CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

Similar documents
DRAFT INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

6000 AIR SERIES SYSTEM OPERATION MANUAL A-AZ Rev.0 5/07

UNIVERSAL AIR SERIES SYSTEM OPERATION MANUAL

UNIVERSAL TEE STYLE Hydromassage Bath Heater INSTALLATION INSTRUCTIONS

6500/7500 SERIES OWNERS OPERATION GUIDE

OWNERS OPERATION GUIDE

Spa Control System OWNER S MANUAL

ULT L IMAT A E SERIES SOLID-STA T T A E SYSTEM OPERAT A ION MANUAL 8600

Typical Installation Breaker Box Class A 50 amp, 120/240 volt, GFCI

RELAX. REVITALIZE. RESTORE. LUXURY SPA UNIT Installation Manual. English. For Model Numbers 2848, 2853, 3153 and 3255

Destination Collection Whirlpool Bath Installation Instructions

Factory Direct Walk-In Tubs WALK-IN TUB. Installation Manual. For Model Numbers VT2848, VT2853, VT3153 and VT3255

4230/6230/9230 SERIES OWNERS OPERATION GUIDE

4200/6200/9200 SERIES

AWP 3260 CWH Installation Instructions Hydro-massage Bathtub - UL 1795

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

CHAMPION PUMP OWNER S MANUAL

4200/6200/9200 SERIES OWNERS OPERATION GUIDE

DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

4100/6100/7100 SERIES OWNERS OPERATION GUIDE

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

HT-2 / 9600 Series Control Contents

AirBath Hydro-Massage Tubs UL1795 Installation and Operating Instructions

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

NEXT SOLID-STATE SYSTEM. P u m p. * A u x. e f

4230/6230/9230 SERIES OWNERS OPERATION GUIDE

SMF PUMP OWNER S MANUAL

Viking Installation Guide

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL

OPERATION & INSTALLATION MANUAL

Installation Guide. Pedicure Spa D K-163, K-1006, K-1011, K-1012

Pool Power Pak. III with On/Off Switch UL Models (1 HP), (1-1/2 HP) NEC Models (1 HP), (1-1/2 HP)

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.

INSTALLATION, OPERATION AND MAINTENANCE

Next Generation Corona Discharge Installation & Operation Manual

Elite Primer Baldor Series External Pond Pump

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

BACK WASH INSIDE THE SPA

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

COPPER FREESTANDING TUB

Check that connection to main board is clean and sound at J8

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

THE BEAUTY OF WATER THE SCIENCE OF RENEWAL. Heating Circulation System. Installation Instruction Manual

Pump - Owner s Manual

Installation and Operation Manual MG-304. Please read this manual carefully before use.

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

40 Built-in Electric Fireplace Operating and Installation Instructions

K-870-JA-AA K-872-JA-AA

QUIETFLO OWNER S MANUAL

RESIN FREESTANDING TUB

Installation, Operation & Service Procedures

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

REFRIGERATOR SAFETY. Your safety and the safety of others are very important.

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

A2Z Ozone, Inc. PRODUCT MANUAL

INSTALLATION INSTRUCTIONS

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

INSTALLATION & OPERATING INSTRUCTIONS

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location

SYSTEM BASIC WHIRLPOOLS

ULTIMATE SERIES SOLID-STATE

Installation Manual CARBONATOR With Plain-Water Booster

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

Vintage Whirlpool Baths: K-702-AC K-702-H-AC CA (9427) Copyright 1994 Kohler Co.

Viking Installation Guide

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

INSTRUCTION MANUAL (UNIT APPEARANCE MAY VARY FROM IMAGE) BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

SAFETY INSTRUCTIONS & OPERATION MANUAL

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

Clear Comfort Residential Pool & Spa Sanitization System Installation, Operations & Maintenance Manual

MSPA-MP METAPACK SERVICE MANUAL. Visual step-by-step guide to easily identify & correct technical problems! Gecko Electronics Inc.

model VMH300 vornado.com WHOLE ROOM HEATER OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

OZONE SYSTEM FOR IN-GROUND POOLS UP TO 18,000 GALLONS

Installation. Built-in Full Height Wine Cellar VCWB301

ELECTRIC SPA-PAK HEATER INSTALLATION & OPERATING INSTRUCTIONS

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

Installation Guide BUBBLEMASSAGE. English page T01-A

Gen II Entree Bath. Maintenance Manual. All Models. Important Safety Instructions Read & Follow All Instructions Thoroughly

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

AQUA-FLO A SERIES. The Bronze Pump designed exclusively for any swimming pool or spa application.

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

FREEFLOW OWNER'S MANUAL 115/230V System Owner's Record

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

Instructions for Baptistry Immersion System

K 3.97 M. Specifications or visit our website: In USA call: Part No

PERSONAL HEATER OWNER S GUIDE

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Transcription:

AIR SERIES SYSTEM INSTALLATION MANUAL

CONTENTS CONSIDERATIONS General Plumbing Component Connection 2 2 2 ILLUSTRATION Control System 3 CONFIGURATION Voltage Verification 4 CONNECTION Component Connection Receptacle Color Chart 4 5 ELECTRICAL INSTALLATION Circuit & Breaker Ratings Service Connection 120 & 240 Volt Plug Connected Systems 6 6 7 SPECIAL CONSIDERATIONS Spa Light Air Blower System Startup Pressure Switch Adjustment TROUBLESHOOTING 8 8 9 10 11 1

CONSIDERATIONS Hydro-Quip equipment and control systems were designed exclusively for installation into the equipment compartment of a portable spa. The skirting of the portable spa, with suitable equipment compartment doors securely fastened, serves as a barrier to prevent a spa user from coming in direct contact with any part of the system. General! The Control must be installed on a firm, level surface provided by the cabinet of the spa.! The area where the Control is mounted must have adequate drainage to prevent flooding the equipment under all circumstances.! The equipment compartment should have adequate ventilation.! The portable spa should be installed with a minimum of 3 feet (1m) of free, unobstructed space between the opening of the spas equipment compartment and any permanent structure. This will allow for ease of installation and access for regular maintenance. Plumbing! To assure adequate performance, the spa plumbing must be 1 ½ minimum. The use of 2 is recommended. A good grade of fresh PVC-to-PVC primer and solvent should be used for all water plumbing connections.! The pump(s) provided with Equipment Systems are non self-priming. Non self-priming pump(s) must be installed below the normal water level.! To allow for safe operation of the spa, the suction fittings connected to the suction opening an Equipment System should be listed or approved for the purpose. There may be three separate plumbing systems in the spa. Verify the function of each pipe. A) Suction Side Plumbing: this plumbing will connect to the spas skimmer, main drain and suction fittings. This plumbing connects to the open end of the pump on your Equipment System. B) Discharge Side Plumbing: this plumbing will go to the spas hydrotherapy jets and message fittings. This plumbing connects to the open end of the heater on your Equipment System (see illustration on page for details). C) Air Blower Plumbing: this plumbing will go to an air channel under the floor or air distribution manifold of the spa. This plumbing connects ONLY to an air blower. Component Connection! C All components such as the pump(s), air blower and light are connected using colored receptacles located on the right or left side of the control. 2

ILLUSTRATIONS 5 6 1 2 3 DISCHARGE AIR-SWITCH COMPONENT RECEPTACLES SUCTION 4 1) Thermostat 5) Overheat Protection (Press to Reset) 2) Mode Selector Switch 6) Heater ON Indicator 3) Time Clock 7) Pump Assembly ( included with 4) Ground Fault Circuit Interrupted (GFCI) Equipment Systems Only) 3

CONFIGURATION Congratulations on your purchase of the Air Series Control from Hydro-Quip. This series of controls has been developed to allow you complete flexibility during your installation. We highly recommend that all component cords be replaced at the time of installation. Your control has been pre-configured at the factory. Verify input and component all component voltages prior to connecting them. VERIFY YOUR COMPONENT VOLTAGE REQUIREMENTS: 120 VAC will not harm a 240 VAC component if operated temporarily. 240 VAC WILL harm a 120 VAC component almost immediately. Hydro-Quip cannot be held responsible for mis-wire related damage to components. CONNECTION All systems include colored component receptacles for ease of identification. Match the component plug with its mating receptacle using the Receptacle Identification Chart on the following page. 4

CONNECTION Below is a color chart that illustrates the receptacle colors and component connections. Other receptacles that are not shown: Light (12V) - White 3-Pin Amp or White Molded, 120V Power - Green Amp/Molded, Circulation Pump - Red 3-Pin Amp or Blue Molded. Receptacle Color Chart Pump 1 RED RED Pump 2 PINK PINK Blower WHITE PURPLE Ozone YELLOW YELLOW Assure that all plugs and receptacles are fully connected. A loose connection can cause damage to the system. Note: Hydro-Quip utilizes the BLACK wire for High-Speed and the RED wire for Low-Speed in Two-Speed Pump Circuits. Keep this in mind when connecting a Two-Speed pump that has not been purchased with the system. 5

ELECTRICAL INSTALLATION A qualified and licensed electrician in accordance with the National Electric Code (NEC) Article 680, Canadian Electric Code, and with any local codes must accomplish the electrical installation. All connections must be made according to the electrical installation label on the outside of the control box. Follow the instructions from the label if they are different than the instructions in this manual. If your electrician is not absolutely sure how to connect your system correctly, call your local dealer. Any mistake may be costly and invalidate your equipment warranty. The GFCI (Ground Fault Circuit Interrupter) is a mandatory electrical safety device required for all portable spas and hot tubs as specified in the National Electrical Code Article 680-42. The GFCI in your particular installation may be installed at the electrical service panel, a separate sub-panel or built into your Hydro-Quip System. Your spa equipment requires a DEDICATED CIRCUIT. No other appliances or lights can be on this circuit. Refer to equipment data label for power supply requirements of your spa equipment. Use copper conductors ONLY. The ground must be sized following the National Electric Code, Table 250-95. NOTE: Due to the electrical requirements of some models, it may be required to SPLIT the incoming electrical service to accommodate the GFCI Circuit Breaker limits. Contact your electrician if you need additional information on this topic. Circuit & Breaker Rating Maximum Amps Minimum Wire Size 15A 20A 30A 40A 50A 60A 70A 80A 12A 16A 24A 32A 40A 48A 56A 64A 14 12 10 8 6 4 4 4 120 Volt - Your control will connect to a dedicated 15A or 20A receptacle via the cord-end GFCI (Ground Fault Circuit Interrupter) included (see next page for details). 240 Volt - Your control must be permanently connected by a licensed electrician or qualified technician. 6

ELECTRICAL INSTALLATION If your system was configured to include a 120VAC power cord, ensure that the proper receptacle has been installed. DO NOT under any circumstances modify a 20 Amp plug to fit into a 15 Amp receptacle or use an extension cord. Doing so will create hazardous conditions and/or invalidate the warranty. 15 AMP RECEPTACLE DO NOT USE AN EXTENSION CORD 20 AMP RECEPTACLE Refer to the System Data Label for equipment voltage and maximum amperage draws. Install proper size Ground Fault Circuit Interrupter (GFCI) or circuit breaker, then proper sized wiring and bonding wire. For Power conductor size, refer to the National Electric Code Table 310-16. For Ground conductor size, refer to the National Electric Code Table 250-122. A bonding lug has been provided on the control box to allow connection to local ground points. To reduce the risk of electrical shock, a solid copper bonding wire should be connected from this lug to any metal ladders, water pipes or other metal object within 5 feet of the spa. WARNING - BE SURE THAT YOUR POWER SUPPLY CIRCUIT CAN ADEQUATELY HANDLE THE AMPERAGE YOU SELECT. WARNING - DO NOT CHANGE CONFIGURATION PLUG WHILE POWER IS ON. The control wiring has been provided. Following NEC and local codes in effect at the time of installation, connect the Black wire to input Line 1, Blue wire to input Line 2 (if applicable), White wire to Neutral and the Green wire to ground. 7

SPECIAL CONSIDERATIONS Spa Light: Using a suitable 2 ½ diameter hole-saw, cut a hole in the spa wall. Cut from inside the spa wall toward the outside to prevent splintering the inner surface. Remove any insulation material from around the hole (at least ½ ) at the outside spa wall. Install the gasket onto the light body and install the light into the hole. Take care not to over tighten the nut securing the light body. (Silicone sealant may be used in place of the gasket. Allow adequate time for sealant to cure before filling the spa.) Note: It is recommended that the water level be stopped just above the level of the spa light until a thorough inspection for leaks can be completed. Light Bulb Light Body Spa Wall Gasket Air Blower: The air blower MUST be installed to ensure that water CANNOT enter the air blower motor. This can be accomplished by installing a double air loop that incorporates a check valve. CAUTION: The air blower must be connected ONLY to the spa's air distribution plumbing. Connecting the air blower to any air piping associated with the hydrotherapy jets will create a hazard by providing a path for high-pressure water to be forced into the blower motor. This will result in damage to the air blower and create an electrical shock hazard. 8

SPECIAL CONSIDERATIONS System Startup Procedures: 1) Read and familiarize yourself with the System Operation. 2) Unplug the power cord (120-volt system only) or turn the electrical power OFF at the service or breaker panel (120 or 240 volt permanently connected units.) 3) Open all WATER shut-off valves. 4) For spas equipped with a hose bib or drain valve, make sure that it has been closed. 5) For spas equipped with in-line or pressure water filters, make sure that the filter nut, housing drain plug, and air relief valve are closed and tight. 6) Using a standard water hose, fill the spa with fresh tap water to the level recommended by the spa manufacturer. 7) Inspect all plumbing connections and lines for any sign of water leaks. 8) Connect a garden hose to the bib or drain-valve and run it away from the equipment compartment. Open the hose bib or drain valve to bleed off any air that may have been trapped in the plumbing system during the filling operation. After a steady flow of water appears, close the hose bib and remove the garden hose. Be sure to dry off any excess water around the electrical compartment before proceeding to the next step. 9) Close all AIR control valves. WARNING: Do not confuse with WATER shut-off valves. 10) Rotate thermostat fully counterclockwise and set the Mode selector switch to PROGRAM 2. 11) Plug the unit into the proper outlet (120-volt system) or turn on the breaker at the electrical service panel (240-volt system). 12) On units with a Ground Fault Circuit Interrupter (GFCI), check the GFCI by pressing the Test button on the face of the device. The Reset button should pop out. The equipment should not operate. 13) Activate the equipment by pressing the Reset button on the GFCI. (If the jet pump(s) or blower is operating, switch them off) 14) Press the JET PUMP switch to run on high speed. Allow to run until you achieve a strong, steady water flow (free of air bubbles). 15) On systems with a pressure filter, bleed off the trapped air by opening the Air-Relief valve. You will notice a steady flow of water when the air has been bled completely. 16) Switch the JET PUMP off. 17) If equipped, switch the BLOWER on to verify that it is working, then switch it off. 18) If equipped, switch the LIGHT on to verify that it is working, then switch it off. 19) If equipped, switch the AUXILIARY PUMP on to verify that it is working, allow to run until all air is evacuated from the plumbing system, then switch it off. 20) Rotate the thermostat fully clockwise to the MAX position (the pump low speed and heater will now be operating). After the water has attained your desired temperature set the program mode switch to PROGRAM 1. Be sure the timer operation is set. 9

SPECIAL CONSIDERATIONS The equipment should be installed so that there is safe access for servicing and routine maintenance. After filling the spa or hot tub each time it is important that the pump be operated on high speed for several minutes to insure that all the air has been removed from the plumbing before the heater is turned on. Trapped air can cause the heater to dry-fire, which is not covered under the warranty. Factory Installed Pressure Switch: The heater comes equipped with a pressure switch. The pressure switch is a safety device that will not allow the heater to activate unless there is water flowing through it. A restricted water flow (dirty filter, obstruction in the spaplumbing ) can cause the pressure switch to react abnormally. Installation Below Spa Surface: If the heater is installed more than two (2) feet below the spa water level, adjustment of the pressure switch may be necessary. The following procedures and illustrations outline the adjustment of the pressure switch. CAUTION: Remove all power to the System prior to attempting any adjustments. Water Level 2.3 fee t = 1lb. 4. 6 feet = 2lb. 6.9 fee t = 3lb. Installation of heater in feet below water level Water Weight in pounds 9.2 feet = 4lb. 11. 5 fe et = 5lb. Adjustment 1) With power to System turned OFF, remove the wires from the pressure switch terminals (secure wires safely to prevent any chance of electrical shock). 2) Turn the Thermostat counter-clockwise to the OFF position. 4) Turn power to the System ON and activate the Low-Speed Pump. 3) Place an Ohmmeter across the pressure switch terminals to verify an OPEN circuit. 4) Rotate the pressure switch adjustment screw counterclockwise until the Ohmmeter indicates a CLOSED circuit. 5) Turn Pump OFF and verify that the pressure switch circuit is once again OPEN. 6) Turn power to the System OFF and reconnect pressure switch wires. Reapply power to the System and operate the spa or hot tub as normal. 10 Adjustment Screw Calibration Scale (1lb.) P S I 1 2 3

TROUBLESHOOTING NOTHING WORKS! System Mis-Wire light is ON - Line 1 or Line 2 connected to Neutral position. Main Breaker is OFF - Set to ON. Sub-Panel Breaker OFF - Set to On. System GFCI OFF - Press RESET. Power Switch in OFF position - Set to On. Components not plugged in - Plug in components. Power cord not plugged in - Plug in power cord. Overheat Protection Switch Tripped - Press button to reset. NO, LOW or SURGING WATER FLOW Air-Lock in plumbing system - Bleed the system. Restricted Water Flow - Insure that the water shut-off valves are open and that suction fittings are not blocked by debris. Dirty Spa Filter - Clean or replace filter. Low Water Level - Increase water level to manufacturers recommended level. NO LOW SPEED PUMP OPERATION Timer Not Programmed - Set function mode to desired setting and program timer. Overheat Protection Switch Tripped - Press button to reset. Mode Switch set in Mode 2 - Thermostat needs to be turned up to desired temperature. Pump Not Plugged in - Plug in the Pump. NO JETS or BLOWER OPERATION Air Button to Air Switch Hose Not Properly Connected - Connect hose. Blower or Pump Not Plugged In - Plug in the Blower or Pump. Overheat Protection Switch Tripped - Press button to reset. NO THERAPY JET OPERATION Water Shut-Off Valves are Closed - Open Shut-Off valves. Dirty Spa Filter - Clean or replace filter. Jets Not Properly Adjusted - Adjust Jets per manufacturers instructions. Diverter Valve Not Properly Adjusted - Adjust diverter valve. Pump Thermal Overload Tripping - Check for proper voltage and/or restricted water flow. Overheat Protection Switch Tripped - Press button to reset. NO HEAT! Thermostat Not Set Correctly - Adjust Thermostat setting. Overheat Protection Switch Tripped - Press button to reset. System In Wrong Mode - 120V Systems will not have heat if High-Speed Pump or Blower is on. Low Water Flow - Clean or Replace filter. Pressure Switch Not Properly Adjusted - Adjust Pressure Switch. HIGH HEAT! Temperature Sensor Not in Dry-wel - Place sensor in dry-well. Thermostat Set Too High - Adjust Thermostat Setting. High Ambient Temperature - Remove spa cover. GFCI TRIPS OCCASIONALLY Lightning or Electrical Storm, Power Surge, Extremely Humid Weather Conditions, or Radio Frequency Interference - Reset GFCI. NOTE: Assure that the GFCI is properly grounded and bonded. GFCI TRIPS IMMEDIATELY! Defective Component - Contact the factory for assistance. 11

The System Data Label is located on the control box. This label is very important and contains information you will need to establish your electrical service. The voltage and amperage ratings are shown on the bottom of the label. Product, Model, Serial and Code numbers are also shown on the label. Note: This information will be necessary if you should ever have to request warranty or any other type of service. ORDER CODE: MODEL: SERIAL: CODE: VOLTS: AMPS: PRODUCT: REFER TO NEC FOR BREAKER SIZING 12

NOTES Dealer: Contact: Date of Install: Phone: Address: City: State: Zip: Notes: 13

85-0100B-P Rev.1 01.04