IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

Similar documents
NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

η second law = Second law efficiency

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

THERMODYNAMIC PERFORMANCE ANALYSIS OF R-600 AND R-600A AS REFRIGERANT

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

STUDY AND PERFORMANCE ANALYSIS OF ECO-FRIENDLY REFRIGERANT FOR RETROFITTING R22 IN RESPECT TO BANGLADESH

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Experimental performance evaluation of vapour compression refrigeration system without nano particles

ENERGY, EXERGY AND SUSTAINABILITY ANALYSIS OF TWO-STAGE VAPOUR COMPRESSION REFRIGERATION SYSTEM

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

CHAPTER 1 INTRODUCTION

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

DEEPAK PALIWAL, S.P.S.RAJPUT

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Performance and exergy analysis of vapour compression refrigeration system using various alternative of R134a.

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

International Journal of Research in Engineering and Innovation Vol-2, Issue-2 (2018),

International Journal of Multidisciplinary Research and Modern Education (IJMRME) ISSN (Online): (

Use of fourth generation ecofriendly refrigerants in two and three cascade refrigeration systems for reducing global warming and ozone depletion

A Comparison Between Refrigerants Used In Air Conditioning

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Department of MCE, Islamic University of Technology 2. Abstract

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

Theoretical performance evaluation of R134a and its low GWP Hydrocarbon alternatives in Domestic Refrigerator

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Comparative Exergy Analysis of Vapor Compression Refrigeration System Using Alternative Refrigerants

Oyelami S., Bolaji B. O.

Chapter 2. Alternatives to HCFCs and their Characteristics

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

PERFORMANCE OF REFRIGERATOR USING R-600A AS REFRIGERANT

Volume 2, Issue 1 (2014) ISSN International Journal of Advance Research and Innovation

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

CHAPTER 1 INTRODUCTION

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Volume 1, Issue 2 (2013) ISSN International Journal of Advance Research and Innovation

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Study of R161 Refrigerant for Residential Airconditioning

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

International Journal of Scientific & Engineering Research, Volume 5, Issue 7, July-2014 ISSN

JJMIE Jordan Journal of Mechanical and Industrial Engineering

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Comparative Performance Analysis of Domestic Refrigerator using R12, R134a and R600a Refrigerants

Low GWP Refrigerants for Air Conditioning Applications

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Performance Study of a Water-to-Water Heat Pump Using Non-azeotropic Refrigerant Mixtures R407C

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

Design and Analysis of Water Cooled Condenser

PERFORMANCE OF A VERY LOW TEMPERATURE REFRIGERATION SYSTEM OPERATING WITH NATURAL FLUIDS

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Optimization of Capillary Tube Parameters in Vapour Compression System using Environmentally Friendly Refrigerant R1234yf

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Assessment of LPG as a possible alternative to R-12 in domestic refrigerators

Experimental investigation on the performance of air conditioner using R32 Refrigerant

International Journal of Advance Engineering and Research Development

Sarthak Thakar, 2 R.P.Prajapati 1

Experimental Evaluation on Exergy Analysis of Vapour Compression Refrigeration System Using LPG with TiO 2 -Nanoparticle

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

LPG Refrigerator. October 2017 IJIRT Volume 4 Issue 5 ISSN:

IJESRT. (I2OR), Publication Impact Factor: (ISRA), Journal Impact Factor: 2.114

Experimental study of R600a and R436a to replace R134a in a domestic refrigerator and freezer

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

ISSN Electronic International Interdisciplinary Research Journal (EIIRJ) Bi-monthly Reviewed Journal Mar- April 2015

A Review on selecting an Eco-friendly Refrigerant alternate to R134a in Domestic Refrigerators

Technology Application of Environmental Friendly Refrigeration (Green Refrigeration) on Cold Storage for Fishery Industry

International Engineering Research Journal (IERJ) Special Issue Page , June 2016, ISSN

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

EXPERIMENTAL INVESTIGATION OF A REFRIGERATOR BY USING ALTERNATIVE ECO FRIENDLY REFRIGERANTS (R600A & HC MIXTURE)

Design of LPG Refrigeration System

ADVANCES in NATURAL and APPLIED SCIENCES

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Performance Assessment of Three Eco-Friendly Hydro-Fluorocarbon and Hydrocarbon Refrigerant Mixtures as R22 Alternatives in Refrigeration Systems

Thermodynamic Cycle Analysis of Mobile Air Conditioning System Using HFO-1234yf as an Alternative Replacement of HFC-134a

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Performance improvement of vapour compression refrigeration systems

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

Transcription:

Proceedings of the International Conference on Mechanical Engineering and Renewable Energy 217 (ICMERE217) 18 2 December, 217, Chittagong, Bangladesh ICMERE217-PI-48 IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R6a AS REFRIGERANT M.A. Razzaq 1*, M.M. Khan 2 and J.U. Ahamed 3 1,2,3 Department of Mechanical Engineering, Chittagong University of Engineering and Technology, Chittagong- 4349, Bangladesh razzaqrazcuet@gmail.com *, mzamanmehedi@gmai.com and jamal293@yahoo.com Abstract- In this experimental work, ir-reversibility of vapor compression air conditioning system with R6a as refrigerant was investigated using second law of thermodynamics. Polyol-ester (POE) oil was used as the lubricant in the split type air-conditioner of capacity of 1TR for the exergetic analysis. The amount of energy consumed by the compressor of the air-conditioner for R6a refrigerant was evaluated and a comparison was shown with R22. An exergetic analysis of this process was summarized to evaluate the amount of exergy destroyed by the airconditioner components such as compressor, condenser and evaporator. It was found that maximum exergy loss occurs in the compressor portion, which was approximately 5% of total exergy loss and expansion device showed the lowest exergetic destruction. Exergy efficiency for R6a was varied from 1% to 16% for different evaporator temperature. Total exergy loss was decreased with the increase of evaporator temperature significantly. Whereas, total exergy losses were increased with the increase in condensing temperature for a given evaporator and ambient temperature. REPPROP 7 software was used to determine the properties of the refrigerants. Keywords: Air-conditioner, Exergy, Ir-reversibility, Exergy destruction and REPROP 7 1. INTRODUCTION The Exergy of a system at a certain thermodynamic state is the maximum amount of work that can be obtained when the system moves from that particular state to a state of equilibrium with the surroundings. The thermodynamic quantity of exergy, which can be used to assess and improve energy systems, can also help better understand the benefits of utilizing green energy by providing more useful and meaningful information than energy alone. Exergy identifies the areas of efficiency improvements and reductions in thermodynamic losses attributable to green technologies. Unlike energy, exergy is not subject to a conservation law (except for ideal processes). A system in complete equilibrium with its environment does not have any exergy. The exergy of a system increases the more as it deviates from the environment. It is reported that the vapor compression refrigeration systems release large amount of heat to the surroundings. As a result of difference in temperatures between the system and the surroundings, irreversibility takes place. This irreversibility degrades the performances of the system components. Losses in a component should be measured to improve the performance of the whole system. The losses in the cycle need to be evaluated considering individual thermodynamic processes that make up the cycle. In evaluating the efficiency of the vapor compression refrigeration system, the most commonly used term is the coefficient of performance (COP), which is related to the first law of thermodynamics. But the first law of thermodynamics does not distinguish between heat and work. It cannot be used to identify the sources of thermodynamic losses in a thermodynamic cycle. The first law gives no information on how, where, and how much the system performance is degraded. On the other hand, second law of thermodynamics can be used to identify and quantify the thermodynamic losses in a cycle. Using the concept of irreversibility, thermodynamic losses (i.e., exergy losses) in vapor compression refrigeration cycle can be measured. Hydrocarbons can be used in the existing airconditioning equipment as a replacement for the conventional refrigerants and are compatible with mineral or synthetic oil. In some cases, no changes in the hardware configuration of the equipment are needed. Hydrocarbons are environmentally friendly and found to have zero ozone depletion potential (ODP) and lower global warming potential (GWP) too. Hydrocarbons are cheaper than R-22 and easily available. Most of the hydrocarbons offer good miscibility with mineral oils and good compatibility with common materials employed in the air-conditioning equipment. The Kyoto Protocol [1] encourages the reduction of GWP including the regulations of hydro fluorocarbons. Table 1 represents the physical and environmental data for ICMERE217

selected refrigerants. From the table it is clear that R6a (isobutene) refrigerants have the zero ODP and lowest GWP. Table 1: Physical and environmental properties of refrigerants. Refrigerant Boiling point ( C) Critical Temperature ( C) ODP GWP R-14-127.9-45.56 739 R-12-29.8 112 1 19 R-11-23.71 197.96 1 475 R-52-45.56 82.2 13 R-13-81.48 28.85 1 144 R-44A -46.5 72.1 3922 R-57-46.7 7.9 39 R-6a -11.7 134.7 3 Fatouh and Kafafy [2] evaluated the possibility of using HCs mixtures as working fluid to replace R134a in domestic refrigerators. In their simulation analysis, the performance characteristics of domestic refrigerators were predicted for various working fluids such as R134a, propane, commercial butane, and propane/isobutane/nbutane mixtures with various propane mass fractions. They found that pure butane has low COP and high operating pressures. J.U. Ahamed et. al. [3] investigated experimentally the influence of HC refrigerants on a vapor compression refrigeration system based on exergetic performance. They concluded that exergy loss for butane and isobutene was lesser than that of the refrigerant R134a. For higher evaporating temperature exergy loss was decreased for all refrigerants. Exergy efficiency was also higher for butane compared to that of isobutene and R-134a as refrigerants. Exergy loss in the compressor was higher than that in the other parts of the system i.e. up to 69% of the total exergy loss occurs in the compressor. Reddy et al. [4] studied numerically on a vapor compression refrigeration system using R134a, R143a, R152a, R44A, R41A, R52 and R57A and reported the influence of evaporator temperature, degree of sub-cooling at condenser outlet, superheating of evaporator outlet, vapor liquid heat exchanger effectiveness and degree of condenser temperature on COP and exergetic efficiency. They concluded that evaporator and condenser temperature have significant effect on both COP and exergetic efficiency and also found that R134a has the better performance while R47C has poor performance in all respect. Venkataiah et al. [5] presented the simulation of a 1.5-ton capacity room air conditioning system with some selected refrigerants having their suitability as alternative refrigerants to R22 for air conditioning system. The refrigerants with zero Ozone depletion potential refrigerants R22, R134a, R44A, R47C, R41A, R57A, R29 and R6a considered their analysis. They used COOLPACK software for the analysis of thermodynamic properties. The analysis mainly focused on obtaining results of parameters like heat rejection rate, mass flow rate of refrigerant, displacement volume, power input, discharge temperature, COP, saturation pressure and pressures ratio with fixed condenser temperature and with variable evaporator temperatures. Arcaklioglu et al. [6] calculated rational efficiency and component based irreversibility ratios of a cooling system depending on the second law of thermodynamics using HFC and HC-based pure refrigerants, such as, R32, R125, R134a, R143a, R152a, R29, R6a and their binary and ternary mixtures, along with R12, R22 and R52 (i.e. CFCs). Park and Jung [7] have investigated thermodynamic performance of two pure HCs and seven mixtures composed of propylene (R127), propane (R29), HFC152a and dimethyl ether (RE17) as an alternative to R22 in residential air conditioners. They have made some tests and results have showed that the COP of these mixtures is up to 5.7% higher than that of R22. Said and Ismail [8] assessed the theoretical performances of R123, R134a, R11 and R12 as coolants. It was established that for a specific amount of desired exergy, more compression work is required for R123 and R134a than R11 and R12. The differences are not very significant at high evaporation temperatures and hence R123 and R134a should not be excluded as alternative coolants. Also, in their study they obtained an optimum evaporation temperature for each condensation temperature, which yields the highest exergetic efficiency. Aprea and Renno [9] studied experimentally, the performance of a commercial vapour compression refrigeration plant, generally adopted for preservation of foodstuff, using R22 and its candidate substitute (R417A) as working fluids. The working of the plant was regulated by on/off cycles of the compressor, operating at the nominal frequency of 5 Hz, imposed by the classical thermostatic control. The reported result indicated that the substitute refrigerant (R417A), which is a non-azeotropic mixture and non-ozone depleting, can serve as a long term replacement for R22; it can be used in new and existing direct expansion R22 systems using traditional R22 lubricants. Also in their analysis, the best exergetic performances of R22 in comparison with those of R417A were determined in terms of the coefficient of performance, exergetic efficiency and exergy destroyed in the plant components. Khalid [1] studied the performance analysis of R22 and its substitute refrigerant mixtures R47C, R41A and R417A on the basis of first law. It was found that the COP of R417A is 12% higher than R22, but for R47C and R41A, COP is 5% lowered as compared to R22, and R417A can be used in existing system without any modification. There is no general rule governing the selection of refrigerants, however there are of course the five classic criteria and those are: Thermos-physical properties Technological Economic aspects Safety Environmental factors No refrigerant is ideal, but the desirable characteristics of ideal refrigerants are considered to be: Normal boiling point below C Non-flammable Non-toxic Easily detectable in case of leakage Stable under operating conditions ICMERE217

Easy to recycle after use Relatively large area for heat evaporation Relatively inexpensive to produce Low environmental impacts in case of accidental venting Low gas flow rate per unit of cooling at compressor Though ideal refrigerant doesn t exist, we required to compare our refrigerant with these ideal characteristics. If a refrigerant has some properties close to these ideal characteristics is appropriate for our experimental work. This work aims at increasing COP and exergy efficiency (EE), and decreasing the ir-reversibility at different components and total ir-reversibility of the air-conditioner. In this work, COP, ir-reversibility at the process that make the cycle, total ir-reversibility and EE are reported compared for different operating condition of the condenser and the evaporator using R6a refrigerant. 2. MATERIALS AND METHODS 2.1 Description of Experimental Setup and Instrumentation Figure 1 represents the schematic diagram of the experimental setup. A split type air-conditioner was used in the experimental process and the compressor was hermitically sealed. The experimental setup consists of compressor, condenser, expansion valve and evaporator. The lubricating oil used was Polyol-ester (POE) oil. Refrigerants was charged through the inlet port. A mega digital electronic scale was used to measure the weight of the refrigerant accurately. Approximately 7gm of the refrigerant was used for the experimental analysis. In this test rig a split-type air conditioner was installed. The main loop of the system under study consists of five basic components (compressor, evaporator, condenser, capillary tubes and liquid line filter-drier) as shown in Figure 1. The experimental setup was located in a closed psychometric loop. To measure the inlet and outlet temperature of the compressor two digital thermometer was installed. The other two thermometer was used to measure the inlet and outlet temperature of condenser and evaporator respectively. The HIOKI True-RMS Clamp Meter was used to measure the power consumption by the compressor. It was used to read the voltage (volt), currents (amp), resistance and continuity which need to calculate the power (kw) that had been consumed by the air-conditioner unit during running with different refrigerants. Precision thermometer with an accuracy of ±.1 C is used to measure the room temperature. To know the condition of the room a hygrometer is set in the room to detect the atmospheric condition i.e. relative humidity, dry bulb and wet bulb temperature. In this experiment suction and discharge temperature is important. The air conditioner was instrumented with two pressure gauges at the inlet and outlet of the compressor. The power consumption and the readings of the temperature sensor and pressure gauge are taken within some intervals during day time. Data was taken for three days for different ambient temperatures. Fig. 1: Schematic diagram of experimental setup. 2.2 Mathematical Formulation Mathematical formulation for exergy analysis in different components can be arranged in the following way, Specific ir-reversibility at any state is given by ψ i = (h i h ) - T (s i s ) (1) For evaporator, I ev = ṁ [(ψ 4 ψ 1 ) + Q ev (1 T T ev ) = ṁ[(h 4 h 1 ) T (s 4 s 1 )] + Q ev (1 T ) (2) T ev For compressor, Compressor work W c = ṁ(h 2 h 1 ) (3) Electrical power, W W el = c (4) ɳ mech ɳ el Thus, I comp = ṁ[(ψ 1 ψ 2 ) + W el = ṁ[(h 1 h 2 ) T (s 1 s 2 )] + W el (5) For condenser, Q cond = ṁ(h 2 h 3 ) (6) I cond = ṁ[(ψ 2 ψ 3 ) + Q cond (1 T T cond ) = ṁ(h 2 h 3 ) T (s 2 s 3 ) + Q cond (1 T T cond )(7) In expansion device, I exp = ṁt [(ψ 4 ψ 3 ) (8) Total Ir-reversibility, I total = I ev + I comp + I cond + I exp (9) Exergetic efficiency, ɳ exergy = ψ 4 - ψ 1 W el = (h 4 - h 1) T (s 4 - s 1 ) W el (1) Here h and s represents enthalpy and entropy of the vapor compression cycle at different condition of the refrigerants. The enthalpy and entropy of the refrigerants was determined at different temperature and pressure using REPPROP 7 package software. Figure 2 shows the p-h diagram of the vapor compression system used for the air conditioner. ICMERE217

Power Consumption (kwh) COP total ir-reversibility occurred in the components of the air-conditioner. Figure 5 shows the ir-reversibility occurred in the different components of the airconditioner for different ambient temperature. From the figure, it can be concluded that, compressor is the highest exergy destroying components in the air-conditioner unit. Ir-reversibility destruction is minimum for the expansion device for the air-conditioner. In the compressor, irreversibility was maximum at an ambient temperature of 31 C. 1 8 6 Fig. 2: P-h diagram of a VCR system 3. Results and Discussion 3.1 Power Consumption Data was collected for three consecutive days and for three different temperatures. Data was taken for a twenty minute time interval. Power consumption was varied with day time because the outside or ambient temperature changed with different day. Data was collected for R22 and R6a refrigerants. The variation of power consumption is represented in the Figure 3. It is observed from the figure that, power consumption is higher for R22 refrigerants for different ambient temperature..8.78.76.74.72.7.68.66.64 Variation of power consumption 29 3 31 Ambient Temperature ( C) R22 R6a Fig. 3: Variation of power consumptions 3.2 Coefficient of Performance The average COP for different environmental condition was compared for R22 and R6a refrigerants. It was found that, COP increased up-to 184% for R6a refrigerant compared with R22. Figure 4 shows a graphical presentation of the COP of the refrigerants. It was also found that, COP decreased with the increase of ambient temperature. Table 2 shows the variation of COP with the ambient temperature. 4 2 Fig. 4: Variation of COP Table 2: Average COP for different ambient temperature Date R-22 R-6a Ambient temperature ( ) Refrigerants Average COP Day 1 31 9.26 COP decreased, % Day 2 3 11.75 26% Day 3 29 1.56 14% The variation of total exergy associated with different evaporator temperature in the process is illustrated in Figure 6 (a), (b) and (c) for different ambient temperature. In every case, total exergy decreased as the increment of evaporator temperature. Exergy efficiency (EE) denotes the exergetic performance of the system. Figure 7 (a), (b) and (c) shows the variation of EE with the evaporator temperature for different ambient temperature. From the Fig.7, it is apparent that, EE decreased with the change of evaporator temperature for every ambient temperature. Figure 5 indicates that compressor destroys maximum amount of exergy which is about 5% of the total exergy of the process. Expansion device destroys minimum amount of exergy comparing with other components in the air-conditioner. Table 3 shows the percentage of exergy destroyed in the compressor section for different ambient temperature. As the ambient temperature decreases, contribution of compressor to the total exergy reduced as the total exergy. 3.3 Ir-reversibility at the process Total ir-reversibility at the process is the summation of ICMERE217

Total exergy loss () Total exergy loss (kj/kg) exergetic efficiency (%) Total exergy loss () exergetic efficiency (%) exergy loss () Exergetic efficiency (%) 1 8 6 4 2 Fig. 5: Variation of exergy loss for different components of a refrigerating system in different ambient temperature. 5 4 3 2 1 Different components Day 1 Day 2 Day 3 22.2 22.4 22.6 22.8 23 23.2 35 34.5 34 Evaporator Temperature ( C) (a) 33.5 2.5 21 21.5 Evaporator Temperature ( C) (b) 5 4 3 2 1 21.5 22 22.5 23 23.5 Evaporator temperature ( C) (c) Fig. 6: Variation in total exergy loss with evaporator temperature for ambient temperature of (a) 31 C (b) 3 C and (c) 29 C. 16 14 12 1 8 6 4 2 22.2 22.4 22.6 22.8 23 23.2 25 2 15 1 5 (a) (b) (c) Fig. 7: Variation of exergetic efficiency with evaporator temperature for ambient temperature of (a) 31 C (b) 3 C and (c) 29 C. Table 3: Percent of exergy loss in compressor Ambient temperature Evaporator temperature ( C) 2.4 2.6 2.8 21 21.2 21.4 21.6 2 15 1 5 Evaporator temperature ( C) 22 22.5 23 23.5 Evaporator temperature ( C) Total exergy loss () Compress or exergy loss () Contribution of compressor (%) 31 147.1 9.49 61.33% 3 135.42 65.42 48.3% ICMERE217

29 148 68.47 47% 4. Conclusion In this study an ideal vapor-compression refrigeration system is considered for performance comparison of R6a in different ambient temperature. Hydrocarbon is considered as the most suitable refrigerant for air conditioners due to its zero ODP, low GWP and availability. Although hydrocarbons and their mixtures have some flammability problems, but they have better energy performance (COP) and high cooling capacity as well as exergy efficiency compared to the CFC/HCFC refrigerants. HC mixtures are miscible with both mineral oil and synthetic lubricants. From this research work, the following conclusion can be summarized: Energy consumption rate for R6a is much lower than R22 The COP is increased with the increase of evaporator temperatures for any ambient temperature. It is observed that a small fluctuation is occurred in COP for different ambient temperatures. Total ir-reversibility are decreased with the increase of evaporator temperature significantly. Total exergy losses increase with the increase in condensing temperature for a given evaporator and ambient temperature. Exergy efficiency decreases with increase in evaporator temperature at any given ambient temperature. Most exergetic components of a refrigerating system is compressor and minimum exergy loss happen in expansion device. Over 5% exergy loss occur in compressor for R6a. Vol. 46 No. 9 1, pp. 1595 1611. 25 [7] K.Park and D. Jung, Performance of heat pumps charged with R17/R29 mixture, Applied Energy, Vol. No. 86, pp. 2598-263, 29. [8] S.A.M Said and B.Ismaily, Exergetic assessment of the coolants HCFC123, HFC134a, CFC11, and CFC12, Energy, Vol. 19 No. 11, pp. 1181 1186, 1994 [9] C. Aprea and C. Renno, Experimental comparison of R22 with R417A performance in a vapour compression refrigeration plant subjected to a cold store, Energy Conversion Management, Vol. 45 No. 11 12, pp. 187 1819, 24 [1] M.A. Khalid, Comparison of performance analysis of R22 and its alternate, 11th HVACR Conference, Karachi, pp. 56 67, 26 6. NOMINCLATURE Symbol Meaning Unit T h s ṁ P Ψ Q cond Q ev ɳ exe I ev I comp I cond I exp I total Ambient temperature Enthalpy Entropy Mass flow rate Pressure Specific exergy Condenser refrigeration capacity Evaporator refrigeration capacity Exergy efficiency Evaporator ir-reversibility Compressor ir-reversibility Condenser ir-reversibility Expansion device ir-reversibility Total ir-reversibility C kj/k kg/s bar kw kw % 5. REFERENCES [1] K. Protocol. United Nations framework convention on climate change. Kyoto Protocol, Kyoto, 19, 1997 [2] M Fatouh and E.I.M. Kafafy. Assessment of propane/commercial butane mixtures as possible alternatives to R134a in domestic refrigerators. Energy Conversion and Management Vol. 47, pp: 2644 58. 26 [3] J.U Ahamed,, R. Saidur and H. H. Masjuki A review on exergy analysis of vapor compression refrigeration system. Renew and Sust Energ Rev. Vol: 15(3); pp:1593-16; 211. [4] V.S. Reddy, N.L. Panwar and S.C. Kaushik Exergetic analysis of a vapour compression refrigeration system with R134a, R143a, R152a, R44A, R47C, R41A, R52 and R57A, Clean Technologies and Environmental Policy, Vol. 14 No. 1, pp. 47 53,212 [5] S. Venkataiah and V. G. Rao Analysis of Alternative Refrigerants to R22 for Air-Conditioning Applications at Various Evaporating Temperatures. Int. Journal of Engineering Research and Applications, Vol. 4, issue 3, pp. 39-46, 214. [6] E. Arcaklioǧlu, A. Çavuşoǧlu and A. Erişen, An algorithmic approach towards finding better refrigerant substitutes of CFCs in terms of the second law of thermodynamics, Energy Conversion and Management, ICMERE217