Phillips. HORIZONTAL AND VERTICAL ASSEMBLIES For Ammonia (R-717) and Halocarbon Refrigerants

Similar documents
PURGER INSTALLATION AND OPERATION BULLETIN PUR-SB17-02 SERVICE BULLETIN

Selection and Operational Considerations. Harold Streicher, Vice President Sales Hansen Technologies, Inc.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Liebert CSU3000 Chiller

.005 ATMOSPHERIC DEAERATOR

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

TECHNICAL. Series 18. Pump Packages

DEAERATORS .005 ATMOSPHERIC DEAERATOR

JCseries EVAPORATIVE CONDENSER. engineering data

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com

BuildingName The Description of the Project P DOCUMENTS

Circulating Water Temperature Controller

Precise Temperature Control; Compact Footprint

Landfill & Digester Gas Dryers. Features and Benefits

Central Chillers TS Series

.03 ATMOSPHERIC DEAERATOR

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Thermostatic expansion valves for ammonia Type TEA

Chapter-8 Capacity Control of Refrigeration Systems

Armstrong Flo-H2O Water to Water Instantaneous Heater Installation and Maintenance & Operation

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

LOW RECIRCULATION RATE EVAPORATORS

SECTION CENTRIFUGAL WATER CHILLERS

Silhouette. Feedwater Heater. Boiler Feedwater

AUTO-PURGER AP. Noncondensible Gas (Air) Refrigerant Purger. Model APW OPERATOR INSTALLATION & INSTRUCTION MANUAL

SECTION CENTRIFUGAL WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower

Multi-Institutional Academic Health Science & Research Center Evansville, IN

PACKAGED AIR COOLED Product Data Catalog

Back to basics. Setting HEVs for Liquid Overfed Evaporators. 13 th Annual IRC R&T Forum May 8-9, 2013

SECTION CHILLERS

Intelligent Refrigeration Solutions

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

USG Series. Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

Compressors, Chillers & Condensers

MCBV MOTOR CONTROLLED BALL VALVES

Call us today! (800)

Call us today! (800)

Call us today! (800)

CHILLED WATER SYSTEM 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

Chillers CA Series: 35º 55º LCT CF Series: 35º 55º LCT CE Series: 35º 55º LCT CLH Series: 15º -15º LCT CLM Series: -10º -70º LCT

LQ AQ SQ. Air-cooled and water-cooled portable chillers

Refrigeration and Air Conditioning Controls. Applications. PM Modulating pressure and temperature regulators REFRIGERATION AND AIR CONDITIONING

UNFIRED STEAM GENERATORS STANDARD EQUIPMENT

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days

SECTION HEATING BOILER FEEDWATER EQUIPMENT

Trouble Shooting Guide PWA, 3-phase (D10571)

RHP120 RHP300 Steam Boiler Series

(2) 325 tpd York Chlorine Liquefier Systems

Custom Design TYPE SHM Steel Horizontal Make-up Boiler Feed Pumps and Custom Design TYPE SHEM. BULLETIN 107 Revised 5/17

.2 Section Waste Management and Disposal.

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

IIAR Minimum Safety Criteria for a Safe Ammonia Refrigeration System

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

BASIL 6000 TUNNEL CAGE WASHER

SECTION 1 MOUNTING & PIPING INSTALLATION. INSTALLATION DIMENSIONS (MM) Figure 1

Condensate Return Feedwater Systems For Low and High Pressure Steam Boilers

Water Piping and Pumps

APPLICATION and INSTALLATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Temptek Auxiliary Equipment

4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions

Specifications, Applications, Service Instructions, & Parts. AUTO-PURGER PLUS, APPT Non-condensible Gas (Air) & Water Purger for Ammonia

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

Moss MOSS TRAY DEAERATOR ECONOMICAL INDUSTRIAL DEAERATOR SYSTEMS

PRODUCT GUIDE SPECIFICATIONS

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

SECTION ROTARY-SCREW WATER CHILLERS

LQ AQ SQ. Air-cooled and water-cooled portable chillers

Condensing Unit Installation and Operating Instructions

THE FOLLOWING CHANGES/ADDITIONS TO THE ABOVE CITED SOLICITATION ARE ANNOUNCED:

For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X. Air Cooled Medical Chiller Product Data Catalog

SECTION ROTARY SCREW WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower

Cutting Edge Compressor Technology

GENERAL CAPABILITIES

AUTO-PURGER M OPERATOR INSTALLATION & INSTRUCTION MANUAL. ENERGY SAVER Compact, Noncondensible Gas (Air) Purger ISO For 115V and 230V Models

1.2 REFERENCES - comply with the following codes and standards:

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

University of Delaware

OACS Outdoor Air-Cooled Central Chillers

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

In-Line Air Separators

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

REFRIGERATED AIR DRYERS

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

Transcription:

Phillips REFRIGERATION MECHANICAL PUMP RECIRCULATORS BULLETIN MPR-03E Engineering Data VALVES VESSELS SYSTEMS CONTROLS HORIZONTAL AND VERTICAL ASSEMBLIES For Ammonia (R-717) and Halocarbon Refrigerants Features One central vessel (accumulator) for all evaporators on a common suction system. Provides liquid slop-over protection for system compressor(s). Provides increased, efficient utilization of evaporator s internal coil surface for heat transfer. Liquid refrigerant feed to the evaporator(s) is insensitive to floating head pressure. Refrigerant oil that may find its way into the system s low side is transferred back to the low-pressure receiver via the defrost condensate and drained from the pressureprotected non-insulated oil drain pot. Description H. A. Phillips & Co. offers Horizontal and Vertical Liquid Recirculator Packaged Units for both ammonia and halocarbon refrigerants. These packages are factory assembled, pre-wired and pre-piped on a common structural steel base complete with: Accumulator: Suitably sized for given design criteria to maintain adequate separation velocity and dry gas velocity for compressor suction return. Vessels are ASME code designed, stamped and National Board registered. Pumps: Suitably sized to meet given system flow requirements as a function of required BTU removal, required bypass flow to meet minimum pump flow requirements and system head at liquid specific gravity. Centrifugal pumps are dual mounted with one serving as a standby. Pumps are supplied with TEFC motors, suction service valves, discharge stop/check service valves, bypass hand regulator valves and relief regulators, and volute vent valves. Visit us at: www.haphillips.com or e-mail us at: info@haphillips.com

Description (continued) Interconnecting Pipe, Valves and Fittings: H. A. Phillips & Co. packages are furnished with the required interconnecting refrigerant pipe, valves and fittings, including pump vent lines, volute vent lines, pump bypass lines, gauges, and gauge valves. Valves are low temperature steel construction. Pipe 2 and smaller is schedule 80. Pipe 2-1/2 through 10 is schedule 40. Pipe for applications 20 F and above is ASTM A106 GRADE B. For applications below 20 F, ASTM 333 GRADE 6 carbon steel pipe is used. Pipe joints 1-1/2 and smaller are socket welded with 3000# class, socket weld fittings. Pipe joints 2 and larger are butt welded with fittings compatible with the wall thickness of the pipe. Control Column: Column incorporates Phillips Level Eye, isolation valves with flanged unions, electronic probe, high liquid level float switch, and drain valve. Column and accessories are shipped loose. Oil Pot: A 300 psi ASME CODE oil pot is provided with a relief valve, return service valve, vent service valve, oil drain service valve, and a spring return oil drain valve. Control Panel: A NEMA 12 (460v power/120v control, 60 Hertz) pre-wired control panel is provided complete with the following: (1) Liquid pump starters with individual H-O-A switches (2) Main power disconnect (3) Individual pump PROOF RUN indicators (4) High and low level indicators with alarm (5) Operating liquid level indicator (6) Low level reset (7) Horn silence Optional Control Panel Features: (1) Variable frequency drive with PID and keypad (2) Individual pump motor amperage monitor/display (3) Probe controller (interfaced) (4) Individual pump suction pressure readout (5) Discharge liquid temperature readout (6) Individual pump heater control (7) Individual pump safety limit control Design Function Mechanically pumped liquid refrigerant overfeed systems are very prevalent in industrial ammonia refrigeration applications. These systems function through the use of a mechanical pump that circulates liquid refrigerant through the evaporator(s). The two-phase (liquid/vapor mixture) is then returned to and separated in a central low-pressure receiver (accumulator) with the dry vapor directed back to the compressor(s). An operating liquid refrigerant level is maintained (by liquid makeup) in the low-pressure receiver to replace liquid refrigerant that evaporated in the evaporator(s) by means of either electro-mechanical or electronic control devices. In some cases, the system may witness a greater liquid refrigerant flow rate than the load requires, consequently producing disproportionate two-phase flow (added pressure drop) in the liquid/vapor return line to the low-pressure receiver. page 2

Options Liquid Make-up Control (Sub-assembled or Shipped Loose) Conventional solenoid valve with strainer and hand expansion valve Phillips Modulating Liquid Level Control Danfoss AKVA electronic pulse-width valve Accumulator Pressure Surge Control Phillips Modulating Liquid Level Control Danfoss AKVA electronic pulse-width liquid level control valve Danfoss Variable Frequency Control Variable Frequency Drive: Saves Energy by varying the speed of the pump to provide only the flow required to meet the system refrigeration demands (no energy wasting proportional valves or bypass loops). Optimizes System Efficiency by maintaining constant discharge (head) pressure via built-in PID controller. Protects against pump cavitation and recirculation by continuously monitoring the pump motor current. Optional Features of Variable Frequency Drive: Power Loss Ride Stall Prevention Low and High Current Projection Overload Detection Overtorque Detection Thermal Overload Protection Low Input Line Harmonics Voltage Spike Protection UL/cUL Listed CE Marked Phase Loss Protection Short Circuit/Ground Fault Protection 4-Line LCD Display with the following data available: Output Frequency Run Hours Feedback Valve Motor Thermal Status Motor Current Drive Thermal Status Motor Torque Power (kw or HP) Output Energy (kwhr) Setpoint/Speed Reference (in %) DUAL MAKE-UP SINGLE MAKE-UP LIQUID MAKE UP CONTROL ORDERING INSTRUCTIONS Specify: (1) Model Number (2) Refrigerant (3) Capacity Requirement (TR) (4) Saturated Suction Temperature (5) Pressure Differential Required (PSID) (6) Recirculation Rate (7) Required Vessel Design Pressure (8) Required Surge Volume (9) Pump Selection (10) Required Electrical Characteristics (11) Optional Liquid Make-up Control (12) Optional Accumulator Pressure Surge Control (13) Optional Isolation Valves (14) Optional Variable Frequency Drive page 3

HORIZONTAL RECIRCULATOR ASSEMBLY A Outside Diameter B Overall Length C Base Width D Overall Height E Suction Return Connection LEGEND F Liquid/Vapor Return Connection G Liquid Make-up Connection H 1 H 2 I Oil Pot Drain Connection J 1 J 2 K Relief Connection L 1 L 2 M 1 Pump Vent Connection M 2 Pump Vent Connection N Oil Pot Vent Connection O Oil Pot P Oil Dome Reservoir A B C D E F G H I J K L M N HORIZONTAL RECIRCULATOR PACKAGE DIMENSIONS HORIZONTAL SURGE CAPACITIES & WEIGHTS DIAMETER SHELL LENGTH ONLY O.A.L. SURGE VOLUME* (CUBIC FT.) O (DIA. x LG.) APPROX. SHIPPING WT. (LBS.) PHR30 30 96 116 12.6 3400 PHR36 36 96 119 20 3800 PHR42 42 120 145 35 5300 PHR48 48 120 148 49 6500 PHR54 54 120 152 68 7300 PHR60 60 120 155 86 7800 PHR72 72 120 162 127 8900 PHR84 84 120 166 179 13,900 *Surge volume based on 75% of remaining volume above liquid level; volumes include 2:1 ellipsoidal heads. P (DIA. x LG.) PHR30 30 116 40 88 5 6 1 1-1/4 1 3 3/4 3/4 3/4 3/4 8 x 36 8 x 12 PHR36 36 119 40 94 5 6 1-1/4 1-1/4 1 4 3/4 3/4 3/4 3/4 8 x 36 8 x 12 PHR42 42 146 48 100 6 8 1-1/2 1-1/2 1-1/4 4 3/4 3/4 3/4 3/4 10 x 36 8 x 12 PHR48 48 149 48 108 6 8 1-1/2 1-1/2 1-1/4 4 3/4 3/4 3/4 3/4 10 x 36 10 x 12 PHR54 54 152 54 114 8 10 2 2 1-1/4 4 3/4 3/4 3/4 3/4 10 x 36 10 x 12 PHR60 60 155 60 120 8 10 2 2 1-1/4 6 1 1 1 1 10 x 36 12 x 12 PHR72 72 162 72 132 10 12 2-1/2 2 1-1/2 6 1-1/4 1 1 1 10 x 36 14 x 12 PHR84 84 168 84 144 12 14 3 2 1-1/2 8 1-1/4 1-1/4 1 1 12 x 36 16 x 12 Note: For packages with vessel diameters of 96"-144," please consult factory. These packages are custom designed for the application. Please Note: The dimensions and weights indicated are nominal and not for construction. H. A. Phillips & Co. will supply a dimension drawing. page 4

VERTICAL RECIRCULATOR ASSEMBLY A Outside Diameter B Overall Height (Shell) C Overall Height (Unit) D Base Width E Base Length F Liquid/Vapor Return Connection G Suction Return Connection H Liquid Make-up Connection I 1 I 2 LEGEND J 1 J 2 K Oil Pot Drain Connection L Relief Connection M Oil Pot Vent Connection N Pump Vent Connection O 1 O 2 P Oil Pot Q Perforated Plate P A B C D E F G H I J K L M N O (DIA. X LG.) PVR30 30 116 176 42 78 6 5 1 3 1-1/4 1 3/4 3/4 3/4 3/4 8 x 36 PVR36 36 119 179 54 78 6 5 1-1/4 4 1-1/4 1 3/4 3/4 3/4 3/4 8 x 36 PVR42 42 146 209 54 78 8 6 1-1/2 4 1-1/2 1-1/4 3/4 3/4 3/4 3/4 10 x 36 PVR48 48 149 211 72 78 10 8 1-1/2 4 1-1/2 1-1/4 3/4 3/4 3/4 3/4 10 x 36 PVR54 54 152 214 74 86 10 8 2 4 2 1-1/4 3/4 3/4 3/4 3/4 10 x 36 PVR60 60 155 217 74 86 12 10 2 6 2 1-1/4 1 1 1 1 10 x 36 PVR72 72 162 224 84 90 14 12 2 6 2 1-1/2 1-1/4 1 1 1 10 x 36 PVR84 84 168 230 84 96 16 14 2 8 2 1-1/2 1-1/4 1 1 1 12 x 36 VERTICAL RECIRCULATOR PACKAGE DIMENSIONS Note: For packages with vessel diameters of 96"-144," please consult factory. These packages are custom designed for the application. VERTICAL SURGE CAPACITIES & WEIGHTS DIAMETER SHELL LENGTH ONLY O.A.L. SURGE VOLUME* (CUBIC FT.) APPROX. SHIPPING WT. (LBS.) PVR30 30 96 116 15 3200 PVR36 36 96 119 20 3400 PVR42 42 120 145 43 5000 PVR48 48 120 148 52 6300 PVR54 54 120 152 64 7000 PVR60 60 120 155 85 7600 PVR72 72 120 162 135 8700 PVR84 84 120 166 183 12,000 *Surge volumes are based on area available in shell only. Head volumes not considered. Please Note: The dimensions and weights indicated are nominal and not for construction. H. A. Phillips & Co. will supply a dimension drawing. page 5

NOMINAL VERTICAL RECIRCULATOR CAPACITIES TONS OF REFRIGERATION EVAPORATOR TEMPERATURE ( o F) SINGLE STAGE* TWO STAGE** +30 o +20 o +10 o 0 o -10 o -10 o -20 o -30 o -40 o -50 o PVR24 140 130 110 100 90 100 90 70 60 50 PVR30 220 200 170 150 130 150 130 120 100 80 PVR36 320 290 250 230 200 230 200 170 150 110 PVR42 450 400 350 310 270 310 270 240 200 160 PVR48 570 520 450 410 360 410 350 310 270 210 PVR54 720 680 570 540 470 540 470 410 350 280 PVR60 900 850 710 660 580 670 580 510 430 340 PVR72 1340 1200 1080 940 810 940 820 720 610 190 PVR84 1780 1630 1400 1270 1140 1280 1120 980 830 660 PVR96 2320 2090 1830 1640 1500 1660 1280 1270 1080 850 PVR108 2910 2660 2320 2080 1830 2100 1830 1610 1370 1090 PVR120 3630 3320 2890 2600 2280 2620 2290 2010 1710 1360 PVR144 5230 4740 4170 3740 3290 3760 3280 2880 2450 1950 *Assumes 96 F liquid feed temperature. **Assumes 25 F max. liquid feed temperature. NOMINAL HORIZONTAL RECIRCULATOR CAPACITIES TONS OF REFRIGERATION EVAPORATOR TEMPERATURE ( o F) SINGLE STAGE* TWO STAGE** +30 o +20 o +10 o 0 o -10 o -10 o -20 o -30 o -40 o -50 o PHR24 115 110 95 85 70 80 70 60 50 40 PHR30 190 170 150 140 120 130 120 100 80 60 PHR36 295 270 240 190 170 200 170 145 120 100 PHR42 400 380 310 280 250 280 250 210 170 140 PHR48 540 490 430 360 320 365 320 270 220 180 PHR54 790 700 620 530 470 530 470 390 320 270 PHR60 980 880 790 650 580 650 580 480 400 320 PHR72 1400 1260 1110 940 830 940 830 700 570 470 PHR84 1960 1800 1600 1360 1180 1340 1190 1000 810 670 PHR96 2600 2370 2100 1760 1580 1760 1570 1310 1080 880 PHR108 3320 2980 3690 2240 1990 2240 1990 1670 1370 1120 PHR120 4110 3700 3300 2780 2450 2760 2460 2060 1690 1390 PHR144 5950 5320 4780 3990 3540 4000 3540 2980 2440 2000 *Assumes 96 F liquid feed temperature. **Assumes 25 F max. liquid feed temperature. PUMP CAPACITY REQUIREMENTS NH3 FLOW GPM PER TON OVERFEED EVAPORATOR TEMPERATURE ( o F) RATE 30 o 20 o 10 o 0 o -10 o -20 o -30 o -40 o -50 o 3 : 1.206.201.196.191.186.182.178.174.171 4 : 1.275.268.261.254.249.243.238.232.228 6 : 1.412.401.391.382.373.364.356.349.342 PUMP SPECIFICATIONS PUMP MAX GPM @ DESIGNATION 25 PSID PUMP HP 2CBS-2-4 20 2 2CBS-3-4 55 3 2CB-3-4 90 3 3CB-7 1/2-6 250 7 1/2 3CB-10-6 350 10 H. A. Phillips & Co. 1775 Wallace Avenue St.Charles, Illinois 60174-3402 U.S.A. Phone: (630) 377-0050 Fax: (630) 377-2706 E-mail: info@haphillips.com or visit us @ www.haphillips.com