EMERGENCY ASSISTANCE ALARMS

Similar documents
DISABLED TOILET / EMERGENCY ASSISTANCE ALARMS

Folknoll Group Ltd. DISABLED REFUGE EVC BS :2011COMPLIANT TOUGH, VANDAL RESISTANT IDEAL FOR PUBLIC USE

Fire detection and alarm

Disabled persons toilet alarm kit from Cameo Systems

EVCS EMERGENCY VOICE COMMUNICATION SYSTEMS

communicall connect solutions sheet What is Communicall Connect? Who is it for? What does it consist of?

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Care2 EVC CARE 2 EMERGENCY VOICE COMMUNICATION RADIAL WIRED SYSTEM BENEFITS: FEATURES:

Accessible Toilet Alarm

Solution Sheet. Communicall Vi. Leading housing technology solutions for supported living

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

The EN54 Part 2 & 4 Fire System

Reliably Advanced Extinguishing Control

Conventional & Twin-wire Fire System

Components Brochure DX CONNEXION

Disabled Persons Toilet Alarm Kit

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

Control Panel User Guide

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D)

Emergency Voice Communication System (EVCS) Consu ltant s Specific atio n CONTENTS

ZXSe Range Data Sheet

Memcom Emergency Telephone

User Operation Guide Document: VI49.2

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

The EN54 Part 2, 4 and 13 Fire System

Vocia VACIE. Reference Guide

VACIE REFERENCE GUIDE REVISION 1.2.6

Reliably Advanced Extinguishing Control

Safegard V4 Bespoke Intelligent Damper Control and Monitoring System

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Installation and user manual for the BiWire / Conventional Repeater Panel

HFR100. HFR Alarm Range HFR100. Fire Alarm. HFR600 Wireless Fire/First Aid Alert System. Fire Call Points. Fire Alarm. Features & benefits

ezone Alert System ezone is a UK designed and manufactured care alerting system unlike any other comparably priced system.

SECTION NURSE CALL SYSTEM

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Advanced FireAlarm Panel 1-4Loop

Fire Signalling. Signalling Solutions

HEALTH AND SAFETY FIRE SAFETY POLICY Putnoe Primary School

Intelligent Security & Fire Ltd

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

User Guide. HTM Nurse Call. In the event of requiring assistance, please contact your Installer/Supplier.

USER MANUAL CEF AP28 CONTROL PANEL

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

arm wire free solutions nurse call personal security fire alarms

Intelligent Security & Fire Ltd

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Installation Guide. Disabled Persons Emergency Alarm Kit. Single Zone Call Control/Call answered unit c/w Sounder LED indicators and Braille lettering

intercall innovative care systems

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

Maintenance Guide EMS Security Group Ltd. All rights reserved. MK154 Iss5 18/11/15 AJM

Wireless Fire & Security Solutions. Fire Product Showcase

User Guide. Contents. About this guide. i-on Style Security System

Microphones VIGIL VIGIL. Unitouch. combined data sheets LEADING THE WAY TO SAFETY

SITE SECURITY THE SMARTER WAY TO PROTECT REMOTE AND TEMPORARY SITES, 24 HOURS A DAY.

Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices. Approved to EN54-3/EN54-23

CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3

Parameterisable compact fault annunciator with permanent display

Operating Guide. English Version 3.3

SUPREMATouch. Modular Fire & Gas Detection System

ELECTRONIC SOUNDER STROBE Model : AVD-C407

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Fire Detection - Addressable

FG Wilson Control Systems

Total Unified Solution for Building Integration: Communications, Access Control, Video Surveillance and Fire

Ax60+ Multi-Gas, Quick Connect Option

CONVENTIONAL AUDIBLE VISUAL

Control Panel User Guide (TO BE RETAINED BY THE USER)

Digital Door Entry System. Specification

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

Solution F2. Fire Alarm Control Panels one step ahead.

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Unity DAU Voice Alarm System

OPERATION / INSTALLATION

Product Data Sheet. Remote Terminals. Features:

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

Intelligent Security & Fire Ltd

Control Panel User Guide

DCS-100. intelligent damper control & monitoring system

Integrated Security Solutions

1 to 64 line emergency voice communication system

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

user manual Document No , Revision 03 November 2015

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

999 AMBULANCE POLICE

Entero Voice Alarm system.

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

Acoustic door holder fitting instructions

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

V3 Intelligent Damper Control and Monitoring System

ID50series. intelligent fire alarm panels

Fire Alarm Control Panel. System Maintenance and Log Book

Transcription:

Folknoll Group Ltd. EMERGENCY ASSISTANCE ALARMS BS 8300:2009 AND DOCUMENT M COMPLIANT TOUGH, VANDAL RESISTANT IDEAL FOR PUBLIC USE File:DT 7800-018 DS1 V105 Emergency Assistance Product Information.Docx E+EO (c) 2016 Folknoll Group Ltd

PRODUCT INFORMATION PAGE i CONTENTS 1 EMERGENCY ASSISTANCE ALARMS... 1 2 BASIC (COST-EFFECTIVE)... 2 3 ENHANCED (FULLY FEATURED DOCUMENT M)... 3 4 ILLUMINATED ALARM STRIPS... 4 5 MONITORING OVER DEDICATED CABLES... 5 6 MONITORING OVER TELEPHONE NETWORKS... 6 7 MONITORING OVER IP NETWORKS... 7 8 SNI SIMPLE NETWORK INTERFACE... 8 9 SNI 121 SIMPLE NETWORK MONITORING... 9 10 SNI 828 SIMPLE NETWORK MONITORING... 10 11 SNI 12X SIMPLE NETWORK IO CONTROLLER... 11 12 NIOS NETWORK INTERFACE... 12 13 NIOS NETWORK MONITORING WORKSTATION... 13 14 COMBINED SYSTEMS... 14 15 NOTES... 15 ISSUE DATE DESCRIPTION V 1.00 04.01.2017 Original. V 1.01 14.01.2017 Telephone reset updated. V 1.02 20.02.2017 Images updated, combined systems updated. V 1.03 20.10.2017 Antimicrobial options added, assist changed to assistance and document M compatibility added, wheelchair alarm strip changed to antimicrobial care, pilot alarm strip added. V1.04 03.01.2018 Images of indicator panel with mute button changed to images of indicator panel with acknowledge button, text changed to acknowledged remotely, etc. V1.05 13.08.2018 Simple network interface (SNI) added, NIOS updated, discreet alarm strip removed, text changed to emergency assistance. THIS DOCUMENT This document is the Product Information data sheet for Folknoll Group Ltd Emergency Assistance Alarm systems. ABOUT FOLKNOLL We are a UK based design, manufacturing and installation company. We have been producing communication, alarm and control systems since 1975. All of our products and systems are designed for toughness, reliability, easy installation, simple configuration, straightforward operation and low maintenance. As original manufacturer, all of our product ranges can be customised to suit your application. Including custom engraved panels, additional features and special systems. GET IN TOUCH Please contact us for further information about our wide range of products and services and find out how we can provide a solution for you. ADDRESS: Old North Rd, Royston HERTS, SG8 5TD, UK TEL: +44 (0) 1763 234567 EMAIL: sales@folknoll.co.uk WWW: www.folknoll.co.uk File:DT 7800-018 DS1 V105 Emergency Assistance Product Information.Docx E+EO (c) 2018 Folknoll Group Ltd PAGE i

PRODUCT INFORMATION PAGE 1 1 EMERGENCY ASSISTANCE ALARMS WHAT IS AN EMERGENCY ASSISTANCE ALARM? An emergency assistance is an alarm system that allows a person in distress to call for assistance. They are typically located in accessible toilets, bedrooms, showers, etc. and used to alert staff when help is required. TYPICAL ALARM SYSTEM A typical system comprises a pull cord and reset button located inside a room or toilet with a beacon / sounder usually mounted outside, near the door, to indicate the source of the alarm PULL CORD AND BEACON SOUNDER If assistance is required, the user pulls the pull cord and activates the alarm. The beacon sounder outside the room sounds and flashes to attract attention. REMOTE MONITORING Larger sites may have remote monitoring located in receptions, security rooms, etc. to attract the attention of staff. We offer remote monitoring over dedicated cables, telephone networks, IP networks and combinations of the above. Alarms may be acknowledged but not cancelled remotely, requiring staff to attend the location of the incident to reset the alarm. ACKNOWLEDGE / ACCEPT An acknowledge or accept button maybe fitted outside the room near the beacon sounder. The acknowledge button silences the sounders and causes beacons to stop flashing and illuminate continuously for two minutes. Staff responding the alarm may press the acknowledge button to reassure the user that help has arrived and make voice communication easier. RESET When the situation has been resolved the reset button is pressed to turn off the alarms and reset the system. The system is now ready for the next alarm activation. If the alarm is not reset within two minutes of being acknowledged the alarm sounders are reactivated and the beacons will start to flash. FOLKNOLL We offer a wide range of emergency assistance alarm modules in a variety of styles and finishes including antimicrobial. Enabling us to build the right system for you. File:DT 7800-018 DS1 V105 Emergency Assistance Product Information.Docx E+EO (c) 2018 Folknoll Group Ltd PAGE 1

PRODUCT INFORMATION PAGE 2 2 BASIC (COST-EFFECTIVE) For locations with minimal requirements, we recommend our cost-effective basic systems. These offer simple to operate and install, vandal resistant, emergency assistance alarm systems. Cost effective Tough vandal resistant BS 8300:2009 compliant Screw terminal connection Range of activators Range of annunciators Antimicrobial pull cords and finishes available Ideal for public places RANGE OF ALARM CALL POINTS One or more pull cords, call switches or other activators to enable users to call for assistance. Activators are usually located to allow easy access for wheelchair users, users who are standing and users who have fallen on the floor. RANGE OF BEACON SOUNDERS One or more beacon sounders located outside the room to attract attention in the event of an alarm and help staff identify the source of the alarm. RESET UNIT A basic reset unit to enable staff to reset the alarm. Usually located inside the room to encourage staff attendance in response to an alarm. POWER SUPPLY UNIT A battery backed PSU to maintain operation in the event of a mains supply fail. SIMPLE OPERATION The user activates the alarm by pressing a call point or pulling a pull cord. The beacon sounder is activated to attract attention. Staff respond to the alarm, then press the reset button when the incident is resolved. File:DT 7800-018 DS1 V105 Emergency Assistance Product Information.Docx E+EO (c) 2018 Folknoll Group Ltd PAGE 2

PRODUCT INFORMATION PAGE 3 3 ENHANCED (FULLY FEATURED DOCUMENT M) For locations that require compliance with The department for communities and local government 9 March 2016 statutory guidance approved document M volume 2 we recommend our fully featured, enhanced system. Tough vandal resistant BS 8300:2009 compliant Document M compatible Acknowledge function Heartbeat option Antimicrobial pull cords and finishes available Ideal for public places SAME RANGE OF ALARM POINTS Located to enable wheelchair users and other users to activate an alarm. SAME RANGE OF BEACON SOUNDERS Document M requires the emergency assistance call signal outside the toilet compartment is located so that it can be easily seen and heard by those able to give assistance;. To comply with this requirement one or more beacon sounders maybe located outside the room to attract attention. Depending on the layout of the site, remote monitoring, please refer to sections 5, 6, 7, 8 for our remote monitoring options. ADDITIONAL AUDIBLE REASSURANCE An enhanced reset with internal buzzer that mimics the action of the beacon sounder to give the user a positive audible alarm activation indication inside the room to reassure the user.. ADDITIONAL ACKNOWLEDGE / ACCEPT FUNCTION Document M requires visual and audible indicators to confirm that an emergency call has been received;. Our enhanced system offers an acknowledge button allowing staff to accept alarms. When an alarm is accepted beacons and LEDs stop flashing and sounders are muted, reassuring users that help has arrived and making verbal communication easier. If the alarm has not been reset within two minutes the alarm is reactivated. ADDITIONAL HEARTBEAT OPTION An option to periodically flash reset buttons, call point buttons, pull cord LEDs and beacons, to reassure users and staff that the alarm system is powered and operating correctly. Please specify when ordering. File:DT 7800-018 DS1 V105 Emergency Assistance Product Information.Docx E+EO (c) 2018 Folknoll Group Ltd PAGE 3

PRODUCT INFORMATION PAGE 4 4 ILLUMINATED ALARM STRIPS Illuminated alarm strips offer a great alternative or addition to pull cords. Strips avoid the risks associated with using pull cords as ligatures and are more vandal resistant. Strips can also cover long walls, staircases, etc. The strip illumination, which is battery backed, draws attention to the strip and can be useful if the mains fails in a toilet or other windowless room. Tough vandal resistant BS 8300:2009 compliant Illuminated alarm strips Choice of colours Acknowledge function Fault monitoring Range of annunciators Antimicrobial alarm strips and finishes available Ideal for anti-ligature environments MOUNTING Alarm strips can be mounted horizontally, at an angle or vertically. Brackets, corners, bends, etc. are available for changes in direction. Multiple strips can activate the same alarm, allowing parallel strips at different heights along a wall. Alarms are activated by pressing a strip anywhere along its length. The entire strip is illuminated by LEDs, which flash on alarm activation providing user reassurance, source indication and deterrence. RANGE OF STRIPS We offer a range of colours, illumination, IP rating and antimicrobial options in three profiles: Care: Wheelchair-resistant profile, for low-level mounting in public toilets, etc. Safe: Standard profile, for mounting at higher level, easy-to-hit, ideal for attack alarms. Out IP67 variants are suitable for pools, saunas, showers, etc. File:DT 7800-018 DS1 V105 Emergency Assistance Product Information.Docx E+EO (c) 2018 Folknoll Group Ltd PAGE 4

PRODUCT INFORMATION PAGE 5 5 MONITORING OVER DEDICATED CABLES Ensuring alarms are noticed and responded can be a real problem in some environments, e.g. noisy shops, factories or seldom used quiet corridors, stairwells, etc. For this reason Folknoll offer remote monitoring, to report alarms where people will notice them. Tough vandal resistant panels (Can be installed in public areas) Audible alert and alarm source indication Optional alarm acknowledge / mute function Optional fault monitoring Ideal for larger sites SIMPLE MONITORING Simple monitoring using indicator panels with sounders to alert staff. These can be mounted in reception areas or anywhere that is permanently staffed to ensure the alarm is noticed. We offer a range of standard and custom LED panels to suit requirements. FULL FEATURED MONITORING We offer a range of LCD and panels for remote monitoring of any of our emergency assistance alarms. The panels have a built-in sounder to alert staff to alarm activation, and an LCD to display the location of the alarm. Options include mute, acknowledge / accept buttons, keyed switched, additional beacons/ sounder, etc. For document M compatibility we usually recommend the acknowledge button option, offering a means of activating visual and audible indicators to confirm that an emergency call has been received. EXTENDED MONITORING Remote monitoring systems can be extended and cabling simplified using our IO controllers. These act as alarm concentrators and also have outputs for local beacon / sounder operation, etc. File:DT 7800-018 DS1 V105 Emergency Assistance Product Information.Docx E+EO (c) 2018 Folknoll Group Ltd PAGE 5

PRODUCT INFORMATION PAGE 6 6 MONITORING OVER TELEPHONE NETWORKS Take advantage of existing telephone systems to save cabling and gain PABX functionality. Cost effective Uses telephone cabling Operator can talk to users Take advantage of telephone system functions Ideal for large sites AUDIO COMMUNICATION Alarms systems are cabled to the nearest telephone network access point. If the call button is pressed or an alarm is activated, the reset unit dials the monitoring station to alert the operator. If the user is able to speak he/she can explain their situation to the operator. The operator is then able to arrange an appropriate response, increasing the effectiveness, improving user experience. SAVE ON CABLING, MAXIMISE FEATURES Using the existing telephone network, reduces cabling costs, disruption, etc. and enables use of telephone facilities, call forwarding, recording, etc. Calls can be made offsite, or to mobile phones held by ground staff. EASY EXPANSION Each emergency assistance alarm is an independent system, new alarms can be added without extra control equipment or configuration, simply plug into a telephone socket. File:DT 7800-018 DS1 V105 Emergency Assistance Product Information.Docx E+EO (c) 2018 Folknoll Group Ltd PAGE 6

PRODUCT INFORMATION PAGE 7 7 MONITORING OVER IP NETWORKS Leverage existing network infrastructure to save cabling, access awkard locations, etc. User existing or dedicated network Add alarms to existing system Construct new systems with minimal cabling Ideal for large sites, or multiple locations Folknoll NIOS workstations BMS interfaces LARGE SYSTEMS Ideal for large buildings or multi-site establishments with centralised or off-site facilities management / monitoring. COST-EFFECTIVE Take advantage of your existing infrastructure to provide monitoring of alarms throughout your site. Saving on cabling and installation costs and conforming with modern building cabling practice. COMPATIBLE Network monitoring can be added to any of our emergency assistance alarm systems including basic, enhanced, and alarm strip systems. FULL SYSTEMS We offer a range of IP interfaces, networked PC workstations, event logs PCs, and other network devices to realise solutions. EXTEND TRADITIONAL CABLING We also use IP infrastructure to extend existing systems, e.g. adding a new alarm point, hopping between buildings, etc. Reducing disruption and costs when adding to the system. File:DT 7800-018 DS1 V105 Emergency Assistance Product Information.Docx E+EO (c) 2018 Folknoll Group Ltd PAGE 7

PRODUCT INFORMATION PAGE 8 8 SNI SIMPLE NETWORK INTERFACE Our simple network monitoring interface (SNI) adds cost-effective document M compatible remote monitoring and acknowledge function to new and existing emergency assistance. Remote monitoring Document M compatible acknowledge Utilises standard IP network, saves installation costs, disruption, etc. Supplied fully configured Works with a range of alarm activation equipment, including shower buttons and alarm strips SNI Our simple network interface mounts inside the local system PSU and connects to a nearby network switch. REMOTE MONITORING For small systems (up to 8 alarms) the local SNI is monitored by a paired remote SNI, please refer to sections 9 SNI 121 Simple Network Monitoring and 10 SNI 828 Simple Network Monitoring. For larger systems (up to 256 alarms) the local SNIs are monitored by a Network IO Controller please refer to section 11 SNI 12X Simple Network IO Controller. SNI systems usually have an indicator panel to alert operators and provides an acknowledge button. ACKNOWLEDGE / ACCEPT All SNI systems offer a document M compatible acknowledge function. The acknowledge function enables local and remote panels to 'accept' and temporarily mute alarms, giving reassurance that help is on its way and making verbal communication easier. If the alarm has not been reset within two minutes the alarm is reactivated. The remote monitoring device cannot usually reset alarms. Emergency assistance alarms should only be reset at the 'reset unit' to ensure staff attendance in the event of an alarm activation. CONFIGURATION All SNIs and network IO controllers are supplied fully configured to your requirements, simply install and connect to your network. SIMPLE FAULT MONITORING If simple communications fault reporting is required please refer to section 11 SNI 12X Simple Network IO Controller. NIOS For more comprehensive remote systems with PC workstations, optional mains and battery status, remote alarm strip fault monitoring please refer to sections 12 NIOS Network Interface and 13 NIOS Network Monitoring Workstation. File:DT 7800-018 DS1 V105 Emergency Assistance Product Information.Docx E+EO (c) 2018 Folknoll Group Ltd PAGE 8

PRODUCT INFORMATION PAGE 9 9 SNI 121 SIMPLE NETWORK MONITORING Simple network document M monitoring for a single alarm. Ideal for small sites, shops, waiting rooms, etc. Document M compatible alarm monitoring with acknowledge function for single alarm Cost-effective, simple solution, SNI paired interfaces, static IP, same subnet Utilises standard IP network, saves costs, disruption, etc. Can be fitted to existing stand-alone systems Works with Folknoll LCD indicator panels and compact LCD indicator panels SIMPLE 121 NETWORK MONITORING Our simple 121 networking solution offers document M compatible remote monitoring and acknowledge function for a single alarm over a standard IP network. REMOTE OPERATOR STATION SNI systems are usually operated (monitored) from a remote indicator panel or compact indicator panel. The local SNI is linked across the network by a paired SNI mounted in the indicator panel PSU or compact master station. DESIGN CONSTRAINTS PARAMETERS Up to 8 repeat indicator panels can be linked over RS485 2 static IP4 addresses required per alarm All devices must be on same subnet If alarm strips are used, a dual gang reset is required If simple device offline indication is required please refer to section 11 SNI 12X Simple Network IO Controller If remote alarm strip fault indication is required please refer to sections 12 NIOS Network Interface and 13 NIOS Network Monitoring Workstation If mains and battery status indication is required please refer to sections 12 NIOS Network Interface and 13 NIOS Network Monitoring Workstation File:DT 7800-018 DS1 V105 Emergency Assistance Product Information.Docx E+EO (c) 2018 Folknoll Group Ltd PAGE 9

PRODUCT INFORMATION PAGE 10 10 SNI 828 SIMPLE NETWORK MONITORING Simple network document M monitoring for up to 8 alarms. Ideal for small building, offices, etc. Document M compatible alarm monitoring with acknowledge function for up to 8 alarms Cost-effective, simple solution, SNI paired interfaces, static IP, same subnet Utilises standard IP network, saves costs, disruption, etc. Can be fitted to existing stand-alone systems Works with Folknoll LCD indicator panels and compact LCD indicator panels SIMPLE 828 NETWORK MONITORING Our simple 828 networking solution offers document M compatible remote monitoring and acknowledge function for up to 8 alarms over a standard IP network. REMOTE OPERATOR STATION SNI systems are usually operated(monitored) from a remote indicator panel or compact indicator panel. The local SNIs are linked across the network by paired SNIs mounted in the indicator panel PSU or compact master station. SYSTEM PARAMETERS Up to 8 alarms per indicator panel Up to 8 repeat indicator panels can be linked over RS485 2 static IP4 addresses required per alarm All network devices must be on same subnet If alarm strips are used, dual gang resets are required If simple device offline indication is required please refer to section 11 SNI 12X Simple Network IO Controller If remote alarm strip fault indication is required please refer to sections 12 NIOS Network Interface and 13 NIOS Network Monitoring Workstation If mains and battery status indication is required please refer to sections 12 NIOS Network Interface and 13 NIOS Network Monitoring Workstation File:DT 7800-018 DS1 V105 Emergency Assistance Product Information.Docx E+EO (c) 2018 Folknoll Group Ltd PAGE 10

PRODUCT INFORMATION PAGE 11 11 SNI 12X SIMPLE NETWORK IO CONTROLLER For larger systems we offer our network IO controller simple network document M compatible monitoring for systems with up to 256 alarms. Ideal for larger locations and specialist systems. Document M compatible alarm monitoring with acknowledge function for up to 8 alarms Cost-effective, simple solution, SNI paired interfaces, static IP, same subnet Utilises standard IP network, saves costs, disruption, etc. Can be fitted to existing stand-alone systems Simple device monitoring, with device off-line indication Works with Folknoll LCD indicator panels and compact LCD indicator panels SIMPLE 12X NETWORK MONITORING Our simple 12X networking solution offers document M compatible remote monitoring and acknowledge function for up to 256 alarms over a standard IP network. REMOTE OPERATOR STATION SNI systems are usually operated(monitored) from a remote indicator panel or compact indicator panel. The local SNIs are linked across the network to a network IO controller capable of monitoring up to 256 alarms. The network IO controller is mounted in the indicator panel PSU or compact master station and requires a single network access point. DESIGN CONSTRAINTS Up to 256 alarms per indicator panel Up to 8 repeat indicator panels can be linked over RS485 or IP 1 static IP4 address per alarm + 1 static or DCHP IP4 address for network IO controller required Same subnet, NAT, DDNS, partial DCHP configuration options If alarm strips are used dual gang resets are required If remote alarm strip fault indication is required please refer to sections 12 NIOS Network Interface and 13 NIOS Network Monitoring Workstation If mains and battery status indication is required please refer to sections 12 NIOS Network Interface and 13 NIOS Network Monitoring Workstation File:DT 7800-018 DS1 V105 Emergency Assistance Product Information.Docx E+EO (c) 2018 Folknoll Group Ltd PAGE 11

PRODUCT INFORMATION PAGE 12 12 NIOS NETWORK INTERFACE Our NIOS network monitoring interface (NNI) adds cost-effective document M compatible remote monitoring and acknowledge function to new and existing emergency assistance alarms. Document M compatible remote monitoring with acknowledge function Utilises standard IP network, saves installation costs, disruption, etc. Supplied fully configured Works with a range of alarm activation equipment, including shower buttons and alarm strips Optional mains and backup battery status monitoring Optional alarm strip fault status NNI Our NIOS network interface mounts inside the local system PSU and connects to a nearby network switch. REMOTE MONITORING The local NNI is monitored by a NIOS pc, the NIOS PC offers a plan-based GUI, optional mains and battery status monitoring, and optional alarm strip fault monitoring. please refer to section 13 NIOS Network Monitoring Workstation. ACKNOWLEDGE / ACCEPT All NIOS systems offer a document M compatible acknowledge function. The acknowledge function allows local or remote devices to 'accept' and temporarily mute alarms, giving reassurance that help is on its way and making verbal communication easier. If the alarm has not been reset within two minutes the alarm is reactivated. The remote monitoring device cannot usually reset alarms. Emergency assistance alarms should only be reset at the reset unit to ensure staff attendance in the event of an alarm activation. NIOS FAULT MONITORING The NIOS system offers a range of fault monitoring options including network device off-line, mains status, backup battery status, alarm strip status. Ideal for large site with heavy maintenance schedules CONFIGURATION All NIOS NIs an are supplied fully configured to your requirements, simply install and connect to your network. DESIGN CONSTRAINTS 1 static IP4 address + 1 static or DHCP IP4 address for NIOS workstation required Same subnet and partial DCHP configuration options If alarm strips are used dual gang resets are required If mains and battery status indication is required, our optional power status board is required File:DT 7800-018 DS1 V105 Emergency Assistance Product Information.Docx E+EO (c) 2018 Folknoll Group Ltd PAGE 12

PRODUCT INFORMATION PAGE 13 13 NIOS NETWORK MONITORING WORKSTATION Our network monitoring software provides a plan-based graphical workstation, with alarm source indication, event logs, fault, mains fail and battery status reporting and other configurable features. Ideal for larger locations and specialist systems. Graphical alarm source indication Alarm status list, Audible alert Fault monitoring Event Log Optional mains and battery backup status monitoring Standard PC hardware and Windows 7 or 10 operating system Optional wall mounted touch screen NIOS Our NIOS PC Workstation enables operators to monitor remote emergency assistance alarms and faults over standard IP networks. ALERTS The workstation alerts operators to alarms by generating a warning tone and indicating the source of the alarm on a site plan. Enabling an efficient response to activations. ACKNOWLEDGE / ACCEPT The acknowledge function allows local or remote devices to 'accept' and temporarily mute alarms, giving reassurance that help is on its way and making verbal communication easier. If the alarm has not been reset within two minutes the alarm is reactivated. The workstation cannot usually be used to reset alarms. Emergency assistance alarms should only be reset within the room using the 'reset button' to ensure staff attendance in the event of an alarm activation. FAULT MONITORING NIOS provides network and communications fault reporting to aid maintenance and help ensure reliability. Options are available for mains status, backup battery status alarm strip cabling faults, and other alarms. EVENT LOG All alarms and faults are recorded in an event log which can easily be viewed on the workstation. CONFIGURATION The workstation is supplied fully configured for your application. Our software comes with easy-touse, built-in configuration pages to allow for maintenance, system updates, etc. BMS The NIOS application offers an output stream for third-party systems, enabling our emergency assistance alarms to be incorporated into BMS and other systems. File:DT 7800-018 DS1 V105 Emergency Assistance Product Information.Docx E+EO (c) 2018 Folknoll Group Ltd PAGE 13

PRODUCT INFORMATION PAGE 14 14 COMBINED SYSTEMS COMBINED SYSTEMS Combining systems reduces control room space, cabling, installation costs, etc. whilst simplifying operation and maintenance. Enabling the provision of practical, cost-efficient, BS compliant systems. Ideal for smaller buildings and complexes. POSSIBLE COMBINATIONS INCLUDE Disabled refuge EVC Emergency assistance Fire telephone Building alarms system All systems are monitored from a single master station. All your monitoring in one place. SINGLE FIRE PANEL SIZED ENCLOSURE All control boards, PSUs, batteries, etc. mounted inside the monitoring station. Only mains and outstations, alarms, etc. required for a complete system. Saves money, installation costs, space, etc. MONITORING KITS We also offer remote panel kits that can be built into panels, consoles and other enclosures. Add emergency assistance and other alarm monitoring to third-party systems. File:DT 7800-018 DS1 V105 Emergency Assistance Product Information.Docx E+EO (c) 2018 Folknoll Group Ltd PAGE 14

PRODUCT INFORMATION PAGE 15 15 NOTES File:DT 7800-018 DS1 V105 Emergency Assistance Product Information.Docx E+EO (c) 2018 Folknoll Group Ltd PAGE 15

Folknoll Group Ltd. Old North Rd, Royston, HERTS, SG8 5DT, UK +44 (0) 1763 234567 sales@folknoll.co.uk www.folknoll.co.uk