standard response fusible link sidewall sprinkler VK112 (K5.6)

Similar documents
Microfast quick response Fusible element hsw sprinkler

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

micromatic Standard response Horizontal Sidewall sprinkler

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

standard response Fusible Link Upright sprinkler VK204 (K8.0)

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

micromatic Standard response Horizontal Sidewall sprinkler

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

MicrofastHP QUICK RESPONSE HORIZONTAL SIDEWALL HIGH PRESSURE SPRINKLER VK319 (K5.6) TECHNICAL DATA

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

MICROMATIC STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6) TECHNICAL DATA

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

TECHNICAL DATA. Page 1 of 6

microfast quick response extended coverage hsw sprinkler vk606

MICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

microfast sr/qr extended coverage pendent sprinkler

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

quick response horizontal sidewall sprinkler vk360 (K8.0)

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

microfast quick response Pendent sprinkler VK302 (K5.6)

micromatic standard response Upright sprinkler VK100 (K5.6)

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK118 (K5.6) TECHNICAL DATA

MICROMATIC STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK120 (K8.0) TECHNICAL DATA

STANDARD/quick. Sprinkler 42o. August 8, 2011

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

micromatic standard response stainless steel sprinklers

standard response elo upright sprinkler

standard response elo upright and pendent sprinklers (storage-density/area)

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

standard response dry horizontal sidewall sprinklers

standard response dry horizontal sidewall sprinklers

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

standard/quick response extended coverage light and ordinary hazard elo sprinklers

VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

standard response dry horizontal sidewall sprinklers

microfast and microfasthp quick conventional sprinklers

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart.

Standard Spray concealed horizontal sidewall sprinkler VK481

freedom residential horizontal sidewall lead free sprinkler VK4840 (k4.2)

quick response Sprinkler 105a October 25, 2010

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

standard response large orifice dry

standard response/ quick response extended coverage

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

TECHNICAL DATA. Page 1 of 5

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK460 (K5.8) TECHNICAL DATA

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK534 (K11.2)

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

DRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

Quick response concealed horizontal sidewall sprinkler VK481

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

TECHNICAL DATA vk470 (K3.0)

TECHNICAL DATA. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. Sprinkler 103a.

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

freedom residential pendent sprinkler vk466 (K5.2)

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

freedom residential horizontal sidewall sprinkler Vk450 (k4.2)

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) TECHNICAL DATA

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

Transcription:

Page 1 of 6 1. DESCRIPTION Viking Standard Response Fusible Link Sidewall Sprinkler VK112 is a small thermosensitive solder link spray sprinkler. The horizontal sidewall sprinkler VK112 is available with finishes and temperature ratings to meet design requirements. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2012 Refer to Approval Chart 1 and Design Criteria for culus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Nominal K-Factor: 5.6 U.S. (80.6 metric*) * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. Overall Length: Refer to the Approval Charts Material Standards: Frame Casting: Brass UNS-C84400 HSW Deflector: Copper UNS-C19500 Fusible Link Assembly: Brass UNS- C40500 and UNS-C51000 For chrome sprinklers, the fusible link assembly is painted silver for decorative purposes only. Bushing: Brass UNS-C36000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Stainless Steel UNS-S30300 Pip Cap: Copper UNS-C11000 Pip Cap Attachment: Brass UNS-C36000 Button: Copper UNS-C19400 Ordering Information: (Also refer to the current Viking price list.) Order Viking Standard Response Fusible Link Sidewall Sprinkler VK112 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F Temperature Suffix: 165 F (74 C) = C, 220 F (104 C) = F, and 286 F (141 C) = G For example, sprinkler VK112 with a Brass finish and a 165 F (74 C) temperature rating = Part No. 12974AC Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: A. Standard Wrench: Part No. 21475M/B (available since 2017). B. Wrench for recessed and/or wax coated sprinklers: Part No. 13577W/B** (available since 2006) **A ½ ratchet is required (not available from Viking). Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. Installation Refer to appropriate NFPA Installation Standards. For Light Hazard Occupancies Only Replaces Form No. F_060404 Rev 14.2 (Replaced wrench 10896W/B with 21475M/B)

Page 2 of 6 5. Operation During fire conditions, the heat-sensitive fusible link disengages, the pip cap and spring are released, and the waterway is opened. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. inspections, tests and maintenance Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. availability Viking Standard Response Fusible Link Sidewall Sprinkler VK112 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. Guarantee For details of warranty, refer to Viking s current list price schedule or contact Viking directly. Wrench Flat Figure 1: Standard Sprinkler Wrench 21475M/B

Page 3 of 6 Sprinkler Temperature Classification TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Nominal Temperature Rating 1 Maximum Ambient Ceiling Temperature 2 Frame Paint Color Ordinary 165 F (74 C) 100 F (38 C) None Intermediate 220 F (104 C) 150 F (65 C) White High 286 F (141 C) 225 F (107 C) Blue Sprinkler Finishes: Brass and Chrome Footnotes 1 Decorative sprinklers may not be color coded. The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Step 1: Carefully slide the wrench sideways around the deflector, ensuring engagement with the sprinklger wrench flats. Sprinkler wrench 13577W/B** must be used for installing recessed sprinklers. ** A 1/2 ratchet is required (not available from Viking) Step 2: Carefully press the wrench onto the sprinkler wrench flats. Figure 2: Wrench 13577W/B for Recessed Sprinklers

Page 4 of 6 Base Part Number 1 SIN Sprinkler Style Approval Chart 1 (UL) Standard Response Fusible Link Sidewall Sprinkler VK112 For Light Hazard Occupancies Only Maximum 175 PSI (12 Bar) WWP Thread Size Nominal K-Factor Overall Length culus Listings 3,4 (Refer also to Design Criteria below.) NPT BSP U.S. metric 2 Inches mm culus 5 NYC VdS LPCB 12974 VK112 HSW 1/2 15 mm 5.6 80.6 2-9/16 64 B1X 6, A1Y 7 -- -- -- -- -- NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 05559 VK112 HSW 1/2 15 mm 5.6 80.6 2-1/2 64 B1X 6, A1Y 7 -- -- -- -- -- Approved Temperature Ratings A - 165 F (74 C), 220 F (104 C), and 286 F (141 C) B - 165 F (74 C) and 220 F (104 C) Approved Finishes 1 - Brass and Chrome Approved Escutcheons X - Installed with standard surface-mounted escutcheons, the Viking Microfast Model F-1 Adjustable Escutcheon, or recessed with the Viking Micromatic Model E-1 or E-2 Recessed Escutcheon Y - Installed with standard surface-mounted escutcheons or the Viking Microfast Model F-1 Adjustable Escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 4 Listings are limited to Light Hazard Occupancies where allowed by the installation standards being applied. 5 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 6 culus Listed with the deflector located 4 to 6 (102 mm to 152 mm) below the ceiling. 7 culus Listed with the deflector located 4 to 12 (102 mm to 304 mm) below the ceiling. culus Listing Requirements: DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) Viking Standard Response Fusible Link Sidewall Sprinkler VK112 are culus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for sidewall standard spray sprinklers. For use in Light Hazard occupancies only where allowed by the installation standards being applied. Refer to the Approval Chart for allowable deflector distance below the ceiling. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Minimum spacing allowed is 6 ft. (1.8 m). Align the top of the deflector parallel with the ceiling. Locate no less than 4 (102 mm) from end walls. Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable.

Page 5 of 6 Approval Chart 2 (FM) Standard Response Fusible Link Sidewall Sprinkler VK112 Maximum 175 PSI (12 Bar) WWP Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals SIN 3 Number 1 Style NPT BSP U.S. metric 2 Inches mm (Refer also to Design Criteria below.) 12974 VK112 HSW 1/2 15 mm 5.6 80.6 2-9/16 64 A1X, B1Y NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 05559 VK112 HSW 1/2 15 mm 5.6 80.6 2-1/2 64 A1X, B1Y Approved Temperature Ratings A - 165 F (74 C), 220 F (104 C), and 286 F (141 C) B - 165 F (74 C) and 220 F (104 C) Approved Finish 1 - Brass Approved Escutcheons X - Installed with standard surface-mounted escutcheons or the Viking Microfast Model F-1 Adjustable Escutcheon Y - Installed with the Viking Model G-1 Recessed Escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Other approvals may be in process. FM Approval Requirements: DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) Sprinkler VK112 is FM Approved as a Non-Storage horizontal sidewall sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from culus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable.

Page 6 of 6 2-1/2 (64 mm) 2-1/4 (58 mm) Minimum 1-7/8 (48 mm) 2-1/8 (54 mm) 1-7/8 (48 mm) Maximum Wall Opening Size: 2-5/16 (59 mm) minimum 2-1/2 (64 mm) maximum Installed with a standard 1/8 surface-mounted escutcheon Installed with a Microfast Model F-1 Adjustable Escutcheon Figure 3: Sidewall Sprinkler Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Minimum 1-7/16 (37 mm) Minimum 1-7/16 (37 mm) 2-1/8 (54 mm) 2-1/8 (54 mm) 2-1/16 (52 mm) Maximum 2-1/4 (57 mm) Maximum Wall Opening Size: 2-5/16 (59 mm) minimum 2-1/2 (64 mm) maximum Installed with the Micromatic Model E-1 Recessed Escutcheon Installed with the Threaded Model E-2 Recessed Escutcheon Figure 4: Sidewall Sprinkler VK112 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Replaces Form No. F_060404 Rev 14.2 (Replaced wrench 10896W/B with 21475M/B)