BFC Cyclone Condensing Glass-Lined Water Heater

Similar documents
BFM Balanced flue commercial water heater

SGE Condensing Gas - Solar Water Heater

SGS Condensing High Efficiency Gas-Solar Water Heater

Boiler systems Upsilon Cascade. Innovation has a name.

BFM. Balanced Flue Commerial Water Heater BFM - 30/50/80/100/120. Installation, User and Service Manual. Innovation has a name.

Theta Dual service BFC, SGE, SGS for 20/30/40 kw heating capacity

ADMP. Commercial Atmospheric Water Heater ADM - 40/50/60/80/90/115. Installation, User and Service Manual. Innovation has a name.


Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

MAINTENANCE AND SERVICE GUIDE

>40 80 mm. Dishwasher EN Installation instructions. Appliance components >40. Recess for pipes >80. Front panel/decorative system.

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

FEATURES AND BENEFITS. Up to 109.8% part load efficiency


1 VICTRIX ZEUS Superior kw I features

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

Commercial Tankless Rack System

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

... UDSA - UDSBD Gas fired unit heaters...

Gas Storage Water Heaters CONVENTIONAL FLUE FAN FLUED BALANCED FLUE DIRECT STORAGE TANKS

Commercial Tankless Rack System

AXIAL HEATER TROUBLE SHOOTING GUIDE. Models: AX24 N/PV, AX24 N/PV LT, AX24 LP AX26 N/PV, AX26 N/PV LT, AX26 LP AX28 N/PV, AX28 N/PV NT, AX28 LP

Hamworthy Dorchester DR-FC Evo 98%

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

WOLF GAS CONDENSING BOILERS COMFORTLINE

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER

RG7D 1-Stage Heat Series

Commercial Tankless Rack System

FASTflo. Working towards a cleaner future

CI/Sfb. (53.5) Xh. March Conventional Flue Fan Flued Balanced Flue Direct Storage Tanks

GHP AWO 38 Technical overview

A Guide to Commercial Hot Water from Hamworthy. Introducing Hamworthy s Product Ranges for Hot Water Generation:

BENSON GAS UNIT HEATERS

VICTRIX Superior kw Export VICTRIX Superior kw X Export

CBX 24, 32 & 38 SBX 30

Clear Installation guide

Commercial Tankless Rack System

BOSCH CONDENS 5000W ZSB18-2A

WOLF WALL MOUNTED GAS CONDENSING BOILERS COMFORTLINE

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

MODEL BTI 65 G InsTALLATIOn AnD user InsTRucTIOn united kingdom / IRELAnD HOT WATER storage HEATER

Our room heating product range include models that run on gas or electric or. Our innovative underfloor models help vehicle designers to free up space

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

30 SD & 45 SD CONDENSING BOILERS

POWER VTX. Condensing Storage Water Heater. 500 to 1000 MBH 225 Gallon Tank 15-year Warranty. PVI.com ENGINEERED DUPLEX ALLOY

HeatMaster. Installation, operating and servicing instructions. HeatMaster 71 HeatMaster 101 HeatMaster 201 ENGLISH FRANCAIS NEDERLANDS ESPAÑOL

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

Gas-fired unit heaters for indoor installation

kw Btu/h Metres Feet l/min. Gal/min C C

MAX O GAZ. Condensing water heater TECHNICAL MANUAL

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

ENERGY TOP. Condensing boiler solutions

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

GB Condensing Gas Boiler

Technical Documentation

INSTALLATION GUIDE, OPERATION AND SERVICE MANUAL

The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

Vaska Logburner. voorbeeld Installation guide

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

Sirius FS. Working towards a cleaner future

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Installation, operating and maintenance instructions

Forced draught gas burner

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

Copper-Fin GAS-FIRED WATER HEATERS

Bosch Group. 15SBi / 24SBi. WALL MOUNTED BOILERS FOR CENTRAL HEATING and Indirect supply of domestic hot water

FERROLI F30 INSTALLATION, SERVICING AND USER INSTRUCTIONS G.C. NO: Appr. nr. B99.06 A - CE 0461 BM /0-07/2001

Commercial Gas Water Heaters

DOMINA 102 COPPER WALL-MOUNTED COMBINATION, GAS FIRED BOILER FOR CENTRAL HEATING

RAYPAK HOT WATER & HEATING

United Kingdom & Ireland

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

RAYPAK HOT WATER & HEATING

Alpha CombiMax 350 and 600

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

940ES Tankless Water Heater

C Tahiti. condensing

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

INSTALLATION - AND USER INSTRUCTIONS

A/23 MFFI - A/27 MFFI

Compact. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

DOMINA 102 DGT INSTALLATION, SERVICING AND USER INSTRUCTIONS G.C. NO: Appr. nr. B99.06 A - CE 0461 AU /1-07/2001

TERMO ELECTRIC BOILERS MANUAL OSO TERMO RS -E OSO TERMO PLUS - E OSO TERMO PTV E

Residential/Commercial Gas Condensing Tankless Models

Performa System 12e, 18e, 24e & 28e

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

EcoSable Gas Fired Condensing Water Heater

Maximiser SE 42 & SE 65

Logamax plus GB172/GB172T. Heat is our element. Technical Guide Issue 2011/06. Fügen Sie auf der Vorgabeseite das zur Produktgruppe passende Bild ein.

GAS FIRED AIR CURTAIN AB 175, AB 225

940ES Tankless Water Heater

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

Condensing, pre-mixed, wall-hung gas boilers with water tank

Transcription:

Condensing Glass-Lined Water Heater BFC - 28/30/50/60/80/100 Meets EPC standards Fully room-sealed condensing high-efficiency water heater (95%gross) Flexible flue options (maximum length 115 m) allows installation almost anywhere ThermoControl for easy flexible control/fault diagnosis Meets latest EPC standards: BFC Cyclone 28-60: 0.902 Utilises premix Low-NOx burner /100 Patented BFC Cyclone burner 28-60 All models suitable for natural or LP gas Programmable for legionella purge cycle Scale formation is reduced through the improved design and location of the heat exchanger BFC Cyclone 80/100: comes as standard with powered anodes to reduce maintenance requirements Remote control connection Voltage-free contact for general fault indication Optional ancillaries: Unvented kits Destratification pump kit Powered anodes Innovation has a name.

Technical specifications Gas data natural gas 2H (G20) Input* kw 32.1 34.5 52.6 63.2 86.6 105.5 Output kw 30.5 32.7 48.8 59.6 81.9 99.8 Inlet pressure mbar 20 20 20 20 20 20 Burner pressure mbar 8.5 8.5 8.5 11.5 7.0 6.0 Gas consumption** m 3 /h 3.1 3.3 5.0 6.0 8.3 10.1 Diameter main orifice mm 4.90 5.10 7.00 7.10 6.30 6.80 Max. flue gas temperature C 70 50 75 75 50 50 Flue gas discharge kg/h 56.8 61.1 85.4 101.4 141.9 164.3 Gas data butane 3+ (G30) Input* kw 30.7 32.8 50.6 59.4 - - Output kw 29.8 31.8 48.1 57.4 - - Inlet pressure mbar 30 30 30 30 - - Burner pressure mbar 30 30 30 30 - - Gas consumption** kg/h 2.2 2.4 3.7 4.3 - - Diameter main orifice mm 2.50 2.60 3.40 3.80 - - Max. flue gas temperature C 70 50 75 75 - - Flue gas discharge kg/h 60.0 62.2 86.0 101.9 - - Gas data propane 3+ (G31) Input* kw 29.0 30.9 50.3 59.1 84.8*** 103.3*** Output kw 28.1 29.8 47.7 56.9 81.9*** 99.8*** Inlet pressure mbar 37 37 37 37 37*** 37*** Burner pressure mbar 37 37 37 37 13.0*** 13.0*** Gas consumption** kg/h 2.1 2.2 3.6 4.2 6.1*** 7.4*** Diameter main orifice mm 2.50 2.60 3.40 3.80 4.70*** 5.10*** Max. flue gas temperature C 70 50 75 75 50*** 50*** Flue gas discharge kg/h 54.3 56.5 85.1 101.0 142.1*** 176.4*** Draw-off capacity Storage capacity l 217 368 368 368 460 460 Max. temperature setting C 80 80 80 80 80 80 T cold = 10ºC / T set = 70ºC 30 min. T=44 C l 505 689 831 925 1222 1379 60 min. T=44 C l 802 1008 1308 1507 2023 2354 90 min. T=44 C l 1100 1327 1785 2089 2823 3329 120 min. T=44 C l 1398 1646 2262 2671 3623 4304 Continuous T=44 C l/h 595 638 954 1164 1601 1950 Heating-up time T=44 C min. 22 35 23 19 17 14 30 min. T=50 C l 444 606 731 814 1076 1214 60 min. T=50 C l 707 887 1151 1326 1780 2072 90 min. T=50 C l 968 1168 1571 1839 2484 2929 120 min. T=50 C l 1230 1449 1991 2351 3189 3787 Continuous T=50 C l/h 524 562 840 1024 1409 1716 Heating-up time T=50 C min. 25 39 26 22 20 16 30 min. T=55 C l 404 551 665 740 978 1109 60 min. T=55 C l 642 806 1046 1206 1618 1883 90 min. T=55 C l 880 1062 1418 1671 2258 2663 120 min. T=55 C l 1118 1317 1810 2137 2899 3443 Continuous T=55 C l/h 476 511 763 931 1281 1560 Heating-up time T=55 C min. 27 43 29 24 22 18 Electrical data Power consumption W 275 275 275 275 625 710 Power supply VAC/Hz 230 (-15/+10%). 50 (+/-1Hz) General Fan rotational speed at ignition r.p.m. 4500 4500 4500 4500 2790 3120 Working speed of fan r.p.m. 5000 5400 6000 6660 5100 5700 Pressure differential Pa 635/605 855/825 885/855 1085/1055 1005/975 1145/1115 Diameter of air restrictor mm 23 23 28 29 36 38 Anodes - 4 4 4 4 2 2 Maximum working pressure bar 8 Shipping data Weight empty kg 177 214 214 214 480 480 Maximum weight kg 394 582 582 582 940 940 Weight incl. packaging kg 197 234 234 234 491 491 Width packaging mm 790 790 790 790 920 920 Height packaging mm 1550 2080 2080 2080 2060 2060 Depth packaging mm 950 950 950 950 1020 1020 *** 3P (G31) * Gas data on gross value ** Gas consumption at 15 C and 1013.25 mbar

Dimensions -60 A 1390 1910 1910 1910 2060 2060 C - - - - 530 530 D 705 705 705 705 850 850 E - - - - 1000 1000 F - - - - 900 900 G 80/125 100/150 100/150 100/150 130/200 130/200 H 1365 1905 1905 1905 2015 2015 Hx 265 265 265 265 310 310 Hy 375 375 375 375 440 440 K 1270 1800 1800 1800 1855 1855 M 170 160 160 160 225 225 N 1390 1910 1910 1910 2060 2060 Ny 205 205 205 205 205 205 P 170 175 175 175 290 290 R 85 75 75 75 225 225 S 900 1410 1410 1410 1425 1425 W 125 145 145 145 240 240 1 Cold water (external) R1 1 /2 2 Hot water (external) R1 1 /2 3 Gas control (internal) Rp 3 /4 4 Tank drain valve (internal) 3 /4 5 T&P valve (internal) 1-11.5 NPT 6 Cleaning and inspection opening 95x70 7 Condensation drainage (internal) Ø40 () Rp 1 (-100) -100 Dimensions in mm. All BFC Cyclone water heaters receive a three years warranty on the tank and one year on parts.

Installation diagrams Vented 1 Pressure reducing valve 3 T&P valve 4 Stop valve 5 Non-return valve 6 Circulation pump 9 Drain valve 10 Gas cock 11 Isolating valve 12 Temperature gauge 13 Condense drain 14 Hot water outlets 15 Expansion relief valve 16 Expansion vessel 17 Three way valve 18 Water tank 19 Float valve A B C D E H Cold water Hot water Return circulation Gas supply Overflow pipe Expansion vent pipe A.O. Smith unvented system kits utilise combination valves. Unvented Further installation and connection details can be found in the Installation & Commissioning Manual.

Electrical diagram -60 TERMINAL STRIP CONNECTIONS Earth N Neutral L1 Phase input of controller L2 Phase input of isolating transformer (primary side) L3 Phase output of isolating transformer (secondary side) L4 Phase input of program-controlled pump L5 Phase input of continuous pump COMPONENTS A Controller B Ionisation rod C Glow igniter D Gas control E Burner earth connection F Extra ON mode switch G Continuous pump H Program-controlled pump J Extra error signal K Isolating transformer L Double-pole mains switch M ON/OFF switch control N Display/Flat cable O Fan P Temperature sensor (T2 - bottom of tank) Q Dummy R Temperature sensor (T1 - top of tank) S Selection resistor T Pressure switch CONTROLLER CONNECTIONS J1 Connector for display to controller J2 Connector for power supply to controller J19 Connector for extra error signal J20 Connector for gas control J21 Connector for programcontrolled pump J24 Connector for fan JP2 Connector for ionisation rod and glow igniter JP3 Connector for temperature sensor T2 JP4 Connector for dummy JP5 Connector for temperature sensor T1 JP6 Connector for selection resistor and pressure switch JP8 Connector for extra ON mode switch F1 F2 Colour cables 1 = brown 2 = blue 3 = yellow/green 4 = black 5 = white (flat cable) 6 = grey/beige BFC Cyclone Electrical diagram -100 TERMINAL STRIP CONNECTIONS Earth N Neutral L Phase input of controller L1 Phase output of isolating transformer ( secundary side) L2 Phase input of isolating transformer ( primary side) L3 Phase input of programcontrolled pump L4 Phase input of frequency controller L5 Phase input of continuous pump COMPONENTS A Controller B Ionisation rod C Glow ignitor D Gas control E Burner earth connection F External ON-mode switch G Program-controlled pump H External error-signal J Isolating transformer K Double-pole mains switch L Controller 0/1 switch M Display/Flat cable N Fan O Temperaturesensor (T2-bottom of tank) P Dummy Q Temperaturesensor (T1-top of tank) R Selection resistor S Pressure switch T Potentiostat U Frequency controller V Argus-link interface W Electric anodes X Signaling for electric anodes Y Mains choke and EMC filter CONTROLLER CONNECTIONS J2 Connector for power supply to controller J19 Connector for external error-signal J20 Connector for gas-control J21 Connector for program controlled pump J36 Connector for display to controller J39 Connector for fan controlled signal JP2 Connector for ionisation rod and glow ignitor JP3 Connector for temperature sensor T2 JP4 Connector for dummy JP5 Connector for temperature sensor T1 JP6 Connector for selection resistor, pressure switch and anode signaling JP8 Connector for extra ON-mode switch F1 F3 Colour cables 1 = brown 2 = blue 3 = yellow/green 4 = black 5 = white (flat cable) 6 = grey/beige 7 = red 8 = green

Flue systems BFC Cyclone Installation options A BFC Cyclone water heater should be installed according category B23, C13, C33, C43 or C53*. C13 B23 Concentric Diameter (mm) 80/125 100/150 100/150 100/150 130/200 130/200 Max. length (m) 40 40 40 15 15 15 Max. 45/90 bends 7 7 7 4 3 3 Parallel (standard diameter) Diameter (mm) 80 100 100 100 130 130 Max. length (m) 25 80 45 25 115 60 L equivalent /bend 90 (m) 3,9 4,6 4,6 4,6 2,4 2,4 L equivalent /bend 45º (m) 1,1 1,2 1,2 1,2 1,4 1,4 C33 Parallel (larger diameter for more length) Diameter (mm) 100 130 130 130 150 150 Max. length (m) 100 100 100 100 100 100 L equivalent /bend 90º (m) 4,6 2,4 2,4 2,4 2,6 2,6 L equivalent /bend 45º (m) 1,2 1,4 1,4 1,4 1,6 1,6 * All BFC Cyclone are also approved for installations where the unit is supplied without venting materials (C63). Concentric flues It is not permitted to use more than the specified number of bends, even when the duct is shorter than the maximum length. A 45 bend is equivalent to a 90 bend. C53 Parallel flues - The maximum permissible length should be reduced by the equivalent length of each bend. (Note: for a parallel installation this means that 3 changes in direction amount to 6 bends (3 in the supply duct and 3 in the flue). - The maximum length also applies if a parallel installation has different supply and flue duct lengths (B23, C53). - Combined flues (C43) shall be fitted with a condensate drain. C43 Note: horizontal flue runs must be installed with a fall of at least 5 mm per metre. Flue systems BFC Cyclone Minimum space requirements -60-100 Ø80/125 Ø100/150 Ø100/150 Ø100/150 Ø130/200 Ø130/200 Minimal space for wall duct (mm) V 550 550 550 550 640 640 W 725 790 790 790 940 940 X 1535 2075 2075 2075 2230 2230 Y 1460 1480 1480 1480 1620 1620 Y * 1010 1030 1030 1030 1170 1170 Minimal space for roof duct (mm) V 1305 1500 1500 1500 1730 1730 W 680 1035 1035 1035 1120 1120 X 2965 3325 3325 3325 3620 3620 X ** 2015 2375 2375 2375 2670 2670 Y 1575 1415 1415 1415 1560 1560 Y ** 625 465 465 465 610 610 For the parts numbers of components and flue gas ducts, etc. please refer to the Maintenance and accessories chapter. * Distance without concentric pipe between bend and wall duct. ** Distance without concentric pipe between appliance and roof duct. Data subject to change UK/0109/BFC/01 Terms and conditions apply, please refer to our website Water Heaters A.O. Smith Water Heaters, Unit B8 Armstrong Mall, Southwood Business Park, Farnborough, Hampshire, GU 14 ONR www.aosmith.co.uk A.O. Smith Water Heaters is a trading name of Advance Services (Sales) Ltd. Reg.