GARAGE / WORKSHOP INFRARED HEATERS 22,000-25,000 BTU/HR Heater For: Garages / Workshops Barns / Utility Buildings / Storage Sheds Animal Pens / Stalls Loading Docks Building Construction Sites Doorways / Ramps For Snow Prevention America s Most Complete Line Of Infrared Heaters!
HIGHLY EFFICIENT AND COST EFFECTIVE RADIANT HEAT. Efficient Infrared Heat - Directly heats people and objects which in turn heats surrounding air to desired temperature. Economical - No electricity required Instant Heat - Includes adjustable thermostat for individually controlled warmth Large Capacity - Heats 500-600 sq. ft. (2 1 /2 car garage) Convenient - Easy to operate and install Quiet, Clean, Odor-Free Operation - propane or natural gas Gas supply connection is 1/2 dia. (NPT) gas pipe. Ships Complete In Package For Easy Installation Includes Wall Louver For Fresh Air Intake Maintenance Free - No moving parts to service CSA Certified Limited 1 Year Warranty - On gas control Limited 5 Year Warranty - On burner Unique thermopile/thermocouple generates power from pilot flame for gas control. Automatically shuts off gas if pilot light goes out. Aluminized steel burner plenum houses venturi and baffles, enabling air-gas mixture to produce constant grid combustion with no wasted fuel. Millivolt powered thermostat adjusts for individual comfort levels. No electricity required. Chrome-plated, steel grill protects burner from any damaging object. Why Heat A Garage? There are over 40 million single family residential garages in the U.S. SPECIFICATIONS & TECHNICAL DATA BTU/HR. RATING MOUNTING CLEARANCE NORMAL TO COMBUSTIBLES NATURAL MOUNTING MODEL NUMBER GAS PROPANE POSITION TOP SIDE BACK BELOW 22,000* 30º 14 1 12 48 HS22L Stock Number: F125545 HS25N Stock Number: F125444 25,000* 30º 14 1 12 Welded wall mounting bracket simplifies installation. A typical 2 car garage represents approximately 20% of the usable space in an average home Garages are the most under-utilized space in most climates during the winter months 55% of all homes have natural gas Cold garage temperatures may affect vehicles and plumbing A heated garage can be used for DIY Auto / Mechanical Maintenance / Workshop / Hobby Activities / Recreation (exercise equipment, table tennis, etc.) / Pet Comfort / Laundry 48 REFLECTOR LxWxH (INCHES) 26 1 /2 x 11 9 /16 x 3 1 /4 26 1 /2 x 11 9 /16 x 3 1 /4 TOTAL LxWxH (INCHES) 29 3 /4 x 12 1 /4 x 7 29 3 /4 x 12 1 /4 x 7 SHIPPING WEIGHT (LBS) 25 25 GAS INLET 1 /2 1 /2 CSA Certified MANIFOLD PRESSURE 10 * Ratings shown are for elevations up to 2,000 feet. (In Canada, refer to rating tag.) For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level or as specified by local authority having jurisdiction. DO NOT use this in sleeping quarters, mobile homes, or recreational vehicles. www.enerco.com Enerco Group Inc. 4560 West 160th St. Cleveland, Ohio 44135 800-251-0001 L201
ERXL RADIANT TUBE HEATERS 60,000-175,000 BTU/HR Heaters For: Manufacturing Plants Automobile Dealerships Truck Terminals & Body Shops Repair Shops & Garages Loading Docks Warehouses Farm Buildings Aircraft Hangers Indoor Sporting Arenas Fire Stations Stables Green Houses Custom Applications America s Most Complete Line Of Infrared Heaters!
HIGHLY EFFICIENT AND COST EFFECTIVE RADIANT TUBE HEAT. Full 10-Year Limited Warranty 16-Gauge Aluminized Tubing Outside Or Inside Air For Combustion Sealed Burner Control Box Full Cover Polished Aluminum Reflector Installs Easily As Straight Or U-Tube Configurations Features Available In 20 To 60 Foot System Lengths Horizontal Or 45 Degree Angle Of Reflectors Stainless Steel Couplers Chrome Plated Hanging Brackets Burner Sight Glass All Components Are Name-Brand Non-Proprietary 24 Volt Or Line Voltage Thermostat Installation Option SPECIFICATIONS & TECHNICAL DATA CSA Certified MODEL NUMBER BTU x 1000 ERXL 60 N/LP* ERXL 80S N/LP ERXL 80 N/LP ERXL 100S N/LP ERXL 100 N/LP ERXL 125S N/LP ERXL 125 N/LP ERXL 150 N/LP ERXL 150L N/LP ERXL 175 N/LP ERXL 175L N/LP LENGTH 20 20 30 30 40 40 50 50 60 50 60 MOUNTING CLEARANCE TO COMBUSTIBLES FROM TOP - HORIZONTAL FROM TOP - AT 45º ANGLE 12 STRAIGHT BELOW 55 55 55 74 74 SIDE 3 3 3 3 3 3 3 3 3 3 3 TYPICAL MOUNTING HEIGHT 10-14 14-19 14-19 SHIPPING WEIGHT (LBS) 110 110 110 130 150 150 170 170 190 170 190 ELECTRICAL 120 volt-60 Hz Starting Current 5.0 amps Running Current 1.0 amps BURNER Heaters are equipped with a silicon carbide hot surface ignition and electronic safety circuitry COMBUSTION CHAMBER / HEAT EXCHANGER 4 Aluminized steel tubing - 16 gauge GAS SUPPLY Natural Gas Min 4. w.c. - Max 14.0 w.c. LP Gas Min 11.0 w.c. - Max 14.0 w.c. FLUE CONNECTION GAS CONNECTION 4 (O.D.) 1/2 NPT WARRANTY 10-year limited warranty on all electrical components, burner and tubes * N = Natural Gas LP = Propane www.enerco.com Enerco Group Inc. 4560 West 160th St. Cleveland, Ohio 44135 800-251-0001 L208
Model UDAP Page Number of Power Vented, Low Static Axial Fan Unit Heaters for Residential and Commercial/Industrial Use Sizes 30-125 approved for utility applications such as residential garages under CSA International Requirement 10.96 - U.S. and CR96-0005 - Canada CSA 2.6b ANSI Z83.8b DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED Reznor V3 Series Model UDAP gas-fired unit heaters are available in 14 sizes ranging from 30,000 to 400,000 BTUH gas input. Sizes 30-125 are approved for residential application. All sizes are approved for commercial/ industrial installations. Model UDAP heaters are designed for 82-83% thermal efficiency and are approved for installation in the United States and Canada by the Canadian Standards Association (CSA). Reznor V3 Series unit heaters have a refreshing new appearance with a glossy white cabinet finish and less visible hardware. Each size cabinet is easily suspended from either 2 or 4 suspension points. Or, an optional hanger kit for Sizes 30-125 allows for ceiling mounting. The low voltage terminal strip on the outside of the cabinet makes connecting control wiring easy with no panels to remove. The addition of a G terminal to the strip, along with the new design of the circuit board, allows for fan only operation (without adding relays). All units have a factory installed gas line nipple to the exterior of the cabinet for easy gas service connection. The preeminent new internal feature is the Tcore2 heat exchanger and single burner combustion system. Other standard features include a single-stage gas valve, multi-try direct spark ignition with 100% lockout, pressure switch to verify vent flow, resiliently isolated venter motor, venter wheel with improved housing, resiliently isolated axial fan and motor assembly, and a high temperature limit control. Sizes 30-125 also include a flame rollout safety switch. Operation is controlled through an integrated circuit board. The circuit board monitors heater operation and has LED diagnostic indicator lights to identify abnormalities in control functions. The V3 Series unit heaters are designed to provide all the features you expect in a Reznor heater plus improved efficiency, easier installation, and a new look ~ both inside and out. Look for the unique white unit with no visible front and bottom hardware, deep red louvers, black side handle, and angled corner to know you have a genuine Reznor unit by Thomas & Betts. Sizes 30-125 certified for residential heating application Sizes 30-400 certified for commercial/industrial heating application 82-83% Thermal efficient ~ TOP in its class! 50-60 F Rise range Tcore 2 titanium stabilized aluminized steel heat exchanger Patented** Tcore 2 single burner combustion system including a one-piece burner assembly 115/1/60 Supply voltage 115 Volt open fan motor with internal overload protection Transformer for 24-volt controls Integrated circuit board with diagnostic indicator lights Multi-try direct spark ignition with 100% lockout Fan relay (included on the circuit board) Single-stage natural gas valve (field adjustable for operation to 9,000 ft. elevation) Vibration/noise isolated fan and venter motors ~ designed for low noise operation 2-pt and 4-pt Suspension ~ standard on all sizes External terminal strip for 24-volt wiring External gas connection Full fan guard ~ engineered for safety Improved cabinet design with less visible hardware and a NEW Reznor appearance Single-stage, propane gas valve (field adjustable for operation to 9,000 ft. elevation) Two-stage natural gas or propane gas valve - Sizes 60-400 409 or 316 Stainless steel heat exchangers 208 or 230 Single phase voltage Totally enclosed fan motor (Sizes 30-250, 115V only) Common venting with other gravity vented Category I appliance(s) (Sizes 30-100) * * U.S. Patent No. 6,889,686 Form RZ-C-UH (Version H) Page 8
OPTIONAL FEATURES - FIELD INSTALLED Vent cap Thermostat Thermostat guard with locking cover Vertical louvers ~ new design Downturn nozzle kits ~ new design Gas conversion kits (natural and propane) Master/Slave controls for zoning up to six units Ceiling suspension kit - Sizes 30-125 Hanger kits for 1 pipe Stepdown transformer (for 230/3 and 460/3 supply voltage) Manual shutoff valves Page Number of TECHNICAL DATA Model UDAP Size 30 45 60 75 100 125 150 175 200 225 250 300 350 400 Input Heating Capacity BTUH 30,000 45,000 60,000 75,000 105,000 120,000 150,000 175,000 200,000 225,000 250,000 300,000 350,000 400,000 kw/h 8.8 13.2 17.6 22.0 30.8 35.2 43.9 51.2 58.6 65.9 73.2 87.8 102.5 117.1 Thermal Efficiency (%) 82 83 83 83 83 83 83 83 83 83 83 83 83 83 Output Heating BTUH 24,600 37,350 49,800 62,250 87,150 99,600 124,500 145,250 166,000 186,750 207,500 249,000 290,500 332,000 Capacity A kw/h 7.2 11.0 14.6 18.3 25.6 29.2 36.4 42.5 48.6 54.7 60.8 72.9 85.1 97.2 Gas Connection Natural 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 (inches) B Propane 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 Vent Connection Size C (inches diameter) 4 4 4 4 4 4 5 5 5 5 5 6 6 6 Control Amps (24 volt) 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Full Load Amps (115 volt) 1.9 2.4 2.4 3.3 3.9 5.1 3.8 3.8 4.6 7.5 7.5 11.0 11.0 11.0 Maximum Over Current Protection 15 15 15 15 15 15 15 15 15 15 15 20 (115V) D 20 20 Normal Power Consumption (watts) 109 155 155 217 276 354 392 392 491 747 747 1086 1086 1086 Discharge Air Temperature Rise ( F) 50 55 60 60 60 60 60 60 60 60 60 60 60 60 Air Volume CFM 456 629 769 961 1345 1537 1921 2242 2562 2882 3202 3843 4483 5123 M 3 /minute 12.9 17.8 21.8 27.5 36.7 45.9 54.4 63.5 72.5 81.6 90.7 108.8 126.9 145.1 Discharge Air Opening ft 2 0.96 0.96 1.25 1.25 2.01 2.01 2.56 2.56 2.56 3.51 3.51 4.79 4.79 4.79 Area M 2 0.09 0.09 0.12 0.12 0.19 0.19 0.24 0.24 0.24 0.33 0.33 0.45 0.45 0.45 Output Velocity FPM 475 656 616 770 668 763 752 877 1003 820 911 802 936 1069 M/minute 145 200 188 238 196 245 229 267 306 250 278 244 285 326 Open 0.02 0.03 0.03 0.06 1/30 1/20 1/6 1/6 1/6 1/4 1/4 1/2 1/2 1/2 Fan Motor HP E Enclosed 0.06 0.06 0.06 0.06 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/2 1/2 1/2 Fan Motor RPM 1550 1550 1550 1550 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 Fan Diameter (inches) 10 10 12 12 16 16 18 18 18 20 20 24 24 24 Sound Level dba @ 15 ft 40 40 40 49 54 55 51 52 53 56 56 59 61 62 Approximate Net lbs 54 59 67 72 96 101 172 187 187 203 215 269 294 306 Weight kg 24 27 30 33 44 46 78 85 85 92 98 122 133 139 Approximate Ship lbs 61 66 74 79 118 123 204 219 219 245 257 321 346 358 Weight kg 27 30 33 36 54 56 93 100 100 111 117 146 157 163 A CSA rating for altitudes to 2000 ft. B Size shown is for gas connection to a single stage gas valve, not supply line size. C Smaller or larger vent pipe diameters may be allowed; refer to the Venting Installation Manual, Form I-V-PV. If vent diameter is different from vent connection, reducer/enlargers will be field-required. D MODP = 2.25 x (largest motor FLA) + smallest motor FLA. Answer is rounded to the nearest commercially available circuit breaker. E All other information in this table is based on a heater equipped with a standard 115 volt open fan motor. Form RZ-C-UH (Version H) Page 9
Model UDAP ±1/16" (2mm) Page Number of Size A B C D E F G H J K M N P Q R 30, 45 12 1/8 25 5/8 10 13 13/16 26 21 9/16 5 3/16 6 1/2 2 11/16 3 7/8 17 3/8 11/16 4 5/16 13 9 9/16 60 15 1/8 25 5/8 13 13 13/16 27 21 9/16 7 7/8 6 1/2 5 1/2 3 7/8 17 3/8 11/16 4 5/16 13 10 1/2 75 15 1/8 25 5/8 13 13 13/16 27 5/8 21 9/16 7 7/8 6 1/2 5 1/2 3 7/8 17 3/8 11/16 4 5/16 13 10 1/2 100 23 1/8 25 5/8 21 13 13/16 28 5/8 21 9/16 14 1/2 6 1/2 8 3/4 3 7/8 17 3/8 11/16 4 5/16 13 10 1/2 125 23 1/8 25 5/8 21 13 13/16 29 3/8 21 9/16 14 1/2 6 1/2 8 3/4 3 7/8 17 3/8 11/16 4 5/16 13 10 1/2 150, 175, 200 20 1/8 38 3/16 16 2 3 42 35 3/8 8 1/2 8 1/4 5 7/16 6 1/2 25 11/16 1 3/8 8 3/16 22 3/16 16 3/8 225, 250 26 1/8 38 3/16 22 23 42 35 3/8 13 1/16 8 13/16 9 6 1/2 25 11/16 1 3/8 8 3/16 22 3/16 15 5/8 300, 350, 400 34 1/8 4 1 30 23 42 35 3/8 17 1/16 9 11 13/16 7 5/16 27 11/16 1 3/8 8 3/16 22 3/16 16 3/16 Size A B C D E F G H J K M N P Q R 30, 45 (308) (651) (254) (351) (660) (548) (132) (165) (68) (98) (441) (17) (110) (330) (243) 60 (384) (651) (330) (351) (686) (548) (200) (165) (140) (98) (441) (17) (110) (330) (267) 75 (384) (651) (330) (351) (702) (548) (200) (165) (140) (98) (441) (17) (110) (330) (267) 100 (587) (651) (533) (351) (727) (548) (368) (165) (222) (98) (441) (17) (110) (330) (267) 125 (587) (651) (533) (351) (746) (548) (368) (165) (222) (98) (441) (17) (110) (330) (267) 150, 175, 200 (511) (970) (406) (584) (1,067) (899) (216) (210) (138) (165) (652) (35) (208) (564) (416) 225, 250 (664) (970) (559) (584) (1,067) (899) (332) (224) (229) (165) (652) (35) (208) (564) (397) 300, 350, 400 (867) (1,041) (762) (584) (1,067) (899) (433) (229) (300) (186) (703) (35) (208) (564) (411) CLEARANCES FROM COMBUSTIBLES Form RZ-C-UH (Version H) Page 10 Top Flue Connector Access Panel Non-Access Side Bottom* Rear Size inches mm inches mm inches mm inches mm inches mm inches mm 30-125 1 25 6 152 18 457 1 25 1 25 18 457 150-400 4 102 6 152 18 457 2 51 1 25 18 457 *Suspend the heater so that the bottom is a minimum of 5 (1.5M) above the floor.