Operating Instructions UniTech Perfect

Similar documents
SUBMERSIBLE DIRTY WATER PUMP

Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0)

INSTALLATION AND INSTRUCTION MANUAL IMPORTANT PLEASE READ:

Operation Manual. Trash Water Pump ARTICLE Image similar

OPERATION & MAINTENANCE INSTRUCTIONS

INSTALLATION AND OPERATING MANUAL. Complete instructions for all models of evouv WARNING:

6000, 8000, & 15000

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

air pump 2700/4500 ? 2YEAR GUARANTEE UK AIRPUMP _33435 CASC /10/ :16 Page 1

ORIGINAL INSTRUCTIONS

Operation Manual. Pond Pump Series HJ and CQP

SUBMERSIBLE WATER PUMPS

WARNING: Ensure that the UV is switched off at the mains before you attempt to conduct any type of maintenance on the EazyPod Complete.

INSTALLATION AND OPERATING MANUAL. Complete instructions for all models of evouv WARNING:

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

EASYCLEAR 3000 YEAR GUARANTEE

INSTALLATION AND OPERATING MANUAL. Complete instructions for all models of evouv WARNING:

ALL IN ONE SERIES HOTLINE 1300 AQUATEC INSTRUCTION MANUAL MODEL 03AS310 03AS311. DATE JULY 2017 v2.0. AQP All in One 1000 Instructions.

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

INSTALLATION AND INSTRUCTION MANUAL

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

FHA 1100 A1 Domestic Water Pump

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

Pond Pump 280 / 420 / 575. Operating instructions Notice d emploi Instrucciones de uso

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

V80-H Multistage Pump Instruction Manual

CoCo LoCo BLOW & GO NUTS DRYER. LSHD24 Instruction Manual

WARNING: Ensure that the unit is switched off at the mains before you attempt to conduct any type of maintenance on the evouv.

NON-SUBMERSIBLE WATER PUMP

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A)

VACUUM EXTRACTOR MODEL NO: CWVE1 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0916

SUBMERSIBLE WATER PUMP. Model Nos. CSE1 - CSE1A - CSE2 - CSE2A CSD3- -CSD3A CSV1A - CSV2 - CSV2A - CSW1A OPERATING & MAINTENANCE INSTRUCTIONS

gamma pond Ultraviolet Sterilizers

BLOW DRY & GO HAIR KIT

INSTALLATION AND INSTRUCTION MANUAL IMPORTANT PLEASE READ:

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

20 LITRE DEHUMIDIFIER

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

HOT WASHER MODEL NO: KING150

Moisture inside the drum is due to final testing.

submersible water pumps

Waste water ejection unit

MiniSkim. Inspiring Excellence in Fish Keeping! Instruction version: 17/08/2012.

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

Complete Cleaning System

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

POWER WASHER MODEL NO: JET 9000 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING: Do not use the machine without reading this manual PART NO:

2 KW OIL FILLED RADIATOR

OPERATION AND MONTAGE MANUAL ROOF FANS

14 Bottle Wine Chiller with Digital Display CZ51186

STRIP CUT PAPER SHREDDER

PJ130S High Pressure Cleaner

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

Paper Shredder. Installation & User Instructions Please keep for future reference 913/0153

Translation of the assembly instructions with operating instructions and technical appendix

PTC Ceramic Heater. Instruction Manual THE SCIENCE BEHIND HEAT

Cross Cut Shredder UAV 380 A1

Whole Room Dryer WRD, WRD/110

ProAction. Paper Shredder. Installation & User Instructions Please keep for future reference 903/1537

User Guide. Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE FOR PUMP MODELS # # # # # # # # #728333

High Pressure Washer 130

TTV 4500 / TTV 4500 HP / TTV 7000

Compact Pressure Washer 100

DUST EXTRACTOR MODEL No: CDE1000

2.8KW ELECTRIC FAN HEATER

DIRTY WATER SUBMERSIBLE PUMP

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

EH W Pressure Washer

OPERATION AND MONTAGE MANUAL ROOF FANS

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

PV3000S Professional Pond Vacuum

3KW ELECTRIC FAN HEATER

A4 Laminator. Installation & User Instructions Please keep for future reference 908/6197

Academy The Straightener IM.indd 1 24/06/ :10. Instruction Manual LSHS16

Pond Oxygenator. Single / Twin / Four.

Manual. Above-counter dispenser for hot drinks OTHG /12

Convection Panel Heater

Tempest TP420/180 Electric Pressure Washer

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

PORTABLE AIR CONDITIONER MODEL NO: AC9000

1300W Pressure Washer RACHP133A

WET & DRY VACUUM CLEANERS

FW422. Integrated In Column Larder Fridge. Installation, use and maintenance.

ULTRASONIC HUMIDIFIER

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data

24 & 30 INCH DRUM FANS

INSTRUCTIONS AND WARRANTY

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

USER GUIDE ENGLISH TOPSTART Ref. TSWZ, TSWRS or TSG Between 0.5 and 3 kw

Combivac Operating Instructions Combivac

DIRTY WATER SUBMERSIBLE PUMP KIT

Installation manual plugs and connectors QUICK-CONNECT (63 A)

150MM ELECTRIC EARTH BORER

Double Door - Dual Zone Wine Cooler

2 IN 1 SUBMERSIBLE PUMP

Moisture inside the drum is due to final testing.

DEVIL CERAMIC SPACE HEATERS

Transcription:

Operating Instructions UniTech Perfect Technische Daten Rated Voltage Power Consumption Max. flow rate Max. head height Cable Protection Dimensions Weight Perfect 5000 49W 5100 l/h 1,85m Perfect 7000 78W 7200 l/h 2,50m Unique Koi e.k. Rauhe Straße 36 46459 Rees Germany Distributed in the UK by: EVOLUTION AQUA LTD. KELLET CLOSE, WIGAN, LANCASHIRE, UK, WN5 0LP TEL: +44 (0) 1942 216 554 FAX: +44 (0) 1942 216 562 info@evolutionaqua.com www.evolutionaqua.com Perfect 10000 105W 10100 l/h 3,50m Perfect 13000 158W 12950 l/h 3,60m 105x265x125mm 4,2kg Perfect 16000 230V/Hz 200W 15900 l/h 4,50m 105x265x125mm 4,2kg

Used symbols at the type label explanation Dust tight and submersible Submersible to 3m depth Must be removed at the first sign of frost Do not dispose of together with household waste! Attention! Read the operating instructions.

UK Operating instructions General Information Thank you for deciding on a German quality product. Please read the instructions for use carefully and make yourself familiar with the pump before initial installation. Be sure to read the safety information to ensure safe and correct use of your pump. Any work on this pump must only be carried out in accordance with these instructions. The high-performance Perfect Pump is designed exclusively for conveying pond water for garden pond filters, water falls and water course systems with the water temperature between +4 C and +35 C. The pump must never be used with any fluid other than water. The Perfect Pump is designed to transport contaminants of up to 8 mm. It is fitted with an thermo control device that ensures that the pump shuts down automatically in case of overheating. The pump switches on automatically when power is connected (risk of accident). Please see the type plate for pump performance data. Inappropriate use and operation will void the liability of the manufacturer as soon as operating permit. Scope of delivery Perfect 5000 / 7000 and 10000 pump models The 5000 / 7000 and 10000 pump models are supplied with 1 hose connection with an inside thread. The provided hose connection is reduced in stages and can accommodate hoses with a diameter of 32-40 mm. At the same time, an Allen key is provided that allows the pump housing to be opened if necessary. 13000 and 16000 pump models The Perfect 13000 and 16000 pump models are supplied with 2 hose connections with an inside thread. Both hose connections are reduced in stages and can accommodate hoses with a diameter of 32-40 mm. A multi-function connection fitting and an allen key for opening the pump housing is provided. CE Manufacturer s Declaration We declare conformity as defined by the EU Directive EMU (89/336/EEC) and the Low Voltage Directive (2006/95/EU, 73/23/EEC). The following harmonised standards were applied: EN 60335-1, EN 60335-2-41, EN 55014-2, EN 61000-3-2, EN 61000-3-3 Safety instruction The manufacturer constructed this pump in accordance with the best available technology to the current safety regulations. In spite of this, hazards for humans and objects can emanate from this appliance if it is not used properly or as intended or if the safety information is not observed. For safety reasons Children, juveniles under the age of 16 and persons who are not able to recognise possible hazards or who are not familiar with the instructions for use must not use this appliance. All work using this appliance must only be carried out in accordance with these instructions. Contact between water and electricity can lead to a life-threatening hazard in the case of improper handling or connections that are not in accordance with regulations. Only operate the appliance if there is nobody in the water. Always remove all mains plugs on all appliances in the water before putting your hand into the water. Compare the electrical data of the power supply with the type plate on the appliance. Please ensure that the appliance is protected by a RCD with a maximum measured residual current of 30 ma (EN 61008-1). Only operate the appliance from sockets that have been installed according to regulations and only use earthed fittings that are approved for outside use. Never carry or pull the appliance by the connecting cable (power cable). The connecting cable cannot be replaced as it is firmly encapsulated in the motor housing. The appliance must not be operated if the connections are faulty. Please dispose of the pump if the cable is damaged. In the case of garden ponds the electric fittings must comply with the international and national installation regulations. Only use original spare parts and accessories. Never make technical alterations to the appliance. Never operate the pump without water. Electrical connection Only connect the pump to a 230 V alternating current. The socket must be fitted in accordance with national regulations. The mains plug and all electrical connecting parts must be dry. To protect the pump against excessive voltages, a 30 ma residual current circuit breaker must be fitted between the pump and the socket (according to EN 61008-1). It is only permissible to use the pump in a garden pond and its safe area if the socket has been installed according to DIN VDE 0100, part 702. If there are any doubts in respect of the connection to the power supply, please consult a qualified local electrician. Protect the pump cable from damage especially if there is the possibility of direct contact with gardening appliances such as lawn mowers or with children and pets. If an extension lead is required to connect the pump, please ensure that this has a protective ground contact and is approved for outside use. The same applies to fittings, cables or other connecting lines. All electric fittings on ponds must comply with the national and international installation regulations. A warranty claims are excluded following improper repair or opening of the pump by third parties. Likewise, liability will not be accepted for consequential damages. Only ever carry out work on the appliance when the power is off. Overload protection The pump is fitted with an automatic thermal overload protection. This switches off the pump if it overheats. If this occurs, switch off the power at the mains supply to the pump. Check for the cause. Usually it will be debris blocking the inlet of the pump or obstructing the impeller or limescale build up. Remove the cause and wait for the pump to cool down. Then switch on the pump again.

Installation PLEASE NOTE The appliance must not suck in air or be operated without water flow. DANGER OF DESTRUCTION In order to avoid flow losses, only choose hoses with a large diameter and the hose length as short as possible. We recommend an inlet hose with a diameter of 40 mm. Cut the stepped hose tale at the notch intended especially for this. Place the pump on a firm subsurface in a horizontal and safe position. Uninstall the pump in case of frost. The pump must be at least 25cm under the water so that it does not suck in air. Initial operation PLEASE NOTE Hazardous electric voltage. Possible consequences: death or serious injuries (see safety information) Only operate the pump if nobody is in the water. Always remove the mains plugs on all appliances in the pond before putting your hand into the water The pump switches on automatically when power is connected. Remove the mains plug to shut down the pump. Cleaning / maintenance PLEASE NOTE Hazardous electric voltage. Possible consequences: death or serious injuries (see safety information) Always remove the mains plug before cleaning or carrying out maintenance work on the pump. Always remove the mains plugs on all appliances in the pond before putting your hand into the water. The maintenance intervals depend on the degree of pond water contamination and/or water hardness. At the beginning check the function and contamination of the pump/rotor/rotor compartment every day. Later on, choose the time intervals accordingly. We recommend maintenance and cleaning on a regular basis in order to ensure long-term flawless operation and to extend the service life of your pump. Dismantle the pump according to the disassembly drawings. Clean all parts under running water using a soft, lint-free cloth (e.g. leather). Check all parts for damage and replace them if necessary. In the event that the rotor or the rotor compartment is affected by calcium or limescale deposits, use diluted acetic acid to dissolve the limescale. The time involved depends on the degree of calcination. To clean further, remove the rotor (Disassembly / Assembly) and clean the entire unit completely using fresh water and a soft, lint-free cloth (e.g. leather). The pump can be re-assembled in the reverse order once cleaning has been completed. Disassembly / Assembly 1. Please observe the safety information. Disconnect pump from the mains. 2. Take the pump out of the water and open the housing by loosening the four stainless steel screws on the base of the housing using the Allen key included in the scope of delivery 3. Remove the pump and clean the housing 4. Use the Allen key supplied with the delivery to loosen the 4 stainless steel screws on the front of the pump cover. Lift off the pump cover and remove the rotor. 5. The pump can be re-assembled in reverse order after cleaning/maintenance has been completed. PLEASE NOTE: Always remove the mains plug before cleaning or carrying out maintenance work on the pump. Always remove the mains plugs on all appliances in the pond before putting your hand into the water. Troubleshooting: Is the pump getting enough water? Is the pond filter blocked? Are hoses or nozzles blocked? Has the pump rotor seized up (cleaning according to instructions)? Has the pump cooled down? Once you have remedied the problems, the pump can be put back into operation again. Breakdowns Cause Remedy Pump not running No power supply Residual current circuit breaker triggered Pump rotor assembly jammed The thermal overload has tripped Check power supply Check fuse box, RCD and wiring Remedy blockage or clean pump. See Instructions Pump not conveying at all or only small quantity Pump not deep enough under water Inlet blocked Air in the system Hose buckled Excessive flow resistance Check pump water-level Check feed line, clean Check feed line Check hose Reduce/check hose length and use larger diameter hose Storing in winter As this pump range is fitted with a high-quality ceramic shaft, it has to be uninstalled in case of frost. Clean the pump thoroughly and store it in a frostfree place (at room temperature) in a container filled with water. Disposal Please dispose of the pump in accordance with the national regulations. Please consult your specialist dealer in this respect. Warranty As long as the Perfect Pump has been used properly as a pond pump, fitted and handled correctly and, as we see it, has not been vandalised, we provide a 5 year warranty as from purchase of the pump. Please keep the sales receipt, as this is proof for the warranty. At the same time, the attached warranty card should be completed by the dealer following purchase of the pump. Please keep this together with the sales receipt. Damages due to faulty storage or installation and damages due to limescale are excluded from liability. Liability claims are restricted exclusively to the repair or replacement of a faulty pump. The warranty cannot be transferred to third parties. Statutory customer protection rights are not affected by this.

Warranty section (please complete and keep with the sales receipt) Date of purchase Serial number Name/adress of specialized trade: (stamp) pumpmodell: UniTech Perfect 5000 / 7000 / 10000 / 13000 / 16000 (pleas tick appropriate model) Distributed in the UK by: EVOLUTION AQUA LTD. KELLET CLOSE, WIGAN, LANCASHIRE, UK, WN5 0LP TEL: +44 (0) 1942 216 554 FAX: +44 (0) 1942 216 562 info@evolutionaqua.com www.evolutionaqua.com