SURFACE WARM CEILING HEATERS

Similar documents
Surface Warm Ceiling Heaters

Recessed Warm Ceiling Heaters

RECESSED WARM CEILING HEATERS MODELS HSRCH3000RF, HSRCH4500RF INSTALLATION AND OPERATING MANUAL

Commercial Fan Heater

MODELS HSCFH60WX, HSCFH90WX, HSCFH120WX

Instruction Manual WARNINGS

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

PHV-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

T-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Installation, operation and Maintenance Manual

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

OWNERS INSTRUCTION MANUAL

AIR CURTAIN HX RECESSED RANGE

INDEX WARNINGS AND RECOMMENDATIONS 2 COMPLIANCE DECLARATIONS 3 RANGE AND SIZES 3 ELECTRICITY SUPPLY 3 INSTALLATION 4 INSTRUCTIONS FOR UNINSTALLING

QUALITY SPACE HEATERS

air pump 2700/4500 ? 2YEAR GUARANTEE UK AIRPUMP _33435 CASC /10/ :16 Page 1

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

MRXBOX95-WALL. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Extract air.

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

POWER SHOWERS Models 4500M 5002M 4500T 5002T

Installation, operating and servicing instructions

ECOSMART TWINFANS. (EST-X/R/B) 1 phase, Direct Drive, Run & Standby For External, Roof Mounted and Internal use Installation and Maintenance

AIR CURTAIN T SURFACE MOUNTED RANGE

WYND DC 54 CEILING FAN Installation Manual

Lo-Carbon T-series Window & Roof Models

Vacuum Cleaner MC-E3003 MC-E3001. Operating Instructions. Model No.

Space Saver. Installation and user manual. Issue 001 March 2018 ENGLISH UK IRL SmithsEP.co.uk. Issue March 2018 smithsep.co.

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

AC500T, AC1000T, AC1500T, AC2000T

User, Installation and Servicing Instructions. Panther Static Hot Cupboards G1, G2 and G3 IS86 ECN1881


Cooker Hood CHIM60 CHIM70 CHIM90 CHIM101 CHIM110. Installation & User s instructions

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

INDOOR USE ONLY. Installation and Maintenance XTRACTOR. (ESX) 1 and 3 phase, Direct Drive, Fans for indoor use

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

Application and Installation Guide (excluding Solar Air Collectors)

Warnings, Safety Information and Guidance

ELECTRIC UNIT HEATER REGULAR DUTY

ELSTON 52 CEILING FAN

ECOSMART XTRACTOR. (ESX-X/R/B) 1 phase, Direct Drive For External, Roof Mounted and Internal use Installation and Maintenance.

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

Imperial Electric Fires

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz


PERFORMANCE SHOWER PRODUCTS

SLIM-LINE RC FAN CONVECTOR.

Installation, Operation and Maintenance Instructions Document Ref:

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE:

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

HI-LINE SUPER RC FAN CONVECTOR MODELS: 25-18,

TC MODULE (FFD) (with Gas Hob)

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

AGA TOTAL CONTROL. Model No s: TC3 & TC5 (ROOM VENT OPTION)

Simple. Smart. Solutions. ROOM PACK Z2105/239/0812. Step by Step Installation Guide

Copperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user

STEAM WALLPAPER STRIPPER MODEL HTW5

F6102 Installation & Operating Instructions for the Parrotuncle Owner s Installation,Manual WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER

Installation and Operating Manual Drying Cabinet

Please read and save these instructions. Should you have any questions or difficulty installing your fan, call us first!

>40 80 mm. Dishwasher EN Installation instructions. Appliance components >40. Recess for pipes >80. Front panel/decorative system.

Installation, Operation and Maintenance Instructions Document Ref:

AMBIRAD QUARTZ GLOW INSTANT INFRA-RED HEATERS INSTALLATION AND OPERATING MANUAL

Operating Instructions

HEAVY DUTY BRASS SHOWER PUMPS

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

Installation Instructions / Operating & Maintenance Manual Ablution Plant Model BTHW-1

HI-LINE LV FAN CONVECTOR MODEL: 7-4.

LUCCI AIRFUSION QUEST II CEILING FAN

Whole Room Dryer WRD, WRD/110

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

User and Installation Instructions. Opus 700 Electric Salamander Grill OE7304 IS318 ECN3011

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Installation, Operation & Maintenance Instructions Document Ref:

Whats in the box. NS1002-E Installation Guide Rev 1.0

Installation & User Instructions: Model: Arizona/Broadway/Corsano/Compton/Compton1000/Corbiere/Empire /Newark/Newark1000/Qube/Tribeca

INSTALLATION, OPERATION & MAINTENANCE MANUAL

OPTIMA RADIANT TUBE HEATING SYSTEMS. Operation, maintenance and servicing manual

THE QUALITY BRAND IN FANS

installation and operation manual for Hunter Ceiling Fans

SUTTON 52 CEILING FAN

Chapter 3 Cooling, heating and ventilation systems


THE QUALITY BRAND IN FANS

SERVICING AND BREAKDOWN...

AP-EH500-L/RQA9837. Installation Guide

User Guide. Please read carefully before use. Your Hoover Guarantee. Your Hoover Guarantee. Contents. IMPORTANT Safety Reminders

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

SUBMERSIBLE WATER PUMPS

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

SHORT WAVE INFRARED PANEL DRYER

Model 804. Chic, Envy, Mirage, Serenity or Twilight fascia.

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

TT302 (200W) Wireless receiver Pull cord Dimmer

Transcription:

SURFACE WARM CEILING HEATERS CATALOGUE NUMBERS HE7237, HE7247, HE7267, HE7237RF, HE7247RF, HE7267RF INSTALLATION AND OPERATING MANUAL INDEX Section General information ------------------------------------------------------------1 Dimensions ----------------------------------------------------------------------2 Installation Details --------------------------------------------------------------3 Electrical Connections --------------------------------------------------------4 Operation -------------------------------------------------------------------------5 Servicing & Maintenance -----------------------------------------------------6 Consort Equipment Products Limited Thornton Industrial Estate, Milford Haven Pembrokeshire, SA73 2RT Tel: 01646 692172 Fax: 01646695195 Mon to Fri 8.30 am to 3.30 pm Email: enquiries@consortepl.com Web: www.consortepl.com 1

1. General Information 1.1 Introduction CLAUDGEN Wireless controllers This instruction manual describes the CLAUDGEN Surface Warm Air Ceiling Heaters. The heater is designed to be suspended from the ceiling. 1.2 General All installations must be in accordance with the regulations in force in the country of use. These instructions must be handed to the user on completion of the installation. Installers and service engineers must be able to demonstrate competence and be suitably qualified in accordance with the regulations in force in the country of use. To ensure continued and safe operation it is recommended that the appliance is serviced annually. The heater outlet / inlet must not be obstructed during use. 1.5 Controller standard models The HE7237, HE7247, HE7267 heaters are supplied with a remote controller. The remote control unit houses 3 double pole 20A rocker switches. The heater can also be controlled remotely via BMS or any controls with contact rated at 20A for HE7237, HE7247 and 30A for HE7267. The controller is wired to the base unit via an appropriate sized cable specified by the current IEE standard. 1.3 Electrical Supply. Electrical supply is 230/240V single phase, Neutral and Earth. The maximum cable inlet size is 4mm². It is recommended that the electrical supply to the base unit in the heater is via an appropriate switched isolator in accordance with the regulations in force in the country of use and must be via a fused isolator having a contact separation of greater than 3mm on all poles. BMS control, time switches, room thermostats and door interlocks can be installed at the discretion and responsibility of the installer. All units must be wired in accordance with I.E.E regulations for the Electrical Equipment of Buildings and the installer should ensure that a suitable isolating switch is connected in the mains supply. 1.4 Controller `RF` models The HE7237RF, HE7247RF, HE7267RF heaters are supplied without a controller. The `RF` models will not work without the controller. There are three wireless controllers to choose from in our range. See section 5.1 for more details. 1.6 Location. All units should be installed horizontally. It is recommended that the ceiling heater is suspended using four 10mm rods. Care must be taken to allow complete free air movement into the inlet grilles of the unit to ensure the correct working operation of the heater. If the- HE7237 or HE7247 heaters are mounted close to the wall or corner the discharge opening should be facing the wall. The minimum distance from the wall or corner is 0.8m or 1.2m for the HE7267. 1.7 Clearance distances It is acceptable for the heater to sit flush to the ceiling. The minimum mounting height (floor to grille) is 2.2m for the HE7237, HE7247 and 2.5m for the HE7267. The recommended mounting height is 2.5m for the HE7237, HE7247 and 3m for the HE7267. 2

1. General Information 1.8 Clearance distances 1.9 Health and Safety Sole liability rests with the installer to ensure that all site safety procedures are adhered to during installation. Sole liability rests with the installer to ensure that protective safety wear such as hand, eye, ear and head protection is used during installation of the product. Do not rest anything especially ladders against the product. 1.10 Standards Units conform to the European electrical standard BS EN 60335-2-30 2. Dimensions SUSPENSION POINTS 3

3. Installation Details. 3.1 Installation Fig.1 Air discharge of HE7237/RF and HE7247/RF It is the sole responsibility of the installer to ensure that the points of attachment to the building are sound. Care must be taken to allow complete free air movement into the inlet grilles of the unit to ensure the correct working operation of the heater. Carefully unpack the unit and control box. The unit is supplied with a length of self-adhesive foam strip. This can be cut into lengths and is to be laid on the 4 sides of the bottom of the heater casing. This will ensure that the unit assembly is free from vibration. The weight of the HE7237/RF, HE7247/RF is 12kg The weight of the HE7267/RF is 15kg ENSURE THE AIR OUTLET OF HE7230 AND HE7245 IS NEAREST TO THE WALL OR CORNER. Fig.2 Air discharge of HE7267/RF - Split and remove shroud A pair of machine screws hold each shroud half together at each joint. A machine screw secures each shroud half to each appliance beam. Remove these machine screws and slide each shroud half off the appliance base panel. The base panel fits inside the shroud halves. The diffuser is already clipped into and under the base panel and need not be removed. - Hanging Rod Positions With the shroud removed the two appliance beams reveal the holes/slots shown and dimensioned below. It is required that two 10 mm hanging rods (stud bars) support each appliance beam. The rods pass through and into each appliance beam. Support washers together with nuts locate and lock the appliance beams after adjustment to level the appliance. Fig.3 Heater assembly SUSPENSION POINTS TERMINAL COVER - Replace Shroud Halves The reverse of above. Slide shrouds beneath and around base panel. Secure each shroud half to each appliance beam with machine screws. Screw shroud halves together at each joint. TOP OR SIDE CABLE ENTRY 4. Electrical Connections. 4.1 Electrical Connections. These units are suitable for connection to a 230/240 Volt 50 Hz single phase supply. The appliance shall be connected to the supply via an appropriate switched fused double pole isolator having a contact separation of greater than 3mm. Test for correct operation and refit the cover. For connection to the mains supply it will be necessary to open the terminal cover at the side/ back of the unit to connect the supply from the controls prior to refitting the cover. Wire in accordance to the wiring diagrams. For safety reasons, a sound earth connection must always be made to the unit before it is put to use. The unit should be wired in accordance with IEE Regulations for the Electrical Equipment of Buildings. 4

4. Electrical Connections. 4.2 Electrical connections for standard models Fig.4 Mains supply direct to heater E N L Fig.5 Remote switch terminal side view L connected by 30A one way connector block L L Fig.6 Mains supply via remote switch F - Fan H1 - Heating element 1 H2 - Heating element 2 N - Neutral E - Earth Two independent live feeds must be used on 4,5kW and 6kW heaters as shown on the diagrams N L L1 E N and E connected by 30A one way connector block L L 4.3 Electrical connections without using the remote switch standard models If the heaters are to be controlled by means other than the remote switch supplied, eg BMS, then the heat output can be selected by connecting the appropriate terminals. Fig.7 Wiring of the heaters without using remote switch WIRED TERMINALS HE7230 HE7245 HE7260 H1 + H2 + F 3000W 4500W 6000W H1 + F 1000W 1500W 2000W H2 + F 2000W 3000W 4000W Please note the F terminal must always be connected 5

4. Electrical Connections. 4.4 Electrical connections for wireless control models Fig.9 Heater with terminal cover open Fig.10 Terminal cover detail 5. Operation. 5.1 Models for wireless controls The heaters for wireless controls, models HE7237W, HE7247W and HE7267W can be controlled by Claudgen wireless controllers CZC1, CZC2 or CZC3. The heaters will not work without a controller. Each controller has unique identification code, it can control unlimited number of heaters and will not interfere with other controllers within the building. For more details please follow the instructions supplied with the controller. Fig.11 CZC1 Fig.12 CZC3 Fig.13 CZC2 5.2 Standard models All standard heaters HE7237, HE7247 and HE7267 are supplied with a remote switch that gives the following functions; On/off & two heat settings. For thermostatic control a room thermostat of appropriate switch rating maybe connected to the circuit. The thermostat should be wired between the isolator switch and the heater remote switch. For HE7247, HE7267 or to control more than one HE7237 heaters by a thermostat, a contactor or a relay in conjunction with the thermostat should be used. To switch on the appliance and operate the blower, depress the left-hand switch (marked FAN ). When the centre switch only (marked with a single bar) is depressed the heat output is ⅓ of full heat. HE7237-1kW, HE7247-1.5kW, HE7267-2kW When the right hand switch only (marked with a double bar) is depressed the heat output is ⅔ of full heat. HE7237-2kW, HE7247-3kW, HE7267-4kW When both the centre switch and the right-hand switch are depressed the full heat output is available. HE7237-3kW, HE7247-4.5kW, HE7267-6kW 6

6. Servicing & Maintenance. 6.1 Maintanence 6.4 Fault Finding ALWAYS ENSURE THAT THE MAIN EXTERNAL ELECTRICITY SUPPLY IS SWITCHED OFF BEFORE COMMENCING ANY MAINTENANCE ON THIS HEATER. To obtain the best results from the heater, it is essential to avoid the accumulation of dust and dirt within the unit on the air inlet and discharge grilles. For this reason regular cleaning is necessary. Cleaning of the fan is best carried out with a soft brush. The product should be serviced annually. Servicing shall be undertaken by a competent person. 6.2 General If the heater does not operate a competent service engineer should be called to identify the nature of the fault. All heaters are fitted with motor thermal protection. Other faults in relation to the element, motor and wiring should be identified using conventional fault finding techniques. In the event that electrical components are replaced, please ensure that electrical safety checks in accordance with the regulations in force in the country of use are undertaken. If the heater will not operate, disconnect it from the mains and arrange for a certified electrician to attend and investigate the reason. 6.5 Replacing the Fan Heater a)split and remove shroud b)remove the grille. c) Disconnect the internal wiring from the blower d) Remove the four screws fixing the fan heater assembly to the back of the case. e) The fan heater assembly can now be eased forward and removed from the heater case. f) Fit replacement fan heater and reassemble in reverse order. 6.6 Spares It is essential when ordering spares or replacement parts to state the model number and the serial number on the rating label fixed to the side of the unit below the terminal cover. In the interest of progress the Company reserve the right to vary specifications from time to time without notice. The material listed is offered subject to the Company s General Conditions of Sale, a copy of which can be obtained on request. 6.3 Thermal cut-out The units are protected from overheating in the event of fan failure or an obstruction of the free airflow, by thermal cut outs. If this happens the thermal cut outs switch off the appliance. The appliance will not operate until the heater is disconnected from the mains supply and it has cooled down. If this fault re-occurs again, refer to the section 6.4 fault finding. Consort Equipment Products Ltd Registered Office: Thornton Industrial Estate Milford Haven, Pembrokeshire, SA73 2RT Tel: 01646 692172 Fax: 01646 695195 BS EN ISO 9001 Registered Company No FM12671 7

8