R-410A Ductless Split Systems. Single Zone, Dual Zone & Multi Zone Air Conditioners & Heat Pumps. Chilled Water Fan Coils

Similar documents
R-410A DUCTLESS SPLIT SYSTEMS. Single Zone, Dual Zone & Multi Zone Air Conditioners and Heat Pumps

comfort where it counts Variable Speed Ductless Split Systems Single Zone Air Conditioners / Heat Pumps

Ductless Series Variable Speed Split Systems

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Specifications and Performance S2H

EMI ENGINEERING SUBMITTAL

EMI ENGINEERING SUBMITTAL

T2CG/T2HG, T3CG/T3HG, T4CG/T4HG Multi-Zone

Specifications and Performance

Specifications and Performance

R21C Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R21C. Straight Cooling Nominal Capacities

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

R22C/H Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort

Divisions of ECR International, Inc. Commercial Zone-Comfort Solutions

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Single and Multi-Zone Ductless Split Systems

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

MAC-120HE-03 Air-Cooled Chiller

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Presents. Variable Speed Heat Pump Ductless Split Systems

Commercial High-Efficiency Condensing Units

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

CM R-410A High Efficiency Water Source Heat Pump

TECHNICAL SPECIFICATIONS

Commercial High-Efficiency Condensing Units

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

Product Specifications. Vertical Floor Consoles By First Co.

Wall Mounted Air Conditioners with Gas Heat Models AVGA

Specifications and Performance

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

The most energy-efficient commercial split system* Commercial Air Conditioners and Heat Pumps SSB/SPB Models

September, Ductless Split Ceiling Cassette Ductless Mini-Split Models SSD, SSH and SCW

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

Product Data. Features/Benefits. AIRSTREAM 42WKN08-36 Hydronic Ceiling Cassettes

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

VertiCool Aurora Engineering Guide

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

General Description. Operation

S1CV/S1HV Single-Zone

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

R11C R12C R21C R22C/H R23C/H R24C/H

VariCool VAV Engineering Guide

Split System Heat Pumps

CHP/CCP CEILING MOUNTED AIR HANDLER (ALL CAPACITIES) BACK TO INDEX ITEM QTY. DESCRIPTION

Heat Pumps COMFORT NEED IT. When You

13 GEP A L P - 1 A

MAC N-407 Air-Cooled Chiller

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

Enviromaster International LLC 5780 Success Dr. Rome, NY Nominal Capacities: 30,000-36,000 Btuh

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

T-Class AC and HP Units Up to SEER and 9.0 HSPF. Commercial Air Conditioners and Heat Pumps. True performance and rugged durability

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Model: Ceiling Cassette V 9k-24k

The XP21 raises the bar for efficiency and comfort.

Single - Zone Systems

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

50TM COMBINATION HEATING/COOLING UNITS

Nominal Circuit Capacities: WLH 9,000, 12,000, 18,000, 24,000 Btuh and WLC (only) 30,000 & 36,000 Btuh

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Multi - Zone Systems. Specification and Performance. 208V-230V 18k-36k. Presents

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

62DA,DB,DC,DD,DE,DF07-38

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Indoor Air Handlers with Compressors MVS and MVW

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

R4H4. Product Specifications

SKYPAK II, 3 Ton Series, gives you a

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

True performance and rugged durability. Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 16.2 SEER

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

R4H4. Product Specifications

Condensing Units CUS 15-60

Transcription:

R-410A Ductless Split Systems Single Zone, Dual Zone & Multi Zone Air Conditioners & Heat Pumps Chilled Water Fan Coils

R-410A Ductless Split Systems The EMI Ductless Advantage EMI s Ductless line is specifically designed to meet the needs of the North American HVAC market. With exceptional performance, operating efficiency, and EMI exclusive features EMI Ductless is the number one choice for Comfort Where It Counts. Benefits to Specifying Engineers A wide selection of wall, cassette and universal air handlers from 9000-36000 BTUH allows for specification of residential and commercial applications. AHRI Certification ensures performance standards are met. Independent circuits on multi zone units allow for simultaneous cooling or heating, along with zone isolation. Optional electric heat ensures occupants are comfortable. Peace of Mind All EMI systems feature a 1-year parts and 5-year compressor warranty with additional 5 and 10 years parts and labor Comfort Plus Extended Warranties available. Benefits to Contractors Designed for the North American market with low voltage interconnect, indoor mounted expansion device and 24 volt thermostat capability allowing for easy installations. Factory installed integral condensate pump on cassettes and field installed accessory pump with wall or universal air handlers with simple electrical connections uncomplicates condensate removal. Troubleshooting is made easy with simplified controls, easy access shrader ports and brass service valves. Refrigerant line lengths up to 100 feet allow for flexibility with equipment location. Benefits to Owners All units can be operated by a conventional 24 volt wall thermostat. Enhanced comfort with optional electric heat. Environmentally friendly R-410A refrigerant is not affected by phase out laws. EMI Ductless systems feature choice of unit mount digital controls, hand-held infra-red remote controls or 24-volt wall mount thermostats. 2

R - 4 1 0 A M U LT I Z O N E F L E X I B I L I T Y Standard Comfort Features: Simple operation with unit mounted digital control Fan cycling virtually eliminates variations in room temperature Electric heat available on all units (see charts for details) Standard Installation and Service Features: Simple electrical connections for condensate pump for the UNC/UNH and WLC/WLH Integral condensate drain overflow switch S I N G L E Z O N E ONE Condenser with choice of ONE Air Handler style and capacity tailored to a one zone heating or cooling application M U LT I Z O N E ONE Condenser with up to FOUR independent circuits, with individual Air Handler styles and capacities tailored to each zone 3

A I R H A N D L E R S Wall Air Handler Wall Air Handlers WLC Series Cooling (30,000-36,000 BTUH, 8.8-10.5 kw) WLH Series Cooling & Heat Pump (9,000-24,000 BTUH, 2.6-7.0 kw) NOMINAL NOMINAL OPTIONAL MODEL COOLING HEATING ELECTRIC HEAT CAP. BTUH, (kw) CAP. BTUH, (kw) (208/230V) WLHG09 9,000 (2.6) 9,000 (2.6) 3 kw WLHG12 12,000 (3.5) 11,400 (3.3) 3 kw WLHG24 18,000/23,800 (5.3/7.0) 17,600/20,800 (5.2/6.1) 3 or 5 kw WLCG30 28,200 (8.3) N/A 5 kw WLCG36 33,600 (9.8) N/A 5 kw Cassette Air Handler Added Features Include: Sweep function on louvers provides a wide cooling area Dry mode allows for dehumidification, with minimal change in room temperature (requires electric heat) Selectable filter indicator notifies occupant when cleaning is required Condensate pump accessory includes integral safety switch with 48" (1.2 m) available lift Test mode overrides controls for easy start-up and diagnostics Optional wall thermostat or handheld IR control Cassette Air Handlers CAC Series Cooling (30,000-36,000 BTUH, 8.8-10.5 kw) CAH Series Cooling & Heat Pump (9,000-24,000 BTUH, 2.6-7.0 kw) NOMINAL NOMINAL OPTIONAL MODEL COOLING HEATING ELECTRIC HEAT CAP. BTUH, (kw) CAP. BTUH, (kw) (208/230V) CAHJ09/CAHK09 9,000 (2.6) 8,200 (2.4) 1.5 kw CAHJ12/CAHK12 12,000 (3.5) 10,600 (3.1) 1.5 kw CAHG24/CAHH24 18,000/24,000 (5.3/7.0) 16,400/20,400 (4.8/6.0) 3.0 kw CACG36/CACH36 30,000/36,000 (8.8/10.5) N/A 5.0 kw Added Features Include: Factory installed condensate pump includes integral safety switch with 36" (0.9 m) available lift Controls accept 24V wall thermostat Easily configured for fresh air intake and up to 2 branch discharge locations Motorized discharge vanes on CAHG/H24 and CACG/H36 Infra-red compatible remote control with test mode CAC(H,K)/CAH(H,K) models Selectable filter indicator notifies occupant when unit needs filter cleaning CAC(H,K)/CAH(H,K) 4

A I R H A N D L E R S Comfort Where It Counts. Universal Ceiling & Universal Floor Mount Air Handlers UNC Series Cooling (30,000-36,000 BTUH, 8.8-10.5 kw) UNH Series Cooling & Heat Pump (9,000-24,000 BTUH, 2.6-7.0 kw) Universal Ceiling Air Handler NOMINAL NOMINAL OPTIONAL MODEL COOLING HEATING ELECTRIC HEAT CAP. BTUH, (kw) CAP. BTUH, (kw) (208/230V) UNHG09 9,000 (2.6) 9,000 (2.6) 3 kw UNHG12 12,000 (3.5) 11,200 (3.3) 3 kw UNHG24 18,000/23,800 (5.3/7.0) 17,600/20,800 (5.2/6.10) 3 or 5 kw UNCG30 28,200 (8.3) N/A 5 kw UNCG36 33,600 (9.83) N/A 5 kw Added Features Include: Single unit can be used in either a ceiling or floor mount application Multiple drain pans are factory installed, no field modification required Dry mode allows for dehumidification, with minimal change in room temperature (requires electric heat) Test mode overrides controls for easy start-up and diagnostics Selectable filter indicator notifies occupant when cleaning is required Plastic filter grille standard, optional metal grille available Easily configured for fresh air intake Optional wall thermostat or handheld IR control Condensate pump accessory includes integral safety switch with 48" (1.2 m) or 144" (3.6 m) available lift Universal Floor Mount Air Handler 5

C O N D E N S E R S Single Zone Condensers Single Zone S1C Series Cooling (9,000-36,000 BTUH, 2.6-10.5 kw) Single Zone S1H Series Heat Pump (9,000-24,000 BTUH, 2.6-7.0 kw) SIDE DISCHARGE CONDENSERS SINGLE ZONE MODEL NUMBER NOMINAL COOLING NOMINAL HEATING OF CIRCUITS CAP. BTUH, (kw) CAP. BTUH, (kw) S1CG9000/S1HG9000 1 9,000 (2.6) 9,000 (2.6) S1CG2000/S1HG2000 1 12,000 (3.5) 11,400 (3.3) S1CG8000/S1HG8000 1 18,000 (5.2) 17,600 (5.2) S1CG4000/S1HG4000 1 24,000 (7.0) 20,800 (6.1) S1CG3000 1 30,000 (8.8) N/A S1CG6000 1 36,000 (10.5) N/A Side Discharge Condenser Hail Guard/ Wind Baffle Accessory Service & Refrigerant Line Connections Comfort Features: Standard cooling operation down to 60 F (15 C) outside temperature Standard heat pump operation down to 0 F (-18 C) outside temperature Application flexibility with 100' (30.5 m) of interconnect refrigerant piping, supporting 35' (10.6 m) of elevation difference on 18,000 to 36,000 units, and 50' (15.2 m) of piping supporting 20' (6.1 m) of elevation on 9,000 and 12,000 units Side discharge cabinet with durable injection molded base and enclosed compressor compartment for reduced noise Coil ground clearance of 12" (0.3 m) provides added protection from the environment year round Front access to key components for ease of service Environmentally friendly R-410A refrigerant Easy access connections for refrigerant gauges Corrosion resistant, powder-coated steel cabinet with PVC coated wire guard coil protection One year parts, five year compressor warranty Options: Low Ambient kits - field installed for operation down to 32 F (0 C) or 0 F (-18 C) Hard Start Kit - assists compressor start-up under abnormal conditions such as low voltage (standard on heat pumps) 115V (9,000 12,000 BTUH, 2.6 3.5 kw) Consult factory for availability Copper/Copper coils (sea coast use) Condenser coil corrosion protection coating Hail Guard/Wind Baffle/Architectural Louver 6

C O N D E N S E R S Comfort Where It Counts. Dual Zone Side Dischar ge Condensers Dual Zone S2C Series Cooling (18,000-24,000 BTUH, 5.2-7.0 kw) Dual Zone S2H Series Heat Pump (18,000-24,000 BTUH, 5.2-7.0 kw) DUAL ZONE MODEL NUMBER NOMINAL COOLING NOMINAL HEATING OF CIRCUITS CAP. BTUH, (kw) CAP. BTUH, (kw) S2CH9900 2 18,000 (5.3) NA S2CH9200 2 21,000 (6.1) NA S2CH2200 2 24,000 (7.0) NA S2HH9900 2 18,000 (5.3) 17,400 (5.1) S2HH9200 2 21,000 (6.1) 19,200 (5.6) S2HH2200 2 24,000 (7.0) 21,000 (6.1) Side Discharge Condenser Comfort Features: Standard cooling operation down to 60 F (15 C) outside temperature Standard heat pump operation down to 0 F (-18 C) outside temperature Application flexibility with 50' (15.2 m) of interconnect refrigerant piping, supporting 20' (6.1 m) of elevation difference Side discharge cabinet with durable injection molded base and enclosed compressor compartment for reduced noise Coil ground clearance of 12" (0.3 m) provides added protection from the environment year round Front access to key components for ease of service Environmentally friendly R-410A refrigerant Easy access connections for refrigerant gauges Corrosion resistant, powder-coated steel cabinet with PVC coated wire guard coil protection Dual zone condensers and heat pumps have fully independent circuits with compressors on each circuit One year parts, five year compressor warranty Options: Low Ambient kits - field installed for operation down to 32 F (0 C) or 0 F (-18 C) Hard Start Kit - assists compressor start-up under abnormal conditions such as low voltage (standard on heat pumps) Copper/Copper coils (sea coast use) Condenser coil corrosion protection coating Hail Guard/Wind Baffle/Architectural Louver Hail Guard/ Wind Baffle Accessory Independent Refrigerant Circuits Service & Refrigerant Line Connections 7

C O N D E N S E R S Top Dischar ge Multi Zone Condenser s T2C, T3C & T4C Series Cooling (27,000-48,000 BTUH, 7.9-14 kw) T2H, T3H & T4H Series Heat Pump (27,000-48,000 BTUH, 7.9-14 kw) SYSTEM CAPACITY GUIDE Example: T2CG9800 Zone 1 Zone 2 Zone 3 Zone 4 9 8 0 0 Individual Zone Capacity: MULTI ZONE NUMBER NOMINAL NOMINAL MODEL OF COOLING CAP. HEATING CAP. CIRCUITS BTUH, (kw) BTUH, (kw) T2CG9800/T2HG9800 2 27,000 (7.9) / 27,000 (7.9) NA / 25,000 (7.3) T2CG8800/T2HG8800 2 36,000 (10.6) / 36,000 (10.6) NA / 33,000 (9.7) T2CG2400/T2HG2400 2 35,800 (10.5) / 35,800 (10.5) NA / 32,400 (9.5) T2CG4400/T2HG4400 2 47,500 (13.9) / 47,500 (13.9) NA / 44,000 (12.9) T3CG9990/T3HG9990 3 27,000 (7.9) / 27,000 (7.9) NA / 25,500 (7.5) T3CG9920/T3HG9920 3 30,000 (8.8) / 30,000 (8.8) NA / 27,400 (8.0) T3CG2220/T3HG2220 3 36,000 (10.6) / 36,000 (10.6) NA / 31,200 (9.1) T3CG9980/T3HG9980 3 36,000 (10.6) / 36,000 (10.6) NA / 33,500 (9.8) T3CG2240/T3HG2240 3 47,500 (13.9) / 47,500 (13.9) NA / 42,800 (12.5) T4CG9999/T4HG9999 4 36,000 (10.6) / 36,000 (10.6) NA / 34,000 (10.0) T4CG9992/T4HG9992 4 39,000 (11.4) / 39,000 (11.4) NA / 35,900 (10.5) T4CG9922/T4HG9922 4 42,000 (12.3) / 42,000 (12.3) NA / 37,800 (11.1) T4CG2222/T4HG2222 4 48,000 (14.1) / 48,000 (14.1) NA / 41,500 (12.1) 9 = 9,000 2 = 12,000 8 = 18,000 4 = 24,000 Empty Zone = 0 See Model Numbers for Specific Offerings Comfort Features: Standard heating operation down to 0 F (-18 C) outside temperature for T2H, T3H and T4H Standard cooling operation down to 60 F (15 C) outside temperature for T2C, T3C and T4C Up to 4 fully independent circuits Enhanced reliability with a compressor on each refrigerant circuit Application flexibility with 100' (30.5 m) of interconnect refrigerant piping, supporting 35' (10.6 m) of elevation difference on 18,000 to 24,000 circuits, and 50' (15.2 m) of piping, supporting 20' (6.1 m) of elevation on 9,000 and 12,000 circuits Environmentally friendly R-410A refrigerant Easy access connections for refrigerant gauges Corrosion resistant, powder-coated steel cabinet with PVC coated wire guard coil protection One year parts, five year compressor warranty Options: For T2C/T2H units, 2 circuits with nominal capacity choices of 9,000, 12,000, 18,000 and 24,000 BTUH (2.6, 3.5, 5.2 and 7.0 kw) are available For T3C/T3H units, 3 circuits with nominal capacity choices of 9,000, 12,000, 18,000 and 24,000 BTUH (2.6, 3.5, 5.2 and 7.0 kw) are available For T4C/T4H units, 4 circuits with nominal capacity choices of 9,000 and 12,000 BTUH (2.6 and 3.5 kw) are available Low Ambient Kit - field installed for operation down to 32 F (0 C) outside temperature (T2C, T3C, T4C only) Hard Start Kit - assists compressor start-up under abnormal conditions such as low voltage (T2C, T3C, T4C only) Condenser Coil Corrosion Protection Coating Copper/Copper coils (sea coast use) Hail Guard/Wind Baffle/Architectural Louver 8

CHILLED WATER FAN COILS CAF Chilled Water Cassette Air Handler (8,000-36,000 Btuh, 2.6-10.5 kw) Comfort Features: Factory installed condensate pump with 30" lift Easily configured for fresh air or remote discharge with knockouts Four way motorized discharge vanes sweep large area (18 36 models) Hot water coils available on all units except 12,000 Btuh Comfort Where It Counts. CAF Chilled Water Cassette Air Handler Options & Accessories: 24V remote wall thermostat Infrared Microprocessor Control Optional electric heat CAF CHILLED WATER CASSETTE CAPACITIES COOLING CAPACITY CHILLED WATER INLET/OUTLET F MODEL AIR ON F 40/50 F 45/55 F DB/50% RH TOTAL CAPACITY SENSIBLE CAPACITY FLOW P.D. FT. TOTAL CAPACITY SENSIBLE CAPACITY FLOW P.D. FT. BTUH/kW BTUH/kW GPM H20 BTUH/kW BTUH/kW GPM H20 72 5460 (1.6) 5460 (1.6) 1.2 6.7 4780 (1.4) 4440 (1.3) 1.1 5.4 08 75 6480 (1.9) 6140 (1.8) 1.4 9.0 5460 (1.6) 5460 (1.6) 1.2 6.4 80 9550 (2.8) 7170 (2.1) 2.1 17.0 7500 (2.2) 6480 (1.9) 1.7 11.7 72 7850 (2.3) 7510 (2.2) 1.7 4.3 6480 (1.9) 6140 (1.8) 1.4 2.7 12 75 10580 (3.1) 8190 (2.4) 2.3 6.7 8190 (2.4) 7510 (2.2) 1.8 4.0 80 14670 (4.3) 9550 (2.8) 3.3 12.0 12280 (3.6) 8530 (2.5) 2.7 8.7 72 13480 (4.0) 12520 (3.7) 2.7 3.7 10100 (3.0) 10100 (3.0) 2.0 2.2 18 75 17310 (5.1) 13850 (4.1) 3.5 5.8 11670 (3.4) 11640 (3.4) 2.3 3.0 80 23410 (6.9) 15870 (4.7) 4.7 9.0 17810 (5.2) 13780 (4.0) 3.6 6.0 72 15050 (4.4) 14570 (4.3) 3.0 4.6 11670 (3.4) 11630 (3.4) 2.3 3.0 20 75 19140 (5.6) 15930 (4.7) 3.8 6.4 13510 (4.0) 13470 (3.9) 2.7 3.7 80 26650 (7.8) 18390 (5.4) 5.3 11.1 19990 (5.9) 15970 (4.7) 4.0 6.8 72 26310 (7.7) 21260 (6.2) 5.3 8.5 17610 (5.2) 17570 (5.1) 3.5 5.3 33 75 32070 (9.4) 23500 (6.9) 6.4 13.0 23060 (6.8) 19790 (5.8) 4.6 7.4 80 41760 (12.2) 26920 (7.9) 8.4 19.2 33130 (9.7) 23300 (6.8) 6.6 14.2 72 28490 (8.3) 23300 (6.8) 5.7 10.3 19210 (5.6) 19170 (5.6) 3.8 6.0 36 75 34700 (10.2) 25690 (7.5) 6.9 15.1 24910 (7.3) 21700 (6.4) 5.0 8.1 80 45810 (13.4) 29480 (8.6) 9.2 21.0 35830 (10.5) 25450 (7.5) 7.2 15.7 OPTIONAL ELECTRIC HEAT (208/230V) 1.5 kw 3.0 kw 5.0 kw CAF HOT WATER CASSETTE CAPACITIES HEATING CAPACITY HOT WATER INLET/OUTLET F (HOT WATER 180 F INLET/160 F OUTLET) MODEL AIR ON F DB/50% RH TOTAL CAPACITY FLOW BTUH/kW GPM P.D. FT. H20 50 19800 (5.8) 2 10.0 08 60 17100 (5.0) 1.7 8.4 70 14000 (4.1) 1.4 6.7 50 46060 (13.5) 4.7 10.9 18/20 60 41930 (12.3) 4.3 9.4 70 37770 (11.1) 3.8 8.1 50 62500 (18.3) 6.4 10.8 33/36 60 56940 (16.7) 5.8 9.2 70 51350 (15.0) 5.2 7.3 9

CHILLED WATER FAN COILS CCP Chilled Water Ceiling Mounted Air Handler CCP Chilled Water Ceiling Mounted Air Handler (9,000-48,000 Btuh, 2.6-14.1 kw) Comfort Features: Standard 24V control Fresh air intake Options & Accessories: Infrared thermostat with hand held remote Condensate Pump (field installed) Chilled Water Control Valve (field installed) Wiring for normally closed/power open valve (24V ac, 20VA max. or 8VA max. on units with condensate pumps) Open wire electric heaters in all sizes (all with automatic reset high temperature cutout and redundant high temperature fuse link) Hydronic heat coil with sweat connections (consult factory) CCP CHILLED CEILING MOUNTED CAPACITIES COOLING CAPACITY MODEL 09/12 18/24 24/30 36/42, 48 ALL CAPACITIES BASED ON HIGH SPEED FAN AND 80 F DRY BULB / 67 F WET BULB ENTERING AIR TEMP. TOTAL CAPACITY SENSIBLE CAPACITY FLUID FLUID P.D. FT. BTUH/kW BTUH/kW TEMP. FLOW H20 7800 (2.3) 7300 (2.1) 45 1 3.0 10900 (3.2) 8800 (2.6) 45 2 5.3 13300 (3.9) 9800 (2.9) 45 3 8.8 9000 (2.6) 7800 (2.3) 40 1 3.0 12700 (3.7) 9500 (2.8) 40 2 5.3 15600 (4.6) 10700 (3.1) 40 3 8.8 17400 (5.1) 15000 (4.4) 45 3 3.4 22500 (6.6) 17200 (5.0) 45 5 10.1 19000 (5.6) 15100 (4.4) 40 3 3.4 26600 (7.8) 19700 (5.8) 40 5 10.1 21600 (6.3) 17000 (5.0) 45 3 4.8 26750 (7.8) 19500 (5.7) 45 4.5 10.2 29500 (8.6) 20600 (6.0) 45 6 17.2 25000 (7.3) 18600 (5.5) 40 3 4.8 31000 (9.1) 21500 (6.3) 40 4.5 10.2 35000 (10.3) 23000 (6.7) 40 6 17.2 34512 (10.1) 28430 (8.3) 45 4 6.4 42872 (12.6) 32080 (9.4) 45 6 13.3 47364 (13.9) 33977 (10.0) 45 8 22.6 39081 (11.5) 30341 (8.9) 40 4 6.4 49981 (14.6) 35067 (10.3) 40 6 13.5 56292 (16.5) 37832 (11.1) 40 8 22.8 OPTIONAL ELECTRIC HEAT (208/230V) 3.0 kw 5.0 kw 7.0 kw CCP HOT WATER CEILING MOUNTED CAPACITIES HEATING CAPACITY SINGLE STAGE HEATING ONLY 10 MODEL EWT F TOTAL CAPACITY BTUH/kW FLOW GPM P.D. FT. H20 09/12 140 14500 (4.2) 2 3.4 180 22900 (6.7) 2 3.4 18/24 140 27200 (8.0) 4 5.2 180 43200 (12.7) 4 5.2 30 140 29800 (8.7) 4 5.2 180 47300 (13.9) 4 5.2 36/42, 48 140 40300 (11.8) 4 6.1 180 64100 (18.8) 4 6.1

CHILLED WATER FAN COILS WCP Chilled Water High Wall Air Handler (9,000-30,000 Btuh, 2.6-8.8 kw) Comfort Features: Relays and connections for chilled water supply Unit mounted digital controls as standard: Large 3/4" LCD display Anti-short cycle protection Fan purge (fan remains on for 60 seconds after heat/cool call dropped for improved efficiency) Auto/high/low fan operation Low volt transformer Comfort Where It Counts. WCP Chilled Water High Wall Air Handler Options & Accessories: Hand held infrared remote controller (a separate hand held remote controller used to command the on-board controls) Field installed condensate pump 24V remote thermostat with controls and relays Chilled water control valve (N/C 24V ac, 20VA max. or 8 VA max. on units with condensate pumps) Electric heat with automatic reset high temperature cutout and redundant high temperature fuse link WCP CHILLED HIGH WALL CAPACITIES COOLING CAPACITY MODEL 09/12 15/18 24/30 ALL CAPACITIES BASED ON HIGH SPEED FAN AND 80 F DRY BULB / 67 F WET BULB ENTERING AIR TEMP. TOTAL CAPACITY SENSIBLE CAPACITY FLUID FLUID P.D. FT. BTUH/kW BTUH/kW TEMP. FLOW H20 7375 (2.2) 6732 (2.0) 45 1 0.8 10801 (3.2) 8272 (2.4) 45 2 3.8 13270 (3.9) 9279 (2.7) 45 3 8.0 8387 (2.5) 7189 (2.1) 40 1 0.8 12481 (3.7) 8950 (2.6) 40 2 3.9 15643 (4.6) 10304 (3.0) 40 3 8.1 15624 (4.6) 13477 (3.9) 45 2 4.4 19761 (5.8) 15367 (4.5) 45 3 9.1 17724 (5.2) 14379 (4.2) 40 2 4.5 23073 (6.8) 16763 (4.9) 40 3 9.3 20563 (6.0) 17564 (5.1) 45 3 2.3 29031 (8.5) 21178 (6.2) 45 6 8.3 32320 (9.5) 22539 (6.6) 45 9 17.7 23600 (6.9) 18887 (5.5) 40 3 2.4 34400 (10.1) 23423 (6.9) 40 6 8.4 38790 (11.4) 25351 (7.4) 40 9 17.9 OPTIONAL ELECTRIC HEAT (208/230V) 3.0 kw 5.0 kw 11

EMI and the Buy American Act ECR International manufactures ductless split system air conditioners in the United States under the EMI (Enviromaster) brand. The single and dual zone condensers, wall, cassette and universal air handlers when designated with a (-U) extension are manufactured in the Utica, New York facility. In addition, EMI s top discharge condensers are also manufactured in the Utica facility. These products comply with The American Recovery and Reinvestment Act under the manufactured goods portion of Section 1605, or as COTS (commercially off the shelf items). For complete product information, please refer to individual unit specifications, installation and operation manual, and other product literature. Due to on-going product development, specifications are subject to change without notice. Enviromaster International 2201 Dwyer Ave., Utica, NY 13501 Phone: 800-325-5479 Fax: 866-432-7329 E-Mail: emi@enviromaster.com Web: www.enviromaster.com Contractor Assistance: 800-325-5479 PN 240004840 Rev. 10/10