EXPERIMENTAL INVESTIGATION OF A REFRIGERATOR BY USING ALTERNATIVE ECO FRIENDLY REFRIGERANTS (R600A & HC MIXTURE)

Similar documents
Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

DEEPAK PALIWAL, S.P.S.RAJPUT

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Experimental study of R600a and R436a to replace R134a in a domestic refrigerator and freezer

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Design of LPG Refrigeration System

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

CHAPTER 1 INTRODUCTION

Comparative Performance Analysis of Domestic Refrigerator using R12, R134a and R600a Refrigerants

International Journal of Multidisciplinary Research and Modern Education (IJMRME) ISSN (Online): (

Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

CHAPTER 1 INTRODUCTION

Department of MCE, Islamic University of Technology 2. Abstract

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

A Comparison Between Refrigerants Used In Air Conditioning

Oyelami S., Bolaji B. O.

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

η second law = Second law efficiency

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

Experimental Investigation on R 290 and R 600a In a Vapor Compression Refrigeration

A Review Paper on Comparative Study of Household- Refrigerator with Alternative Low Global Warming Potential Refrigerants

Theoretical performance evaluation of R134a and its low GWP Hydrocarbon alternatives in Domestic Refrigerator

Assessment of LPG as a possible alternative to R-12 in domestic refrigerators

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

ISSN Electronic International Interdisciplinary Research Journal (EIIRJ) Bi-monthly Reviewed Journal Mar- April 2015

Design and Fabrication of Liquefied Petroleum Gas Refrigeration System and Comparison with Domestic Refrigerator

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Thermodynamics I. Refrigeration and Heat Pump Cycles

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

PERFORMANCE OF REFRIGERATOR USING R-600A AS REFRIGERANT

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

International Engineering Research Journal (IERJ) Special Issue Page , June 2016, ISSN

Chapter 2. Alternatives to HCFCs and their Characteristics

LPG Refrigerator. October 2017 IJIRT Volume 4 Issue 5 ISSN:

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

JJMIE Jordan Journal of Mechanical and Industrial Engineering

ENHANCEMENT OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING NANOFLUIDS

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

Performance Study of Geotropic Blends of Isobutane R600a and Propane R290 in Domestic Refrigerator as Alternative Refrigerants to R134a

Experimental investigation on the performance of air conditioner using R32 Refrigerant

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

International Journal of Advance Engineering and Research Development

CH2351 Chemical Engineering Thermodynamics II Unit V Refrigeration. Dr. M. Subramanian

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

Refrigerants Retrofit as Alternative for R12 and R134a in Household Refrigerators

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

A Review on selecting an Eco-friendly Refrigerant alternate to R134a in Domestic Refrigerators

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Experimental Investigation of COP Using Hydro Carbon Refrigerant in a Domestic Refrigerator

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

ISSN: [Sachuthananthan * et al., 5(10): October, 2016] Impact Factor: 4.116

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

The Problem of Counterfeit Refrigerants

Enhancement of COP using Nanoadditives in Domestic Refrigerator

STUDY AND PERFORMANCE ANALYSIS OF ECO-FRIENDLY REFRIGERANT FOR RETROFITTING R22 IN RESPECT TO BANGLADESH

Sarthak Thakar, 2 R.P.Prajapati 1

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

Technology Application of Environmental Friendly Refrigeration (Green Refrigeration) on Cold Storage for Fishery Industry

Performance and Analytical Study of Cooler Cum Air Conditioner based on Vapour Compression Refrigeration System

Chapter 10. Refrigeration and Heat Pump Systems

Optimization of Capillary Tube Parameters in Vapour Compression System using Environmentally Friendly Refrigerant R1234yf

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

FABRICATION OF REFRIGERANT FLOW RATE WITH SPIRALLY COILED CAPILLARY TUBE

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Keywords: Climate change; ozone depletion; Montreal protocol; eco-friendly refrigerant; hydrocarbon refrigerant; performance analysis.

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

HFCs or the Old Refrigerants - what is the best Choice?

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Experimental performance evaluation of heat pump by using CO 2. as a refrigerant. IOP Conference Series: Materials Science and Engineering

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Volume 2, Issue 1 (2014) ISSN International Journal of Advance Research and Innovation

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Performance Evaluation of Vapour Compression System with R22 and Environment-Friendly Refrigerant

Transcription:

October 217, Volume 4, Issue 1 EXPERIMENTAL INVESTIGATION OF A REFRIGERATOR BY USING ALTERNATIVE ECO FRIENDLY REFRIGERANTS (R6A & HC MIXTURE) 1 NULAKA RAJESWARI, 2 Dr. B.OMPRAKASH, 3 Dr. R.GANAPATHI, 1 M.Tech, Mechanical Engineering, JNTUA College of Engineering Ananthapuramu, A.P, India 2 Asst.Professor, Mechanical Engineering, JNTUA College of Engineering Ananthapuramu, A.P, India 3 Professor, Mechanical Engineering, Anurag Engineering College Kodada, TS, India ABSTRACT: In the present days refrigeration became a common human need but due to the release of green house gases from the refrigerators in to the earth s atmosphere, causes high global warming and in turn destructing the ozone layer of atmosphere. In concern of the earth s environment, Montreal and Kyoto protocols proposed for alternative eco-friendly refrigerants. In the current work, experimental investigation on VCRS system tested with R6a and hydrocarbon mixture (R29/R6a) as refrigerants as they have zero ODP and very low GWP related to the refrigerant R134a. Due to the higher value of latent heat of hydrocarbons, the amount of refrigerant charge will be relatively lower than R134a. By using R6a and hydrocarbon mixture refrigerants of charges 5g, 55g and 6 g are tested individually for performance characteristics and critical correlations are drawn between the refrigerants and represented by graphical representation. Refrigeration effect of R29/R6a (5/5 by wt %) mixture was 21.4% higher than R6a for 55g charge. The obtained results proved that the overall performance of 55g (R29/R6a) mixture could be considered as the best eco-friendly alternative refrigerant phase out R134a refrigerant. Keywords: Eco-friendly refrigerants-r6a(isobutane), Hydrocarbon mixture (R29/Ra), 5g, 55g,6g, of refrigerant charge, performance. I.INTRODUCTION In late 18s and in early 19s, the most used refrigerants were natural refrigerants such as carbon dioxide, ammonia, Sulphurdioxide, and methyl chloride. But due to their toxic or hazardous nature, a safer class of alternative refrigerants came on stage with the invention of CFCs and HCFCs. In 193s, CFCs and HCFCs have been accustomed in domestic refrigerators as refrigerants due to their suitable properties such as stability, non-flammability, non-toxicity, eminent thermodynamic properties,which led to their common wide spread use by both consumers and industries across the globe, exclusively as refrigerants in refrigeration and air-conditioning systems. However, many researchers found that Ozone layer is being depleted due to the presence of chlorine in the stratosphere. The general agreement for this cause is that CFCs and HCFCs are sound class of chlorine containing refrigerants, which disperse to the stratosphere where ozone reacts with them. Later, Chlorine atoms continue to convert more ozone to oxygen. There by depleting the ozone layer of earth, which shields the earth s atmospheric surface from UV radiations? This ozone layer depletion threatens earth s environment that the CFCs and HCFCs have significantly contributed to the global warming problem, as its global warming Potential (GWP) of CFCs is 85 for over 1 years.this resulted in a series of international treaties such as MONTREAL protocol to phase out of CFCs and HCFCs by 1996 and KYOTO protocol, even new developed HFC refrigerants like R-134a should be gradually phased out on or before 23, due to their high GWP and the concentration of green house gases in the atmosphere. Subsequently it was decided to decrease global warming by subjection of green house gases emissivity. Hence to counter balance the global ecological goals, conventional refrigerants should be replaced by environmentally suitable alternative refrigerants for HFCs such as hydrocarbon (HC) R6a and mixtures of HCs R29/R6a.these natural refrigerants are considerably cheaper than their significant alternatives. II. SELECTION OF REFRIGERANT To substitute fully halogenated CFC refrigerants, Hydrocarbons (HCs) and Hydro Fluoro Carbons (HFCs) provide a best alternatives as they contain no chlorine atom at all, therefore have zero ODP. Even, hydro-chlorofluorocarbons (HCFCs) like R22 and R123 which do have chlorine atom, but in association with Hydrogen (H)-atoms, have much reduced ODP. The association of one or more Hydrogen -atom allows them to dissociate faster in the lower atmosphere of the earth surface. Thus, released Chlorine gets absorbed by rain water like the chlorine used in the chlorination of water. So fewer chlorine atoms reach the ozone layer in the upper atmosphere. However, HCFCs have a certain level of ODP in addition to GWP. Hence, these also have to be phased out ultimately. The HFCs on the other hand, because of their H-content may be flammable to some extent. If the molecule is rich in H atoms, then the degree of flammability is high. Pure HCs are highly flammable due to the presence of H-atoms. We know that Normal Boiling Point (N.B.P.) is the single most important characteristic of a substance to be used as a refrigerant. It also governs the equipment, type of application and the refrigerating capacity for which a particular refrigerant is to be used. From this point of view, substances with their N.B.P.s in the range of -5 C to +5 C are considered suitable for use as refrigerants. On the basis of N.B.P.s it has been observed HFC s R134a are potential alternatives to R12, HCs mixture R6a /R29 can also be used in place of R12. Isobutene R6 a is the most used hydrocarbon refrigerant in domestic refrigerators. In 21 st century, the use of isobutene and its mixtures was about 34% in domestic refrigerators and freezer at global level. Thus, HCs like R6 a and its mixture like R29/R6 a are widely uses in air conditioners, heat pumps, and commercial refrigeration systems. JETIR17144 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 278

October 217, Volume 4, Issue 1 Table 1 Properties of possible refrigerant substitutes Refrigerant Formula Molecular weight(kg/kmol) lower flammability limit safety group R134 a CH 2 FCF 3 12. Non flammability R6a C 4 H 1 / isobutene ODP GWP (1 yr) A 1 13 58.1 1.8 A 3 <2 R29 C 3 H 8 44. 2.3 A 3 <2 R436a C 3 H 8 +C 4 H 1 / 49.3 3.7 A 3 3 isobutene III.EXPERIMENTAL SET UP A Domestic Refrigerator of capacity 165 liters is selected. As shown in the Fig.1, it consists of hermitically sealed compressor to discharge the refrigerant at high pressure, air cooled condenser acts as heat exchanger in which both liquid and vapor phases of refrigerant takes place at constant pressure conditions, a capillary tube as expansion valve to expand the refrigerant, and evaporator with copper tubing in which the latent heat of refrigerant gets absorbed and cooling takes place. Temperature and pressure readings are taken from the digital thermocouples and pressure gauges which are arranged at the inlets and outlets of compressor, condenser and evaporators respectively. Energy meter was setup to take the energy consumption readings during the process of the cycle. Figure.1 schematic diagram of VCRS system Before charging the refrigerant in to the compressor, we need to evacuate the cycle because any presence of air or non-condensable gases in the refrigerant may cause a reduction in cooling capacity of the system and a rise in power input due to high discharge pressure. In such cases, oxygen or air cause the formation of sludge and there by shortening the life of compressor. Therefore, the non-condensable gas in the cycle should not exceed 1% volume. The recommendable vacuum is.8 mmhg, and the evacuation time must be 45 minutes or more with the capacity of vacuum pump of 3L/min or more and it is better to vacuum simultaneously in low and high pressures sides for at least 45 minutes with a pump per system. For achieving better performance and long life reliability in domestic refrigerator and freezer, purity of a, R6 a and hydrocarbon mixture R29/R6 a was equal to 99.5%, that the purity of refrigerants which are used in household refrigeration cycle should be more than 99.5%. The following steps to be followed for the experimental analysis: 1. At first leakage tests are done by using soap solution in order to test the condenser and evaporator pressures and check purging daily for 1 hours and found that there are no leakages which was required absolutely for the present investigation to implement further experiment. 2. Charge the 15 g of R134a refrigerant with the help of charging unit and weight measuring device with +.1gm accuracy. 3. Switch on the refrigerator and observed for 3 hour and then the pressure and temperature readings at each inlet and outlet sections of compressor, condenser and evaporator are taken. 4. The characteristic performance of the existing system is investigated, with the help of pressure gauge and temperature readings at certain intervals of temperature difference. 5. The actual refrigerating capacity and cop of the refrigerated system were calculated as per the procedure 6. The energy consumption of the compressor also measured by the energy meter readings. Similarly other two refrigerants (R6a and HC Mixture (R29/R6a)) were tested with different weights of 5 g, 55g, and 6g charged as above process with the help of refrigerant charging unit. And next similar observations are noted down such as suction and discharge compressor pressures, at compressor inlet & outlet, condenser outlet and evaporator outlet. The measured values were used for study the characteristic performance of the system. IV.RESULT AND DISCUSSION By adopting the above described test procedure, performance parameters and energy consumption with R134, R6 and of defined weights were conducted. The experimental results obtained from the performance analysis of 5g, 55g and 6 g of R6 a and 5g,55g,and 6 g of ( R29/R6 a) are discussed with reference to the parameters such as Net refrigeration effect, compressor work, energy consumption, COP. 4.1. Net Refrigeration effect Fig.2 shows the variations of net refrigerating effect with respect to weight of the refrigerants. It was noted that the has the highest refrigerating effect than the other two refrigerants R134a and R6 a. It is also observed that low charge of the HC refrigerant gives JETIR17144 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 279

C.O.P compreassor work(kj/kg) Net refrigeration effect(kj/kg) October 217, Volume 4, Issue 1 better result than the other two refrigerants. For -1 c temperature, gives 16.3%, 21.4% 19.3% and 52.98% higher RE than R6a(5g,55g,6g) and R134a respectively. From the above has highest RE than the other refrigerants. 6 4 2 Figure.2 Net refrigeration effect Vs mass of refrigerants R6a, (R29/R6a 5/5 by wt%) and R134a at -1 c evaporator 4.2. Compressor work Fig.3 shows the variations of compressor work with respect to weight of the refrigerants. It was noted that the has the highest compressor work than the other two refrigerants R134a and R6a. It is also observed that higher discharge pressure of increases the work of the compressor than the other two refrigerants. For -1 c temperature gives 9.4%,13.7%, 11.8% and 53.5% higher RE than R6a (5g,55g, and 6g ) and 15g of R134a respectively. From the above, 5 g required lower work than the other weight of refrigerants. 2 15 r 6a 1 5 R6 a Figure.3 Compressor work Vs mass of refrigerants R6a, (R29/R6a 5/5 by wt%) and R134a at -1 c evaporator 4.3. Coefficient of performance Fig.4 Shows the variations of coefficient of performance with respect to weight of the refrigerants. It was noted that the 5g of HC mixture has the highest coefficient of performance than R6a.it is also observed that higher RE of increases the COP than the R6. For -1 c temperature, 5g gives 6.2% higher than R6a, but cop of R134 has highest cop due to its lower compressor work. 2.3 2.2 2.1 2 1.9 R6a Figure.4 COP Vs mass of refrigerants R6a, (R29/R6a 5/5 by wt%) and R134a at -1 c evaporator 4.4. Power consumption Fig.5 shows the variations of power consumption with respect to the weights of refrigerants. It was noted that the has consumed less power than the R6a. 6 g of R6a refrigerant had consumed 1.731 KW of power. But R134a consumed least power than the and R6a. JETIR17144 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 28

Heat rejected in condenser (KJ/KG) Time taken (min) power consumption(kw) October 217, Volume 4, Issue 1 1.75 1.7 1.65 1.6 1.55 1.5 1.45 Mass ofrefrigerants R 6 a Figure.5 Power consumption Vs R6a, (R29/R6a 5/5 by wt%) and R134a at -1 c evaporator 4.5. Time taken Fig.6 shows the variations of time taken with respect to the mass of refrigerants. It is clear that among all the refrigerant masses, 5 g of has taken 32.2 minutes of time to deliver the performance of the system which was less amount of time. Whereas 5 g of R6a is the next opted refrigerant. 8 6 4 2 R6 a Figure.6 Time taken Vs mass of refrigerants R6a, (R29/R6a 5/5 by wt%) and R134a at -1 c evaporator 4.6. Heat rejected in condenser Fig.7 shows the variations of heat rejection in condenser with respect to the mass of refrigerants. It is clear that among all the refrigerants R134a has rejected less heat in the condenser i.e., 261 KJ/Kg. Greater the heat rejection in the condenser, higher the performance of the refrigeration system. It was observed that 5 g of has the highest amount of heat rejection in the condenser than the all refrigerant masses. 6 4 2 Massof refrigerants R6 a R134 Figure.7 Heat rejected in condenser Vs R6a, (R29/R6a 5/5 by wt%) and R134a at -1 c evaporator 4.7. Energy meter readings Fig.8 shows the variations of energy meter readings with respect to the mass of refrigerants. It is clear that R134a refrigerant has the highest energy meter reading.15 KWH. The more energy meter reading, the greater the emission of gases in to the atmosphere. So, it is noted that R6a has the low energy emission to the atmosphere. JETIR17144 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 281

Energy meter readings (KWH) October 217, Volume 4, Issue 1.16.14.12.1.8.6.4.2 refrigerants R 6 a R134 Figure.8 Energy meter readings Vs refrigerants R6a, (R29/R6a 5/5 by wt%) and R134a at -1 c evaporator V.CONCLUSION From the above discussion Refrigeration effect of has the 16.3%, 21.4% and 19.3% higher than the R6a for the masses 5g, 55g and 6g respectively. And has 52.9% higher than 15 g of R134a refrigerant. Compressor work of has 9.4%, 13.7% and 11.8% higher than the R6a for the masses 5g, 55g and 6g respectively. And has 53.7% higher than 15 g of R134a refrigerant. COP of has 6.25%, 6.7% and 6.4% higher than the R6a for the masses 5g, 55g and 6g respectively. And has 1.54% lower than 15 g of R134a refrigerant. Power consumed by has 5.5%, 6.77% and 6.78% lower than the R6a for the masses 5g, 55g and 6g respectively. And has 1.6% higher than 15 g of R134a refrigerant. Heat rejection in condenser of has 14.1%, 18.9% and 16.8% higher than the R6a for the masses 5g, 55g and 6g respectively. And has 53.2% higher than 15 g of R134a refrigerant. Energy meter readings of has 3%, higher than the R6a. And has 13.3% lower than 15 g of R134a refrigerant. Time taken by has 16.1%, 17% and 22.3% higher than the R6a for the masses 5g, 55g and 6g respectively. And HC mixture has 39.6% lower than 15 g of R134a refrigerant. From all the above results, it was concluded that, all the performance parameter values for R134a, R6a, and s bear similar. It is recommended that 55g of may be adopt as the best alternative refrigerant to the R134a refrigerant. And 6 g of R6 a might be the next appropriate alternative refrigerant to R134a refrigerant applications. REFERENCES [1] E.Jhonson, Global warming from HFC, Environmental Impact Assessment Review18 (1998) 485-492. [2] E Bodio, M.Chorowski, M.wilczekk, Working parameters of domestic refrigerators filled with propane-butane mixture, Rev. Int.Froid.16(5)(1993) 353-356 [3] Richardson RN, Butterworth JS. The performance of propane/isobutene mixtures in a vapour-compression refrigeration system. International journal of.refrigeration 1995;18(1):58-62. [4] M.A. Sattar. R. Saidur, H.H. Misjuki, Pure butane as refrigerant in domestic refrigerator-freezer, in: GMSARN International Conference on Sustainable Development: challenges and Opportunities for GMS, Thailand. December 12-14,27. [5] M.Mohanraj, S.Jayaraj,C.Muraleedharan,P.Chandrasekar, Experimetal investigation of R29/R6a mixture as an alternative to R134a in a domesic refrigerator, Int.J.Termal of sciences 48 (29) 136-142. [6] M. Mohanraj. S. Jayaraj, C. Muraleedharan. A review on recent developments in new refrigerant mixtures for vapor compression based refrigetation,air-conditioning and heat pump units, Int.J.Energy Res..35 (8) (211) 647-669 [7].K. Mani. V, Selladurai, Experimental analysis of a new refrigerant mixture as drop in eplacement for CFC12 and HFC 134a Int. J. Therm. Sci. 47 (28) 149-1495. [8] J.U.Ahamed,R.Saidur, H.H.Masjuki. Thermodynamic aperformance ananlysis of R6 and R6a aas refrigerants, Eng. E- Trans. (21) 11-18. [9] Shengshan Bi, Kai Guo,Zhigang Liu, Jiangtao Wu, Performance of a domestic refrigerator using Tio 2 -R6a nano-refrigerant as working fluid, Energy conversion and Management 2(211)733-737. [1] Mohd.Aasim Nazeer Ahmad Quraishi, U.S.Wankhede. Use of hydrocarbons and other blends as refrigerant. Int.J. Modern Engg. Res. 3 (213) 25-253. [11] Medi Rasti,Seyedfoad Aghamiri,Mohammad-Sadegh Hatamipour, Energy efficiency enhancement of a domestic refrigerator using R436a and R6a as alternative refrigerants to R134a. Int.J.Thermal Sciences 74 (213) 86-89. [12] Deepak Paliwal, S.P.S.Rajput, Experimental analysis of alternative refrigerant as replacement of HFC134a.Int. J. advance Res.Sci. Engg, 4 (215) 191-21. JETIR17144 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 282