Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

Similar documents
Air distribution systems. Opticlean OC-Q...

Air distribution systems. Opticlean OC-Q... DS 4136 E /1

Ceiling displacement outlet non-adjustable Q-DN... adjustable Q-DV...

Air distribution systems. Rectangular displacement outlet VA-RN... with adjustment device VA-RV...

Rectangular displacement outlet VA-RN... with adjustment device VA-RV...

Ceiling diffusers. Type DLQL

Krantz. HVAC systems for hospitals. System solutions

Ceiling swirl diffusers

Ceiling swirl diffusers

Cleanroom systems. Supply air ceiling and recirculated air ceiling OP. for operating rooms with low-turbulence displacement flow

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Krantz. Multifunction exposed ceiling AVACS. Cooling and heating systems

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

Units for suspended ceilings

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

Static cooling ceiling system SKS-4/3 DS 4094 E /1. Technical Selection

Units for suspended cei lings

Displacement air outlets Low-turbulence air flow in the industrial sector. Air distribution systems

C o o l i n g a n d h e a t i n g s y s t e m s

Air distribution systems. Air distribution systems for assembly rooms

CONDOR. Supply air ceiling QUICK FACTS

Technical Concept. Ultraflex Ceiling Grid (UFR) All Types Cleanroom Ceiling Systems

Halton Rex 600 Basic R6B - Active chilled beam

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

Ultraflex Ceiling Grid (UFR)

Air distribution systems. Ceiling air outlets Turbulent mixing air flow

Recirculated air ceiling for operating rooms made by Krantz Components

KLIMA Active Chilled Beams

Air distribution systems. Displacement air outlets Low-turbulence air flow in the commercial sector

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

Air Shower TECHNICAL DATA

FAN COIL UNITS. The optimal solution for limited space

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

Fan Coil Unit CULTRA

Modular Wall-, door- and CEIlInGSyStEM. Premium quality customized room concepts directly from the manufacturer.

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

DATA & FACTS Clean Rooms DencoHappel Air Shower. Active Air Shower for Personnel in Clean Rooms

Polaris-I-60. active chilled beam. the future of space conditioning

Halton Rex for Vario R6O - Variable air volume chilled beam

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

Cooling Strip Model SPB

KOMFORT EC DB Suspended heat recovery air handling units

Orion-PTV LØV-R with Sirius

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

Orion-LØV LØV-R with Sirius

Ceiling air diffuser INDULTHERM INDULTHERM-e

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

CHILLED BEAM CASSETTE IQ STAR LYRA

Product catalogue. Air Distribution Systems Cooling and Heating Systems Filter Systems and Dampers. Krantz A trademark of Caverion

Orion-Opus LØV-R with Sirius

Fresh air supply systems

WOLF VENTILATION SYSTEM PRICE LIST

Company History Locations Product range References

Ceiling air diffuser INDULTHERM INDULTHERM-e

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers

Technical Catalog laboratory furniture system

Air Shower with Integrated Air Handling Unit

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level

Domestic & Commercial Fans

Orion-LØV LØV-R with Sirius

Technical Catalog laboratory furniture system

Aluminium Curtain Tracks

FILTERCUBE 2N We set air in motion

FAN IMPELLERS & FAN CASINGS

LØV-R. Svalbard-H. Chilled beam for corner installation between wall and ceiling

Passive chilled beams

Mist eliminators for Flue Gas Desulphurization

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

4 Storage cabinets SCALA

Modular Room System For Operating Theathres

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

Double Skin Air Handling Units

KCJ - Closed kitchen ceiling with Capture Jet system KCJ. Closed kitchen ceiling with Capture Jet system

Whole Home Heat Recovery Ventilation

DATA & FACTS Clean Rooms CGx Air Outlet for Ceiling Installation. For Clean Air and Maximum Protection

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS

CONTENT: VEX308 Decentralised ventilation VEX308

Compact VERTICAL FLAT. Compact. Condensers GCHC/GCVC for HFCs, NH 3

Desiccant Dehumidifier MDC

Type VDW WITH LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH INDIVIDUALLY MANUALLY ADJUSTABLE AIR CONTROL BLADES

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

M Series Fan Filter Units

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Air distribution systems. Sidewall air outlets Turbulent mixing air flow

TopMaster Air Handling unit. Technical data

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

VARICOOL Velum. System description/applications 4 Design and application 5 Planning and dimensioning 7 Technical features 8

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

Filters & Centrifugal Separators

DIF-OT Ceiling Filter. The optimized laminar airflow

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

TURBO HOODS. Product Brochure

EQGA AND EQGB HYGIENIC VERSION, CODE SUFFIX I = 3 AND 4

ROOFTM. roof products. Roof products for a complete ventilation system HOME VENTILATION

General Purpose Laminar Flow Cabinets, Horizontal and Vertical. Horizontal Flow Vertical Flow

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Transcription:

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. with pull-down outlet element DS 4178 E 01.201

Preliminary remarks Materials and designs As a rule, turbulent mixing ventilation is used in cleanrooms to comply with air cleanliness levels of classes 6 to 8 to EN ISO 14644-1 and grade C and D to EU GMP. With this type of ventilation, the clean supply air is mixed with the room air by induction as intensively as possible in order to dilute the pollutants emitted in the room. The more uniform the dilution process, the higher the air cleanliness level. Cleanrooms basically require air outlets whose induction effect brings about a good mixing of the supply air with the room air. Connection housing made of galvanized sheet metal. Filter housing and sealing frame made of galvanized sheet metal, coated on both sides with disinfectant-proof epoxy polyester resin, coloured to RAL 9010 (pure white) or as required. HEPA filter cell class H1 or H14 (EN 1822-1), filter cell frame made of aluminium. Based on a modular design, KRANTZ KOMPONENTEN uses the tried and tested s for supply air and exhaust air. This means, a standard filter housing for the volume flow rate range from 69 to 26 l/s [250 to 850 m³/h] is used. The filter housing can be combined with different air outlets and inlets that are designed as pull-down elements. Having a volume flow rate of 222 to 89 l/s [800 to 1 400 m³/h], a separate filter housing is available upon request. Application Fields of application for the s are all branches of industry, research and medicine as well as hospital areas where air cleanliness is demanded according to the above-mentioned levels. Contact pressure fixture made of galvanized sheet metal. Air distribution element made of galvanized sheet metal, powdercoated to RAL 9005 (jet black, matt); finish with disinfectant-proof epoxy polyester resin. Air outlets made of galvanized sheet metal; coated with disinfectant-proof epoxy polyester resin, coloured to RAL 9010 (pure white) or another RAL colour to be stated by the client. Connection housing with lateral round connection spigot Construction design and function Essentially the consists of the connection housing, the filter housing, the built-in HEPA filter and the pulldown outlet element. The pull-down air outlet element is available in three designs. Filter housing Puri-Drall PDK for supply air The air outlet Puri-Drall consists of a twist outlet with twelve vanes in stellate arrangement. The vane underside is flush with the surrounding air outlet face. As a result, a radial horizontal dispersion of supply air is achieved. Puri-Clean PCK for supply air As a standard the Puri-Clean air outlet has round perforation and a diagonal pitch. The perforated faceplate causes the supply air to flow out horizontally in a radial and uniform pattern. This supply air flow forms an air cushion below the perforated faceplate which prevents the induced room air from touching the face of the air outlet. Thus, the accumulation of dirty air laden with released particles on the ceiling is made nearly impossible. Puri-Clean Puri-Drall Puri-Inlet Design of the modular, shown with the three variants of the pull-down element www.krantz.de DS 4178 E Bl. 2 01.201 Puri-Inlet PEK for exhaust air The air inlet element consists of a perforated faceplate and is optimized for the use as exhaust air inlet. 2

Puri-Drall with lateral round connection spigot Puri-Drall with lateral rectangular connection spigot Puri-Clean or Puri-Inlet with lateral round connection spigot Puri-Clean or Puri-Inlet with lateral rectangular connection spigot www.krantz.de DS 4178 E Bl. 01.201 Air flow pattern of the PDK and PCK Connection housing with round connection spigot on top

Puri-Drall PDK with dry seal and test groove Puri-Clean PCK with fluid seal M 8 8 1a 1a H 9 ød øg 5a 5 I ) 1 2 5b II ) 1 2 H C 4 6 7 4 7 ødn A B ø9 8 9 Puri-Clean PCK ød a H 1 18 128 with lateral round connection spigot A B Key: Puri-Inlet PEK 1 Filter housing 1a Connection housing 5 Sealing frame 5a Test groove 2 HEPA filter cell 5b Immersion edge 2a Dry seal 6 Leakage test point 2b Fluid seal 7 Pressure gauge point A Air outlet a Air distribution element 4 Contact pressure fixture 8 Connection spigot (either lateral or top) 9 L-fastener for ceiling B (releasable) suspension Type Volume flow rate range HEPA filter cell Twist outlet Air discharge element a Dimensions Weight V A max V A min V nenn L W H DN DN oa ob H H 1 ø D C M G l/s m /h l/s m /h l/s m /h mm mm mm mm mm mm mm mm kg PDK 250 PCK V1 2) 125 450 69 250 111 400 545 545 66 200 PEK PDK 15 PCK V2 2) 201 600 8 00 19 500 545 545 66 250 PEK PDK 15 570 62 91 42 249 80 540 21 PCK V 2) 194 700 8 00 167 600 545 545 90 250 PDK PDK 400 PCK V4 2) 26 850 89 20 194 700 545 545 90 280 PEK PCK 1) V5 89 1 400 222 800 1 200 1 170 545 90 450 224 1 195 570 1 250 62 91 42 249 80 500 40 1) Air outlet, special size, rectangular design only with perforated metal sheet and air distribution element, air connection round or rectangular www.krantz.de DS 4178 E Bl. 4 01.201 2) Design with dry seal without test groove, immediately available (in stock) ) Details see page 5 4

Details to page 4 Detail I Sealing frame with dry seal (O) 5 Detail I Sealing frame with dry seal and test groove (T) 5a Detail II Sealing frame with fluid seal (F) 5b 2b 2a 2a 2 2 2 www.krantz.de DS 4178 E Bl. 5 01.201 Installation options for various ceiling systems Clamping profile ceiling T-profile ceiling 1 1 Gypsum board ceiling 1 Seal 8 8 Clamping profile T-profile Ceiling tile Ceiling tile Gypsum board panel Available designs Volume flow rate range V1 2) V2 2) V 2) V4 2) l/s 69 125 8 166 8 194 89 26 m /h 250 450 00 600 00 700 20 Connection box Round connection, lateral Rectangular connection, lateral Round connection, on top Filter housing Dry seal without test groove 2) Dry seal with test groove Fluid seal Air outlet (PDK) DN 250 DN 15 DN 400 Air outlet (PCK) with air distribution element DN 200 DN 250 DN 280 Air outlet (PEK) Shut-off damper 1) electrical adjustment manual adjustment Volume flow rate range V5 222 89 l/s 800 1 400 m /h Filter housing (rectangular) 1) Upon request 2) Design with dry seal without test groove, immediately available (in stock) 850 Seal 5

Sound power level and pressure drop including HEPA filter cell H14 Puri-Drall PDK Features Suited for cleanliness levels 6 to 8 to EN ISO 14644-1, and C and D to EU GMP Total pressure drop p t in Pa 260 200 100 90 80 70 60 p t PDK-V1 PDK-V1 PDK-V2 PDK-V PDK-V2 PDK-V L WA PDK-V4 PDK-V4 50 45 40 5 0 25 20 Sound power level L WA in db(a) ref. 10-12 W The pull-down design of the air outlet elements enables to save time on filter scan tests No additional sealing of the air outlets after the fitting or the replacement of the filter Modular design one standard housing for the volume flow rate ranges 69 to 26 l/s [250 to 850 m /h] (V1 to V4) Designs for with dry sealing (with or without test groove) or fluid sealing Unobtrusive integration into the suspended ceiling thanks to square faceplate with round perforations Stable radial air discharge flow with strong induction of supply air and room air with the PDK and the PCK 15 70 80 90 100 150 200 20 l/s 250 00 400 500 600 700 800 850m /h Air outlet volume flow rate V A No or extremely low dirt accumulation on the ceiling thanks to the formation of a supply air cushion below the air outlet with the PCK Connection for differential pressure measurement; optional connections for leakage test and test aerosol Puri-Clean PCK Short recovery times achieved in recovery test to EN ISO 14644- Total pressure drop p t in Pa 260 200 100 90 80 70 60 p t PCK-V1 PCK-V1 PCK-V2 PCK-V PCK-V4 PCK-V PCK-V2 L WA PCK-V4 15 70 80 90 100 150 200 20 l/s 45 40 5 0 25 20 Sound power level L WA in db(a) ref. 10-12 W www.krantz.de DS 4178 E Bl. 6 01.201 250 00 400 500 600 700 800 850m /h Air outlet volume flow rate V A 6

Type code P K V Air outlet Volume flow rate range Connection spigot Sealing frame Filter cell Surface finish Air outlet PDK = Puri-Drall with pull-down element (supply air) PCK = Puri-Clean with pull-down element (supply air) PEK = Puri-Inlet with pull-down element (exhaust air) Volume flow rate range 1) V1 = 69 125 l/s [250 450 m /h] V2 = 8 166 l/s [00 600 m /h] V = 8 197 l/s [00 700 m /h] V4 = 89 26 l/s [20 850 m /h] V5 = 222 89 l/s [800 1 400 m /h] Connection spigot ES = rectangular, lateral RS = round, lateral RO = round, on top Sealing frame O = for dry seal, without test groove T = for dry seal, with test groove F = for fluid seal Filter cell O = no filter cell H1 = filter class H1 to EN 1822-1 H14 = filter class H14 to EN 1822-1 Surface finish 9010 = face painted to RAL 9010, semi-matt. = face painted to RAL. www.krantz.de DS 4178 E Bl. 7 01.201 Tender text... units Puri-Drall, for cleanrooms with pull-down twist outlet element to generate turbulent mixing ventilation, with strong induction of supply air and room air, no sealing of the air outlet after mounting or replacement of the filter Puri-Clean, for cleanrooms with pulldown outlet element in perforated design, with integrated air distribution element to generate turbulent mixing ventilation, with good induction of supply air and room air and formation of an even supply air cushion below the faceplate, accumulation of dirt is avoided, no sealing of the air outlet after mounting or replacement of the filter Puri-Inlet, for filtering exhaust air from cleanrooms directly at the extract point, with pull-down perforated air outlet element for air inlet, no sealing of the air outlet after fitting or replacement of the filter Suited for cleanliness levels 6 to 8 to EN ISO 14644-1, and grade C and D to EU GMP. consisting of separately packed: connection housing, airtight filter housing with contact pressure fixture for the filter cell, for filter change from below, sealing frame with either dry seal (with or without test groove) or fluid seal with connection for differential pressure measurement and particle sampling on the unfiltered air side, HEPA filter cell, air outlet (PDK, PCK or PEK). Material: connection housing made of galvanized sheet metal without coating filter housing, sealing frame and air outlet made of galvanized sheet metal, powder-coated to RAL 9010 (pure white); finish made with epoxy polyester resin, disinfectant-proof HEPA filter cell class H1 or H14 with filter cell frame made of aluminium contact pressure fixture made of galvanized sheet metal air distribution element made of galvanized sheet metal, powder-coated to RAL 9005 (jet black, matt), finish made of epoxy polyester resin, disinfectant-proof air outlet elements made of galvanized sheet metal, coating with disinfectant-proof epoxy polyester resin, colour to RAL 9010 (pure white) or another RAL colour to be stated by the client Make: Type: Subject to technical alteration. KRANTZ P K V 1) Design with V1 to V4 with dry seal without test grove, immediately available (in stock) 7

Krantz GmbH Uersfeld 24, 52072 Aachen, Germany Phone: +49 241 44-1 Fax: +49 241 44-500 info.filter@krantz.de www.krantz.de