MINI-SPLIT STANDARD CONDITIONERS SINGLE ZONE. Available styles

Similar documents
duct-free air conditioning systems Art cool inverter flex multi-split

ENGiNEERiNG AND SPECiFiCATioNS GuiDE

ENGiNEERiNG AND SPECiFiCATiONS GuiDE

LG Electronics, HVAC Division 920 Sylvan Ave., Englewood Cliffs, NJ

HIGH WALL DUCTLESS MINI-SPLIT STANDARD SINGLE ZONE

PRODUCT GUIDE Duct-Free Air Conditioning Systems Art Cool Mini-Split Flex Multi Split Floor Standing Ceiling Cassette Through-The-Wall PTAC PTHP

ART COOL MINI-SPLIT SINGLE ZONE. Neo Plasma. Outstanding air purification ART COOL. Customized good looks. Available styles and finishes

High Wall Duct-Free High Efficiency Single Zone

SUPPLY CO. LG PRICE SHEET

INSTALLER S GUIDE ART COOL SERIES FLOOR STANDING SERIES DUCT-FREE SPLIT AIR CONDITIONING SYSTEMS

Ductless Split Systems Ceiling Cassette Heat Pumps

DUCTLESS MINI-SPLITS SINGLE-ZONE HYPERTEK MULTI-ZONE

MINI-SPLITS SINGLE-ZONE HYPERTEK MULTI-ZONE

InverterFlex SerIeS InverterFlex Systems condition up to five rooms

InverterFlex SERIES InverterFlex Systems condition up to five rooms

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Ductless Split Systems Concealed Duct Heat Pumps

Packaged Terminal Air Conditioners

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Portable Vertical Air-Conditioning and Heating Systems

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

ductless mini-splits light commercial and multi-zone systems product catalog ALEGRIA ALEGRIA

SINGLE-ZONE CEILING-CONCEALED DUCTED SYSTEM ENGINEERING MANUAL

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

TECHNICAL SPECIFICATIONS

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

DUCTLESS MINI-SPLITS LIGHT COMMERCIAL AND MULTI-ZONE SYSTEMS PRODUCT CATALOG ALEGRIA ALEGRIA SERIES ALEGRIA

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

TECHNICAL SPECIFICATIONS

Fujitsu Condenser Model Number: AOU18RLXFZ, AOU18RLXFZH, AOU24RLXFZ, AOU24RLXFZH, AOU36RLXFZ, AOU36RLXFZ1, AOU48RLXFZ1.

HEAT PUMP INSTALLATION MANUAL

THE WORLD S MOST EFFICIENT HEAT PUMP

READ ONLY. American Standard Ductless Systems Product Catalog. A Comfortable, Convenient Solution Built To A Higher Standard.

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

Technical Product Guide

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

TECHNICAL SPECIFICATIONS

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

SUPERIOR COMFORT FOR THE GLOBAL MARKETPLACE

Mini-Split Single-Zone and Multi-Zone Air Conditioners and Heat Pumps. Residential Catalog 2018

HEAT PUMPS. Efficient Comfort For Every Season

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Lennox Mini-Split Systems Year-Round Comfort and Performance

Kühl J Series DUCTLESS ROOM AIR CONDITIONERS THE EXPERTS IN ROOM AIR CONDITIONING. Wall-mounted Ceiling Cassette The Insider Concealed Ducted

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

Single-Zone Four-Way Ceiling-Cassette System Engineering Manual

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

LG VRF Systems. Air Conditioning Technologies

Multi zone Two, Three, Four and Five Zones

2017 LINE UP MINI SPLITS CATALOG

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

Installation Instructions

Technical Product Guide

Cold Remedies. SamsungHVAC.com. Product Registration Required Conditions Apply

Ductless Split Air Conditioner

LONG LINE SET APPLICATION R-410A

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

Lennox 8 Series Single Zone - R-410A

S1CV/S1HV Single-Zone

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

2017 LINE UP MINI SPLITS CATALOG

LV Series. SEER 15+ Concealed Built in Heat Pump

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES

SLIM CONCEALED DUCT AIR CONDITIONING & HEATING SYSTEM INSTALLATION MANUAL. Models:

Ductless Split Systems Wall-mounted, Multizone Heat Pump

A single answer for multiple zones.

SECTION 50 - CAB CLIMATE CONTROL

A single answer for multiple zones.

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

T2CG/T2HG, T3CG/T3HG, T4CG/T4HG Multi-Zone

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

Feel the difference! Uncompromised Comfort Unrivaled Value C US. Mark of Superior Quality SERIES

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

Installation Manual BCS 1000/1500

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

Installation Manual BCS2000/3000

horizontal air discharge outdoor discus condensing unit

NFZP Variable Refrigerant Flow Guide Specification

Transcription:

MINI-SPLIT STANDARD AIR CONDITIONERS SINGLE ZONE Mini-Split Standard systems utilize the same duct-free technology as Art Cool units in a streamlined, low profile design. Models are available in a variety of sizes from 9,000 through 30,000 BTUs. LG s Mini-split standard air conditioners are easy to install, efficient and cost effective. Available styles Mini-Split Standard Indoor Unit White 9,000-24,000 BTUs Heat Pump Inverter White 30,000 BTUs MINI-SPLIT STANDARD Indoor Unit *9,000-24,000 BTUs units only Outdoor Unit 12

HIGH WALL DUCT-FREE MINI-SPLIT STANDARD SINGLE ZONE 9,000 BTUs LS092CE (A/C Model) 9,000 BTUs Cooling LS092HE (H/P Model) 9,800 BTUs Cooling 9,800 BTUs Heating Gold Fin Anti-corrosion Cooling mode Heating mode (H/P model only) Fan mode Auto operation Defrost control (H/P model only) Evaporator frost control Built-in low ambient standard, down to 0 F (cooling mode) has sufficient MEA #: 316-06-E System Model # LS092CE LS092HE Indoor Model # LSN092CE LSN092HE Outdoor Model # LSU092CE LSU092HE Capacity (BTUs) 9,000 9,800 9,800 SEER 13 13 Air Circulation (CFM H/M/L) 250/210/170 330/280/230 Fan Speeds 4/Auto/Chaos 4/Auto/Chaos Dehumidification (pts/hr) 2.6 3.0 Indoor db(a)* 36/31/28 41/36/34 Outdoor db(a)* 48 48 Rated Voltage Outdoor 115-60-1 115-60-1 Rated Voltage Indoor 36V DC 36V DC Indoor Dimensions 33 1/16 x 35 3/16 x W x H x D (inches) 10 5/8 x 11 5/8 x 6 1/32 6 1/2 Weight (lbs.) 15.4 20.5 Outdoor Dimensions 30 5/16 x 30 5/16 x W x H x D (inches) 21 5/16 x 21 5/16 x 9 5/8 9 5/8 Weight (lbs.) 66.1 72.8 Cooling / Heating ( F) 64-86 64-86/60-86 13 See page 18 for electrical specifications, refrigerant line requirements & formulas. See page 19 for installation materials.

HIGH WALL DUCT-FREE MINI-SPLIT STANDARD SINGLE ZONE 12,000 BTUs LS122CE (A/C Model) 11,500 BTUs Cooling LS122HE (H/P Model) 11,500 BTUs Cooling 11,500 BTUs Heating Gold Fin Anti-corrosion Cooling mode Heating mode (H/P model only) Fan mode Auto operation Defrost control (H/P model only) Built-in low ambient standard, down to 0 F (cooling mode) Evaporator frost control has sufficient MEA #: 316-06-E System Model # LS122CE LS122HE Indoor Model # LSN122CE LSN122HE Outdoor Model # LSU122CE LSU122HE Capacity (BTUs) 11,500 11,500 11,500 SEER 13 13 Air Circulation (CFM H/M/L) 330/280/230 330/280/230 Fan Speeds 4/Auto/Chaos 4/Auto/Chaos Dehumidification (pts/hr) 3.0 3.0 Indoor db(a)* 41/36/34 41/36/34 Outdoor db(a)* 48 48 Rated Voltage Outdoor 115-1-60 115-1-60 Rated Voltage Indoor 36V DC 36V DC Indoor Dimensions 35 3/16 x 35 3/16 x W x H x D (inches) 11 5/8 x 11 5/8 x 6 1/2 6 1/2 Weight (lbs.) 20.5 20.5 Outdoor Dimensions 30 5/16 x 30 5/16 x W x H x D (inches) 21 5/16 x 21 5/16 x 9 5/8 9 5/8 Weight (lbs.) 72.8 72.8 Cooling / Heating ( F) 64-86 64-86/60-86 See page 18 for electrical specifications, refrigerant line requirements & formulas. See page 19 for installation materials. 14

HIGH WALL DUCT-FREE MINI-SPLIT STANDARD SINGLE ZONE 18,000 BTUs LS182CE (A/C Model) 18,000 BTUs Cooling LS182HE (H/P Model) 19,500 BTUs Cooling 19,500 BTUs Heating Multi Power System Gold Fin Anti-corrosion Cooling mode Heating mode (H/P model only) Fan mode Auto operation Defrost control (H/P model only) Evaporator frost control has sufficient MEA #: 316-06-E System Model # LS182CE LS182HE Indoor Model # LSN182CE LSN182HE Outdoor Model # LSU182CE LSU182HE Capacity (BTUs) 18,000/17,800 19,500/19,000 19,500/19,000 SEER 13 13 Air Circulation (CFM H/M/L) 460/380/320 530/450/370 Fan Speeds 4/Auto/Chaos 4/Auto/Chaos Dehumidification (pts/hr) 5.3 6.6 Indoor db(a)* 41/38/36 46/41/38 Outdoor db(a)* 55 57 Rated Voltage Outdoor 230/208-60-1 230/208-60-1 Rated Voltage Indoor 36V DC 36V DC Indoor Dimensions 42 15/16 x 42 15/16 x W x H x D (inches) 11 13/16 x 11 13/16 x 7 1/32 7 1/32 Weight (lbs.) 28.6 28.6 Outdoor Dimensions 34 5/16 x 34 5/16 x W x H x D (inches) 25 13/16 x 31 1/2 x 12 5/8 12 5/8 Weight (lbs.) 149.9 169.6 Cooling / Heating ( F) 64-86 64-86/60-86 15 See page 18 for electrical specifications, refrigerant line requirements & formulas. See page 19 for installation materials.

HIGH WALL DUCT-FREE MINI-SPLIT STANDARD SINGLE ZONE 24,000 BTUs LS242CE (A/C Model) 22,500 BTUs Cooling LS242HE (H/P Model) 22,500 BTUs Cooling 22,500 BTUs Heating Multi Power System Gold Fin Anti-corrosion Cooling mode Heating mode (H/P model only) Fan mode Auto operation Defrost control (H/P model only) Evaporator frost control has sufficient MEA #: 316-06-E System Model # LS242CE LS242HE Indoor Model # LSN242CE LSN242HE Outdoor Model # LSU242CE LSU242HE Capacity (BTUs) 22,500/22,100 22,500/22,100 22,500/22,100 SEER 13 13 Air Circulation (CFM H/M/L) 530/450/370 530/450/370 Fan Speeds 4/Auto/Chaos 4/Auto/Chaos Dehumidification (pts/hr) 6.6 6.6 Indoor db(a)* 46/41/38 46/41/38 Outdoor db(a)* 57 57 Rated Voltage Outdoor 230/208-60-1 230/208-60-1 Rated Voltage Indoor 36V DC 36V DC Indoor Dimensions 42 15/16 x 42 15/16 x W x H x D (inches) 11 13/16 x 11 13/16 x 7 1/32 7 1/32 Weight (lbs.) 28.6 28.6 Outdoor Dimensions 34 5/16 x 34 5/16 x W x H x D (inches) 31 1/2 x 31 1/2 x 12 5/8 12 5/8 Weight (lbs.) 169.6 169.6 Cooling / Heating ( F) 64-86 64-86/60-86 See page 18 for electrical specifications, refrigerant line requirements & formulas. See page 19 for installation materials. 16

HIGH WALL DUCT-FREE MINI-SPLIT STANDARD SINGLE ZONE INVERTER 30,000 BTUs LS305HV (H/P Model) 27,000 BTUs Cooling 29,000 BTUs Heating Inverter Gold Fin Anti-Corrosion Self-cleaning indoor coil Auto changeover Cooling/Heating/Fan Mode Built-in low ambient standard, down to 14ºF (cooling mode) Defrost control Evaporator frost control Energy Saving has sufficient System Model # LS305HV Indoor Model # LSN305HV Outdoor Model # LSU305HV Capacity (BTUs) 27,000/27,000 29,000/29,000 SEER 16 Air Circulation (CFM H/M/L) 710/640/530 Fan Speeds 4/Auto/Chaos Dehumidification (pts/hr) 7.2 Indoor db(a)* 47/42/39 Outdoor db(a)* 58 Rated Voltage Outdoor 230/208-60-1 Rated Voltage Indoor 230/208-60-1 Indoor Dimensions 47 3/5 x W x H x D (inches) 13 3/5 x 8 1/4 Weight (lbs.) 37.5 Outdoor Dimensions 34 1/4 x W x H x D (inches) 31 1/4 x 12 3/5 Weight (lbs.) 147.7 Cooling / Heating ( F) 64-86 /60-86 17 See page 18 for electrical specifications, refrigerant line requirements & formulas. See page 19 for installation materials.

MINI-SPLIT STANDARD SINGLE ZONE ELECTRICAL & REFRIGERATION QUICK REFERENCE All equipment single phase. NOTE: Please see local electrical codes for proper wire specifications. Type System BTUs Voltage Rated MCA* MOP** Model Indoor Outdoor Amps Mini-Split A/C LS092CE 9,000 36V DC 115 7.0 15 15 Standard A/C LS122CE 11,500 36V DC 115 10.5 15 20 Single Zone A/C LS182CE 18,000 36V DC 230/208 8.6/9.5 15 20 A/C LS242CE 22,500 36V DC 230/208 11.5/12.5 20 30 H/P LS092HE 9,800 36V DC 115 10.5 15 20 H/P LS122HE 11,500 36V DC 115 10.5 15 20 H/P LS182HE 19,500 36V DC 230/208 11.5/12.5 20 30 H/P LS242HE 22,500 36V DC 230/208 11.5/12.5 20 30 H/P LS305HV 27,000/ 29,000 230/208 230/208 13.6/14.0 20 30 *Minimum Circuit Ampacity; **Maximum Overcurrent Protection; ***For LS182HE, LS242CE/HE Wire Size Minimum wiring requirements suggested by manufacturer. Minimum AWG 14-3 12-3*** Indoor/Outdoor Connecting Cable Minimum AWG 18-4 Refrigerant Line & Formula Specifications Type System BTUs Pipe Size Additional Max. length Max. Model Liquid Suction Refrigerant each pipe elevation Mini-Split A/C LS092CE 9,000 1/4" 3/8" 0.22 oz./ft. 50' 25' Standard A/C LS122CE 11,500 1/4" 1/2" 0.22 oz./ft. 50' 25' Single Zone A/C LS182CE 18,000 1/4" 1/2 " 0.22 oz./ft. 100' 50' A/C LS242CE 22,500 1/4" 5/8" 0.22 oz./ft. 100' 50' H/P LS092HE 9,800 1/4" 1/2" 0.22 oz./ft. 50' 25' H/P LS122HE 11,500 1/4" 1/2" 0.22 oz./ft. 50' 25' H/P LS182HE 19,500 1/4" 5/8" 0.22 oz./ft. 100' 50' Each system is pre-charged with enough refrigerant to charge 25 ft. of line and the interior unit. H/P LS242HE 22,500 1/4" 5/8" 0.22 oz./ft. 100' 50' H/P LS305HV 27,000/ 29,000 NOTE: Systems having the outdoor unit mounted above the (e.g. basement installations) have the following additional requirement: For systems with elevation of 25 ft. (see chart above and figure A), refrigerant lines must be oil trapped between 8 ft. and 16.4 ft. of elevation. For systems with elevation of greater than 25 ft. (see chart above), refrigerant lines must be oil trapped at least every 16.4 ft. of elevation. 1/4" 5/8" 0.22 oz./ft. 100' 50' OIL TRAP INDOOR UNIT OUTDOOR UNIT 25' maximum 8' minimum 16.4' maximum Figure A: Example of 25 ft. maximum elevation. 18

DUCT-FREE AIR CONDITIONERS LG INTERNET SALES POLICY Duct-Free Air Conditioning Products LG s expressed Duct-Free Air Conditioning warranty policy applies only to products sold and installed by qualified air conditioning contractors. Because products sold via the Internet cannot be assured of a quality installation by a qualified air conditioning contractor, LG s expressed warranty may not apply to internet sales. LG supports and recommends that a qualified air conditioning contractor properly size and install all LG Duct-Free Air Conditioning products for optimal performance and long life. FOR THE HVAC PROFESSIONAL INSTALLATION MATERIALS Don t forget to BUY Mounting screws and anchors (wall mount and ceiling cassette) Optional condensate pump (interior wall installation only) 1/2" condensate drain tubing Hose clamps Refrigerant line Correct electrical wire to connect indoor and outdoor units based on the LG model chosen (see electrical specifications) and local electrical code requirements Closed cell insulating tubing for liquid and suction lines tape Condenser mounting pad Disconnect and wiring for condenser unit Plastic duct and installation hardware to conceal connecting tubing on exterior walls Anchor bolts (optional for floor standing) Don t forget to BRING Level gauge 2 3/4" hole core drill Flaring tool set Gas leak detector Vacuum pump Gauge manifold Micron gauge R-410A Service Port Adapter REMEMBER THESE OTHER INSTALLATION ITEMS TO CONSIDER Low Ambient Wiring Kit #ICM 326H Low Voltage Condensate Pump. *24V Condensate Pumps available from Aspen Pumps by calling 732-248-8066 Wireless Wall Thermostat for Duct Free Systems Part # DFSWLWT0A See page 36 for more details *LG is not responsible for improper installation. Recommended source for 18/4 Stranded Shielded Wire required for LG s Duct-Free units (to order call 800-322-3660) 19