K-Band Doppler Sensor Module

Similar documents
K-Band Doppler Sensor Module

Dust sensor SM-PWM-01A SPECIFICATION. Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12

Ultrasonic Proximity Sensor

High Temperature Industrial VRS Magnetic Speed Sensors

Sensor : IRA-S210ST01 Lens : IML-0685/0688 Pyro Electric Infrared Sensor Fresnel Lens Features Applications Excellent S/N Intrusion Detectors

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

HOA6480 Series Barcode Sensor Infrared Products

GP2Y1010AU0F. Compact Optical Dust Sensor. Description. Compliance. Applications. Features GP2Y1010AU0F. 1. Compliant with RoHS directive (2002/95/EC)

Ultrasonic Reflective Sensor

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D. Radar sensor

U5300 Industrial Pressure Transducer

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

FEATURES AND BENEFITS

alarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

NIDS Dust sensor ED-N-DS-1408

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

SIARGO MEMS FLOW SENSING PRODUCTS MEMS Mass Flow/Clog Sensors VC Siargo Ltd. ISO 9001 ISO OHSAS 18001

ML562G84 APPLICATION. Display system. Symbol Parameter Conditions Ratings Unit. Pulse (Duty 40%)

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

onlinecomponents.com

SMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features

DHM5150 Human Motion Sensor Module User Manual

Original instructions Sense7-series Non-contact coded safety switch

R-GAGE QT50R-AFS Sensor

M7100 Pressure Transducer

Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.

MSP100 Pressure Transducer

ML520G55 FEATURES. Package: φ5.6mm TO-CAN PKG APPLICATION. Reverse voltage

Applications PL- N Series Lens Type Sensor Type Serial Number

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D-NA. Radar sensor

MSP340 Pressure Transducer

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

UNISONIC TECHNOLOGIES CO., LTD 88NXX

Model Number Structure

Data Sheet Sensor: IRA-S210ST01 Lens: IML-0685 / IML Sensor : IRA-S210ST01 Lens : IML-0685/0688. Pyro Electric Infrared Sensor Fresnel Lens

2015 Amphenol Advanced Sensors. Jinton Industrial Park, Wujin, Changzhou, Jiangsu, China. Web:

Figure 1. Figure 2. See notes 1 and 2 below.

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

Laser Particle Sensor Module PM2009

U5700 Submersible Liquid Level Pressure Transducer

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

INSTRUCTION MANUAL CLEAN BELLOWS TYPE INDUSTRIAL ROBOT SPECIFICATIONS. Notice

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

ML60171C FEATURES. φ5.6mm TO-CAN PKG (with monitor PD) APPLICATION Motion sensor Printing. Reverse voltage (PD)

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor

ZMOTION Pyroelectric Sensors

M5200 Industrial Pressure Transducer

General Purpose Industrial VRS Magnetic Speed Sensors

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

Instruction Manual Model L2 RF Switch

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

D5100 Industrial Differential Pressure Transducer

DP86 Constant Voltage with Fitting

6502B RF Distribution

MS4525 SPECIFICATIONS

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

Supply voltage (Vcc) Vcc reference to ground V Supply current: off on. Vcc = 5 V, T = 25 C [77 F] Vcc = 5 V, T = 25 C [77 F

ML501P73 TYPE NAME. FEATURES High Output Power: 1.0W (Pulse) 0.5W (CW) High Efficiency: 1.0mW/mA (typ.) Visible Light: 638nm (typ.) 5.

MSP100 Pressure Transducer

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

Model Communication Interface Sensors 2JCIE-BL01 Bluetooth low energy Temperature, Humidity, Light, UVI, Absolute pressure, Noise, Acceleration

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011

- For Continuous Radon Monitoring (CRM) Systems - Ultra Low Power Requirement

Pyroelectric Infrared Sensors

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER

SMART dust sensor for air purifier Description SM-ND-02A SM-ND-02A is a dust sensor that detects the dust particle concentration in air by using optic

MSP300 Pressure Transducer

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

Microwave Doppler Sensors Applications. for Komantech

Ultrasonic Reflective Sensor

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

U5600. Wireless Pressure Transducer SPECIFICATIONS

D5100 Industrial Differential Pressure Transducer

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

NWA300 Field-Based Analog 4-20mA DC Current Meter User's Manual OM

Scale 0: 10 k Scale 50: 10 k (see note 2)

Pressure Sensors: Measurement Type: Gage, Vacuum Gage; Signal Conditioning: Unamplified; Pressure Range: ± 15.0 psi; Port Style: Straight

Pyroelectric Infrared Sensors

Installation Instructions for the

Technical Data Sheet 5mm Infrared LED, T-1

Technical Data Sheet 1.5mm Side Face Infrared LED

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

D6T. Contactless measurement creating energy-efficient and comfortable living spaces. MEMS Thermal Sensors

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

Transcription:

K-Band Doppler Sensor Module RF Frequency: 24.5 to 24.25 GHz Model No. NJR4262 s Rev.-2 February 26, 213 Copyright 213 New Japan Radio Co., Ltd. Microwave Components Division -Notice of Proprietary Information- This document and its contents are proprietary to New Japan Radio Co., Ltd. This publication and its contents may not be reproduced or distributed for any other purpose without the written permission of New Japan Radio Co., Ltd. 1

Caution 1. NJRC strives to produce reliable and high quality microwave components. NJRC's microwave components are intended for specific applications and require proper maintenance and handling. To enhance the performance and service of NJRC's microwave components, the devices, machinery or equipment into which they are integrated should undergo preventative maintenance and inspection at regularly scheduled intervals. Failure to properly maintain equipment and machinery incorporating these products can result in catastrophic system failures. 2. To ensure the highest levels of reliability, NJRC products must always be properly handled. The introduction of external contaminants (e.g. dust, oil or cosmetics) can result in failures of microwave components. 3. NJRC offers a variety of microwave components intended for particular applications. It is important that you select the proper component for your intended application. You may contact NJRC's sales office or sales representatives, if you are uncertain about the products listed in the catalog and the specification sheets. 4. Special care is required in designing devices, machinery or equipment, which demand high levels of reliability. This is particularly important when designing critical components or systems whose foreseeable failure can result in situations that could adversely affect health or safety. In designing such critical devices, equipment or machinery, careful consideration should be given to, amongst other things, their safety design, fail-safe design, back-up and redundancy systems, and diffusion design. 5. The products listed in the catalog and specification sheets may not be appropriate for use in certain equipment where reliability is critical or where the products may be subjected to extreme conditions. You should consult our sales office or sales representatives before using the products in any of the following types of equipment. * Aerospace Equipment * Equipment Used in the Deep Sea * Power Generator Control Equipment (nuclear, steam, hydraulic) * Life Maintenance Medical Equipment * Fire Alarm/Intruder Detector * Vehicle Control Equipment (automobile, airplane, railroad, ship, etc.) * Various Safety Equipment 6. NJRC's products have been designed and tested to function within controlled environmental conditions. Do not use products under conditions that deviate from methods or applications specified in the catalog and specification sheets. Failure to employ NJRC's products in the proper applications can lead to deterioration, destruction or failure of the products. NJRC shall not be responsible for any bodily injury, fires or accidents, property damage or any consequential damages resulting from the misuse or misapplication of its products. PRODUCTS ARE SOLD WITHOUT WARRANTY OF ANY OF KIND, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 7. The product specifications and descriptions listed in the catalog and specification sheets are subject to change at any time, without notice. 2

Category: K-Band Doppler Sensor Module Type Name: NJR4262 Description: Motion detector using microwave doppler effect Miniaturized RF circuit with MMIC technology High accurate I-Q mixer : 1. Electric Characteristics (Common measure condition Ta= +25 deg.c) Min. Typ. Max. Unit Condition / Note 1.1 Operation voltage 3.3-5.5 V 1.2 Operation current - 45 55 ma 1.3 Operation frequency 24.5-24.25 GHz 1.4 E.I.R.P. - +16 (4) +2 (1) dbm (mw) 1.5 Frequency Stability -1 - MHz/deg.C Ta= -2 to +6 deg.c 1.6 Start-up time - 4 6 msec 1.7 2nd Harmonics (E.I.R.P.) - - -3 dbm 1.8 Radiation pattern - - - - See Fig.1: Typical Radiation Pattern. 1.8.1 3dB beam width (H-plane) - 7 - deg. 1.8.2 3dB beam width (V-plane) - 28 - deg. 1.8.3 Side lobe suppression - - - db No side lobe (H-plane) 1.8.4 Side lobe suppression - 13 - db (V-plane) 1.9 Noise Voltage - - 4 mv Upon amplified with 85dB Gain amp. Band width: 1 to 3Hz 1.1 Signal level.5.8 - Vp-p Refer to Fig.2 : Signal Test System 1.11 Offset voltage 1.1 1.35 1.6 V 1.12 I-Q Amplitude Balance -3 - +3 db 1.13 I-Q Phase Balance 85-95 deg. Fig.1: Typical Radiation Pattern H-plane 7 deg. (±35 deg.) V-plane 28 deg. (±14 deg.) V-Plane -6-3 Angle(deg.) 3 6-6 -3 Angle(deg.) 3 6 H-Plane -9-2 -1 (dbm) 1 9 2-9 -2-1 (dbm) 1 9 2 3

2. Mechanical characteristics 2.1 Size 25(W) x 25(D) x 7.3(H) mm Tolerance: ±.5 mm 2.2 Weight 7 g max. 2.3 Interface / Pin assignment Pin Size:.64 mm square Pin Pitch: 2.54 mm Pin IF-I GND IF-Q VCC NC Description Doppler signal output(i). Output impedance:1.5kohm GND Doppler signal output(q). Output impedance:1.5kohm Voltage supply. No connection. Recommended via hole diameter: 1.2 ±.5 mm 3. Environmental characteristics 3.1 Operation Temperature -2 to +6 deg.c 3.2 Storage Temperature -4 to +8 deg.c 3.3 Humidity to 95 % @ +3 deg.c 3.4 Vibration 49.3 m/s 2 (5 G) 3 to 5 Hz, 1 minutes, XYZ direction 3.5 Shock 196.13 m/s 2 (2 G) Half sine, 11 msec, XYZ direction, 3 times 4. Absolute Maximum Rating Min. Typ. Max. Unit Condition / Note 4.1 Supply voltage - 7 V 4.2 Operation Temperature -4 - +85 deg.c No damage 4.3 Storage Temperature -4 - +85 deg.c 4

5. Outline Unit : mm Tolance : ±.3 5

Fig2. Signal Test System DUT 29 db Oscilloscope 14.6 to 24.6cm stroke 7cm Corner reflector RCS =.49m 2 Linear stage 6