WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

Similar documents
Description of components and operating logic of the unit MICRA Ventilation system arrangement example based on the unit MICRA 60...

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

SINGLE-ROOM ENERGY RECOVERY VENTILATORS

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Series VENTS VUT R WH ЕС

KOMFORT EC DB Suspended heat recovery air handling units

Offices. Conference halls. Kindergartens Libraries. Restaurants. Schools. Sport halls. Shops

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

DOMEKT. Residential ventilation air handling units

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Controlled mechanical ventilation GB 03

SINGLE-ROOM VENTILATION. for schools and public spaces

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

HEAT RECOVERY AIR HANDLING UNIT

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5.

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Installation manual Mini Comfort 50 S/L 07/ V EN

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

HEAT RECOVERY VENTILATOR

Model with intellectual humidity control and extra motion sensor control

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

Destratification Fan Units DRF-VK & DRF-VKM & DRF-OV

VERSO Air Handling Units

Heat Recovery Air Handling Units

INTELLIGENT AXIAL FAN user's manual

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

Air handling unit. BlauAir RH USER S MANUAL

Breathe Fresh Air at Home

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

VERSO Air Handling Units

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

AIR HANDLING UNIT WITH HEAT RECOVERY

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

UV-TURBO HOODS. Product Brochure

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5

MECHANICAL VENTILATION

Turbo. Service Instructions

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

COMMERCIAL VENTILATION

IMPORTANT SAFETY INSTRUCTIONS DANGER: WARNING:

ENERGY SAVING VENTILATION GEO VENTS GEOTHERMAL SYSTEMS

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

BATHROOM EXTRACT FANS SILENT-100 Series

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

TURBO HOODS. Product Brochure

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

USER'S MANUAL. Micra 150 HEAT RECOVERY UNIT

Tools required. Pencil Drill Screwdriver Dowel (2 pcs.) Screws (2 pcs.)

Ventilation Unit Zehnder ComfoAir 350

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

KITCHEN EXTRACTORS K Series

CI/SfB (57.5) November 2008

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

VENTILATION UNITS. local ventilation units with heat recovery KORASMART KORASMART KORASMART KORASMART KORAVENT KORAVENT KORAVENT KORAVENT

USER S MANUAL. VKP Series INLINE FAN

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

Flexit air handling units C2 and UNI 2, 3,4

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

Energy Recovery, Wholehouse Ventilation ECO LIVING

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

AIR HANDLING UNITS MANDÍK

Small Room Heat Recovery Ventilation

USER S MANUAL VUT 160 P2B EC A14 VUT 160 PB EC A14 VUT 350 P2B EC A14 VUT 350 PB EC A14 HEAT RECOVERY AIR HANDLING UNIT

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

Caution: The fans must not be used in bath or shower enclosures.

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

Whole Home Heat Recovery Ventilation

With the world-renowned SIGMA PROFILE

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

Mini fans MiniVent M1/100

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

Discover ebm-papst for buildings. Energy-efficient fans for a controlled room atmosphere.

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

Axial intelligent fan USER S MANUAL

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

AC Backward Curved Motorized Impellers

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

Centrifugal inline fans

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

CONTROLLED MECHANICAL VENTILATION

Transcription:

WORLD VENTILATION LEADER IO EM.COM SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS VENTS reserves the rights to modify any of its products featuers, designs, components and specifications at any time and without notice to maintain the development and quality of manufactured goods. 04-2013

WW.VE VENTILATION ON OUR LIFE How much fresh is the air we breathe in? In everyday life, we do not think a lot about how much time we spend in closed spaces houses, offices, office buildings, hospitals, etc. All this time we share limited volume of air of doubtful purity and freshness with our people in the same rooms. Unwellness, weariness, headache and other unpleasant symptoms are the first indicators of negative impact of polluted stale air on human health. Still, we rarely associate these conditions with poor air quality. For human organism, the surrounding air quality has vital importance The ventlight is not a good solution Partially the polluted air problem can be solved be creating natural ventilation through window opening. Ventilation through open windows brings to uncontrolled excessive air flow and creates unsafe draughts. By opening windows you fill the room not with clean air but with a mixture of pollens, poplar stuff, dust and exhaust fumes. Moreover, thermal losses rise together with high energy costs. Furthermore, noise level from outside may be a catastrophe. We har dly make such ventilation useful but we let extra irritants and pollutants enter our rooms and we do not solve the problem of polluted stale air removal In captivity of our own houses... modern houses made of brick and concrete, equipped with double-glazed windows, metal doors, additional outer insulation, etc., are practically hermetic structures. Striving to minimize heat losses and energy costs has resulted in almost perfect insulation of buildings and blocked any possibility of natural air motion and air exchange. The rooms or premises that are thermally well insulated and sealed in plastic windows cannot avoid excessive moisture which provokes formation of various bad smells, including foul smell, feeling of stale air, various pollutants, even mould. Microclimate in this house becomes harmful for its inhabitants and for the house structure, too. THERE IS A SOLUTION! Arrangement of the effective forced supply and exhaust ventilation in the rooms or premises. 2 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 3

SINGLE-ROOM AIR HANDLING UNITS MICRA THE BEST COST-SAVING SOLUTION FOR CREATING OF ENERGY SAVING VENTILATION OF SEPARATE ROOMS IN APARTMENTS, COTTAGES, SOCIAL AND COMMERCIAL PREMISES. CLEAN FRESH AIR SUPPLY TO THE PREMISES STALE EXTRACT AIR REMOVAL FROM THE PREMISE CLEAN AIR FREE OF DUSTAND INSECTS NO EXCESSIVE HUMIDITY AND MOULD SILENT OPERATION HEAT REGENERATION AIR WARMING UP TO SET TEMPERATURE (MICRA 150 E) REDUCING HEATING COSTS IN WINTER AND AIR CONDITIONING COSTS IN SUMMER LOW ENERGY DEMAND NON-STOP OPERATION COST-SAVING The single room air handling units with heat recovery MICRA are the fullyfeatured ready to use ventilation solutions that provide supply of fresh air to the premise, air filtration and extract of polluted air outside and supply air warming up if required (Micra 150 E). MICRA units create an effective and fully-fledged ventilation in your house! ENERGY SAVING AND EFFICIENCY The great advantage of the MICRA single-room air handling units is their ability to recover heat to the premises (up to 92%) due to a specially designed aluminium recuperator. Heat recovery is based on use of extract air heat energy for heating of intake fresh air from outside. In view of permanent heat losses in the room use of heat recovery is the most useful technology for cost and energy saving. VERSATILE The MICRA single room air handling units with heat recovery are applicable at any project stage and suitable for installation in any room where installation of centralized ventilation devices is unfeasible: complex ventilation system for brand new construction; reconstruction of existing buildings and premises; ordinary scheduled repair in ready-made premises. SIMPLE AND EASY TO USE The single room air handling units with heat recovery MICRA have compact sizes and are designed for mounting on outer wall from inside. Two 125 mm through-the-wall openings in the wall is everything you need for mounting. After mounting they are covered with the decorative unit casing. Install a double outer hood on outer side of the wall to prevent direct water ingress and foreign objects inside the unit. MICRA UNITS WILL SUPPLY FRESH AIR WITH MINIMUM ENERGY DEMAND AND SURPRISE YOU WITH THEIR SILENT OPERATION 4 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 5

MICRA 60 OPERATING LOGIC Fresh intake air from outside moves through the filter and the heat exchanger and is supplied to the premise with a supply exhaust fan. Warm stale air from the room moves through the filter and recuperator and then is exhausted outside with an exhaust axial fan. Heat energy of warm stale extract air is transferred to cold intake air flow from outside in the heat exchanger. Heat energy utilization results in reducing heat energy losses and operating costs for heating in cold season. The intake and extract air flows are fully separated and pollutants, odours and microbes contained in extract air are not transmitted to supply air. The single room air handling unit with heat recovery for balanced energy saving single room ventilation of flats, cottages and commercial premises. No need to connect air ducts. Supply filter Extract filter FEATURES Efficient heat recovery ventilation for separate rooms (premises) Plate counter flow aluminium heat exchanger with recuperating efficiency up to 79% EC fans with low energy demand and electrical safe voltage 12 V Integrated automatics with three operation modes Silent operation (22-29 dba) Air cleaning with two G4 built-in filters Easy mounting Suitable for continuous operation Pulser power supply unit for wide range of power supply voltage 100-240 V and frequency 50-60 Hz. Supply air Extract air CONTROL AND OPERATION MODES Automatic system enables three operation modes supply and exhaust ventilation: Heat exchanger (recuperator) 1. Minimum 30 m 3 /h (noise level 22 db(a). 2. Medium 45 m 3 /h (noise level 25 db(a). 3. Maximum 60 m 3 /h (noise level 29 db(a). 6 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 7

MICRA 60 CASING (1) Polymer coated metal casing decorated with mirror stainless steel. 15 mm penophole thermal and sound insulating layer. Modern unit design makes it match well with any interior. Removable front panel provides easy access for the unit servicing, i.e. for filter cleaning or replacement. AIR FILTRATION (2) Two G4 built-in filters provide cleaning of supply and extract air. The filters serve to ensure supply of fresh air free of dust, insects and protect the unit from soiling. CONTROL UNIT (4) The unit is powered through an integrated pulser unit with a wide range of supply voltage from 100 V to 240 V and frequency from 50 to 60 Hz. The power unit has integrated protection circuit for various emergencies including short circuit, overload, voltage jumps, reverse polarity in output circuits. 5 3 1 2 4 AIR SUPPLY AND AIR EXTRACT (3) Axial EC fans provide air supply and air extract. Due to EC technologies the single room air handling unit with heat recovery is featured with low energy demand. The fans are powered by electric safe low voltage 12 V. The fan motors are equipped with built-in thermal overheating protection and ball bearings for longer service life. HEAT EXCHANGER (RECUPERATOR) (5) The unit is equipped with a high-tech plate counter-flow aluminium heat exchanger. Recuperating efficiency reaches 79%. Joint operation of MICRA with air conditioners is considerable cost saving because the recuperator saves heat in winter and cool in summer. FREEZING PROTECTION Unit has integrated freeze protection system. During cooling of extract air some condensate can appear in the unit. To prevent recuperator freezing the unit is equipped with electronic freezing thermostats that switch supply fan off. After that warm stale air warms the recuperator up to required temperature. 8 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 9

MICRA 60 VENTILATION SYSTEM ARRANGEMENT EXAMPLE Install MICRA unit in any room where ventilation is required. One unit provides efficient ventilation for the area up to 24 m 2. Mount the single room air handling unit with heat recovery MICRA on the front wall from inside. The minimum wall thickness is 100 mm. To attain the maximum energy efficiency of a ventilation system based on the Micra 60 units we suggest using it in combination with ifan, which extracts stale air from a bathroom according to the humidity sensor readings. First mark the holes on the wall for the air ducts with the paper master plate (included into delivery set and into MK1 and MK2 set(page 13). After holes are drilled install the plastic air ducts inside the holes. Install the outer hood (included into the MK2 set or purchased separately (NB set)) on outer side of the wall to prevent ingress of water and foreign objects inside the unit. Mount the unit with its branch pipes directed toward the plastic air ducts. The unit is supplied with a pre-wired power cable and a socket. The unit may be connected to the fixed wiring system through terminal leads if required. VENTS ifan MICRA 60 10 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 11

MICRA 60 TECHNICAL DATA ACCESSORIES Model MICRA 60 Speed 1 2 3 Voltage [V/50 Hz] 100-240/50-60 Hz Power [W] 4,2 9,6 15,4 Air capacity [m 3 /h] 30 45 60 Heat recovery efficiency 79% 74% 70% Rotation speed [min -1 ] 1165 1720 2685 Sound pressure level at 3 m distance [dba ] 22 25 29 Ingress protection rating IP22 OVERALL DIMENSIONS [mm] MK1 Micra 60 used to facilitate mounting and ensure correct alignment of the unit branch pipes with the air ducts: two plastic air duct 125 mm 500 mm long; paper master plate (2 pcs). 122 395 181 522 NB Micra 60 outer ventilation kit: double outer metal hood. MK2 Micra 60 mounting kit: two plastic air duct 125 mm 500 mm long; paper master plate; outer ventilation kit NB Micra 60. 12 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 13

MICRA 150 E OPERATING LOGIC The intake air from outside flows through the filter and the heat exchanger and is supplied to the room with the supply centrifugal fan. Warm stale air from the room flows through the filter and the heat exchanger and is exhausted outside through the wall by the exhaust centrifugal fan. In the heat exchanger heat energy of warm extract air from the room is transferred to clean cold air flow from outside. Heat exchange results in minimization of heat losses and lower heating costs. The extract and supply air flows are fully separated, so no contaminations, odours and microbes come to supply air flow. Intake air Expaust air FEATURES Single-room air handing unit with air warming up function. It has easy mounting without air ducts. Extract filter Supply filter Efficient supply and exhaust ventilation of separate premises (rooms) Posistor 350 W air heater with overheating protection Polystyrene plate counter-flow heat exchanger with recuperation efficiency 82-92% EC fans with low energy demand (9 to 40 W) Extract air Heat exchanger (recuperator) CONTROL AND OPERATION MODES Supply air Integrated automation with 3 operation modes (from 60 up to 150 m 3 /h) Silent operation (30-38 dba) Air cleaning with two built-in G4 filters Easy mounting Compact sizes The unit is equipped with a control panel. The delivery set includes a remote control panel. The control system supports the following 3 operation modes: - 1 speed - air capacity 60 m 3 /h and air warming up function; - 2 speed - air capacity 105 m 3 /h and air warming up function; - 3 speed - air capacity 150 m 3 /h and air warming up function. The following functions are available: extra heating of supply air; high speed activation timer adjustable from 20 to 60 minutes; fan speed adjustment; week-scheduled operation; filter replacement and alarm indication. 14 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 15

MICRA 150 E CASING (1) Metal polymer coated casing decorated with mirror-polished stainless steel. 10 mm foamed synthetic rubber layer provides heat- and soundinsulation. The modern unit design let it match well with any interior type. AIR FILTRATION (3) Supply and exhaust air flows are cleaned with two built-in G4 filters. The filters serve to provide supply of fresh air free of dust, pollen, insects and prevent the unit components from soiling. CONDENSATE DRAIN PAN (4) 1 Some condensate that may be generated during heat recovery process is collected in a special drain pan. As the drain pan is filled with condensate, the unit switches automatically off which is confirmed by a light indicator on the control panel. HEAT EXCHANGER (5) 2 3 The unit incorporates a high-tech plate counter-flow polystyrene heat exchanger with heat exchange efficiency 82-92%. In winter period the heat exchanger utilizes heat energy of extract air to warm up intake air and decrease the operating load on the heating system. In summer period supply air is cooled down by colder intake air. 4 5 6 HEATER (6) The unit is equipped with a ceramic heater which is used to warm up supply air up to the comfortable air temperature. Heater is operational economy, fire safety (no overheating), environmental friendliness, self regulation, high electric durability, high specific power, easy and reliable maintenance. The heater efficiency is reaches 90-95%. AIR SUPPLY AND EXHAUST (2) High-efficient EC motors with external rotor and forward curved blades are designed for air supply and exhaust. The fan motors have built-in overheating protection and ball bearings for longer service life. Due to EC technologies Micra 150 E is featured with low energy demand and reliable operation. FREEZING PROTECTION The air handling unit MICRA 150 E is equipped with a built-in freezing protection. The electronic freeze protection is applied to prevent condensate freezing during cold outside temperatures. If exhaust air temperature drops down below the set point, the supply fan is stopped. Warm extract air warms the heat exchanger up and the exhaust air temperature rises. After that the supply fan is turned on and the unit reverts to the previous operation mode. 16 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 17

MICRA 150 E VENTILATION SYSTEM ARRANGEMENT EXAMPLE Install one or several MICRA 150 E unit in each premise to be ventilated. One unit is capable to provide efficient ventilation of up to 60 m 2 area. The air handling unit MICRA 150 E is mounted on a face wall from inside. The wall thickness from 100 mm. First mark the holes for the air ducts with a cardboard master plate included into the delivery set. Insert the air ducts into the holes. Mount a double metal hood on outer wall side to protect the unit from water ingress and outer objects. While mounting the unit direct the branch pipes to the plastic air ducts and fix it to the wall with dowels and screws. The unit is supplied with a prewired power cable and a socket. The unit may be connected to the fixed wiring system through terminal leads.. Micra 150 E Vents ifan 18 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 19

MICRA 150 E OVERALL DIMENSIONS [mm] 500 TECHNICAL DATA Model MICRA 150 E Ventilation mode 1 2 3 Voltage [V] 230/50 Hz Maximum fan power [W] 9 16 40 Heater power [W] 350 1,68 Maximum unit current (including heater operation) [A] Air capacity [m 3 /h] 60 105 150 RPM [min -1 ] 450 780 2000 Noise level at 3 m distance [db(a)] 30 35 38 Heat recovery efficiency 92 87 82 Ingress protection rating IP 22 260 ACCESSORIES 430 155 255 Ø124 580 200 Ø125 Mounting kit MK MICRA 150: two plastic air ducts (Ø 125 mm, length 500 mm); double outer metal hood. 20 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 21

NOTES 22 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 VENTS. Single room air handing unit with heat recovery Мicra 04-2013 23