Model 7501/7501T/7501TH/7501T240/7501T240H Portable Eyewash/Portable Eyewash with Heater

Similar documents
Model 7500EB Portable Eyewash with Heater

Model 7603/7603T/7603T240 Portable Eyewash / Portable Eyewash with Heater

Model 7603BL/7603BL240 Heated Blanket for 7603 Portable Eyewash

Model 7656WCC Eye/face Wash

Model 8330 Stainless Steel Combination Shower Eye/Face Wash

Model 8356WCSM Pull-Down Shower Eye/Face Wash

Model /8300CRP-8309CRP Shower & Eye/Face Wash

Model /8320CRP Shower and Eye/Face Wash

Model 8356WCC Pull-Down Shower Eye/Face Wash

Model Combination Shower Eye/Face Wash

Model 8300FP Freeze Resistant Combination Shower Eye/Face Wash

Model TWBS.SHE Tempered Water Blending System

Model 9201EFE Tempered Water Blending System

Model 9201EW Tempered Water Blending System

Model TWBS.EW.H Tempered Water Blending System

Model 9001, Alarm

Model 9001, Alarm

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model 1011/1011HPS Drinking Fountain

Model 8730 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Outdoor Shower and Eyewash System General Area Classification & Class I Division 2

Model 1900 Retrofit Bottle Filler

Model 7611 Eye/Face Wash

INSTALLATION & TESTING MANUAL

Model H1011.8/H1011.8HPS Water Cooler

Model 8780 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Tempering Skid General Area Classification & Class I Division 2. No.

INSTALLATION & TESTING MANUAL

3121FR Pedestal Mounted Drinking Fountain

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

Model 1920/1920HPS/1920W Bottle Filler

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

H Barrier-Free Wall Mounted Electric Drinking Fountain

H Barrier-Free Wall Mounted Electric Drinking Fountain

SELF-CONTAINED POWER MISTER

H1011.8HPS Barrier-Free Wall Mounted Electric Drinking Fountain

8317CTFP AXION MSR COMBINATION EYE / FACE WASH & DRENCH SHOWER Freeze Resistant

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

EMERGENCY DRENCH SHOWER

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

MIGHTY PRO 1/4 HP CHILLER

Pressurized Filter Up to 1250 gallons

Air Pump Up to 800 gallons

Retro-DWS Internal Heating Cable System for Non-Pressurized Sewer and Waste Drain Pipes

Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

User s Manual and Operating Instructions

Instruction Manual. Nacho Cheese Dispenser and Warmer

2001 Smith Eastern Corporation

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

A2Z Ozone, Inc. PRODUCT MANUAL

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

Ozone + UV Sanitation

INSTRUCTIONS FOR OPERATION AND CARE OF

K Specifications. Max. Water Volume

20-GALLON PARTS WASHER OWNER S MANUAL

model1117l with1920 ADA Compliant Dual Wall-Mount Fountain and Bottle Filler FEATURES & BENEFITS MODEL CHOICES OPTIONS SPECIFICATIONS


CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

IW-25-2 Dehumidifier Installation & Operations. Manual

Citation Models #2001, 2001ST, 2001BN Instruction Manual

Next Generation Corona Discharge Auto Voltage Sensing Installation Manual

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Contents. Eye/Face Washes... 3 Eyewashes... 3 Swing-Away Eyewashes... 4 Eyewash/Drench Hose Units... 4 Emergency Showers... 4 Safety Stations...

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

INSTALLATION, OPERATION AND MAINTENANCE

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

INSTRUCTIONS FOR OPERATION AND CARE OF. P.O. Box 3527 City of Industry, CA, , U.S.A

17 GALLON PROFESSIONAL RESTROOM CLEANER

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

INSTRUCTIONS FOR OPERATION AND CARE OF

installation, operation & Maintenance manual Floor-mounted Induction units

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

BURWELL BIDET TOILET SEAT INSTALLATION

Desiccant Tank Retrofit Kit for CD100/CS101 dehumidifying dryers

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Installation & Operation Manual for WarmlyYours Towel Warmers

EMERGENCY EYEWASH AND SHOWER TECHNOLOGY

User s Manual and Operating Instructions

(HSTAT Series) Instruction Manual

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Condiment Warmer. Instruction Manual Models #2252EX & #2253EX. Cincinnati, OH USA. Model #2252EX. Model #2253EX

Econo-16 Models 2024EX, 2024STX 16oz. Popcorn Machine Instruction Manual

CFC-FREE CB-60/CB-80 Cryobath Low Temperature Bath. Thermo NESLAB Manual P/N U00551 Rev. 04/03/00. Instruction and Operation Manual

17 U.S. gallon portable low profile drain with electric pump

55-Gallon Dispenser Package

Installation & Operation Manual for WarmlyYours Towel Warmers

Operation, Maintenance and Installation Manual

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

Transmission Cooling System J Operation Manual. TRANSFLOW Transmission Cooling System Service Tool J

K Specifications. Max. Water Volume

Transcription:

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS No. 2080045(15) Model 7501/7501T/7501TH/7501T240/7501T240H Portable Eyewash/Portable Eyewash with Heater NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY HAWS warrants that this specific product is guaranteed against defective material or poor workmanship for a period of one year from date of shipment. HAWS liability under this warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods, or part thereof, which shall appear to the Company upon inspection to be of defective material or not of first class workmanship, provided that claim is made in writing to Haws within a reasonable period after receipt of the product. Where claims for defects are made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, or for any expense connected therewith made by the owner or his agents, except upon written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective materials or poor workmanship, except for replacements, as provided above. Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated, except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general, special, or consequential damages claimed to arise under the contract of sale. The emergency equipment manufactured by HAWS is warranted to function if installation and maintenance instructions provided are adhered to. The units also must be used for the purpose for which they were intended. This product is intended to supplement first-aid treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this emergency equipment will prevent serious injury or the aggravation of existing or prior injuries. NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR GIVEN BY HAWS. SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS MODEL PLEASE CALL: TECHNICAL SUPPORT: 1-800-766-5612 FOR CUSTOMER SERVICE: 1-888-640-4297 08/16 Model 7501/7501T/7501TH/7501T240/7501T240H Page 1 of 8

RECOMMENDED TOOLS: Three 1/4" diameter anchors suitable for supporting filled eyewash (approximately 80 pounds), and tools needed to install these anchors. LOCATION OF UNIT: The Model 7501/7501T/7501TH/7501T240/7501T240H Portable Eyewash should be installed in close proximity to potential accident areas. It should be clearly identified, free from obstructions and easily accessible. NOTE: Personal wash unit Model 7501T/7501TH/7501T240/7501T240H shall be protected from freezing. Models 7501/7501T/7501TH/7501T240/7501T240H shall not be exposed to ambient temperatures exceeding 38⁰C (100⁰F). ELECTRICAL CONNECTIONS: Model 7501T requires a 120VAC, three-prong outlet, and is supplied with a heavy-duty 8 foot power cord with GFCI plug. Model 7501T240 requires a 240VAC outlet and is not supplied with a power cord which must be installed by the user. Model 7501T240 MUST BE PROTECTED BY a Class A GROUND FAULT CIRCUIT INTERRUPTER (GFCI). Models 7501TH and 7501T240H must be protected by a Class A Ground Fault Circuit Interrupter (GFCI)- No power cord is supplied Units are suitable for installation and use in Class 1, Division 2, Group B, C, D, T6, Class 2, Division 2, Group E, F, G areas and MUST BE INSTALLED IN COMPLIANCE WITH LOCAL, STATE AND/OR FEDERAL CODES. INSTALLATION INSTRUCTIONS NOTES: STEP 1: Instructions apply to all models unless otherwise specified. Model 7501: Mount unit to wall utilizing J bracket (supplied). Note: ¼ mounting hardware not supplied. See Installation Drawing on Page 7 of 8. STEP 2: IMPORTANT: Model 7501T/7501T240: Install blanket and power cord per instructions provided with blanket. Mount unit to wall utilizing J bracket and three aluminum spacers (supplied). Locate one aluminum spacer behind each bolt hole in J bracket. Note: ¼ mounting hardware is not supplied. See Installation Drawing on Page 8 of 8. Make sure portable eyewash unit is level from front to back and left to right before securing bracket to wall. Eyewash nozzles should be between 33 inches (83.8 cm) and 53 inches (164.6 cm) above the floor when eyewash arm is in the active (lowered) position (See Installation Drawings, pages 7 and 8 of 8). STEP 3: DO NOT FILL PAST WATER FILL LINE AS LEAKAGE WILL OCCUR AT THE EYEWASH HEADS. Filled eyewash unit is heavy (approximately 80 pounds). Wall bracket anchors (Quantity 3 - not supplied) must be strong enough to support the filled eyewash and the weight of a worker leaning on eyewash. Fill up to fill line (see important note above). Requires 8.75 gallons (max) of water, (make sure that no debris or contaminants of any kind are present in the flushing fluid). Make sure unit is level from front to back and left to right. If installed as indicated, eyewash unit will provide 15-minute duration of flow. CAUTION MAKE SURE MODEL 7501T/7501TH/7501T240/7501T240H EYEWASH UNIT IS FILLED WITH FLUSHING FLUID (UP TO FILL LINE) BEFORE CONNECTING HEATER TO POWER SOURCE. 08/16 Model 7501/7501T/7501TH/7501T240/7501T240H Page 2 of 8

STEP 4: STEP 5: Model 7501T/7501TH/7501T240/7501T240H: Connect heater to power source (See Electrical Connections above). Take proper precautions to help prevent the growth of potentially harmful bacteria in eyewash tanks. (Refer to Maintenance Instructions). OPERATING INSTRUCTIONS Instruct all employees in the use of this Emergency Eyewash. Personnel should be assigned to check eyewash liquid level daily. STEP 1: STEP 2: STEP 3: STEP 4: NOTE: Lead patient to nearest eyewash station. Seconds can make the difference in preventing serious eye injury. Pull yellow eyewash arm firmly. Eyewash arm will drop to activate eyewash. Lower head until eyes enter eyewash stream. Use thumbs and forefingers to hold eyelids open. Flush for 15 minutes. Seek qualified medical attention immediately. MAINTENANCE INSTRUCTIONS Customer must provide an inspection tag and maintain a record of inspection dates and type of maintenance performed (i.e. adding Sterile Antimicrobial Preservative Model 9082, etc.) Acanthamoeba survive mild chlorination and are commonly found in tap water. Sterile Antimicrobial Preservative Model 9082 will prevent the growth of Acanthamoeba. Hot water, 158º F (70º C) or hotter will destroy Acanthamoeba but must be allowed to cool prior to use in eyewash units. STEP 1: Self contained eyewash equipment shall be visually checked to determine if flushing fluid needs to be changed or supplemented. See STEP 3 for additional information regarding activated units. Frequency of inspection: Depending on environmental conditions, visual inspections should be performed on either a daily, weekly or monthly basis as some water loss will occur due to natural evaporation process. STEP 2: Take proper precautions to help prevent the growth of potentially harmful bacteria in eyewash tanks. We recommend either of the following procedures: A. Procedure 1: Use suitable Sterile Antimicrobial Preservative Model 9082 to help prevent the growth of bacteria in eyewash tank. Eyewash tank should be drained, flushed and refilled with clean potable water and Sterile Antimicrobial Preservative Model 9082 as directed by the preservative s manufacturer. NOTE: Disconnect Model 7501T/7501TH/7501T240/7501T240H from power source before performing maintenance. B. Procedure 2: Drain, flush and refill portable units with clean potable water at least once every week. Thoroughly cleanse tank at least once every month. 08/16 Model 7501/7501T/7501TH/7501T240/7501T240H Page 3 of 8

STEP 3: After activating units for whatever reason, ensure the following steps are implemented: A. Refill tank with potable water to the watermark line. B. If water is discharged for any reason follow Procedure 1 or Procedure 2 of Step 2 above to ensure that water quality is maintained. 08/16 Model 7501/7501T/7501TH/7501T240/7501T240H Page 4 of 8

TROUBLESHOOTING PROBLEM REPAIR CHECKLIST 1. No flow. 1. a. Tank empty. Refill tank (8.75 gallons). b. Obstruction in line or fitting. Clear obstruction. 2. Poor flow from eyewash head(s). 2. a. Tighten head assembly. b. Check for obstructions. If necessary, remove eyewash head(s), clean and reassemble. To reassemble head, place cap screw through head and thread into head anchor two or three turns. Tilt head assembly and work anchor legs into eyewash armholes. Tighten assembly. Check for leaks. 3. Water leak between joints or fittings. 3. a. Pull hose off fitting. Smooth raised plastic edge on center of fitting. Return hose and hose clamp to original position. b. Tighten hose clamp(s) with pliers. 4. Water leaking from eyewash heads. 4. a. Check to see if water level has exceeded water fill line (indicated on side of unit). If so, remove excess water till fill line is reached. b. Make sure unit is level from front to back and left to right. 5. Eyewash flows for less than 15 minutes. 5. a. Fill water level in eyewash tank even with water fill line (indicated on side of unit. 6. Excessive water loss 6. a. Check unit for leaks. Some loss due to evaporation is normal. 7. Heater doesn t turn on. (Model 7501T/7501TH/7501T240/7501T240H) 7. a.1 a.2 b. 7501T/7501T240: Not plugged in or no power to outlet. 7501TH/7501T240H: No power to unit. Check GFCI and/or circuit breaker. c. If ambient temperature is high and doesn t allow the water temperature to drop below 68 F (20 C) the heater may not switch on. Heater settings are: Non-adjustable thermostat preset to switch at 73 F ± 5 F (23 ± 3 C). Test the thermostat and heater function by applying ice in a circular motion to thermostat location. Apply ice to this location for approximately 3-5 minutes. The heat trace cable should become warm to the touch when operating properly. Thermostat locations are indicated on Installation Drawing page 8 of 8. 2016 Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation 08/16 Model 7501/7501T/7501TH/7501T240/7501T240H Page 5 of 8

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. PARTS BREAKDOWN STANDBY "OFF" 2 4 3 ITEM DESCRIPTION PART NO. 1 EYEWASH HEAD ASSY SP19 2 BRACKET 0001217418 3 CAP SP131 4 LABEL, CAP, REFILL 0003163925 5 STERILE ANTIMICROBIAL PRESERVATIVE 9082 6 ALUMINUM SPACER 0310000166 7 BLANKET *SEE TABLE NOT SHOWN 6 3X 7 ACTIVE "ON" (7501T SHOWN) 1 5 * MODEL BLANKET P/N MODELS 7501T/7501TH/ 7501T240/7501T240H 7501T 7501T240 7501BL 7501BL240 (NOT SUPPLIED, MUST BE ORDERED SEPARATELY) 7501TH 7501T240H 7501BLH 7501BL240H 2 STANDBY "OFF" 4 NOT SHOWN 3 5 MODELS 7501 1 ACTIVE "ON" (NOT SUPPLIED, MUST BE ORDERED SEPARATELY) 1455 KLEPPE LANE SPARKS, NEVADA 89431 (775) 359-4712 FAX (775) 359-7424 E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM ECN NO. REVISED PER BY MODEL(S) PART NUMBER 5086 ECN: 5139 CC DRAWN DATE CHKD 7501/7501T/7501TH/7501T240/7501T240H REVISION RTM 04/16/04 VWC APPROVED DATE PORTABLE EYEWASH 15 FV 09/21/16 SCALE: 1:1 DRAWING TYPE: PARTS BREAKDOWN SIZE: A SHEET 1 OF 1 WHEN ORDERING PARTS PLEASE SPECIFY MODEL NUMBER. C 2016 Haws Corporation - All Rights Reserved R HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 0002080045 PAGE 6 of 8

PAGE 7 of 8 THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. MOUNTING BRACKET (SUPPLIED) 3 3X 1/4" MOUNTING HARDWARE (NOT SUPPLIED) 1 1/4" [32mm] 2 1/4" [57mm] 1 1/8" [29mm] DO NOT EXCEED WATER FILL LINE.REFER TO INSTALLATION INSTRUCTIONS IN "OPERATION AND MAINTENANCE MANUAL" FOR PROPER FILLING PROCEDURES. 3X ø 5/16" ø [8mm] 3 * 10-1/8" [257mm] * 14-1/2" [368mm] * 21-1/2" [546mm] * 22" [559mm] STAND BY "OFF" 54-1/2" TO 66-1/2" [1384mm TO 1689mm] TO FINISHED FLOOR * 8" [203mm] * 22" [559mm] ACTIVE "ON" 33" TO 53" [838mm TO 1346mm] TO FINISHED FLOOR * 16-3/4" [425mm] FLOOR LINE C NOTES: 1. TO COMPLY WITH ANSI Z358.1-2014 FOR EMERGENCY EYEWASH OR EYE/FACE WASH AND SHOWER EQUIPMENT: - UNIT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND ACCEPTABLE PLUMBING PRACTICES. - EYEWASH OR EYE/FACE WASH SHALL BE ED WITH NOZZLES NOT LESS THEN 83.8 CM (33 IN.) AND NO GREATER THAN 134.6 CM (53 IN.) FROM SURFACE ON WHICH USER STANDS AND 15.3 CM (6 IN.) MINIMUM FROM WALL OR NEAREST OBSTRUCTION. 2. UNIT MUST BE LEVEL FROM FRONT TO BACK AND SIDE TO SIDE. 3 ALL THREE MOUNTING HOLES ON MOUNTING-BRACKET MUST BE USED TO PROPERLY SECURE EYEWASH UNIT TO WALL. (NOTES CONTINUED ON SHEET 2 OF 2) 2016 MODEL 7501 (SHOWN) MODELS 7501T/7501TH/7501T240/7501T240H - WITH HEATED BLANKET (SEE SHEET 2 OF 2) ECN NO. REVISED PER BY: 5086 ECN: 5139 CC DRAWN: DATE: CHK'D.: MJ 06/30/16 VWC APPROVED: DATE: FV 09/21/16 MODEL(S) PORTABLE EYEWASH 7501/7501T/7501TH/7501T240/7501T240H 1455 KLEPPE LANE SPARKS, NEVADA 89431 (775) 359-4712 FAX (775) 359-7424 E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM PART NUMBER REVISION SCALE: 1:1 DRAWING TYPE: INSTALLATION SIZE: A SHEET 1 OF 2 R Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 0002080045.D 15

PAGE 8 of 8 THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. OVER-TEMP THERMOSTAT MOUNTING BRACKET (SUPPLIED) 3 3X 1/4" MOUNTING HARDWARE (NOT SUPPLIED) 1 1/4" [32mm] 2 1/4" [57mm] 1 1/8" [29mm] 3X Ø 5/16" 3 Ø [8mm] DO NOT EXCEED WATER FILL LINE. REFER TO INSTALLATION INSTRUCTIONS IN "OPERATION AND MAINTENANCE MANUAL" FOR PROPER FILLING PROCEDURES. * 12-1/2" [318mm] 1/2" THICK SPACERS 4 * 15-3/4" [400mm] 7501T SUPPLIED WITH GFCI 8' POWER CORD (120VAC, 60Hz, 200W) * 22" [559mm] * 21-1/2" [546mm] STAND BY "OFF" 54 1/2" TO 66 1/2" [1384mm TO 1689mm] TO FINISHED FLOOR * 8" [203mm] * 24" [610mm] FLOOR LINE ACTIVE "ON" 33" TO 53" 838mm TO 1346mm TO FINISHED FLOOR * 18" [457mm] NOTES: (CONTINUED FROM SHEET 1 OF 2) 4 LOCATE ONE 1/2" THICK SPACER (QTY. 3 SUPPLIED) BEHIND EACH HOLE IN THE MOUNTING BRACKET AS SHOWN. 5. * DIMENSIONS MAY VARY ±1/2" [12.7mm]. 6. (FOR MODELS 7501T240 & 7501BL240:) 7. CORD SET SHALL BE LISTED TO UL 817 AND CSA-C22.2 NO. 21 AND PROVIDED WITH 3 WIRE GROUNDING TYPE ATTACHMENT PLUG RATED 240 V, MIN. 15 A. 8. THE FLEXIBLE CORD TYPE SHALL BE TYPE S, SE, SJ, SJE, SJO, SJOO, SJT, SJTO, SJTOO, SO, SOO, ST, STO, OR STOO AND HAVE A TYPE LETTER SUFFIX OF "W," "W-A" OR "OUTDOOR." 9. THE CORD SET SHALL BE MIN. 6 FT IN LENGTH AND MIN 18 AWG SIZE FOR FLEXIBLE POWER SUPPLY CORD. 10. LISTED STRAIN RELIEF BUSHING SUITABLE FOR CORD SET SIZE AND OUTDOOR USE SHALL BE USED. 11. THE FIELD INSTALLED POWER SUPPLY CORD SET NEEDS TO BE INSTALLED BY QUALIFIED PERSONNEL. 2016 ECN NO. REVISED PER BY: 5086 ECN: 5139 CC DRAWN: DATE: CHK'D.: MJ 06/30/16 VWC APPROVED: DATE: FV 09/21/16 PART NUMBER REVISION SCALE: 1:1 DRAWING TYPE: INSTALLATION SIZE: A SHEET 2 OF 2 Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. C R MODELS 7501T/7501TH/7501T240/7501T240H - WITH HEATED BLANKET (SHOWN) MODEL 7501 (SEE SHEET 1 OF 2) MODEL(S) PORTABLE EYEWASH 7501/7501T/7501TH/7501T240/7501T240H 1455 KLEPPE LANE SPARKS, NEVADA 89431 (775) 359-4712 FAX (775) 359-7424 E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM 0002080045.D 15