Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

Similar documents
II. OBJECTIVE OF RESEARCH

Enhancement of COP in Vapour Compression Refrigeration System

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

STUDY OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING DOUBLE PIPE HEAT EXCHANGER

Pressure Enthalpy Charts

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

To Improve Cop of Domestic Refrigerator with the Help of Water Cooling Condenser

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

ISSN Vol.08,Issue.21, November-2016, Pages:

Design & Fabrication of Hybrid Cooler

HVAC Fundamentals & Refrigeration Cycle

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Performance Enhancement of Mini Refrigerator with Phase Change Materials

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Week 9. Refrigeration Cycles I. GENESYS Laboratory

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

Performance investigation of Air-conditioning system using ejector as expansion device

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

Design of LPG Refrigeration System

pdfmachine trial version

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Compendium DES July 2016, CARN

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

Dhulapally, Secunderabad Subject: REFRIGERATION AND AIR CONDITIONING QUESTION BANK

Analysis of Coefficient of Performance & Heat Transfer Coefficient on Sterling Cycle Refrigeration system.

Chapter 10. Refrigeration and Heat Pump Systems

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

VCR SYSTEM USING R-600a/ POE OIL/MINERAL OIL/NANO-SiO 2 AS WORKING FLUID: AN EXPERIMENTAL INVESTIGATION

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

EXPERIMENTAL VERIFICATION OF PERFORMANCE OF CAPILLARY TUBE USING VAPOUR COMPRESSION REFRIGERATION SYSTEM

INSTITUTE OF AERONAUTICAL ENGINEERING

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

Sarthak Thakar, 2 R.P.Prajapati 1

(Refer Slide Time: 00:00:40 min)

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec REFRIGERATION & AIR-CONDITIONING (Mechanical Engineering)

ADVANCES in NATURAL and APPLIED SCIENCES

c Dr. Md. Zahurul Haq (BUET) Refrigeration Cycles ME 6101 (2013) 2 / 25 T270 COP R = Q L

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

Refrigeration Cycles. Refrigerators, Air-conditioners & Heat Pumps. Refrigeration Capacity/Performance. Dr. Md. Zahurul Haq

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

T270 COP R = Q L. c Dr. Md. Zahurul Haq (BUET) Refrigeration Cycles ME 6101 (2017) 2 / 23 T354

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

A Review of Different Types of Combine Cooling System

Thermodynamics II Chapter 5 Refrigeration

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

CH2351 Chemical Engineering Thermodynamics II Unit V Refrigeration. Dr. M. Subramanian

ENSC 388. Assignment #6

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

Waghmare Tushar Ramrao, D.S.Nakate

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

R07. Answer any FIVE Questions All Questions carry equal marks *****

[Jhansi, 5(10): October 2018] ISSN DOI /zenodo Impact Factor

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Performance Assessment of Water Cooled Condenser Refrigeration System

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

JJMIE Jordan Journal of Mechanical and Industrial Engineering

Optimization of Capillary Tube Parameters in Vapour Compression System using Environmentally Friendly Refrigerant R1234yf

Keywords: Climate change; ozone depletion; Montreal protocol; eco-friendly refrigerant; hydrocarbon refrigerant; performance analysis.

UNIT - 3 Refrigeration and Air - Conditioning

An Experimental Study on Clothes Drying Using Waste Heat from Split Type Air Conditioner

Adsorption refrigeration system using waste heat

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Chapter 9. Refrigeration and Liquefaction

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Numerical Simulation of Window Air Conditioner

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

International Journal of Research in Engineering and Innovation Vol-2, Issue-2 (2018),

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

FABRICATION OF REFRIGERANT FLOW RATE WITH SPIRALLY COILED CAPILLARY TUBE


HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

A Survey on Year Round Air Conditioning System in Cars by using Exhaust Gases

Transcription:

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System Sanath Kumar K H 1, Arun Kumara K S 2, Nissar Ahmed 3 Assistant Professor, Department of Mechanical Engineering, VVIT, Bangalore, Karnataka, India 1 P.G. Student, Department of Mechanical Engineering, NMIT, Bangalore, Karnataka, India 2 Principal, Government ITI College, Tumkur, Karnataka, India 3 ABSTRACT:Refrigeration is a process of cooling or reducing the temperature of a substance below that of the surrounding atmosphere and maintaining this lower temperature within the boundary of a given space. To improve the coefficient of performance (COP), it is require decreasing the compressor work and increasing the refrigerating effect. Experimental analysis on vapour compression refrigeration (VCR) system with R134A (tetra fluoro ethane) refrigerant was done and their results were recorded. The effects of the main parameters of performance analysis are mass flow rate of refrigerant, suction pressure of compressor, delivery pressure of compressor, temperature of evaporator and condenser. The result from vapour compression refrigerant plant was taken where the variables like suction pressure of compressor, delivery pressure of compressor, temperature of evaporator and condenser were noted and coefficient of performance (COP) was calculated. The results obtained will be validated through CFD simulation. Further diffuser has been introduced in between compressor and condenser so that power input to the compressor has been reduced there by enhancing COP, the enhancement will be done through CFD simulation. KEYWORDS: Vapour compression refrigeration system, coefficient of performance, suction and delivery pressure of compressor, Super Heating and Sub-Cooling of Liquid. I. INTRODUCTION In thermodynamics, Refrigeration is the major application area, in which the heat is transferred from low temperature to high temperature region. The equipment which produces refrigeration is known as Refrigerator the cycle on which it operates is called refrigeration cycles. Vapour compression refrigeration cycle is most regularly used refrigeration cycle, in which the refrigerant is alternately vaporized and condensed and in the vapour phase it is compressed. GRC is the well-known refrigeration cycle. We know that always heat flows from high temperature medium to low temperature medium. This heattransfer occurs in nature without aid of any External devices. The special devices by which the heat transfers from a low temperature medium to a high temperature medium are called Refrigerators. Heat pump is the device it transfers heat from a low temperature region to a high temperature region. Heat pumps and Refrigerators are basically the same devices; but they are dissimilar in their objectives only. The main objective of a refrigerator is maintaining the refrigerated space at a low temperature by removing heat from it. The main objective of a heat pump is maintaining the heated space at a high temperature. This is capable of absorbing heat from a small-temperature medium. Copyright to IJIRSET DOI:10.15680/IJIRSET.2016.0510084 17879

Fig.1: Refrigerator and Heat pump II. ACTUAL VAPOUR-COMPRESSION REFRIGERATION CYCLE Owing to the frequent irreversibility s that happened in various components, in various ways an AVCR cycle differs from the ideal one. Two general sources of irreversibility s are heat transfer to or from the surrounding and fluid friction (causes pressure drops). Fig.2: AVC Cycle (T-s diagram) Fig.3: Vapour Compression Refrigeration Systems Fig 2 and 3 shows the AVC cycle on T-s diagram and Vapour Compression Refrigeration Systems Process 1-2-3 it shows the refrigerant through evaporator, with 1-2 indicating gain of latent heat of vaporization and2-3. Process 3-4-5-6-7-8 Path 3-4 represents the throttling action that occurs during passage through the suction valves and path 7-8 represents the throttling during passage through exhaust valves. Compression of the refrigerant occurs along the path 5-6, which is actually neither isentropic nor polytrophic. The heat transfer indicated by path 4-5 and 6-7 occurs essentially at constant pressure. Process 8-9-10-11 This process indicates the flow of refrigerant through condenser with 8-9 removal of superheat, 9-10 removal of latent heat, and 10-11 removal of heat of liquid. Process 11-1 it shows flow of refrigerant through the expansion valve both theoretically and practically an irreversible adiabatic path. Copyright to IJIRSET DOI:10.15680/IJIRSET.2016.0510084 17880

A VCR system is an advanced type of air refrigeration system in which a working substance, known as refrigerant, It condenses and evaporates at temperature and pressure close to the atmospheric conditions. The refrigerants usually used for this purpose are NH 3, CO 2 and SO 2 etc. refrigerant used does not leave the system, but it circulates throughout the system alternatively condensing and evaporating. During evaporation, latent heat is absorbs from the brine. The refrigerants used are, NH 3, CO 2, Freon etc. which alternately undergoes condensation and evaporation during the cycle. When refrigerant enters the evaporator it will be in liquid state and by absorbing latent heat it becomes vapour. Thus the C.O.P of this system is always much higher than air refrigeration system. III. EXPERIMENTATION AND METHODOLOGY In the ideal cycle, the refrigerant after leaving the evaporator enters in to the compressor as saturated vapour. However, controlling the state of the refrigerants so accurately is not possible. Instead, it is easy for designing of the system such that the refrigerant is slightly superheated at the compressor inlet. This small overdesign in the system makes sure the refrigerant is totally vaporized when it enters in to the compressor. Also, very long line connects the compressor to the evaporator; thus the drop in pressure caused by heat transfer from the surroundings to the refrigerant and fluid friction can be very important. Fig.4: Refrigeration Test Rig Fig.5: Line Diagram of Vapour Compression Refrigeration System The above fig.4 and 5 shows the liquid refrigerant in the evaporator, absorbs the heat from the medium which to be cooled and undergoes a change of phase from liquid to vapour. The vapour at low temperature and pressure is drawn into the compressor where it is compressed to a high pressure and temperature. The compressed vapour then enters the condenser. Specifications Refrigerator Capacity = 220 litres. Pipe Diameter of the Evaporator =11 mm Length of the Evaporator Coil = 1539 mm Copyright to IJIRSET DOI:10.15680/IJIRSET.2016.0510084 17881

A. EXPERIMENTAL RESULTS Experiments T 1 K Table. 1 EXPERIMENTAL RESULTS T 2 T 3 T 4 Heat Flux W/m 2 K K K K 1 281 333.4 310.1 266.8 1146 2 277.7 334.2 307.1 260.4 1405 3 276.5 334.8 308 259.2 1410 B.OBSERVATIONS OF EXPERIMENTAL RESULTS WILL BE VALIDATED THROUGH CFD Fig.6: Contours of Wall Heat Flux for Experiment 1 The above fig.6 shows the contours of Heat Flux conducted for the Experiment 1 Fig.7:Contours of Wall Heat Flux for Experiment The above Fig.7 shows contours of wall heat flux for the experiment2 Copyright to IJIRSET DOI:10.15680/IJIRSET.2016.0510084 17882

Fig.8:Contours of Wall Heat Flux for Experiment 2 C. ENHANCEMENT OF COP BY PROVIDING DIFFUSER BETWEEN COMPRESSOR AND CONDENSER WITH DIVERGENCE ANGLE OF DIFFUSER Fig.9:Vapour Compression Refrigeration System along with diffuser IV. RESULTS AND DISCUSSION A. GEOMETRY OF DIFFUSER Inner Diameter = 15 mm, Angle of Divergence =10 0,15 0 and 20 0 and Length of Diffuser = 30 mm. Diffuser Angle Selected on the Basis of Reference Paper Fig.10: Meshed and Imported of Diffuser Copyright to IJIRSET DOI:10.15680/IJIRSET.2016.0510084 17883

Fig.10 shows the Meshed Model of the diffuser and Imported from ICEMCFD to CFX for Analysis Fig.11: Outlet Pressure for Diffuser angle 10 0 and 15 0 Fig.12: Pressure Contours for Diffuser angle 20 0 Fig.13: Outlet Temperature for Diffuser angle 10 0 &15 0 For 20 degree flow analysis through the diffuser showed back flow which has been observed from colour coding from negative plot of numerical values which shows that 20 degree diffuser is not an appropriate design for analysis. Without Diffuser Therefore Compressor input = h 2 1 - h 1 Refrigeration effect = h 1 - h 6 For P 1 = 137.89 KPa saturation temp. is t s1 = -19.15 o C. But observed temperature is 8 o C. Therefore the condition of the refrigerant before compression is Superheat. H 1 = h g1 + c p (t sup -t s1 ) = 238.98 + 0.958 (8-(-19.15)) = 264.99 kj/kg Final pressure = P 2 1 = 770 KPa Final Temperature = 348 K = 348 273 = 75 o C. For P 2 1 = 770 KPa saturation temp. is t 3 1 = 29.92 o C. The condition of the refrigerant after compression is Superheat. H 2 1 = h 3 1 + c p (t sup -t 3 1 ) = 266.64 + 0.958 (75-29.92) = 309.83 kj/kg H 6 = h 5 = 93.155 kj/kg COP = Refrigeration Effect / Work Done = (H 1 h 6 ) / (H 2 1 H 1 ) = (264.99 93.155) / (309.83 264.99) = 3.83 Copyright to IJIRSET DOI:10.15680/IJIRSET.2016.0510084 17884

With Diffuser Angle 10 For P 1 = 137.89 KPa saturation temp. is t s1 = -19.15 o C. But observed temperature is 8 o C. Therefore the condition of the refrigerant before compression is Superheat. H 1 = h g1 + c p (t sup -t s1 ) = 238.98 + 0.958 (8-(-19.15)) = 264.99 kj/kg For P 2 = 719.9 KPa saturation temp. is t s2 =26.9 o C. But observed temperature is 60.4 o C. Therefore the condition of the refrigerant after compression is Superheat. H 2 = h g2 + c p (t sup -t s2 ) = 262 + 0.958 (60.4-26.9) = 294.093 kj/kg h 3 = h 4 = 93.155 kj/kg COP = Refrigeration Effect / Work Done = (H 1 h 4 ) / (H 2 H 1 ) = (264.99 93.155) / (294.093 264.99) = 5.90 Enhancement of COP (compared with 10 degree diffuser) = = 0.3508 = 35.08% = (5.90-3.83)/5.9 Sl. No Refrigeration Effect kj/kg Compressor Input kj/kg Table. 2 Calculation Results Power Input to Compressor KW Percentage of Enhancement ofcop 1 without Diffuser 171.84 44.84 0.2 ------ 2 with Diffuser 10 171.84 29.103 0.13 35.08% 3 with Diffuser 15 31% 171.84 30.96 0.14 V. CONCLUSION From above analysis following conclusion has been arrived. With the addition of diffuser pressure inlet of refrigerant to the condenser is increased. With the addition of diffuser of an angle 10 degree Coefficient of Performance (COP) enhancement has been increased by 35.08 % when compared without diffuser. With the addition of diffuser of an angle 15 degree Coefficient of Performance (COP) enhancement has been increased by 31.0% when compared without diffuser. Power input to the compressor obtained with diffuser of 10 degree is 0.13 KW. Power input to the compressor obtained with diffuser of 15 degree is 0.14 KW. Power input to the compressor obtained without diffuser is 0.2 KW. Finally conclusion drawn is Coefficient of Performance (COP) can be enhanced by placing diffuser of 10 degree divergent angle. Finally for 20 degree flow analysis through the diffuser showed back flow which shows that 20 degree diffuser is not an appropriate design for analysis. REFERENCES 1. Amit prakash TO IMPROVE THE PERFORMANCE OF VAPOUR COMPRESSION REFRIGERATION SYSTEM BY USING SUBCOOLING AND DIFFUSER IJEBEA 13-129 2013 2. R. Rejikumar et.al ENHANCEMENT OF HEAT TRANSFER IN DOMESTIC REFRIGERATOR USING R600a/mineral oil/ nano-al2o3 AS WORKING FLUID IJCETR APRIL 2013 VOL 03,ISSUE 04. 3. M. Krishna Prasanna M.E. student, and P.S Kishore ENHANCEMENT OF COEFFICIENT OF PERFORMANCE (COP) IN VAPOUR COMPRESSION REFRIGERATION SYSTEM 4. J.K.Dabas et.al PERFORMANCE CHARACTERISTICS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM UNDER REAL TRANSIENT CONDITIONS 5. Lucia VILCEANU and Mihaela FLORI PERFORMANCE CHARACTERISTICS OF VAPOUR- COMPRESSION SYSTEMS Copyright to IJIRSET DOI:10.15680/IJIRSET.2016.0510084 17885

6. R.T.Saudagar and Dr. U.S. Wankhede INTRODUCING DIFFUSER AT COMPRESSOR INLET IN A VAPOUR COMPRESSION REFRIGERATION SYSTEM 7. P.Thangavel SIMULATION ANALYSIS OF COMPRESSION REFRIGERATION CYCLE WITH DIFFERENT REFRIGERANTS 8. A. Baskaran and P.Koshy Mathews THERMAL ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R152a and its blends R429A, R430A, R431A, and R435A. Copyright to IJIRSET DOI:10.15680/IJIRSET.2016.0510084 17886