Installation & Operation Manual

Similar documents
- Data Brochure. This brochure is for Thermostats 510 and 511 (with sensor). The section on the 079 slab sensor installation is for the 511 only!

Installation & Operation Manual

- User Brochure tekmarnet 4 Setpoint Control 161

Installation & Operation Manual

- User Brochure Programmable Thermostat 510

Quick Set-up Guide. 1. Location 2. Remove Mounting Base. 4. Switch Settings. 3. Install Mounting Base. 5. Wiring. Snow Melting Control PM-653

Radiant Thermostat 519

- Data Brochure Mixing Reset Module 421

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

OPERATION, SERVICE & PARTS MANUAL

FLCH4R Garage and Utility Electric Heater

Light Construction Equipment Consumer Warranty Policy

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

Easy installation in both new construction and retrofit

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

Easy installation in both new construction and retrofit

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

INSTRUCTION MANUAL HS-229G

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

Figure 1. Figure 2. See notes 1 and 2 below.

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Full Extension Soft-Close Undermount Drawer Slide

Compact Equipment Warranty Policy

OPERATION, SERVICE & PARTS MANUAL

Installation Guide

Here is what comes in your box:

Instruction Manual: IM E. Installation and Operation Manual for Powerware PVL 50, 80, 100, 120, 160, 200 KA

View the expanded manual: GEN5

OPERATION & INSTALLATION MANUAL

MN908 No. 282C Replaces 282B LB7013

Environmental Monitoring SmartSlot Card

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

installation, operation & Maintenance manual Floor-mounted Induction units

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

Duct Mount. Installation Instructions

Ultrasonic Reflective Sensor

Patent Pending invent for New Construction

ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor

FW-RA-LED Remote Multiplex Annunciator Panels

Corrosion Resistant Fluid and Air Handling Systems.

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

INSTALLATION MANUAL VISUAL PERFORMANCE RECTANGLE SPEAKERS. Introduction. Box Contents. Speaker Placement. Surround Speakers (5.

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

MaxLite LED MICRO-T PANEL

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

Service & Parts Manual

To get started, please read and follow all instructions for usage and maintenance carefully before operating the VACMASTER BS116 Impulse Bag Sealer.

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

Humidity Monitor model 01080

Model NT20e Installation Guide

Room Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

Thermometer with Wired Sensor

XT Series Thermostats

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

Paralda Air Purifier USER MANUAL

- Application Boiler Control 260

Long Range Radio Alarm Transmitter

DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS

MaxLite LED High Bay Fixtures

Thermometer with Probe model 00891A

ion Genesis Pump Controller

Installation & Operation Manual for WarmlyYours Towel Warmers

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Fan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

CD6102 / CD6102 OC / CD6102-2

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

installation, operation & Maintenance manual acb ceiling-mounted cassette models

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

HTLS. Heat Tracing Line Sensing Control Panel

- Data Brochure D 261. Boiler Control 261

Installation and Servicing Instructions

Blade Series Heat Exchanger Operation and Installation

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Installation & Operation Manual for WarmlyYours Towel Warmers

SACKSAFOAM QUICK FILL OPERATIONS MANUAL 2019A

Wax Base Heater & Dispenser

Air Pump Up to 800 gallons

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

INSTALLATION AND OPERATING MANUAL

CO2 Sensor User and Installation Guide

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

Proliphix Thermostat Installation Guide. Release 2.0

FloorHeat Installation Manual

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

Thermometer model 02059

* These Remote Mics must be SPRM-GP

TrueClean ToteCleaner

IMPORTANT. 3-in-1 Weather Sensor model SAVE THIS MANUAL FOR FUTURE REFERENCE. Package Contents

Please read and follow all instructions for usage and maintenance before operating the VACMASTER SV1 Immersion Circulator.

Transcription:

Humidity & Temperature Sensor 086 Accessories 086_D 08/12 Replaces: New Installation & Operation Manual Introduction The Humidity & Temperature Sensor 086 can be connected to select tekmar thermostats to remotely measure relative humidity and temperature. The 086 mounts flush or nearly flush to the wall to allow the sensor to visually blend in with the surrounding wall. Actual Size 1 of 8

Installation Caution Improper installation and operation of this control could result in damage to the equipment and possibly even personal injury or death. It is your responsibility to ensure that this control is safely installed according to all applicable codes and standards. Please follow these step-by-step instructions to gain a full understanding of this device. Step One - Check the Contents Check the contents of this package. If any of the contents listed are missing or damaged, please refer to the Limited Warranty and Product Return Procedure on the back of this brochure and contact your wholesaler or tekmar sales representative for assistance. Type 086 includes One Indoor Sensor 086 One Installation and Operation Manual D 086. Step Two - Choosing a Location for the Sensor The sensor should be installed on an interior wall of the desired zone to be controlled. Avoid installing the sensor in a wall if the adjacent zone is at a much different temperature. Do not mount the sensor in a location that may be affected by localized heat sources or cold drafts (in direct sunlight or near a supply air duct or window). Step Three - Rough In Wiring Before drywall is installed run four conductor 18 AWG wire from the tekmar thermostat to the desired location of the sensor. The maximum wire length between a thermostat and sensor is 500 (152.4 m). Do not run the wires parallel to telephone or power lines. If the sensor wires are located in an area with strong sources of electromagnetic noise, shielded cable or twisted pair should be used or the wires can be run in a grounded metal conduit. If using shielded cable, one end of the shield wire should be connected to the Com terminal on the thermostat and the other end should remain free. The shield must not be connected to earth ground. Staple the wire to a wall stud 5 (1.5 m) above the floor and coil 1 (0.3 m) of the wire to work with before cutting it off. Write down the exact location of the wire in the wall so it can be found when the drywall is installed. 2 of 8

Step Four - Installing the Sensor Once the drywall has been installed, locate the sensor wire behind the drywall using your notes from Step Three. Near Flush Mount ---------------------------------------------------- A. Using a hole-saw to drill a 1 (25.5 mm) hole at the location of the sensor wire. Do not drill hole directly over stud. B. Paint the wall. C. Remove front disc sticker from the sensor. D. The front disc of the sensor may be carefully hand painted. The slotted grill holes must be kept open and free of paint. Do not use a paint roller. Avoid allowing paint to enter the slotted holes on the front disc of the sensor as permanent damage to the sensor may result. E. Pull the excess wire through the hole. F. Follow the directions in Step Five - Wiring the Sensor. G. Once wired, feed the excess wire back into the hole and hand press the sensor until the back of the disk touches the wall. The sensor is held in place by the taper of the enclosure (no fasteners required). Hole Saw 1 (25.5 mm) 1 (25.5 mm) Photo of actual 086 near flush mount installed 3 of 8

True Flush Mount ---------------------------------------------------- A. Use a 1-1/2 (38.0 mm) spade bit to drill a recess hole lightly into Spade Bit the drywall to a depth no more than 1/8 (3.0 mm). B. Use a 1 (25.5 mm) hole-saw and place the guide bit into the center hole created by the spade bit and drill through the drywall. C. Sand the surface of the drywall around the hole to remove the raised paper edge from drilling. D. Pull the excess wire through the hole. E. Follow the directions in Step Five - Wiring the Sensor. F. Use a straight edge (a square or a level) to push the sensor flush with the surface of the drywall. Press 2 to 3 times in each direction (90 deg and 0 deg) repeatedly until flush. Do not attempt to press it in in one motion as the sensor may tilt. The sensor is held in place by the taper of the enclosure (no fasteners required). Leave the front disc sticker in place. G. Use a mud trowel to mud over the entire sensor. 1-1/2 H. Once mud dries, sand the surface of the sensor until the entire (38.0 mm) front disc sticker is completely visible. This ensures the shallowest circular mark. I. Remove front disc sticker. J. Paint the wall including the sensor using a paint roller. The slotted grill holes must be kept open and free of paint. This can be achieved by using the paint roller that is mostly wrung out of paint. Hole Saw 1-1/2 (38.0 mm) 1 (25.5 mm) 1 (25.5 mm) 1/8 (3.0 mm) Photo of actual 086 flush mount installed 4 of 8

Step Five - Wiring the Sensor The sensor has four wiring terminals that connect to a humidity sensing thermostat. 1. Connect the Sen terminal to the thermostat temperature sensor terminal (typically auxiliary sensor 2). 2. Connect the Com terminal to the thermostat sensor common terminal. 3. Connect the %RH terminal to the thermostat humidity sensor terminal (typically auxiliary sensor 3). 3. Connect the +V terminal to the thermostat 0-10 Vdc terminal. Sen Com %RH +V tekmarnet Thermostat 557 Com S2 S3 0-10 Vdc Humidity & Temperature Sensor 086 Temperature Sensor Testing Instructions A good quality test meter capable of measuring up to 5,000 kω (1 kω = 1000Ω) is required to measure the sensor resistance. In addition to this, the actual temperature must be measured with either a good quality digital thermometer, or if a thermometer is not available, a second sensor can be placed alongside the one to be tested and the readings compared. First measure the room temperature using the thermometer. Disconnect the Sen and Com wires from the thermostat. Using an electrical meter, measure the resistance of the Sen and Com wires at the thermostat location. Using the temperature versus resistance table, estimate the temperature measured by the sensor. The sensor measurement and thermometer readings should be close. If the test meter reads a very high resistance, there may be a broken wire, a poor wiring connection or a defective sensor. If the resistance is very low, the wiring may be shorted, there may be moisture in the sensor or the sensor may be defective. To test for a defective sensor, measure the resistance directly at the sensor location. Once the test has been completed, reconnect the Sen and Com wires to the thermostat. Do not apply voltage to the temperature sensor terminals at any time as damage to the sensor may result. 5 of 8

Temperature vs. Resistance Table Temperature Resistance F C -50-46 490,813-45 -43 405,710-40 -40 336,606-35 -37 280,279-30 -34 234,196-25 -32 196,358-20 -29 165,180-15 -26 139,402-10 -23 118,018-5 -21 100,221 0-18 85,362 5-15 72,918 10-12 62,465 15-9 53,658 20-7 46,218 25-4 39,913 30-1 34,558 35 2 29,996 40 4 26,099 45 7 22,763 50 10 19,900 55 13 17,436 60 16 15,311 65 18 13,474 70 21 11,883 75 24 10,501 80 27 9,299 85 29 8,250 Temperature Resistance F C 90 32 7,334 95 35 6,532 100 38 5,828 105 41 5,210 110 43 4,665 115 46 4,184 120 49 3,760 125 52 3,383 130 54 3,050 135 57 2,754 140 60 2,490 145 63 2,255 150 66 2,045 155 68 1,857 160 71 1,689 165 74 1,538 170 77 1,403 175 79 1,281 180 82 1,172 185 85 1,073 190 88 983 195 91 903 200 93 829 205 96 763 210 99 703 215 102 648 220 104 598 225 107 553 6 of 8

Humidity Sensor Testing Instructions Setup the thermostat to disable the built-in humidity sensor and measure only the external humidity sensor. The thermostat should be powered for 15 minutes prior to testing. Record the external relative humidity reading. Use an electrical meter and set to V (dc). Measure the voltage between the +V and Com wires. It should measure 3.3 V (dc). If the voltage is different, the thermostat power supply may be faulty. Next, measure the voltage between the %RH and Com wiring terminals from the thermostat location. Using the humidity versus voltage table, estimate the measured relative humidity level in the room. If the displayed relative humidity on the thermostat and the measured relative humidity are similar the sensor is working correctly. If the displayed relative humidity on the thermostat is significantly different than the measured relative humidity, the sensor may require replacement. Humidity vs. Voltage Table RH Voltage (%RH to Com) RH Voltage (%RH to Com) 5 0.59 55 1.61 10 0.69 60 1.72 15 0.79 65 1.82 20 0.90 70 1.92 25 1.00 75 2.03 30 1.10 80 2.13 35 1.20 85 2.23 40 1.31 90 2.33 45 1.41 95 2.44 50 1.51 100 2.54 Technical Data Humidity & Temperature Sensor 086; Flush Mount Literature 086_C, 086_D Packaged weight 0.13 lbs (60 g) Enclosure White PC-ABS plastic, NEMA 1 Dimensions 1-7/16 O.D. x 1-9/16 D (36 O.D. x 40 mm) Ambient conditions Indoor use only, 15 to 140 F (-10 to 60 C), non-condensing Compatible with chlorinated swimming pool environments. Environmental Do not use in presence of ammonia (animal barns), methanol, ethanol, acetone. Power supply 2.7 to 5.5 V (dc), 0.5 ma maximum, 65 kω min impedance Humidity sensor 0 to 90% ± 3% RH Temperature sensor NTC thermistor, 10 kω @ 77 F (25 C ±0.2 C) β = 3892 7 of 8

Limited Warranty and Product Return Procedure Limited Warranty The liability of tekmar under this warranty is limited. The Purchaser, by taking receipt of any tekmar product ( Product ), acknowledges the terms of the Limited Warranty in effect at the time of such Product sale and acknowledges that it has read and understands same. The tekmar Limited Warranty to the Purchaser on the Products sold hereunder is a manufacturer s passthrough warranty which the Purchaser is authorized to pass through to its customers. Under the Limited Warranty, each tekmar Product is warranted against defects in workmanship and materials if the Product is installed and used in compliance with tekmar s instructions, ordinary wear and tear excepted. The passthrough warranty period is for a period of twenty-four (24) months from the production date if the Product is not installed during that period, or twelve (12) months from the documented date of installation if installed within twenty-four (24) months from the production date. The liability of tekmar under the Limited Warranty shall be limited to, at tekmar s sole discretion: the cost of parts and labor provided by tekmar to repair defects in materials and / or workmanship of the defective product; or to the exchange of the defective product for a warranty replacement product; or to the granting of credit limited to the original cost of the defective product, and such repair, exchange or credit shall be the sole remedy available from tekmar, and, without limiting the foregoing in any way, tekmar is not responsible, in contract, tort or strict product liability, for any other losses, costs, expenses, inconveniences, or damages, whether direct, indirect, special, secondary, incidental or consequential, arising from ownership or use of the product, or from defects in workmanship or materials, including any liability for fundamental breach of contract. The pass-through Limited Warranty applies only to those defective Products returned to tekmar during the warranty period. This Limited Warranty does not cover the cost of the parts or labor to remove or transport the defective Product, or to reinstall the repaired or replacement Product, all such costs and expenses being subject to Purchaser s agreement and warranty with its customers. Any representations or warranties about the Products made by Purchaser to its customers which are different from or in excess of the tekmar Limited Warranty are the Purchaser s sole responsibility and obligation. Purchaser shall indemnify and hold tekmar harmless from and against any and all claims, liabilities and damages of any kind or nature which arise out of or are related to any such representations or warranties by Purchaser to its customers. The pass-through Limited Warranty does not apply if the returned Product has been damaged by negligence by persons other than tekmar, accident, fire, Act of God, abuse or misuse; or has been damaged by modifications, alterations or attachments made subsequent to purchase which have not been authorized by tekmar; or if the Product was not installed in compliance with tekmar s instructions and / or the local codes and ordinances; or if due to defective installation of the Product; or if the Product was not used in compliance with tekmar s instructions. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, WHICH THE GOVERNING LAW ALLOWS PARTIES TO CONTRACTUALLY EXCLUDE, INCLUDING, WITHOUT LIMITATION, IMPLIED WAR- RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, DURABILITY OR DESCRIP- TION OF THE PRODUCT, ITS NON-INFRINGEMENT OF ANY RELEVANT PATENTS OR TRADEMARKS, AND ITS COMPLIANCE WITH OR NON-VIOLATION OF ANY APPLICABLE ENVIRONMENTAL, HEALTH OR SAFETY LEGISLATION; THE TERM OF ANY OTHER WARRANTY NOT HEREBY CONTRACTUALLY EXCLUDED IS LIM- ITED SUCH THAT IT SHALL NOT EXTEND BEYOND TWENTY-FOUR (24) MONTHS FROM THE PRODUCTION DATE, TO THE EXTENT THAT SUCH LIMITATION IS ALLOWED BY THE GOVERNING LAW. Product Warranty Return Procedure All Products that are believed to have defects in workmanship or materials must be returned, together with a written description of the defect, to the tekmar Representative assigned to the territory in which such Product is located. If tekmar receives an inquiry from someone other than a tekmar Representative, including an inquiry from Purchaser (if not a tekmar Representative) or Purchaser s customers, regarding a potential warranty claim, tekmar s sole obligation shall be to provide the address and other contact information regarding the appropriate Representative. Product design, software and literature are Copyright 2012 by tekmar Control Systems Ltd.,. Head Offi ce: 5100 Silver Star Road, Vernon, B.C. Canada V1B 3K4, 250-545-7749, Fax. 250-545-0650 Web Site: www.tekmarcontrols.com All specifications are subject to change without notice 8 of 8 086_D - 08/12.