High performance dry leak detectors ASM 182 TD+ ASM 192 T2D+ HELIUM LEAK DETECTORS 297 > 308

Similar documents
ASM 340. Best in class leak detector for high reliability testing in various applications, using helium and hydrogen

PHOENIXL 300 New Standards in Leak Testing. Technical information

PHOENIX L300i New Standards in Helium Leak Testing The next Generation

AGILENT VS SERIES LEAK DETECTORS

ELD500 PRECISION LEAK DETECTOR

Helium Leak Detection Systems

Vacuum for Research & Development

Sensistor ISH2000 Hydrogen Leak Detector

shop online:

Remote. control unit. accessories. Leak detector SmartTest. Remote control unit for SmartTest. Remote. Vacuum analysis and measurement

NONWOVEN INDUSTRIES. Advanced Web Gauging Solutions. The Measure of Quality

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

Product Overview 2017 Innovative Vacuum Components and Systems for Versatile Applications

Atlas Copco. Heat-of-compression rotary drum dryers ND series ( l/s, cfm)

Custom Products Gallery

Helium Leak Detector The clever and modular Solution. Simple Operation. Top Performance.

E²M. Innovation with Integrity. Enhanced Environmental Mass Spectrometer. Safety & Security

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Automating functions. Simplifying operations. Modernizing protection. Bebco EPS 5500 Automation for Purge and Pressurization

The right temperature worldwide NEW. LAUDA Integral XT. Professional thermostating for pilot plant and mini-plant purposes. Product information

T.ex Single Gas Detector VISA

HydroFlex 3-in-1 microplate strip washing. Flexible and reliable microplate strip washing and vacuum filtration in a compact, modular platform

2008 JINST 3 S The CMS experiment at the CERN LHC THE CERN LARGE HADRON COLLIDER: ACCELERATOR AND EXPERIMENTS.

HFID Heated Total Hydrocarbon Analyzer Module

TIMS TIMS. Thermal Ionisation Mass Spectrometry.

MEMS Accelerometer ICs. AMR Magnetic Sensor ICs. Gas Flow Modules. Differential Pressure Sensors. Tilt Modules. Current Sensors

Mechanical Vacuum Systems for Secondary Metallurgy Steel Degassing

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

Market Survey. Technical Description Supply of Helium Leak Detectors

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

CLEAN-LASERSYSTEME GMBH

Advance Optima Module Magnos 17

Thermo Scientific Heratherm Heating and Drying Ovens. efficient safe easy. Part of Thermo Fisher Scientific

Leak testing in the HVACR Industry

M700-Series Multifunction OTDR

thermal management features such as temperature setpoint control, temperature ramp rate control, and process heating.

Guide Specifications

Chemistry diaphragm pumps

ASM 380 Mobile high performance helium leak detector. Operating instructions. Translated from original version

HydroFlex FLEXIBLE AND RELIABLE MICROPLATE STRIP WASHING AND VACUUM FILTRATION IN A COMPACT, MODULAR PLATFORM. 21 CFR Part 11* 98/79/EC IVD-D*

vacuum FLOW support excellence experience

Lumidor portable gas detection. Portable protection from hazardous gas

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

Thermo Scientific Heratherm Heating and Drying Ovens. Efficient, safe and easy

MEDICAL CHILLER SYSTEMS

CALIDUS tm the Modular micro Gas Chromatograph

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

MODEL 1925-PR TRITIUM HEAVY WATER LEAK DETECTOR

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. ASME/ANSI B73.1 Chemical Process Pump

RAMAN SPECTROSCOPY See more, faster than ever before

Customers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation

C A T A L O G

gray Laser Power Detectors For fast and accurate measurements

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-75 VSD+ (7-75 kw/ hp)

Automating functions. Simplifying operations. Modernizing protection. Bebco EPS 5500 Automation for Purge and Pressurization

Variable Temperature Microprobe Systems

Air-cooled Screw Chillers Model RTAF G Process

Screw Compressors. S Series. Capacities from: 8.8 to 89 cfm Pressures from: 80 to 217 psig.

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Access Energy Thermapower Organic Rankine Cycle (ORC) Systems

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp)

palmotdr Series Handheld OTDR

TD Series Temperature Transmitter with Local Display. One-piece sanitary construction 2-wire electronics High accuracy

incubator, the best in its class

Product Overview 2015 Innovative Vacuum Components and Systems for Versatile Applications

LOW MINIMUM DETECTABLE ACTIVITY (MDA)

Screw Compressors SM SERIES. Capacities from: 16 to 54 cfm Pressures from: 80 to 217 psig

Technical specifications of FT-IR Spectrometer

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Improving Productivity, Quality and Security

UNIVEX Experimental systems for thin film coating and Space simulation

NEXTorr Pumps. making innovation happen,together

Spectrum Detector, Inc.

Rotary Screw Compressors R-Series 4-11 kw (5-15 hp) Fixed and Variable Speed Drives

HYDRONIC SOLUTIONS. More than just hydronic boilers, we offer the most efficient integrated hydronic solutions on the market.

palmotdr Series Handheld OTDR

Open the Door to Increased Productivity and Cost Efficiency

Leak Detection C A T A L O G

OTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling

SMD601 Plus. The most Sensitive Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities. Threat Detection through Electromagnetics

laboratory & sterilization technology

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Diode-Pumped Solid-State Blue Lasers

Komline-Sanderson Paddle Dryer. Drying technology for biosolids, sludges and by-products

ThermoControl 0 C - 10 C - 20 C - 30 C

VARIABLE SPEED DIRECT DRIVE CENTRIFUGAL AIR BLOWERS

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

halt & hass systems

Airflow Sensors Line Guide

SHAKING WATER BATHS ENGLISH

Ulster Bank Business Achievers Award Emerging Technology

Thermo Scientific Heratherm Heating and Drying Ovens. efficient

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

CPO N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. ASME/ANSI B73.1 Chemical Process Pump. Springer Pumps, LLC

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

Power Flame Incorporated

Transcription:

H E L I U M L E A K D E T E C T O R S High performance dry leak detectors ASM 182 TD+ 297 > 308

The most powerful dry leak detectors on the market to meet demanding clean applications needs : a unique Helium leak detection concept delivering high performance and unmatched cleanliness, offered in a compact or console format. New Alcatel was the first to introduce a standard oil-free helium leak detector on the market, the ASM 180 TD. The success was immediate in the semiconductor industry. Its performance was very appreciated (high roughing capacity, high sensitivity, low cost of ownership ). Alcatel anticipated the need for new leak test requirements for larger s in the semiconductor market for the OEMs as well as the End Users. Once more, Alcatel has designed the most powerful and sensitive dry leak detectors on the market today: the. PERFORMANCE RELIABILITY High helium leak detection sensitivity: 5.10-12 Atm.cc/s Fast response time thanks to the very large helium pumping speed (up to 20 l/s) High roughing capacity (up to 30 CFM) Fast recovery time. Repeatability of the test Ease of maintenance Rugged design THE ASM 182 TD+ AND THE SOLUTIONS FOR ALL YOUR NEEDS FLEXIBILITY Customized solutions: - Compact model: ASM 182 TD+ for limited footprint requirements. - Console model: for large- leak test requirements. CLEANLINESS 100 % hydrocarbon free The cleanest leak detectors on the market Clean-room compatible. 298

An innovative concept offering the Best Solution to a wide range of applications The 100 % hydrocarbon-free Alcatel dry leak detectors guarantee total cleanliness during the leak test of systems and components. The introduction of the ASM 182 TD+ and demonstrate once more our commitment to performance in demanding industries such as: Semiconductor, Medical, Pharmaceutical, Electronics, Instrumentation and food packaging. Our dry leak detectors are versatile and accommodate different leak test methods: - the hard vacuum (inboard testing for high sensitivity requirements) - sniffing (outboard leak testing). Semiconductor Process s, load locks, vacuum system maintenance, gas panel and lines, mass flow controllers... Medical and pharmaceutical Catheters, blood filters, pacemakers, hermetically sealed packaging, blister packs... Nuclear physics / research & development Particle accelerator vacuum and beam lines, cryogenic lines vessels, vacuum valves and components, vacuum systems and instruments, accelerators and containers... Instrumentation RGA, gas analyzers, lasers, instrumentation analyzers, electronic microscopes Electronics hermetically sealed integrated circuits, liquid crystal displays, quartz displays, hybrid circuits, open-packages, optoelectronic components, fiber optics. Packaging industry Hermetic medical and pharmaceutical packaging, food containers, food and beverage cans, drums... 299

Compact model: ASM 182 TD+ Compact version for leak testing applications where space is limited. Recognized and proven technology Compactness has always been synonymous with limited performance and poor layout of components. Alcatel has challenged this belief. Using its unique frictionless multi-stage dry pump model ACP 20, Alcatel designed an unmatched concept delivering high performance in a well laid-out system. A compact dry frictionless Roots type pump for optimized performance Given the small size of the dry pump, the leak detector can be operated in confined environment. Transportability (option) The ASM 182 TD+ is a self-contained unit which can be installed on a cart for easier manœuverability. ASM 182 TD+ The most powerful console dry leak detector: Console version with extended pumping speed capability or leak testing large s. Dry leak detector, with a booster turbomolecular pump of 100 l/s. 50 m 3 /h (30 CFM) roughing capacity (option): Unmatched oil-free dual roughing pumps operating in parallel at high pressure for contamination free leak detection of volumes up to 1,000 liters without auxiliary pump required. Note These dry leak detectors are equipped with oil-free pumps for ultra-clean applications. 300

Unmatched performance High sensitivity The integration of Alcatel s innovative magnetic deflection 180 degree analyzer and unparalleled amplification system with a direct flow test mode delivers the highest sensitivity (5.10-12 Atm.cc/s helium minimum detectable leak). The Alcatel design analyzer cell is recognized for its smart design offering unmatched stability, high sensitivity, and easy maintenance. The unique Alcatel analyzer cell concept with dual filaments (single replacement) enhances the up-time of the analyzer cell. Fast roughing capacity The well-proven ACP 20 multistage dry Roots frictionless pump technology guarantees a high level of cleanliness, reliability and longevity. The dry Roots concept delivers and maintains performance from the first day of operation and over the next 5 years (8 hour shifts) without any maintenance required. ACP cutaway: basic pumping principles Rugged design Alcatel s modular design, using robust components, provides exceptional reliability in the most severe industrial applications or environments. Automatic protection integrates all safety controls to enable the instrument to withstand accidental air-inrushes and severe shocks due to transportation or power failures. 301

Control panel and remote control incorporating state of the art electronics Settings and maintenance Signal correction Auto-calibration Auto-calibration with built-in temperature compensated calibrated leak and age compensation. Auto-calibration during the start-up sequence and the ability to activate it periodically. All pertinent information related to the auto-calibration process and its settings. Comprehensive display panel includes: operator interface level, settings, maintenance information (preventive and corrective maintenance). All of which is passwordprotected. Parameters can be quickly and easily modified via a simple menu. The control panel can be customized to provide 4 levels of operator interface to respond to any needs. Automatic correction processed by the detector through an external calibration to compensate for split flow test configuration. Ability to manually adjust the correction factor to display direct readout of the helium signal for split flow configuration. You can t miss a leak thanks to the: dynamic green/red bargraph audio alarm with variable pitch vocal synthesizer 302

Control panel of the ASM 182 TD+ A very comprehensive remote control is offered as an option for the ASM 182 TD+ and available as standard for the. Display The helium signal is displayed in two different ways: bargraph display to highlight the fast evolution of the signal and digital display to get high resolution and a direct readout. Variable pitch audio alarm proportional to the Helium signal amplitude for easy location of leaks, available in any test mode. Auto-zero function The advanced floating auto-zero function allows the operator to conveniently improve the sensitivity of the detector when the helium signal measurement becomes more difficult due to a high background level. The advanced floating auto-zero is based on a specific algorithm which eliminates the display of erroneous results and guarantees the detection of any size leak. All these functions are directly accessible by depressing one single switch. A very helpful function to increase the sensitivity of the test in inboard as well as outboard leak test modes. 303

Options and Accessories Options 3 masses Gas line bullet test Metal seals or elastometer seals Clean room compatible cover Test s Test Long distance sniffer Transport cart Accessories Description Long distance sniffer probe with a 5 meter tube (16 ft) 797925 Transport cart (for the ASM 182 TD+ only) Remote control with a 5 meter cable (offered as a standard for the ) Foot pedal for cycle command (1.5 meters / 5 feet) PART NUMBER 072654 072487 100913 304

Technical Specifications Specifications Features Measurement range Maximum test pressure in large leak mode Maximum test pressure in normal mode Helium pumping speed at inlet port ASM 182 TD+ Roughing capacity ASM 182 TD+ Response time on calibrated leak at inlet port Required performances 5.10-12 to 10-1 mbar.l/s 6 mbar or more 2.10-2 mbar 4.4 l/s 20 l/s 25 m 3 50 m 3 < 0.5 s Sniffing mode Measurement range in sniffing mode Helium signal response time with 5 m long probe 1.10-7 to 1 mbar.l/s < 0.3 s Integrated functions Auto-calibration (with built-in temperature compensated calibrated leak) Auto-zero (with floating zero method to ensure that the signal never goes negative) Automatic signal correction (external calibration or manually adjustable correction factor) Full automation of test cycle including: - cycle sequence - memorization of the last test - test result display Audio management Audio alarm with variable pitch (up to 90 dba) / Vocal synthesizer Dimension Compact ASM 182 TD+ Console Weight Compact ASM 182 TD+ Console Dimensions 600 x 450 x 460 mm (23.6 x 17.7 x 18.1 inches) 600 x 730 x 885 mm (23.6 x 28.7 x 34.8 inches) 96 kg (212 lbs) 185 kg (407 lbs) Customization of the detector Several languages of utilization Wide measurement units 305

Ordering information ASM 182 TD+ D1 0 0 0 Leak Detector ASM 182 TD+ D1 Seals for the vacuum module and analyzer cell Elastomer seals Metal seals R M The leak detector can be provided with : Elastomer seals (for the high vacuum as well as the inlet bloc) as standard (R) or with metal seals for specific applications (M). The elastomer seal is the standard configuration. Detection option Standard With gas line S G Gas line "bullet test" (G). This option allows to leak test long gas lines with very small diameter. Using a ultra clean purge gas such as nitrogen as a carrier gas, the line is maintained in a viscous regime to allow fast response time. Test None Small Model 0 1 Medium Model Large Model 2 3 Painted P Cover UCT C U.C.T. - Ultra Clean Technology (C) Front and rear covers and frame in stainless steel. Compatible with a connecting accessory for the extraction of cooling air through an airtight tube. Language and unit French English German Japan A 110/130 V 50/60 Hz 7 B Voltage C E 200/240 V 50/60 Hz 8 Cable Type USA France/Germany UK Italy Switzerland Without cable type 1 2 3 4 5 7 ASM 182 TD+ D1 Metal seals M For example You need Standard S SM 1 UCT C English B 200/240 V - 50/60 Hz 8 UK 3 = D1 0 M 0 S 1 C B 8 3 0 306

Ordering information D3 0 0 0 0 Leak Detector D3 Seals for the vacuum module and analyzer cell Elastomer seals Metal seals R M The leak detector can be provided with : Elastomer seals (for the high vacuum as well as the inlet bloc) as standard (R) or with metal seals for specific applications (M). The elastomer seal is the standard configuration. Roughing system Standard 50 m 3 /h S T Test None Small Model 0 1 Medium Model Large Model 2 3 Language and unit French English German Japan A 110/130 V 50/60 Hz 7 B Voltage C E 200/240 V 50/60 Hz 8 Cable Type USA France/Germany UK Italy Switzerland Without cable type 1 2 3 4 5 7 D3 Elastomer seals R For example You need Roughing 50 m 3 /h T LM 3 German C 200/240V - 50/60 Hz 8 Germany 2 = D3 0 R 0 T 3 0 C 8 2 0 307