Operator's Handbook. Interactive Fire Alarm System Release 3. Information Panel, BV-320. Protecting life, environment and property...

Similar documents
Operator's Handbook. Release 3. Fire Alarm Control Panel, BS-310 / 320 / Operator Panel BS-330. System Program Version 3.8.0

Installation Handbook. Interactive Fire Alarm System Release 3. Operator Panel, BS-330. Protecting life, environment and property...

Shortform Configuration Guide

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

CSP-204 CSP-208 CSP-104 CSP-108

Instructions AutroFlame IR Flame Detector BG-201/BG-21

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

U ser's Guide PC6010

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Intelligent Security & Fire Ltd

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Intelligent Security & Fire Ltd

user manual Document No , Revision 03 November 2015

Document No Issue 4 user manual

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

BS-100 DYFI. Installation handbook. Protecting environment, life and property... P-BS100/DCE

Panel Functions & Indicators - Key to Icons General & Zone Fire LEDs ACCEPT SOUNDERS START/ STOP RESET BUZZER MUTE KEYSWITCH DELAY ON/OFF ITEM SELECT

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

ZP2 Series Operation Manual

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

Manual# User s Manual. 200 Series. DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel

ID2000. operating manual

System Description AutroMaster V Presentation System

ZERIO PLUS EDA-Z5008, Z5020 & Z5100

Installation, Operating and Maintenance Manual

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

KFP-CF Series Operation Manual

Watchguard WGAP864 User Manual

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

FiRe mobile-2 Operation Manual

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

Fire Alarm Control Panel. System Maintenance and Log Book

The EN54 Part 2 & 4 Fire System

HS-5100, HS-5200, HS-5400 ANALOGUE ADDRESSABLE CONTROL PANELS. User Manual. Approved Document UI-ELAN-02 Revision 03

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

SINGLE MONITORED INPUT UNIT BN-303

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

The EN54 Part 2 and 4 Fire System

SYSTEM 5000 USER MANUAL

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

Fire Command Keypad. XR5 User s Guide

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3

Control Panel User Guide (TO BE RETAINED BY THE USER)

EN 54-2 EN 54-4 EN CPD CPD CPD-0230

ZSC100 Gas Detection and Alarm System Controller

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

JA-63 Profi User manual

Manual# User s Manual. DCU 410/408 Engine Control Unit RP 410 Remote Panel FW 2.3

ZP3 Operator & Maintenance Manual Version 1

Easy Reliable Flexible. Interactive fire detection system

Version 1.03 January-2002 USER S MANUAL

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

Summit 3208GLD USER MANUAL. Electronics Line

Contents. Glossary

M800, M800iD Plus, M1000 and M3000. User's Guide

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

SFC-200 SERIES LED FIRE ALARM PANEL

CONTROL AND INDICATOR MODULE. Potok-BKI INSTRUCTION MANUAL

FA-300 Series. LED Fire Alarm Control Panel. User Guide. FA-300 SERIES Fire Alarm Control Panel. FA-300 SERIES Fire Alarm Control Panel

The EN54 Part 2, 4 and 13 Fire System

8 plus and16 plus. User s Guide * # ent. esc GALAXY 16+ V2.XX TUE 30 JUN. IU ZST 962 Issue 2. A u B u

Control Panel User Guide

Simplex Panel Interface Guide

FT2011 Floor repeater display Operation Manual

Tebis application software

FT2010 Floor repeater terminal Operation Manual

Security System. User s Guide for the Text Command Center

HARDWIRED CONTROL PANELS

EXTINGUISHING AGENT RELEASE MODULE

THANK YOU FOR VOTING TEXECOM THANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels 1 INS167

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT. BU-110 and BV-110 Loop Based Displays

Scimitar user manual & log book. Petersfield Business Park, Bedford Rd, Petersfield, Hampshire GU32 3QA Tel: Fax:

Simon XTi Quick Operation Guide

Section 9 System Operation

Mounting Instructions Adapter for ventilation duct BWP-143A-SS, Stainless Steel version

3 User s settings. 3.3 Internal clock setting

External Wireless Sounder

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

2000 Series. Program Entry Guide. Control Panels

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

USER MANUAL & MAINTENANCE GUIDE OG OO

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

Entero Voice Alarm system.

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1

Section 8 System Operation

Table of Contents. Appendix A Special Characters 31

SCAN200E USER S MANUAL

Security System. User Guide for the LED Command Center

HARDWIRED CONTROL PANELS

FieldServer Driver - Serial FS Notifier NCA

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

AutroFlame X33AF. Addendum. Multi-spectrum IR flame detector. Protecting life, environment and property...

Transcription:

Interactive Fire Alarm System Release 3 Operator's Handbook Information Panel, BV-320 Protecting life, environment and property... ASAFE-IN/FE Rev. A, 010531

COPYRIGHT This publication, or parts thereof, may not be reproduced in any form, by any method, for any purpose. and its subsidaries assume no reponsibility for any errors that may appear in the publication, or for damages arising from the information in it. No information in this publication should be regarded as a warranty made by Autronica Fire and Security. The information in this publication may be updated without notice. Product names mentioned in this publication may be trademarks. They are used only for identification.

Table of Contents Table of Contents 1. Introduction... 3 1.1 About the Manual...3 1.2 The Reader...3 1.3 Reference Documentation...3 2. The Information Panel - Overview... 4 2.1 Introduction...4 2.2 Indication Devices...5 2.2.1 Upper Section...5 2.3 The Display...6 2.4 Front Push Buttons...7 2.4.1 Front Push Buttons...7 2.5 Internal Buzzer...8 3. Operation Mode... 9 3.1 Introduction...9 3.2 Conditions in Operation Mode...9 3.3 Alarm Levels...10 3.4 Access Levels...10 3.5 How Events are Presented in the Display...11 3.6 Resounding the Internal Buzzer...11 4. About «In the Event of.»... 12 5. In the Event of a Fire Alarm... 13 5.1 Indications in the Event of a Fire Alarm...13 5.2 Actions to be Taken in the Event of a Fire Alarm...14 6. In the Event of a Fire Alarm - with Alarm Delay... 15 6.1 Indications - Fire Alarm with Alarm Delay...15 6.2 Actions to be Taken - Fire Alarm with Alarm Delay...16 7. In the Event of a Fire Warning... 18 7.1 Indications in the Event of a Fire Warning...18 7.2 Actions to be Taken in the Event of a Fire Warning...19 8. In the Event of Faults... 20 8.1 Indications in the Event of Faults...20 8.2 Actions to be Taken in the Event of Faults...21 Page 1

Table of Contents 9. Index... 23 10. Figure List... 24 11. Reader s Comments... 27 Page 2

Introduction 1. Introduction 1.1 About the Manual This manual is intended to provide the information necessary to read and intepret the visual and audible information given by the Information Panel, BV-320, used in the AutroSafe Interactive Fire Alarm System. 1.2 The Reader The handbook is intended to be used by the fire brigade and personnel who are responsible for operating the system, plus the general public. 1.3 Reference Documentation In addition to this manual, the AutroSafe Interactive Fire Alarm System consists of the following manuals: Handbook System Specification Installation Handbook, Fire Alarm Control Panel (BS-310/320) / Controller (BC-320) Installation Handbook, Operator Panel (BS-330) Installation Handbook, Repeater Panel (BU-320) / Information Panel (BV-320) Installation Handbook, Battery Cabinet (SY-310) Commissioning Handbook Operator s Handbook, Fire Alarm Control Panel (BS-310/320) / Operator Panel (BS-330) Operator's Handbook, Repeater Panel (BU-320) Shortform User Guide Shortform Configuration Guide (for the AutroSafe Demo Board) Wall Chart Wall Chart Menu Structure User Guide, Loop Diagnostic Tool, AS-2000 User Guide, Loop Simulator Tool User Guide, Loop Calculator Tool User Guide, Merge Tool User Guide, Power Calculator Sheet Item Number P-ASAFE/XE P-ASAFE-FA/DE P-ASAFE-OP/DE P-ASAFE-RI/DE P-ASAFE-BC/DE P-ASAFE/EE P-ASAFE-FO/FE P-ASAFE-FB/FE P-ASAFE-SH/LE P-ASAFE-SH/VE P-ASAFE-WE/LX P-ASAFE-CH/LX P-ASAFE/MX P-ASAFE-AS/FE P-ASAFE-LS/FE P-ASAFE-LC/FE P-ASAFE-MT/FE P-ASAFE-PC/FE Page 3

The Information Panel - Overview 2. The Information Panel - Overview 2.1 Introduction The Information Panel is intended to give additional information related to the defined Operation Zone(s). Information Panels are distributed throughout the system to give the general public information related to fire alarm situations. The panels serve as indication devices only. The panel can display minimum information on fire alarms, warnings, faults, disablements and tests. No further details are available. Each of the conditions are presented in a separate condition window, in one mode only. Each panel offers a MORE EVENTS button for scrolling through pages of information related to the selected condition window, if there are more events than the display can show. The MUTE PANEL button is used to silence the internal buzzer. The NEXT WINDOW button is used to step to the next window (only windows with active information are displayed). After all windows have been shown, the first window is displayed. When a timeout on no operation has been ended, the highest prioritized window is displayed. A LAMP TEST button is used for testing the LED indicators. All indicators are lit for 5 seconds, and the LCD (display) will turn all white, then all black. ALARM INFORMASJONSPANEL AUTROSAFE SelfVerify Fault Function Disabled Function Delayed Test Power More Events Mute Panel Next Window Lamp Test Page 4

The Information Panel - Overview 2.2 Indication Devices 2.2.1 Upper Section Text Display - See chapter 2.3. ALARM The red alarm indicator shows that one or more detection zones within the operating zone of the Information Panel are in the fire alarm state. Blinking red light: In the event of a fire alarm. The Fire Alarm Devices (FAD) are still in active state. Steady red light: All FADs activated by the fire alarm condition have been deactivated by operating the Silence Alarms button. The control and indicating equipment still remain in the fire alarm condition. ALARM Fault Function Disabled Function Delayed Test Power More Events AUTROSAFE SelfVerify INFORMASJONSPANEL Mute Panel Next Window Lamp Test Fault The yellow Fault Warning indicator shows the presence of a fault within the operation zone of the Information Panel. Blinking light Unaccepted fault warnings exist. Steady light All fault warnings are accepted. Function Disabled Steady yellow light when one or more of the following components within the operation zone of the Information Panel are in the disabled state: function delayed individual points detection zones alarm zones Fire Alarm Devices, Fire Alarm Routing Equipment, Fire Protection Equipment and Fault Warning Routing Equipment. More Events In the event of more than one alarm. The red More Events indicator shows that several detection zones within an operating zone are in the fire alarm state. Blinking red light: In the event of a fire alarm. The Fire Alarm Devices (FAD) are still in active state. Steady red light: The Silence Alarms button has been pressed. All FADs activated by the fire alarm are no longer active. The control and indicating equipment still remain in the fire alarm condition. Function Delayed Steady yellow light indicates that a delay period is active for Fire Alarm Devices (FAD) or Fire Alarm Routing Equipment (FARE). Configurable. Test Steady yellow light indicates that the system or part of it is in Test Mode. Power Steady green light when power is ON. Page 5

The Information Panel - Overview 2.3 The Display During Normal Operation, the back light in the display is always on. The display has 16 lines of 40 characters and is divided into several display windows showing different types of information. Header FIRE ALARMS 1 OFFICES Detection Zone(s) Time Total number of fire alarms Figure 2-2: The Display Page 6

The Information Panel - Overview 2.4 Front Push Buttons ALARM AUTROSAFE SelfVerify 2.4.1 Front Push Buttons INFORMASJONSPANEL Mute Panel (black) Fault Function Disabled Function Delayed Test Power More Events Mute Panel Next Window Lamp Test Next Window (red) More Events (black) Lamp Test (green) Front Push Buttons Button Designation Access Level Mute Panel (black) Used to mute the panel. Timeout. 1 Next Window (red) Used to step to the next condition window (only windows with active information are displayed). 1 Lamp Test (green) Used for testing the LED indicators. All indicators are lit for 5 seconds, and the LCD (display) will show a pattern to verify all pixels. 1 v More Events (black) Used to scroll pages of information related to the selected condition window. 1 Page 7

The Information Panel - Overview 2.5 Internal Buzzer Each Information Panel provides a buzzer which is activated as described below. Each condition may have its own sound pattern. If more than one condition is present simultaneously, the state of the panel and the buzzer signal will be decided. The buzzer will reflect the condition which has the highest priority. The internal buzzer is controlled by hardware. It is activated in the cases of: System Fault Alarm Prealarm Fault Early Warning (not yet implemented) The buzzer can be silenced by pressing the Mute Panel button. One exception is the buzzer signal indicating System Fault which can not be silenced. If the reason for the buzzer signal still exists, the buzzer will resound after a predefined time. Page 8

Operation Mode 3. Operation Mode 3.1 Introduction The Information Panel operates in Operation Mode, and will automatically enter this mode after startup. The display may look as follows in the panel s idle state. Total: 3 AUTROSAFE SelfVerify Figure 3-1: The idle display Note that if the system is in several conditions at the same time, only one condition - the one with the highest priority - is shown in the display. 3.2 Conditions in Operation Mode In Operation Mode, the system can be in quiescent condition (lowest priority), or the system can be in one or any combination of several conditions. The table below shows the different conditions, and if / how the conditions are indicated on the Information Panel. Conditions fire alarm condition (highest priority) fire warning condition (including prealarm) fault warning condition disablement condition Included in disablement: Immediate actioning disabled condition Indication on display Yes. Indicators that are lit (see also chapter 2.2) ALARM indicator and Fire Brig. Signalled indicator. More Events indicator if more than one fire alarm. Yes. No indicators are lit - no indication. Yes. Yes. Yes. Fault indicator. Function Disabled indicator. Function Delayed indicator test condition Yes. Test indicator. Page 9

Operation Mode 3.3 Alarm Levels A detector may signal different levels of alarm, indicating the amount of smoke or gas currently present. These are; Fire Alarm Level (the highest level) Fire Warning, including: - Prealarm Level - (the lowest level Early Warning is not yet implemented) Whenever a detector detects a transition from one alarm level to another, this event is reported to the system as an Early Warning (not yet implemented), Prealarm or Fire Alarm signal, which in turn will initiate the appropriate actions. 3.4 Access Levels All user interface controls are classified as belonging to different access levels. To operate the Information Panel, Access Level 1 is required. Access Level Access Remedy Description 1 No key or password required. Accessible by members of the general public. All mandatory indications are visible at access level 1 without prior manual intervention. 4 Mechanical tool. Accessible by persons doing repair work and changing firmware. Page 10

Operation Mode 3.5 How Events are Presented in the Display The different events, for example, «In the Event of a Fire Alarm», are presented. FIRE ALARMS, for example, is shown in the upper left corner of the display. The example below shows a situation where three zones are in alarm state. The total number of zones in alarm is shown in the upper right corner. Header FIRE ALARMS 1 OFFICES 2 CANTEEN 3 WORKSHOP Detection Zone(s) in fire alarm Total: 3 Time Total number of fire alarms Figure 3-2: How events are presented 3.6 Resounding the Internal Buzzer After pressing the MUTE PANEL button in an alarm condition, the internal buzzer will automatically be resounded in the following cases: if any new event occurs (for example, a detection zone enters the Fire Alarm state) after a timeout period if the cause for making it sound is still present. Page 11

About «In the Event of.» 4. About «In the Event of.» The subsequent chapters - In the event of..- deal with different events that may occur; Chapter Chapter 5 Chapter 6 Chapter 7 Chapter 8 In the event of.. a fire alarm a fire alarm with alarm delay (in a Delayed Action detection zone - immediate output actioning disabled) a fire warning faults The operational information included in chapter 3, plus the overview of buttons and indicators in chapter 2, are intended to provide the information necessary to interpret the information shown on indicators and in the display, plus the audible indication. As the Information Panel is an indication device, i.e. "read only", all alarm handling is performed by means of the Fire Alarm Control Panel (BS-320), the Operator Panel (BS-330) or the Repeater Panel (BU- 320). Therefore, the following descriptions include only details on how the Information Panel's display, indicators and audible indication changes during the alarm handling. For each event there is an overview of all indications on the panel. In addition, each event deals with the necessary actions to take - which besides general precautions described in the local fire instructions - are limited. All display pictures shown in the subsequent chapters are based on the following: The examples show a system that is configured to immediately trigger Fire Alarm Routing Equipment and send a message to a Fire Receiving Station (Fire Brigade) in the event of a fire alarm. The table for the different procedures is divided into four columns with the following headings; Step Actions to be taken Display Indication Audible Indication Page 12

In the Event of a Fire Alarm 5. In the Event of a Fire Alarm 5.1 Indications in the Event of a Fire Alarm One or several fire detectors or manual call points in one or several detection zones are signalling a Fire Alarm. The following shows the indications on the Information Panel in the event of «Fire Alarm» within the operation zone of the panel. The text display indicates the detection zones in alarm state and their location. The red Alarm indicator is blinking. ALARM INFORMASJONSPANE L Fault Function Disabled Function Delayed Test Power More Events Mute Panel Next Window Lamp Test The internal buzzer is activated. Default pattern on the sound: 1 sec. ON, 1 sec. OFF Activated functions: A message is sent to the Fire Brigade. The fire alarm condition activates Fire Alarm Devices (sounders and visual indicators). Page 13

In the Event of a Fire Alarm 5.2 Actions to be Taken in the Event of a Fire Alarm Step Actions to be taken Display Indication Audible Indication 1 Follow all precautions described in the local fire instructions, step by step. Comments: 2 To silence the internal buzzer, press the black Mute Panel button 3 Observe the zone(s) in alarm state in the display. Investigate the scene(s) and carry out the necessary actions. Comments: FIRE ALARMS 1 OFFICES 2 CANTEEN 3 WORKSHOP Total: 3 All fire alarm devices connected to the alarm zones (which are connected to the detection zones in alarm) are activated (sounders and visual indicators). The internal buzzer on the Information Panel is turned on. The red FIRE indicator starts to blink. When several zones are in alarm state, the More Events indicator is lit. FIRE ALARMS 1 OFFICES 2 CANTEEN 3 WORKSHOP FIRE ALARMS 1 OFFICES 2 CANTEEN 3 WORKSHOP Total: 3 Total: 3 In this example, a total of 3 zones are in alarm state. The internal buzzer on the Information Panel is turned off. Further alarm handling is performed by means of BS-320/330 or BU-320. The Information Panel's display, indicators and audible indication will be affected as follows: Display Indication Audible Indication When the alarms have been silenced: FIRE ALARMS 1 OFFICES 2 CANTEEN 3 WORKSHOP Total: 3 All Fire Alarm Devices (FAD) are deactivated. The red FIRE indicator goes steady. When the system has been reset: The alarm zones are automatically resounded to their alarm states on timeout of the silence resound timer. When the fire is extinguished and all necessary repair work have been carried out (smoke is exhausted, new glass replaced in the manual call-points, etc.), the system should be returned to normal operating mode. AUTROSAFE SelfVerify If there are no points signalling a fire alarm, the system is reset. The red FIRE indicator goes off. The panel enters its idle state. The audible indicator on all panels within the operation zone of the Information Panel is turned off. Comments: If there are points still signalling an alarm when the system is reset, and no actions are taken, the points still signalling alarm will automatically be reactivated after a predefined timeout. The display will indicate fire alarm as described in step 1. If the point(s) still signalling alarm are disabled, the panel will enter its idle state. Page 14

In the Event of a Fire Alarm - with Alarm Delay 6. In the Event of a Fire Alarm - with Alarm Delay 6.1 Indications - Fire Alarm with Alarm Delay A point set to Delayed Action (configurable) is sending an alarm signal from a Delayed Action detection zone in a situation where Immediate Output Actioning has been disabled, i.e. the alarm delay has been activated. NOTE: An alarm from a manual call-point is normally configured to give immediate actioning on the alarm outputs even though Immediate Output Actioning has been disabled. The following shows the indications on the Information Panel in the event of «Fire Alarm with Alarm Delay» within the operation zone of the panel. The text display indicates the detection zones in alarm state and their location. The red Alarm indicator is blinking. The Function Disabled indicator has a steady yellow light. The Function Delayed indicator has a steady yellow light. ALARM Fault Function Disabled Function Delayed Test Power More Events INFORMASJONSPANE L Mute Panel Next Window Lamp Test The internal buzzer is activated. Default pattern on the sound: 1 sec. ON, 1 sec. OFF Page 15

In the Event of a Fire Alarm - with Alarm Delay 6.2 Actions to be Taken - Fire Alarm with Alarm Delay Step Actions to be taken Display Indication Audible Indication 1 Follow all precautions described in the local fire instructions, step by step. FIRE ALARMS 1* KITCHEN FIRST DELAYED OUTPUTS ACTIVATES 19:30 The internal buzzer on the Information Panel is turned on. Comments: 2 To silence the internal buzzer, press the black Mute Panel button The red FIRE indicator starts to blink. The FUNCTION DELAYED and FUNCTION DISABLED indicators have a steady yellow light indicating that Immediate Output Actioning has been disabled (manual operation in Menu Mode by means of the Fire Alarm Control Panel BS-320 or the Operator Panel BS-330). In this example, one point in a Delayed Action detection zone is signalling an alarm. FIRE ALARMS 1* KITCHEN FIRST DELAYED OUTPUTS ACTIVATES 14:40 The internal buzzer on the Information Panel is turned off. 3 Observe the zone(s) in alarm state in the display. Investigate the scene(s) and carry out the necessary actions. 4 If there really is a fire, activate the nearest manual call-point. Comments: FIRE ALARMS 1* KITCHEN FIRST DELAYED OUTPUTS ACTIVATES 14:40 FIRE ALARMS 1 KITCHEN If a manual call-point is activated, all fire alarm devices within the operation zone of the Information Panel (sounders and visual indicators) are activated. Further alarm handling is performed by means of BS-320/330 or BU-320. The Information Panel's display, indicators and audible indication will be affected as follows: Further indication will depend on whether or not there really is a fire. Display Indication Audible Indication If there is not a fire, and the system has been reset: AUTROSAFE SelfVerify The red FIRE indicator goes off.. The panel enters its idle state. All Fire Alarm Devices (FAD) are deactivated. If there really is a fire, and the alarm has been activated by means of the nearest manual call-point or the nearest operator panel (BS-320/330): FIRE ALARMS 1 KITCHEN All fire alarm devices within the operation zone of the Information Panel (sounders and visual indicators) are activated. Comments: The red Fire Brigade Signalled indicator is lit. If the delay time expires, all fire alarm devices within the alarm zones assigned to the actual detection zones (sounders and visual indicators) will automatically be activated. Page 16

In the Event of a Fire Alarm - with Alarm Delay Step Actions to be taken Display Indication Audible Indication When the alarms have been silenced: FIRE ALARMS 1 KITCHEN All Fire Alarm Devices (FAD) are deactivated. The red FIRE indicator goes steady. When the system has been reset: The alarm zones are automatically resounded to their alarm states on timeout of the silence resound timer. When the fire is extinguished and all necessary repair work have been carried out (smoke is exhausted, new glass replaced in the manual call-points, etc.), the system should be returned to normal operating mode. AUTROSAFE SelfVerify The red FIRE indicator goes off. The panel enters its idle state. The audible indicator on all panels within the operation zone of the Information Panel is turned off. Page 17

In the Event of a Fire Warning 7. In the Event of a Fire Warning 7.1 Indications in the Event of a Fire Warning A fire detector in one of the detection zones has entered Fire Warning state (Prealarm or Early Warning). The following shows the indications on the Information Panel in the event of Fire Warning (Prealarm or Early Warning) within the operation zone of the panel. The text display indicates the number of detection zones/detectors in this state, plus their location. ALARM INFORMASJONSPANE L Fault Function Disabled Function Delayed Test Power More Events Mute Panel Next Window Lamp Test The internal buzzer is activated. Default pattern on the sound: 0,5 sec. ON, 3,5 sec. OFF Activated functions: The Fire Warning state will not activate Fire Alarm Devices (sounders and visual indicators). Page 18

In the Event of a Fire Warning 7.2 Actions to be Taken in the Event of a Fire Warning Step Actions to be taken Display Indication Audible Indication 1 Follow all precautions described in the local fire instructions, step by step. FIRE WARNINGS PREALARMS 2 CANTEEN Total : 1 The internal buzzer on the Information Panel is turned on. 2 To silence the internal buzzer, press the black Mute Panel button FIRE WARNINGS PREALARMS 2 CANTEEN Total : 1 The internal buzzer on the Information Panel is turned off. 3 Observe the fire warnings in the display. Investigate the scene(s) and carry out the necessary actions. Comments: 4 If there really is a fire, activate the nearest manual call-point. Comments: FIRE WARNINGS PREALARMS 2 CANTEEN Total : 1 In this example, only one zone is in Prealarm state (2 CANTEEN is blinking). FIRE WARNINGS PREALARMS 2 CANTEEN Total : 1 If a manual call-point is activated, all fire alarm devices within the operation zone of the Information Panel (sounders and visual indicators) are activated. Further alarm handling is performed by means of BS-320/330. The Information Panel's display, indicators and audible indication will be affected as follows: When the Fire Warning(s) (Prealarm) has been accepted: Display Indication FIRE WARNINGS PREALARMS 2 CANTEEN Total : 1 The fire warning (Prealarm) is no longer blinking in the display. Audible Indication All Fire Alarm Devices (FAD) are deactivated. Comments: When the system has been reset: In this example, only one zone is in Prealarm state. If there are several fire warnings, each one has to be accepted in turn by means of the BS-320/330. Fire warnings that are accepted, will no longer blink in the display. This allows you to see on the screen whether a detection zone in Fire Warning state is accepted or not. When the situation is under control (smoke is exhausted, new glass replaced in the manual call-points, etc.), the system should be returned to normal operating mode. AUTROSAFE SelfVerify The panel enters its idle state. The audible indicator on all panels within the operation zone of the Information Panel is turned off. Page 19

In the Event of Faults 8. In the Event of Faults 8.1 Indications in the Event of Faults A fault is indicated by one of the components (fire detectors, external equipment or other faults). The following shows the indications on the Information Panel in the event of Faults within the operation zone of the panel. Blinking light Unaccepted fault warnings exist. Steady light All fault warnings are accepted. The text display indicates the nature of the fault. ALARM INFORMASJONSPANEL AUTROSAFE SelfVerify The green Power indicator is turned off in case of loss of power. Fault Function Disabled Function Delayed Test More Events Mute Panel Next Window Power Lamp Test The internal buzzer is activated. Default pattern on the sound: System: constantly ON. Fault: 0,5 sec. ON, 3,5 sec. OFF Power Fault: 0,75 sec. ON, 3,25 sec. OFF Activated functions: - The output line from the control and indication equipment is activated. Page 20

In the Event of Faults 8.2 Actions to be Taken in the Event of Faults Step Actions to be taken Display Indication Audible Indication 1 Notify service/technical personnel. FAULT WARNINGS DZ FAULTS 1 OFFICES OTHER FAULTS 1 LOOP (2) Total: 2 The internal buzzer on the Information Panel is turned on. Comments: 2 To silence the internal buzzer, press the black Mute Panel button The yellow FAULT indicator starts to blink. FAULT WARNINGS DZ FAULTS 1 OFFICES OTHER FAULTS 1 LOOP (2) Total: 2 The internal buzzer on the operator panel is turned off. Comments: 3 Observe fault warnings in the display. Make service/technical personnel investigate the scene(s) and carry out the necessary actions. Comments: NOTE: An audible indication of loss of POWER can not be silenced. NOTE: The internal buzzer is automatically resounded for each newly recognized fault. FAULT WARNINGS DZ FAULTS 1 OFFICES OTHER FAULTS 1 LOOP (2) Total: 2 In this example, points in detection zone (1 OFFICES) are in fault warning state. Both the detection zone and the related loop (Loop Driver Module BSD- 310), are registered as fault warnings (Total 2). Further alarm handling is performed by means of BS-320/330. The Information Panel's display, indicators and audible indication will be affected as follows: Display Indication Audible Indication When all fault have been accepted: Comments: AUTROSAFE SelfVerify Fault warnings that are accepted, will no longer blink in the display. This allows you to see on the screen whether a fault warning is accepted or not. A fault that has been repaired is indicated with a star on the display (for example, 1*OFFICES). When all fault warnings are accepted, the yellow Fault indicator will switch from blinking to steady light. If all faults are repaired and accepted, the panel will enter its idle state. If all fault warnings are accepted, but one or several faults are still not repaired, the panel will return to its idle state as soon as the remaining faults are repaired. In some cases it may be necessary to reset the system to remove fault warnings. If the system detects any irregularity on the loop topology (for example, two detectors have changed places or are removed), the panel will enter its idle state as soon as the detectors are in placed in their correct positions according to the configuration. Page 21

In the Event of Faults Page 22

Index 9. Index access levels, 10 buzzer, 8 conditions, 9 Early Warning, 18 Faults, 20 Fire Alarm, 13 Fire Alarm with Alarm Delay, 15 Fire Warning, 18 In the event of..-, 12 levels of alarm, 10 menu display, 6 Mute Panel, 7 Operation Mode, 9 Prealarm, 18 Reset System, 7 Silence Alarms, 7 Page 23

Figure List 10. Figure List Figure 2-1: The Display...6 Figure 3-1: The idle display...9 Figure 3-2: How events are presented...11 Page 24

Page 25

Reader s Comments 11. Reader s Comments Please help us to improve the quality of our documentation by returning your comments on this manual: Title: Operator's Handbook, Information Panel, BV-320 AutroSafe Interactive Fire Alarm System, Release 3 Ref. No.: ASAFE-IN/FE Rev. A, 010531 Your information on any inaccuracies or omissions (with page reference): Please turn the page

Reader s Comments Suggestions for improvements Thank you! We will investigate your comments promptly. Would you like a written reply? Yes No Name: ------------------------------------------------------------------------------------------------ Title: ------------------------------------------------------------------------------------------------ Company: ------------------------------------------------------------------------------------------------ Address: ------------------------------------------------------------------------------------------------ ------------------------------------------------------------------------------------------------ ------------------------------------------------------------------------------------------------ Telephone: ------------------------------------------------------------------------------------------------ Fax: ------------------------------------------------------------------------------------------------ Date: ------------------------------------------------------------------------------------------------ Please send this form to: N-7483 Trondheim Norway Tel: + 47 73 58 25 00 Fax: + 47 73 58 25 01 www.autronicafire.com/

is an international company, based in Trondheim, Norway and has a world-wide sales and service network. For more than 40 years Autronica s monitoring systems have been saving lives and preventing catastrophes on land and at sea. Autronica Fire and Security s most important business area is fire detection & security. Autronica Fire and Security stands for preservation of environment, life and property. Quality Assurance Stringent control throughout Autronica Fire and Security assures the excellence of our products and services. Our quality system conforms to the Quality System Standard NS-EN ISO 9001, and is valid for the following product and service ranges: marketing, sales, design, development, manufacturing, installation and servicing of: fire alarm and security systems petrochemical, oil and gas instrumentation systems for monitoring and control In the interest of product improvement, Autronica Fire and Security reserves the right to alter specifications according to current rules and regulations. Fire and Security, Trondheim, Norway. Phone: + 47 73 58 25 00, fax: + 47 73 58 25 01. Oil & Gas, Stavanger, Norway. Phone: + 47 51 84 09 00, fax: + 47 51 84 09 99. Autronica Industrial Ltd., Watford, United Kingdom. Phone: 1923 23 37 68, fax: 1923 22 55 77. Visit Autronica Fire and Security's Web site: http://www.autronicafire.com/