 0... 50 bar Stainless steel 1.4571 Fused quartz Graphite/PTFE Stainless steel 1.4301 31076041.02 09/2015 /DE/FR/ES Electrical data Power supply DC 24 V, -25... +30 % Max. current supply Output Switching function Switching current (T u = 70 C) Electrical connection PVC cable Connector Ingress protection With connector With cable 40 ma O. C. pnp transistor, short-circuit proof, current, voltage and power limitation Normally open (closed in medium) or normally closed (open in medium) 0.5 A 3 x 0.14 mm 2 4-pin series 712, M12 IP 65 IP 66 WIKA operating instructions optoelectronic level switches, models OLS-C 21 TC Fluid Control operating instructions Optoelectronic level switches, models OLS-C 20

9. Specifications Model OLS-C29 General data Measuring accuracy Material Electronic case Process connection Prism Mounting of the case to the process connection Light source Ambient light ±0.5 mm PA66, glass-fibre reinforced Steel, nickel-plated Borosilicate glass Union nut IR light 930 nm max. 500 Lux Design data Medium temperature -30... +120 C Ambient temperature -30... +60 C Max. operating pressure Mounting position Visual indication of the switching status Switching delay (factory set, fixed) 42 bar horizontal red LED approx. 1 s, others up to 12 s on request Electrical data Power supply AC 110... 230 V ±15 % or DC 24 V ±15 % Current supply max. Output relay Switching voltage, current, power Connection cable Mech. service life Ingress protection IP 54 approx. 22 ma Change-over contact AC 250 V, NC = 5 A, NO = 7 A, 1,750 VA 5 x 0.75 mm 2, L = 2 m, colour-coded approx. 10 5 switching cycles 22 WIKA operating instructions optoelectronic level switches, models OLS-C TC Fluid Control operating instructions Optoelectronic level switches, models OLS-C 21 31076041.02 09/2015 /DE/FR/ES

9. Specifications For further specifications see WIKA data sheets LM 31.31 (OLS-C01), LM 31.32 (OLS-C02), LM 31.33 (OLS-C05), LM 31.34 (OLS-C04), LM 31.02 (OLS-C20) or LM 31.03 (OLS-C29) and order documentation. 31076041.02 09/2015 /DE/FR/ES WIKA operating instructions optoelectronic level switches, models OLS-C 23 TC Fluid Control operating instructions Optoelectronic level switches, models OLS-C 22

Appendix 1: EC declaration of conformity 24 WIKA operating instructions optoelectronic level switches, models OLS-C TC Fluid Control operating instructions Optoelectronic level switches, models OLS-C 23 31076041.02 09/2015 /DE/FR/ES

Appendix 1: EC declaration of conformity 24 WIKA operating instructions optoelectronic level switches, models OLS-C TC Fluid Control operating instructions Optoelectronic level switches, models OLS-C 24 31076041.02 09/2015 /DE/FR/ES

Appendix 3: EC declaration of conformity 31076041.02 09/2015 /DE/FR/ES 26 WIKA operating instructions optoelectronic level switches, models OLS-C TC Fluid Control operating instructions Optoelectronic level switches, models OLS-C 25

TC Fluid Control Unit 4 The Interchange Wested Lane Swanley Kent BR8 8TE Tel: +44 (0) 1322 622400 Fax: +44 (0)1322 660621 Email: instruments@tc-fluidcontrol.com Scotland office: Office 1/05 King James Business Centre Friarton Road Perth PH2 8DY Tel: +44 (0) 1738 472015 Fax: +44 (0)1322 660621 Email: instruments@tc-fluidcontrol.com FLUID CONTROL A division of the WIKA group www.tc-fluidcontrol.com