Design and performance evaluation of vacuum cleaners using cyclone technology

Similar documents
An Experimental Study of the Air-Side Particulate Fouling in Fin-and-Tube Heat Exchangers of Air Conditioners

A STUDY ON THE DEVELOPMENT OF A DEODORIZATION UNIT FOR THE TOILET BIDET

Heat transfer property of refrigerant-oil mixture in a flooded evaporator: The role of bubble formation and oil retention

A Study on Cooling Rate with Blade and Sound Fire Extinguisher

PERFORMANCE OF A MODEL IN-LINE VORTEX SEPARATOR. Keng-Choon Lee Geothermal Institute, The University of Auckland, Private Bag 92019, Auckland, New

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Effect of Heat Exchanger Configuration on the Performance of Joule-Thomson Refrigerators

Performance Characteristics of a Refrigerator- Freezer with Parallel Evaporators using a Linear Compressor

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

A Study on a Suitability of Sound Fire Extinguisher in Duct Environment

Application of a divided wall column for gas separation in floating liquefied natural gas plant

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

Analysis of Triangle Heating Technique using High Frequency Induction Heating in Forming Process of Steel Plate

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Control Method Of Circulating Refrigerant Amount For Heat Pump System

[1] Lecture 2 Particulate emission control by mechanical separation & wet gas scrubbing

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

M O D U L E IV C O N T R O L T E C H N I Q U E S

Division III Process Gas Treatment Equipment

ISO AIR FILTERS FOR GENERAL VENTILATION: DETERMINING FRACTIONAL EFFICIENCY

REDUCTION OF NOISE AND VIBRATION OF FRONT LOADING WASHING MACHINE IN SPIN-CYCLE

A Literature Review On Heat Exchanger Air Side Fouling In Heating, Ventilation And Airconditioning

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

solution, due to the partial vapor pressure difference between the air and the desiccant solution. Then, the moisture from the diluted solution is rem

Boiler Draft Equipment

Performance Analysis of Centrifugal Fan by CFD

Article Energy Saving Benefits of Adiabatic Humidification in the Air Conditioning Systems of Semiconductor Cleanrooms

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

Specialized in the design and the tailor-made production of dryers, coolers and thermal processing equipment for industrial use.

CARE GUIDANCE. Local Exhaust Ventilation (LEV) Systems for High Temperature Insulation Wool (HTIW) LEVEL 2 RECOMMENDATIONS ON BEST PRACTICE

AEROSOL SEPARATION PARTICLE CHARACTERISTICS 27/11/2010

ecodry Figure 1 - Process Diagram ecodry B General Process Description

A Project of Cleaning Smog and Particulates by Using Smog Cleaner with Negative-Ion Generator

Global Journal of Engineering Science and Research Management

Modified geotextile tube a new geotextile tube for optimized retaining efficiency and dewatering rate

Efficient Vacuum Conveyors Deliver Cost-Effective Solutions Pick-up, conveying and feeding of powders, granules and other bulk materials

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former

A STUDY ON THE APPLICABILITY OF THE TIME-DIVISION HOT-WATER SUPPLY HEATING FOR ONDOL - THE RADIANT FLOOR HEATING SYSTEM IN KOREA

DESIGN AND FABRICATION OF ELECTRO STATIC PRECIPITATON IN AUTOMOBILE

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

Australian Journal of Basic and Applied Sciences

Module 5: Combustion Technology. Lecture 38: Combustion Burners

APPLICATION PROFILE EXPLOSIONS IN CEMENT PLANTS EXPLOSIONS IN CEMENT PLANTS CEMENT PLANT EQUIPMENT WITH HIGHEST EXPLOSION POTENTIAL. Form No.

FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE

Analysis of the influence of open door size on fire smoke diffusion law in protective engineering

Effects of seawater flow rate and evaporation temperature on performance of Sherbet type ice making machine

LG Robotic Vacuum Cleaner

Adsorption refrigeration system using waste heat

CASE STUDIES OF THERMALLY DRIVEN HEAT PUMP ASSISTED DRYING. Minh Cuong Tran, Jamy Logie, Bruno Vanslambrouck, Martijn van den Broek

SPRAY DRYING SYSTEMS INC.

FIELD OF OPERATION. Multi cyclones Bag filter Flue gas fan Rotary locks Conveying systems Accessories for dust collection plants

An Analysis of Compartment Fire and Induced Smoke Movement in Adjacent Corridor

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

Coal Handling and Processing. Advanced Solutions for Coal-Related Environmental Dust Control. Better Air is Our Business

Hurricane Cyclones To Reduce Emissions of Dryer Cyclones in Glowood Pellet Plant April 2016

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

Keywords biomass boiler, biomass resource, Small scale sewage treatment plant, twin drum type dryer,

Development of the Micro Capillary Pumped Loop for Electronic Cooling

Base resistance of individual piles in pile group

final report Superheated Steam Blood Meal Dryer Keith Engineering Date published: March 2009

Effect of Impeller Clearance and Multiple Impeller Combinations on Solid Suspension in a Standard Flat Bottom Agitated Vessel

Liquid Ring Vacuum Pumps, Compressors and Systems

A study on performance improvement of corrugated type total heat exchanger considering the structure of flow passage on surface

Design of a high accuracy non-dispersive Infrared gas sensor for continuous emission monitoring of carbon monoxide emitted from an industrial stack

Hot Air-Microwave Combined Drying Characteristics of Gypsum Board. Won-Pyo Chun, Sung-Il Kim, and Ki-Woo Lee 1

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Optimized fan system design for the one-year cycle of a Heat Pump. Ziehl-Abegg SE Frieder Lörcher

Survey Says: Clean for Safety and Profitability

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

MULTI-CHANNEL R134A TWO-PHASE FLOW MEASUREMENT TECHNIQUE FOR AUTOMOBILE AIR-CONDITIONING SYSTEM

The Condensate Water Systems

FAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

MagixX & StuffNix. Exhaust air treatment systems for efficient reduction of emissions from poultry houses

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

Dust sensor SM-PWM-01A SPECIFICATION. Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12

PERFORMANCE EVALUATION AND RECURRING JAMMING PROBLEM ANALYSIS OF AIR PREHEATER IN COAL-FIRED POWER PLANTS

Heat pump supplemental heating system for motor vehicles

Heated tools. Semiconductor equipment

EFFECT OF DIVERSE STREAM PATTERNS ON THE PERFORMANCE OF SOLAR AIR HEATER

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink

ADVANCED Series 15P1 17P2 19P2

Evaluation the Effect of Washing on the Heat Transfer Capacity and Air-Side Flow Resistance of Air Cooled Condensers

Drying Parawood with Superheated Steam

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Solid and Liquid Pollutants

Performance Analysis of Water-Water Heat Pump System of 100 kw Scale for Cooling Agricultural Facilities

EXPERIMENTAL PERFORMANCE INVESTIGATION OF SWIRLING FLOW ENHANCEMENT ON FLUIDIZED BED DRYER

ROTARY DRYER CONSTRUCTION

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Transcription:

Korean J. Chem. Eng., 23(6), 925-930 (2006) SHORT COMMUNICATION Design and performance evaluation of vacuum cleaners using cyclone technology Young Chull Ahn, Hoi Kil Jeong*, Hee Soo Shin**, Yu Jin Hwang**, Gil Tae Kim**, Seong Ir Cheong**, Jae Keun Lee**, and Chul Kim*** School of Architecture, Pusan National University, San 30, Changjeon-dong, Keumjeong-gu, Busan 609-735, Korea *LG Electronics, 76, Seongsan-Dong, Changwon City, Gyeongnam 641-713, Korea **Department of Mechanical Engineering, ***Research Institute of Mechanical Technology, Pusan National University, San 30, Changjeon-dong, Keumjeong-gu, Busan 609-735, Korea (Received 6 November 2005 accepted 8 June 2006) Abstract A cyclone technology for a vacuum cleaner--axial inlet flow cyclone and the tangential inlet flow cyclone-- to collect dusts efficiently and reduce pressure drop has been studied experimentally. The optimal design factors such as dust collection efficiency, pressure drop, and cut-size being the particle size corresponding to the fractional collection efficiency of 50% were investigated. The particle cut-size decreases with reduced inlet area, body diameter, and vortex finder diameter of the cyclone. The tangential inlet twin-flow cyclone has good performance taking into account the low pressure drop of 350 mmaq and the cut-size of 1.5 µm in mass median diameter at the flow rate of 1 m 3 /min. A vacuum cleaner using tangential inlet twin-flow cyclone shows the potential to be an effective method for collecting dusts generated in the household. Key words: Cut-size, Cyclone, Dust Collection Efficiency, Pressure Drop, Vacuum Cleaner INTRODUCTION A large fraction of our time is spent in houses, workplaces, or other buildings; therefore, indoor spaces should be comfortable both emotionally and hygienically. But indoor air contains more than twice the pollutants of outdoor air because of air tightness, poisonous chemicals, food smells, and ticks which are generated by the use of new materials and equipment in buildings. The vacuum cleaner is the representative home appliance for removing harmful materials from floors or carpets. The commercial vacuum cleaners used in houses consist of the paper filter, pre-filter, and exhaust filter through which the clean air discharges to the atmosphere. Though vacuum cleaners are convenient in use, the suction pressure decreases rapidly in proportion to the time of cleaning, and the paper filter also should be replaced periodically due to pressure drops, odors, and bacteria by the residual dust inside the paper filter [Cueno et al., 1997; Oh et al., 2004; Park et al., 2005; Yoa et al., 2001]. Fig. 1 shows that the size distribution of atmospheric aerosols is usually bi-modal in shape with particles in the coarse (>2.0 µm) mode being primarily of external sources, such as wind blown dust, sea salt sprays, volcanoes, and direct emission from industrial plants and vehicular emission, and those in the fine particle mode consisting of products of combustion or photochemical reaction [Liu and Pui, 1991; Whitby, 1978]. Table 1 shows the modes, mass median diameter, and mass concentration of the typical atmospheric aerosols measured by many investigators. Fine mode in the 0.18 to 0.36 µm size range and coarse mode in the 5.7 to 25 µm size range were measured. Mass concentration ranged from 2 to 205 µg/m 3 for atmospheric aerosols and 3.85 to 36.3 µg/m 3 for diesel aerosols [Knight et al., 1983; Lundgren et al., 1984; Whitby, 1983]. Indoor dusts are To whom correspondence should be addressed. E-mail: jklee@pusan.ac.kr Fig. 1. The bi-modal size distribution of atmospheric aerosols [Liu and Pui, 1991; Whitby, 1978]. Table 1. Typical parameters of atmospheric and diesel aerosols [Knight et al., 1983; Lundgren et al., 1984; Whitby, 1983] Particle type Geometric Mass Mass mean standard concentration, diameter, µm deviation µg/m 3 Fine mode 0.18-0.36 1.66-2.16 2.07-38.4 Coarse mode 5.7-25. -2 06.2-205. Diesel aerosol 0.15-0.50 1.62-2.10 3.85-36.3 affected directly by atmospheric aerosols and many fibers, which are separated from carpets, clothes, bedclothes, papers, and fur of pets, are contained additionally. Most indoor dusts from floors and carpets are coarse particles larger than 2 µm and these particles can be removed easily by using inertial forces. Generally, cyclones are used to collect coarse particles effectively by using centrifugal forces 925

926 Y. C. Ahn et al. Fig. 2. Schematic diagram of the conventional bag vacuum cleaner and the cyclone vacuum cleaner for this study. (a) Bag vacuum cleaner, (b) Cyclone vacuum cleaner which are a kind of inertial force. Therefore, it would be more desirable to change the paper filter to cyclone because it has low pressure drop and clean emission. This paper describes how to design and evaluate vacuum cleaner performance by using cyclone technology to meet the constant suction power, hygienic exhaust, and a reduction of maintenance cost, and to replace paper filters used in the conventional vacuum cleaner. PRINCIPLE OF THE VACUUM CLEANER Fig. 2(a) shows a schematic diagram of the commercial vacuum cleaner. The dust laden air inhaled by the vacuum cleaner is filtered through the paper filter for collecting large particles and fibers, followed by the pre-filter and the final filter for removing fine particles [Lee, 1999]. Sequentially, the cleaned air is exhausted to the atmosphere. High efficiency filters in conventional vacuum cleaners have been developed for better dust removal. But the residual dusts inside the paper filter of the conventional vacuum cleaner make some odors and germs unless the paper filter is replaced in a certain period. Therefore, the vacuum cleaner using the cyclone collector as shown in Fig. 2(b) by replacing paper filters used in the conventional vacuum cleaner is developed to prevent the problems of the conventional vacuum cleaners. The cyclone cleaner has constant suction power compared with the conventional vacuum cleaner of which suction power is rapidly decreased by accumulation of dusts in the paper filter. And the vacuum cleaner using cyclone technology can prevent odor problems by removing the dusts in the cyclone Fig. 3. Schematic diagram of the cyclone design for the vacuum cleaner. (a) Tangential inlet flow cyclone, (b) Tangential inlet twin-flow cyclone, (c) Axial inlet flow cyclone instantaneously. CYCLONE VACUUM CLEANER Fig. 3 shows the schematic diagrams of the cyclone design for the vacuum cleaner such as the tangential inlet flow cyclone, the tangential inlet twin-flow cyclone, and the axial inlet flow cyclone. In the tangential inlet flow cyclone in Fig. 3(a), the dust laden gas rotates by flowing from the tangentially connected inlet pipe into the cyclone body, and dusts are separated by centrifugal force, while the tangential inlet twin-flow cyclone has the inlet flow in the center of the cyclone body and the dust laden gas flows bi-directionally as shown in Fig. 3(b). A tangential inlet twin-flow cyclone being capable of the treatment of high flow rate is designed to decrease pressure drop through the cyclone. In the axial inlet flow cyclone in Fig. 3(c), the dust-laden gas in the cyclone body is rotated by the spiral vanes and the dust or solid particles are separated by centrifugal force. The clean gas flows to the atmosphere through the exit pipe. For improving the collection efficiency, the axial inlet flow cyclone can be attached with spiral vanes. Those cyclones include a dust box primarily removing the November, 2006

Design and performance evaluation of vacuum cleaners using cyclone technology 927 high density and large size materials like papers or plastics. In general, the axial inlet flow cyclone is used in parallel so as to deal with a large volume of gas at a low pressure drop, but the collection efficiency is not as high. A cyclone dust collector should have small and compact dimensions to fit inside the vacuum cleaner. The suction air flow rate of vacuum cleaner for residential use is normally in the range of 1-2 m 3 /min. It is a somewhat high volume flow rate with the consideration of applicable size of cyclone collectors. Therefore, axial inlet flow cyclone with a spiral vane is designed to meet with the high volume flow rate. EXPERIMENTAL RESULTS AND DISCUSSION The performance evaluations of the tangential inlet flow cyclone, the tangential inlet twin-flow cyclone, and the axial inlet flow cyclone are conducted by measuring the fractional dust collection efficiency, the pressure drop across the cyclone and the cut-size (d c ) which is the particle size corresponding to the fractional collection efficiency with 50%. The collection efficiency and the cut-size are measured with a particle counter (Mastersizer Microplus, Malvern), and the pressure drop is measured with a manometer (FC012-4, Furness Controls Limited). Spherical fly ashes are used as the test particles with particle sizes under 25 µm and mass concentration of 1 g/m 3. 1. Tangential Inlet Flow Cyclone Fig. 4 shows the effects of the airflow inlet area to affect the fractional dust collection efficiencies as a function of the ratio of the inlet area (A I ) and the cross sectional area (A B ) of the cyclone body. Centrifugal forces created by the change of flow direction move particles to the wall and separate particles from the air stream in the cyclone [Ogawa, 1984]. The centrifugal force increases with increasing flow velocity being inversely proportional to the inlet area. Inlet air velocities range from 11.1-55.6 m/s at the suction flow rate of 1 m 3 /min. The cut-size and the pressure drop through the cyclone at the A I /A B ratio of 0.16 are approximately 2.3 µm and 450 mmaq, respectively. The most penetrating particle size which shows the minimum collection efficiency is about 2 µm. It is believed that the dust collection efficiency of fine particles smaller than 2 µm increases due to agglomeration between fine particles and coarse particles in spite of decreasing the particle size. Fig. 5 shows the effects of the size of a vortex finder to the fractional dust collection efficiency. The ratio between the diameter of the vortex finder (D V ) and the diameter of the body (D B ) ranges from 0.275 to 0.475. The vortex finder creates circular flow streams and makes strong centrifugal forces. Especially, the small diameter of vortex finder causes stronger centrifugal forces. Therefore, the fractional dust collection efficiency increases with decreasing D V ratio. The design of the vortex finder is very important because the Fig. 4. Effects of the ratio between the inlet area (A I ) and the cross sectional area of the cyclone body (A B ) in the tangential inlet flow cyclone for the dust collection efficiency (Flow rate: 1m 3 /min). Fig. 5. Fractional dust collection efficiency of the tangential inlet flow cyclone as a function of ratio between diameter of vortex finder (D V ) (Flow rate: 1 m 3 / min). Korean J. Chem. Eng.(Vol. 23, No. 6)

928 Y. C. Ahn et al. Fig. 6. Effects of the ratio between the inlet area (A I ) and the cross sectional area of the cyclone body (A B ) in the tangential inlet twin-flow cyclone for the dust collection efficiency (Flow rate: 1 m 3 /min). Fig. 7. Fractional dust collection efficiency of the tangential inlet twin-flow cyclone as a function of ratio between diameter of outlet pipe (D O ) (Flow rate: 1m 3 /min). fractional dust collection efficiency decreases abruptly if the ratio of D V exceeds a certain limit. 2. Tangential Inlet Twin-Flow Cyclone Fig. 6 represents the effects of the ratio between the inlet area (A I ) and the cross sectional area of the cyclone body (A B ) in the tangential inlet twin-flow cyclone for the dust collection efficiency at the flow rate of 1 m 3 /min. The experiments are performed at an inlet area of 300, 600, and 1,000 mm 2 and are correlated with 55.6, 27.8, and 16.7 m/s, respectively. The cut-size and the pressure drop through the cyclone at the A I /A B of 0.06 are approximately 1.4 µm and 350 mmaq, respectively. Fig. 7 shows the fractional dust collection efficiency of the tangential inlet twin-flow cyclone as a function of ratio between the diameter of the vortex finder (D O ) and the diameter of cyclone body (D B ). The ratio of D O ranges from 0.275 to 0.463. The diameter of the vortex finder has an effect on the residence time of the dust laden air stream. The small diameter of the vortex finder causes long residence time and provides enough time to separate the dusts from air stream due to the long lasting centrifugal forces. Therefore, better fractional dust collection efficiency can be obtained at the D O ratio of 0.275. 3. Axial Inlet Flow Cyclone Fig. 8 shows the fractional dust collection efficiency of the axial inlet flow cyclone as a function of the ratio of spiral vane pitch (P) divided by the body diameter (D B ) at the flow of 1 m 3 /min. effect of the pitch of the spiral vane to the fractional dust collection efficiency. The ratio of P ranges from 0.50 to 0.88. The cut-size and the pressure drop through the cyclone at the P ratio of 0.88 are approximately 2.6 µm and 300 mmaq, respectively. The spiral vane creates circular flow streams and makes strong centrifugal forces but it can transport air and dust to the rear side of the cyclone when they pass through the spiral vane. The air and the dust move faster to the rear side when the pitch of the spiral vane is longer, whereas, since they still have still strong centrifugal forces, most of dusts are collected and clean air is exhausted. Fig. 9 represents the fractional dust collection efficiency of the axial inlet flow cyclone as a function of ratio between diameter of inlet pipe (D I ). Inlet air velocities range from 17.3-34.0 m/s when the suction flow rate of vacuum cleaner is 1 m 3 /min. The fractional dust collection efficiency of the axial inlet flow cyclone increases with decreasing inlet area due to more strong centrifugal forces at the small inlet area. Fig. 10 represents a comparison of the fractional dust collection efficiency of the cyclone cleaners used in this study in their optimized dimensions. The most penetrating particle size of the tangential inlet flow, the tangential inlet twin-flow, and the axial inlet flow cyclones range approximately 2.0 µm. The smallest cut-size of 1.4 µm is obtained at the pressure drop of 350 mmaq for the tan- November, 2006

Design and performance evaluation of vacuum cleaners using cyclone technology 929 Fig. 8. Fractional dust collection efficiency of the axial inlet flow cyclone as a function of ratio between pitch of spiral vane (P ) (Flow rate: 1 m 3 /min). Fig. 9. Fractional dust collection efficiency of the axial inlet flow cyclone as a function of ratio between diameter of inlet pipe (D I ) (Flow rate: 1 m 3 /min). gential inlet twin-flow cyclone. Table 2 shows the results of the performance evaluation for cyclone cleaners developed in this study. The cut-size and the pressure drop through the cyclone range from 1.4 to 2.6 µm and 300 to 450 mmaq, respectively. The tangential inlet twin-flow cyclone has the smallest cut-size of 1.4 µm at the pressure drop through the cyclone of 450 mmaq and the flow rate of 1 m 3 /min, while the tangential inlet flow cyclone shows highest pressure drop of 450 mmaq and the cut-size of 2.3 µm. It is believed that the tangential inlet twin-flow cyclone can be capable of the treatment of high flow rate and decrease pressure drop through the cyclone. Therefore, the tangential inlet twin-flow cyclone shows the potential to be an effective vacuum cleaner taking into account the cut-size and pressure drop through the cyclone. CONCLUSIONS In this paper, commercial design and performance evaluation of the tangential inlet flow cyclone, the axial inlet flow cyclone and the tangential inlet twin-flow cyclone for vacuum cleaners are conducted to meet the constant suction power, hygienic exhaust, and a reduction of maintenance cost, and to replace paper filters used in the conventional vacuum cleaner. The tangential inlet twin-flow cyclone has good performance, taking into account the low pressure drop of 350 mmaq and the cut-size of 1.4 µm in mass median diameter at the flow rate of 1 m 3 /min. A vacuum cleaner using the tangential inlet twin-flow cyclone shows the potential to be an effec- Fig. 10. Comparison of fractional dust collection efficiency of the various cyclone cleaners in their optimized dimensions (Flow rate: 1 m 3 /min). Korean J. Chem. Eng.(Vol. 23, No. 6)

930 Y. C. Ahn et al. Table 2. Performance evaluation for various cyclone cleaners Model Cut-size (µm) tive method to collect dusts generated in the household. ACKNOWLEDGMENT This work was supported by Pusan National University research grant. REFERENCES Pressure drop (mmaq) Noise (db) Tangential inlet flow cyclone 2.3 450 65 Tangential inlet twin-flow cyclone 1.4 350 65 Axial inlet flow cyclone 2.6 300 62 Cueno, M. E., Menge, P. R., Hanson, D. L., Fowler, W. E., Bernard, M. A., Ziska, G. R., Filuk, A. B., Pointon, T. D., Vesey, R. A., Welch, D. R., Bailey, J. E., Desjarlais, M. P., Lockner, T. R., Mehlhorn, T. A., Slutz, S. A. and Stark, M. A., Results of vacuum cleaning techniques on the performance of LiF field-threshold ion sources on extraction applied-b ion diodes at 1-10 TW, IEEE Transactions on Plasma Science, 25, 229 (1997). Knight, G., Bigu, J., Mogan, P. and Stewart, D. B., Size distribution of airborne dust in mines, in aerosols: In the mining and industrial work environments, V. A. Marple and B. Y. H. Liu, ed. Ann. Arbor. Science Publishers, 2, 419 (1983). Lee, J. K., Performance improvement and optimal design of a household vacuum cleaner using cyclone technology, Final Report, LG Electronics Inc. (1999). Liu, B. Y. H. and Pui, D. Y. H., Aerosols, Encyclopedia of Applied Physics, 1, 415 (1991). Lundgren, D. A., Hausknecht, B. J. and Buton, R. M., Large particle size distribution in five U.S. Cities and the effect on a new ambient particulate matter standard (PM10), Aerosol Science and Technology, 467 (1984). Ogawa, A., Separation of particles from air and gases, CRC Press Inc. (1984). Oh, J. S., Choi, Y. H., Park, J. B. and Zheng, Y. F., Complete coverage navigation of cleaning robots using triangular-cell-based map, IEEE Trans. Ind. Elec., 51, 718 (2004). Park, Y., Yun, C. Y., Yi, J. and Kim, H., Numerical simulation of the effects of the design feature of a cyclone and the inlet flow velocity on the separation of CO 2 particles from a CO 2 -COF 2 mixture, Korean J. Chem. Eng., 22, 697 (2005). Whitby, K. T., The physical characteristics of sulfur aerosols, in Sulfur in the Atmosphere, ed. Pergamon (1978). Whitby, K. T., Size distribution of airborne dust in mines, in aerosols: In the mining and industrial work environments, V. A. Marple and B. Y. H. Liu, ed. Ann. Arbor. Science Publishers, 2, 363 (1983). Yoa, S. J., Cho, Y. S., Choi, Y. S. and Baek, J. H., Characteristics of electrostatic cyclone/bac filter with inlet types (lab and pilot scale), Korean J. Chem. Eng., 18, 539 (2001). November, 2006