Optimised for high ambient operation (up to 55 C ambient) EWAD-MZ. Air cooled chiller

Similar documents
EWAD-TZB. Screw inverter chiller. High efficiency chiller for comfort and process cooling

EWAD-TZ. Air cooled chiller with R-134a inverter driven screw compressor

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

EWAT-B. Multi scroll chiller with R-32 refrigerant. First air cooled chiller with environmental friendly R-32 refrigerant

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

VZ Chiller series. Water cooled inverter chiller. The highest peak in chiller technology

Chillers. Technical Data. EWYD-BZ 250~580 kw

Air conditioners Cooling only

GAS CONDENSING BOILERS RELIABILITY AND PEACE OF MIND

Keep looking you ll never find me. VRV IV heat pumps for indoor installation

DAIKIN Air Handling Unit Modular

Air Conditioners Heating & Cooling

Daikin Altherma hybrid heat pump. The natural combination

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

The natural ombination

FWV 04 FWL 05 FWM 06 FWB 07 FWD 08. Control 09. Accessories 10. Daikin Europe N.V.

High temperature heating system AIR TO WATER HEAT PUMPS. Renovation - Heating - Domestic hot water

water-cooled CHILLERS

Pure comfort & design

Air Conditioning. Technical Data EEDEN RXS-F8

Air Conditioners Heating & Cooling

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

Air Conditioners. Technical Data FTY-H

Air Conditioners Technical Data

WATER-COOLED CHILLERS and condenserless chillers

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

Daikin Altherma Low Temperature monobloc heat pump

Pure comfort & design

Heating. Technical Data EEDEN ERRQ-AY1

water-cooled CHILLERS

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

Air Conditioning. Technical Data EEDEN AZQS-BV1

Air Conditioners Heating & Cooling

Daikin Sensira R-32. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Daikin Sensira. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN FDXM-F

Air Conditioners Heating & Cooling

Daikin Altherma Low Temperature monobloc heat pump

Remote control infrared ARC433B76 ARC433A8 ARC433B69

Air Conditioners Heating & Cooling

Air Conditioners Technical Data

Air Conditioners Heating & Cooling

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

Air Conditioners Technical Data

where innovation meets creativity

Commercial and Technical Data

Fan Coil Units. Technical Data FWC-BT/BF

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

Air Conditioners Technical Data

Air Conditioners Heating & Cooling

air-cooled CHILLERS APPLIED SYSTEMS EWAD AJYNN EWAD AJYNN/A EWAD AJYNN/Q EWAD AJYNN/H

DAIKIN EMURA. FORM. FUNCTION. REDEFINED. THE NEW INDOOR AIR CONDITIONING UNIT FROM DAIKIN.

air-cooled EWAD-AJYNN(A-Q-H) cooling only

Air Conditioners Heating & Cooling

Air Conditioning Technical Data FAA-A > FAA71AUVEB > FAA100AUVEB

The natural. hoice installer leaflet. DAikin Altherma low temperature heat pump

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G

Air Conditioners Heating & Cooling

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling

Air Conditioners Technical Data

Air Conditioners Heating & Cooling

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping

Our mission: beating the winter cold

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

EWWD MBYN EWLD MBYN Applied systems

Air Purifiers. Technical Data MC70L

SUPERB TECHNOLOGY FOR SUPERB INTERIORS

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

Air conditioners, heating & cooling for the retailmarket and offices

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal

Air Conditioning. Technical Data. Low temperature hydrobox for VRV EEDEN HXY-A

Air Conditioners. Technical Data RZQG-L

Air conditioners Heating & Cooling

Designed. colder climates. for AIR TO AIR HEAT PUMPS FTXS K FTXS-20-25K

Product portfolio. Chillers and air side equipment

Daikin leads the way:

gas condensing combi boiler

Air conditioners Heating & Cooling

VRV The total solution. Integrated Climate Control

Pure comfort & design

Air Conditioning. Technical Data. 4-way blow ceiling mounted cassette EEDEN ACQ-C

Air conditioners Heating & Cooling

Air Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8

The plug & play fresh Air Solution

Air Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXG-JW

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

Air Conditioners Heating & Cooling

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B

AIR CONDITIONERS, HEATING & COOLING for your home

for small rooms in multi application

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

for your home FLXS-B Flexi type unit air to air heat pumps

Europe s new energy label: raising the bar on energy efficiency

Air conditioners Heating & Cooling

The natural. hoice installer leaflet. DAikin Altherma low-temperature heat pump. Preliminary version

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

Transcription:

Optimised for high ambient operation (up to 55 C ambient) EWAD-MZ Air cooled chiller

Why choose Daikin? Daikin were the among first to pioneer the use of inverters in air cooled screw chillers. And today, our next generation of inverter technology makes both comfort and process cooling even more efficient and cost-effective. With the highest efficiency at both partial and full load, installers and building owners can give endusers better results all year round comfort with lower noise levels and higher energy efficiency than ever before. For over a decade, hundreds of sites around the world have relied on Daikin inverter driven single screw compressors to reduce their running costs without compromising on climate comfort or performance. With the EWAD-MZB chiller, Daikin has once again improved the chiller performances by increasing the efficiency of the in-house developed compressor with integrated inverter: VVR technology, DC motors,... Further improvements are made by introducing new technologies as microchannel condenser coils and advanced electronic expansion valves. EWAD-MZ Energy efficient cooling that does not compromise on comfort or performance 2

Why choose MZ chiller series? 1 Top class efficiency: EER Up to 2.65 (at 46 C ambient temperature) IPLV Up to 6.60 Best choice for every application Rapid return investement for comfort cooling application compared to standard technology New generation of Daikin inverter screw compressors Integrated inverter, refrigerant cooled Variable volume ratio technology Discharge port Economizer & Liquid injection ports Capacitors Aluminium cooling plate Variable Volume Ratio (VVR) Inverter Liquid inlet (VFD cooling) Suction port Refrigerant cooled inverter Safe and robust cooling system, totally independent from outdoor ambient conditions and air quality Suitable for aggressive installations such as industrial or desert applications DAIKIN solution with integrated Refrigerant cooled inverter Min. compression ratio Max. compression ratio VVR (Variable Volume Ratio) The operating conditions of a chiller are subjected to sensible changes due to the variation of ambient temperature and load request from the plant. Screw compressors increase the pressure of the refrigerant by forcing it into a progressive smaller volume, from the suction to the discharge port. Once that the geometry of the compressor is defined the volume ratio is also defined. Daikin compressors can modify their own geometry thanks to variable volume ratio (VVR). The volume ratio will change by moving the sliding valves. VVR changes the point at which the gas leaves the compressor, and therefore changes the pressures at discharge which will be optimal at any condition. 3

Microchannel condenser coils High thermal efficiency Small volume, resulting in a small refrigerant charge Light & durable design Easy cleaned Refrigerant Desuperheat + Condensing phase + Condensing phase + Subcooling Air flow Refrigerant manifolds Enhanced aluminium fins Flat microchannel tubes Refrigerant 2 Application flexibility Ambient temperature Ambient up to 55 C @ full load Brine (e.g. ice storage food process) Comfort Cooling High temperature process cooling (e.g. data center) Chilled water temperature Chilled water down to -15 C Chilled water up to 20 C 3 Standard flexibility 4 3 efficiency versions available both in 50Hz and 60Hz power supply AHRI certification All models available are certified by AHRI to AHRI Standard 550/590 4

Providing a lifetime of comfort in the most flexible way 5 Simple to install. Even simpler to maintain Our chillers are wired at the factory and are also precommissioned, with the unit s software tuned and set points already established. They also integrate easily with existing building management systems. So on site, all that is required is to plug the unit into the power supply, connect any pipes and wires, and switch the unit on. 6 Proven reliability All our chillers and compressors are subjected to intensive performance, acoustic, endurance and vibration tests in Daikin factories and at selected jobsites - even at extreme working conditions. To ensure maximum reliability in every component and the right, lifelong technical solution for your application. 7 Extensive options list Rapid restart - when a loss of cooling would be catastrophic, the chiller can restart within 30 seconds of the power being restored and reach fullload cooling capacity in less than 6 minutes. VFD pumps - variable frequency pumps can be used to optimise the working efficiency of the chiller and thus maximise energy savings, also in primary only variable flow systems. Refrigerant leak detection - rapid advanced warning of trouble, so you can avoid any environmentally harmful and potentially costly leaks in the refrigerant system. Heat recovery - a plate to plate heat exchanger for each refrigerant circuit is installed in series to the condenser coil. 15 to 85 % of the total heat rejection of the chiller can be recovered Compressor enclosure - to enhance compressor protection Coil treatments - to prevent corrosion in aggressive environment Smart sequencing capability - master/slave sequencing function up to 4 units connected together for system optimisation and without the need of external control systems. Daikin s remote monitoring and control for chiller plants - optimum use and reduced costs over the system s entire lifetime 5

Technical details - EWAD-MZB Cooling only EWAD-MZSSB2 380 450 495 570 610 660 700 820 900 C10 H10 H11 Cooling capacity Nom. kw 379 435 484 552 593 640 681 754 817 910 965 1035 Tons 108 124 138 157 169 182 194 214 232 259 274 294 Power input Cooling Nom. kw 168 192 209 239 259 279 296 318 365 397 433 456 EER 2.26 2.27 2.32 2.31 2.29 2.29 2.30 2.37 2.24 2.29 2.23 2.27 IPLV 4.56 4.61 4.77 4.93 4.96 4.94 4.97 5.01 5.01 5.01 5.02 4.99 Dimensions Unit Height mm 2483 Width mm 2258 Depth mm 4083 4083 4983 5883 5883 5883 6783 6783 6783 7783 8820 10461 Weight Unit kg 4044 4060 4317 4603 4780 4804 5074 6249 6147 6542 6897 8037 Operation weight kg 4202 4224 4475 4761 5050 5059 5329 6532 6632 7027 7382 8490 Water heat exchanger Type Single pass shell & tube Water flow rate Cooling Nom. l/s 16.7 18.9 21.0 24.0 25.6 27.6 29.2 32.7 35.4 39.5 41.8 44.9 Water pressure drop Cooling Nom. kpa 41 52 47 60 48 43 48 66 47 54 60 47 Water volume l 158 164 158 158 270 255 255 283 485 485 485 453 Air heat exchanger Type Microchannel Compressor Type Inverter driven single screw compressor Quantity 2 Fan Type Direct propeller Quantity 8 8 10 12 12 12 14 14 14 16 18 22 Air flow rate Cooling Nom. l/s 45456 45456 56819 68183 68183 68183 79547 79547 79547 90911 102275 125003 Speed rpm 900 Sound power level Cooling Nom. dba 101 100 101 102 102 103 105 104 104 104 104 105 Sound pressure level Cooling Nom. dba 81 80 81 82 81 83 84 83 83 83 82 83 Operation range Air side Cooling Min.~Max. CDB 10~55 Water side Cooling Min.~Max. CDB -8~18-15~20 Refrigerant Type / GWP R134a / 1430 Circuits Quantity 2 Refrigerant charge Per circuit kg 29+29 30+30 34+34 38+38 39+39 42+42 45+45 46+46 46+46 52+52 59+59 72+72 TCO2eq 42-42 43+43 49+49 55+55 56+56 61+61 65+65 66+66 66+66 75+75 85+85 103+103 Power supply Phase/Frequency/Voltage Hz/V 3~/50/400 Notes: Performances are based on the following conditions: evaporator 12.2/6.7 C; ambient 46 C. unit at full load operation; operating fluid: water. Cooling only EWAD-MZXSB2 360 420 450 540 570 610 660 680 770 850 910 C10 H10 C11 Cooling capacity Nom. kw 340 396 446 506 539 584 622 661 740 810 868 952 995 1038 Tons 97 113 127 144 153 166 177 188 210 230 247 271 283 295 Power input Cooling Nom. kw 142 166 186 206 224 242 259 279 285 327 340 378 403 434 EER 2.39 2.38 2.40 2.46 2.41 2.41 2.40 2.37 2.60 2.48 2.55 2.52 2.47 2.39 IPLV 5.01 4.99 4.75 4.89 5.17 5.14 5.05 5.00 5.09 5.11 5.14 5.14 5.03 5.04 Dimensions Unit Height mm 2483 Width mm 2258 Depth mm 4983 4983 5883 5883 5883 6783 7783 7783 7783 7783 8820 9591 10461 11233 Weight Unit kg 4292 4292 4602 4800 4800 5072 5425 5425 6626 6542 6897 7175 7500 7500 Operation weight kg 4450 4450 4760 5055 5055 5327 5680 5680 6927 7027 7382 7660 7953 7953 Water heat exchanger Type Single pass shell & tube Water flow rate Cooling Nom. l/s 14.8 17.2 19.4 21.9 23.4 25.3 27.0 28.7 32.1 35.1 37.6 41.3 43.1 45.0 Water pressure drop Cooling Nom. kpa 55 69 56 54 60 37 41 45 65 46 51 58 44 48 Water volume l 158 158 158 255 255 255 255 255 301 485 485 485 453 454 Air heat exchanger Type Microchannel Compressor Type Inverter driven single screw compressor Quantity 2 Fan Type Direct propeller Quantity 10 10 12 12 12 14 16 16 16 16 18 20 22 24 Air flow rate Cooling Nom. l/s 56819 56819 68183 68183 68183 79547 90911 90911 90911 90911 102275 113639 125003 136367 Speed rpm 900 Sound power level Cooling Nom. dba 101 101 101 102 102 102 103 104 104 104 104 105 105 106 Sound pressure level Cooling Nom. dba 81 81 81 82 81 81 82 83 83 83 82 83 82 83 Operation range Air side Cooling Min.~Max. CDB 10~55 Water side Cooling Min.~Max. CDB -8~18-15~20 Refrigerant Type / GWP R134a / 1430 Circuits Quantity 2 Refrigerant charge Per circuit kg 32+32 32+32 37+37 40+40 40+40 45+45 48+48 48+48 52+52 52+52 59+59\ 65+65 72+72 78+78 TCO2eq 46+46 46+46 53+53 58+58 58+58 65+65 69+69 69+69 75+75 75+75 85+85 93+93 103+103 112+112 Power supply Phase/Frequency/Voltage Hz/V 3~/50/400 Notes: Performances are based on the following conditions: evaporator 12.2/6.7 C; ambient 46 C. unit at full load operation; operating fluid: water. Cooling only EWAD-MZPSB2 360 420 450 540 570 610 660 680 770 850 910 C10 H10 C11 Cooling capacity Nom. kw 337 390 443 501 534 579 617 656 727 794 850 935 977 1021 Tons 96 111 126 143 152 165 176 186 207 226 242 266 278 290 Power input Cooling Nom. kw 135 160 177 198 218 234 249 269 274 320 331 366 391 420 EER 2.50 2.44 2.50 2.53 2.45 2.47 2.48 2.44 2.65 2.48 2.57 2.55 2.50 2.43 IPLV 6.41 6.36 6.21 6.26 6.29 6.35 6.35 6.22 6.35 6.21 6.30 6.37 6.31 6.33 Dimensions Unit Height mm 2483 Width mm 2258 Depth mm 4983 4983 5883 5883 5883 6783 7783 7783 7783 7783 8820 9591 10461 11233 Weight Unit kg 4292 4292 4602 4800 4800 5072 5425 5425 6626 6542 6897 7175 7500 7500 Operation weight kg 4450 4450 4760 5055 5055 5327 5680 5680 6927 7027 7382 7660 7953 7953 Water heat exchanger Type Single pass shell & tube Water flow rate Cooling Nom. l/s 14.6 16.9 19.2 21.7 23.2 25.1 26.8 28.4 31.5 34.4 36.9 40.5 42.4 44.3 Water pressure drop Cooling Nom. kpa 54 67 55 53 59 36 41 45 64 44 49 56 43 46 Water volume l 158 158 158 255 255 255 255 255 301 485 485 485 453 454 Air heat exchanger Type Microchannel Compressor Type Inverter driven single screw compressor Quantity 2 Fan Type Direct propeller Quantity 10 10 12 12 12 14 16 16 16 16 18 20 22 24 Air flow rate Cooling Nom. l/s 49444 49444 59333 59333 59333 69222 79111 79111 79111 79111 89000 98889 108778 118667 Speed rpm 900 Sound power level Cooling Nom. dba 99 99 99 99 100 100 101 102 103 103 103 103 103 104 Sound pressure level Cooling Nom. dba 78 77 77 77 78 78 79 80 82 82 81 81 80 81 Operation range Air side Cooling Min.~Max. CDB 10~55 Water side Cooling Min.~Max. CDB -8~18-15~20 Refrigerant Type / GWP R134a / 1430 Circuits Quantity 2 Refrigerant charge Per circuit kg 32+32 32+32 37+37 40+40 40+40 45+45 48+48 48+48 52+52 52+52 59+59\ 65+65 72+72 78+78 TCO2eq 46+46 46+46 53+53 58+58 58+58 65+65 69+69 69+69 75+75 75+75 85+85 93+93 103+103 112+112 Power supply Phase/Frequency/Voltage Hz/V 3~/50/400 Notes: Performances are based on the following conditions: evaporator 12.2/6.7 C; ambient 46 C. unit at full load operation; operating fluid: water. 6

Notes 7

DATA CENTER APPLICATION PROCESS COOLING APPLICATION COMFORT COOLING Daikin Europe N.V. Naamloze Vennootschap Zandvoordestraat 300 8400 Oostende Belgium www.daikin.eu BE 0412 120 336 RPR Oostende (Responsible Editor) FSC ECPEN17-405 05/17 The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V. Printed on non-chlorinated paper.