EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Similar documents
Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

ADVANCES in NATURAL and APPLIED SCIENCES

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

DEEPAK PALIWAL, S.P.S.RAJPUT

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

CHAPTER 1 INTRODUCTION

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

HFC/HC BLEND FOR CAR CLIMATE CONTROL WITH MINERAL OIL AS LUBRICANT

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

*Corresponding author;

Study of R161 Refrigerant for Residential Airconditioning

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

Technology Application of Environmental Friendly Refrigeration (Green Refrigeration) on Cold Storage for Fishery Industry

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

A Comparison Between Refrigerants Used In Air Conditioning

Performance investigation of Air-conditioning system using ejector as expansion device

Theoretical performance evaluation of R134a and its low GWP Hydrocarbon alternatives in Domestic Refrigerator

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

Optimization of Capillary Tube Parameters in Vapour Compression System using Environmentally Friendly Refrigerant R1234yf

Department of MCE, Islamic University of Technology 2. Abstract

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

A Review on selecting an Eco-friendly Refrigerant alternate to R134a in Domestic Refrigerators

η second law = Second law efficiency

IJESRT. (I2OR), Publication Impact Factor: (ISRA), Journal Impact Factor: 2.114

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Comparative Exergy Analysis of Vapor Compression Refrigeration System Using Alternative Refrigerants

International Journal of Advance Engineering and Research Development

International Journal of Informative & Futuristic Research ISSN (Online):

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

Use of fourth generation ecofriendly refrigerants in two and three cascade refrigeration systems for reducing global warming and ozone depletion

Keywords: Climate change; ozone depletion; Montreal protocol; eco-friendly refrigerant; hydrocarbon refrigerant; performance analysis.

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Low GWP Refrigerants for Air Conditioning Applications

EXPERIMENTAL STUDY ON R1234YF HEAT PUMP AT LOW AMBIENT TEMPERATURE AND COMPARISON WITH OTHER REFRIGERANTS

COMPARATIVE PERFORMANCE ANALYSIS OF EXPERIMENTAL FRIGORIFIC AIR CONDITIONING SYSTEM USING R-134A AND HFO-1234YF AS A REFRIGERANT

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation

International Journal of Multidisciplinary Research and Modern Education (IJMRME) ISSN (Online): (

Sustainability of Automobile Air- Conditioning System Using Refrigerant R1234yf Instead of R134a

JJMIE Jordan Journal of Mechanical and Industrial Engineering

International Journal of Research in Engineering and Innovation Vol-2, Issue-2 (2018),

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Performance Measurement of R32 Vapor Injection Heat Pump System

ISSN Electronic International Interdisciplinary Research Journal (EIIRJ) Bi-monthly Reviewed Journal Mar- April 2015

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Oyelami S., Bolaji B. O.

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Comparative Performance Analysis of Domestic Refrigerator using R12, R134a and R600a Refrigerants

Chapter 10. Refrigeration and Heat Pump Systems

Experimental investigation on the performance of air conditioner using R32 Refrigerant

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

ENERGY PERFORMANCE ASSESSMENT OF R134A/LPG BLEND AS REPLACEMENT OF R134A IN VAPOR COMPRESSION REFRIGERATION SYSTEM

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Thermodynamic Cycle Analysis of Mobile Air Conditioning System Using HFO-1234yf as an Alternative Replacement of HFC-134a

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

ADVANCES in NATURAL and APPLIED SCIENCES

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

International Engineering Research Journal (IERJ) Special Issue Page , June 2016, ISSN

CH2351 Chemical Engineering Thermodynamics II Unit V Refrigeration. Dr. M. Subramanian

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Refrigerants Retrofit as Alternative for R12 and R134a in Household Refrigerators

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

STUDY AND PERFORMANCE ANALYSIS OF ECO-FRIENDLY REFRIGERANT FOR RETROFITTING R22 IN RESPECT TO BANGLADESH

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

SIMULATION OF POTENTIAL REFRIGERANTS FOR RETROFIT REPLACEMENT

Theoretical analysis of low GWP mixture R600a/ R1234ze as a possible alternative to R600a in domestic refrigerators

Experimental study of R600a and R436a to replace R134a in a domestic refrigerator and freezer

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

A Review Paper on Comparative Study of Household- Refrigerator with Alternative Low Global Warming Potential Refrigerants

CHAPTER 1 INTRODUCTION

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

TEST REPORT #47. System Drop-in Test of R-32 and Refrigerant Blends ARM-71a, HPR2A, L-41-2 and DR-5A in a Five-Ton R-410A Rooftop Packaged Unit

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

PERFORMANCE OF REFRIGERATOR USING R-600A AS REFRIGERANT

Experimental Investigation on R 290 and R 600a In a Vapor Compression Refrigeration

VCR SYSTEM USING R-600a/ POE OIL/MINERAL OIL/NANO-SiO 2 AS WORKING FLUID: AN EXPERIMENTAL INVESTIGATION

Transcription:

Karthikeyan, K. et al.: Experimental Investigations on Automobile Air S515 EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE by Karthikeyan KANDHASWAMY a* b, Somasundaram PERIASAMY, Sivakumar MAYILSAMY c a, and Saravanakumar THANGAVEL a Department of Mechanical Engineering, Sri Ramakrishna Engineering College, Coimbatore, Tamil Nadu, India b Department of Automobile Engineering, Kongu Engineering College, Erode, Tamil Nadu, India c Department of Basic Engineering, College of Fisheries Engineering, Tamil Nadu Fisheries University, Nagapattinam, India Original scientific paper https://doi.org/10.2298/tsci17s2515k In this work, the performance of R134a based automobile air conditioning system has been evaluated by retrofitted with R290/R600a mixture (in the ratio of 50:50, by mass), as an alternative. The performance was evaluated at five different operating speeds (1000, 1500, 2000, 2500, and 3000, which covers the entire range of working conditions) with four different cabin load (100, 200, 300, and 400 W). The condenser inlet air temperature was varied in the range between 30 and 50 C, which covers the entire climatic variations in Coimbatore city of India. The performance characteristics such as, refrigerating effect, coefficient of performance, compressor power consumption, and compressor discharge temperatures were considered for comparison. The results showed that, hydrocarbon mixture has faster cooling rate due to its high latent heat of vaporization, 5% higher coefficient of performance due to higher refrigeration effect, 8-10 K lower compressor discharge temperature due to its lower specific heat ratio with 5% lower compressor power consumption due to its lower viscosity and lower liquid density. The charge requirement of R290/R600a mixture is about 50% less compared to R134a. However, the mixture composition is considered as an interment replacement in automobile air conditioners due to composition shift under leakage conditions. Hence, R290/R600a mixture is considered as an interim energy efficient and environment friendly option in R134a automobile air conditioners to extend its life. Key words: automobile air conditioners; R290/R600a mixture Introduction Automobile air conditioners are working on vapor compression cycle using halogenated refrigerants. The halogenated refrigerants are having good thermodynamic, thermophysical and chemical properties. However, their environmental properties are poor due to its ozone depletion potential (ODP) and global warming potential (GWP) [1]. According to Montreal protocol 1987, the use of R12 in refrigeration, air conditioning and heat pump sys- * Corresponding author, e mail: karthikvinu04@gmail.com

S516 Karthikeyan, K. et al.: Experimental Investigations on Automobile Air tem have been phase-out due to its high ODP and GDP. The R134a has taken up the position of R12 in automobile air conditioners during the year 1995 due to its zero ODP and low GWP of 1300. In 1997, Kyoto protocol has identified six green house gases, which includes hydroflurocarbons (HFC) using as refrigerant in refrigeration, air conditioning and heat pump systems [2]. In 2016, more than 190 countries around the world have agreed to reduce to the consumption of HFC refrigerants in refrigeration, air conditioning and heat pump system due to its high GWP. More than 90% of the existing automobile air conditioning in India is working with R134a as a working fluid due to its good thermodynamic and thermophysical properties. However, R134a has high GWP of 1430. Hence, it is essential to identify a new energy efficient and environment friendly to meet the current requirements in automobile sector. During last two decades, many research and development investigations have been reported on environment friendly alternative refrigerants for automobile air conditioners, which are summarized in earlier published review articles [3, 4]. The review work confirmed that, R152a, hydrocarbon based mixtures (such as, R290/R600/600a, R134a/R290/R600a), and R744 as possible alternatives to R134a based automobile air conditioners. However, these refrigerants have certain drawbacks in retrofitting in the existing systems due to mismatch in operating pressure. The hydrocarbon refrigerants are possible alternatives to R134a in automobile air conditioners [5, 6]. The refrigerant R1234yf has been proposed as a possible alternative to phase out R134a by many researchers around the world due to its zero ODP and low GWP [7]. The R1234yf has similar thermodynamic and thermophysical properties with R134a. Hence, it is possible to replace R1234yf in R134a systems without major modifications [8]. Another possible alternative is R1234ze, which can similar thermodynamic and thermophysical properties with R134a. Hence, it is possible to replace R134a in automobile air conditioning systems using R1234ze without major modifications [9]. The hydrofluroolefins will form tri-fluro-acedic acid, which are more harmful to aquatic. From cited review, it is observed that many research and developments have been investigated on the performance evaluation of automobile air conditioning systems. However, the possibility of using locally available R290/R600a hydrocarbon mixture in automobile air conditioner is not reported in open literature. Hence, an attempt has been made in this research work to explore the possibility of using locally available hydrocarbon refrigerants in automobile air conditioning systems and explored its feasibility for retrofitting. Characteristics of refrigerants In fig. 1, the vapor pressures of different refrigerants with reference to temperatures are illustrated. Refrigerant R290 has a higher saturation pressure than the existing refrigerant for the working temperature range. Refrigerant R600a and hydrocarbon mixture (R290:R600a 50:50, by mass) has working pressure below R134a. Generally for selection of the alternate refrigerants, the saturation or the vapor pressure should not exceed the value of the existing system and it should be greater than the atmospheric pressure. It is clear that the refrigerant R290 cannot be used as an alternative refrigerant as replacement for R134a. The latent heat of Figure 1. Saturation pressure curve for different refrigerants the refrigerants considered in this research work is illustrated in fig. 2. From fig. 2, it is con-

Karthikeyan, K. et al.: Experimental Investigations on Automobile Air S517 firmed that hydrocarbon refrigerants have high latent heat of vaporization. Higher cooling rate can be expected with hydrocarbon refrigerants when compared with R134a. The liquid densities of investigated refrigerants are shown in fig. 3. Lower the liquid density is preferable to reduce the refrigerant change requirement. From fig. 3, it is observed that, the hydrocarbon refrigerants are having lower liquid density when compared to R134a, which confirms that, hydrocarbon charge requirement is low. Figure 2. Latent heat of investigated refrigerants Figure 3. Liquid density of different refrigerants Experimentation The details of experimental set-up, instrumentation and experimental procedure are described in this section. Experimental set-up The schematic diagram of an experimental set-up and its photographic view are depicted in figs. 4 and 5, respectively. The experimental set-up consists of Maruthi Suzuki made Alto LXI model car, 3 HP three phase AC induction motor fitted with variable frequency drive, Figure 4. Schematic diagram of vapor compression refrigeration in automotive air conditioning; T1 compressor inlet temperature, T2 condenser inlet temperature, T3 condenser outlet temperature, T4 evaporator inlet temperature, T5 evaporator air inlet temperature, T6 evaporator air outlet temperature, T7 condenser air inlet temperature, T8 condenser air outlet temperature, T9 ambient temperature, P1 suction pressure, P2 discharge pressure, VFD variable frequency drive

S518 Karthikeyan, K. et al.: Experimental Investigations on Automobile Air Figure 5. Photograph of experimental set-up heater for loading the car cabin and another heater loading the environmental chamber. The compression refrigeration cycle used in the air conditioning system consists of six piston radial piston compressor, air cooled condenser, expansion valve and an evaporator. The temperature inside the vehicle cabin was controlled using thermostat. The heat infiltration into the vehicle cabin was controlled using transparent film in the wind screen. The air velocity approaching the condenser was varied using a 0.75 kw centrifugal blower. The entire system was kept inside a room of 3.35 8.22 3.25 m. The compressor is used to pressurize and pump the refrigerant from evaporator to the condenser side. The high pressure refrigerant gets condensed in the air cooled condenser. The condensed liquid refrigerant is then expanded in expansion device and gets evaporated in the evaporator. The vapor refrigerant then enters into the compressor for further cycle. Speed of the compressor is controlled with the help of the variable frequency drive. Four (K-type) thermocouples were used to measure the temperatures at salient points in the refrigeration cycle, another four thermocouples with same specifications were used for measuring the air temperatures at different locations inside the car cabin and two thermocouples were used for measuring temperature at inlet and outlet of condenser for measuring the air temperature at condenser inlet and outlet. All the thermocouples are having similar accuracy of ±0.2 C and similar technical specifications. Two pressure gauges with an accuracy of ±0.1 bar were installed at compressor suction and discharge to measure the suction and discharge pressures of the system. Two Wattmeters were used for measure the compressor power consumption and heater load separately. The speed of the motor is measured with help of the digital tachometer with an accuracy of ±5 rpm. Experimental procedure Initially, the system was flushed with nitrogen gas to remove the impurities and other non-condensable gases inside the system. Then, high pressure nitrogen gas was released and subjected to vacuum using vacuum pump. The required R134a quantity (about 400 g) was charged in the system according to the manufacturer recommendation. The experiments were carried out according to the procedure described in earlier experimental work [10]. The charge quantity was ensured with the electronic scale with an accuracy of ±0.1 g. Experimental observations were made by varying the speed of the motor, load inside the cabin and

Karthikeyan, K. et al.: Experimental Investigations on Automobile Air S519 condenser inlet air temperature. In order to ensure the reliability of experiments, five trial experiments have been conducted at every operating condition. During, experimentation, the pressure and temperature at typical locations in the refrigerant circuit, air flow measurements through the condenser, air temperature measurements at different locations inside the vehicle cabin and compressor power consumption were measured. After baseline tests with R134a, the refrigerant was recovered and the required quantity of hydrocarbon mixture (HCM) composed of R290 and R600a (in the ratio of 50:50, by mass) was charged. The required quantity of R134a was determined based on liquid density. The HCM quantity was estimated as 140 g based on comparison of liquid density. While retrofitting with HCM, the same polyolester was retained. The experimental trials with HCM have been made similar to the procedure followed in R134a experimentation. All the experimental observations have been made after the system has reached the steady state conditions under each operating conditions. The evaporator cooling capacity was predicted using following equation: Q = mcp ( T T ) (1) evap a out in The coefficient of performance, COP, is calculated by: Qevap COP = (2) PC measured The uncertainties in experiments are estimated using [11]: 2 2 R R R wr = w1 + w2 +... + wn x1 x2 xn where R is a given function, w r the total uncertainty, x 1, x 2, x n are independent variables, w 1, w 2,, w n are the uncertainties in the independent variables. The uncertainties in evaporator cooling capacity and COP are estimated as ±2.5% and ±3.1%, respectively. Results and discussion The results obtained from series of experiments made in an experimental set-up are presented in this section. The variations of evaporator pressure against compressor speed (using R134a and HCM as refrigerants) are depicted in fig. 6. It is observed that, compressor suction pressure of both the refrigerants gets decreased with increase in the compressor speed due to pumping of refrigerant from low pressure side to high pressure side. About 6-9% higher evaporator pressure was observed for HCM when compared to R134a. The pressure inside the evaporator was observed less than 10%, which ensures that the evaporator designed for R134a is quite good for retrofitting with HCM. Similarly, the condenser pressure variations of R134a and HCM during experimentation are compared in fig. 7. It is observed that, the compressor discharge pressure of both the refrigerants gets increased with increase in compressor speed. An increase in compressor speed pumps more quantity of refrigerant to the condenser, which enhances the compressor discharge pressure. The compressor discharge pressure of HCM was about 8-9% higher when compared to R134a. The high condenser pressure ensures better condensation in the condenser. Moreover, it is observed that, the condenser design is safe to withstand the difference in operating pressure while retrofitting with HCM. 2 (3)

S520 Karthikeyan, K. et al.: Experimental Investigations on Automobile Air Figure 6. Evaporator pressure variation against compressor speed Figure 7. Condenser pressure variation against compressor speed The compressor discharge temperature is main factor considered for selecting an alternative refrigerant. The experimental observations of compressor discharge temperature are depicted in fig. 8. It is observed that, compressor discharge temperature gets increased with increase in the compressor speed due to increase in refrigerant mass flow rate through the compressor. An increase in compressor discharge temperature ensures better condensation. The difference in compressor discharge temperature was observed within 5-7 C. The lubricant used in the compressor is not affected due to rise in 5-7 C, which ensures that, operation of compressor using HCM is safe without degradation of lubricant. Moreover, it is observed that, the condenser heat load of both the refrigerants is equal, which ensures the existing condenser used for R134a is compatible for HCM. The compressor power consumption of R134a and HCM are at different compressor operating speeds are compared in fig. 9. It is observed that compressor power consumption of both the refrigerants gets increased with increase in compressor speed. The compressor power consumption of HCM was observed to be higher by about 26% when compared to R134a. The high compressor consumption for both the refrigerants are observed due to increase in refrigerant mass flow rate through the compressor at high operating speed. Figure 8. Variation of compressor discharge temperature against compressor speed Figure 9. Compressor power consumption against speed The variation of refrigerating effect of R134a and HCM are compared in fig. 10. It is observed that, the refrigeration capacity of both the refrigerants gets increased with increase in compressor operating speed. The refrigeration effect of HCM was about 30% higher when compared to R134 due to high latent heat of evaporation. Due to high latent heat of evaporation, the HCM is capable of providing faster cooling when compared to R134a. Moreover, the HCM exhibits higher transfer coefficients in evaporators due to its lower liquid density, lower viscosity when compared to R134a. Further, the variations of COP of both the refrigerants

Karthikeyan, K. et al.: Experimental Investigations on Automobile Air S521 against the compressor speed are compared in fig. 11. The COP of HCM was observed to be higher when compared to R134a in all operating speeds. It is observed that COP of both the refrigerants gets decreases with increase in compressor speed. The COP variations for both the refrigerants were observed in the range between 0.9 and 1.03 and in the range between 0.94 and 1.12 for R134a and HCM, respectively. The compressor power consumption and refrigeration capacity gets increased with increase in compressor speed. The refrigerant mixture is compatible with synthetic lubricant, which is commonly used lubricant in HFC based automobile air conditioning systems. Hence, change of lubricant is not essential in the case of HCM retrofitting. The results observed in this work is similar to the earlier work reported by Wongwises, et al. [7] for the ternary hydrocarbon refrigerant mixture composed of R290/R600a/R600. The R290/R600a mixture is a readily available binary HCM in Indian market for retrofitting. Since, the HCM will not form flammable mixture even under leakage conditions due to less charge inside the system. Figure 10. Variation of refrigeration effect against speed Figure. 11. Variation of COP against speed However, it is essential to use sealed controls while retrofitted with HCM. Moreover, this mixture is an environment friendly and compatible with all the components of the system. Conclusions The following major conclusions are drawn based on the experimental investigations. The refrigerant charge requirement of HCM was about 40% when compared to R134a. The operating pressures levels in compressor suction and discharge are slightly higher when compared to R134a. However, the existing condensers used for R134a is more safe for retrofitting with R134a. The HCM is having high latent heat of vaporization, which ensures better refrigeration effect when compared to R134a. The COP of HCM was found to be higher by about 5% when compared to R134a. The HCM has negligible GWP with zero ODP, which ensures that HCM is more environmentally sustainable. Due to the flammable nature of HCM, it is essential to use sealed control units to avoid flammable risk. This investigation confirms that HCM is a good option for replacing R134a in the existing automobile air conditioners to extend its life. Nomenclature h enthalpy, [kjkg 1 ] m a air mass flow rate, [kgs 1 ] N PC compressor speed, [rpm] compressor power consumption, [W]

S522 Karthikeyan, K. et al.: Experimental Investigations on Automobile Air p pressure, [bar] Q evap refrigeration capacity, [W] RE refrigerating effect, [W] T temperature, [ C] Acronyms COP coefficient of performance GWP global warming potential, (CO 2 = 1) HCM hydrocarbon mixture HFC hydrofluorocarbon ODP ozone depletion potential (CFC = 1) POE polyolester oil References [1] Mohanraj, M., et al., Environment Friendly Alternatives to Halogenated Refrigerants A Review, International Journal of Green House Gas Control, 3 (2009), 1, pp. 109-120 [2] Johnson, E., Global Warming from HFC, Environmental Impact Assessment Review, 18 (1998), 6, pp. 485-492 [3] Mohanraj, M., et al., A Review on Recent Developments in New Refrigerant Mixtures for Vapor Compression Based Refrigeration, Air Conditioning and Heat Pump Units, International Journal Energy Research, 35 (2011), 8, pp. 647-669 [4] Calm, J. M., The Next Generation of Refrigerants Historical Review, Considerations, and Outlook, International Journal of Refrigeration, 31 (2008), 7, pp. 1123-1133 [5] Brown, J. S., et al., Comparative Analysis of an Automotive Air Conditioning Systems Operating with CO 2 and R134a, International Journal of Refrigeration, 25 (2002), 1, pp. 19-32 [6] Maclaine-Cross, I. L., Usage and Risk of Hydrocarbon Refrigerants in Motor Cars for Australia and the United States, International Journal of Refrigeration, 27 (2004), 4, pp. 339-345 [7] Wongwises, S., et al., Experimental Investigation of Hydrocarbon Mixtures to Replace HFC134a in an Automobile Air Conditioning System, Energy Conservation and Management, 47 (2006), 11-12, pp. 1644-1659 [8] Ravikumar, T. S., Lal, D. M., On-Road Performance Analysis of R134a/R600a/R290a Refrigerant Mixture in an Automobile Air-Conditioning System with Mineral Oil as Lubricant, Energy Conservation and Management, 50 (2009), 8, pp. 1891-1901 [9] Fukuda, S., et al., Low GWP Refrigerants R1234ze and R1234ze for High Temperature Heat Pumps, International Journal of Refrigeration, 40 (2014), 1, 161-173 [10] Pottker, G., Hrnjak, P., Experimental Investigation of the Effect of Condenser Sub Cooling in R134a and R1234yf Air-Conditioning Systems with and without Internal Heat Exchanger, International Journal of Refrigeration, 50 (2015), 1, pp. 104-113 [11] Holman, J. P., Experimental Methods for Engineers, Tata McGraw Hill Publishing Company, New Delhi, 2007 Paper submitted: May, 26, 2017 Paper revised: August 30, 2017 Paper accepted: Septebmer 17, 2017 2017 Society of Thermal Engineers of Serbia. Published by the Vinča Institute of Nuclear Sciences, Belgrade, Serbia. This is an open access article distributed under the CC BY NC ND 4.0 terms and conditions.