Solicitation No.: The enclosed addendum amends the bid documents for the above referenced Project.

Similar documents
DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM

IN2 Digital, Addressable Fire-alarm System

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Lake County / Multi-Department Storage Facility / Project / December 12, 2016 SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

A. Provide addressable fire alarm system throughout the facility and supervise wet and preaction fire sprinkler system.

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Addendum # 2 Wicomico County Circuit Court Second Floor Renovations Date of Addendum: 2/6/2017

SECTION FIRE ALARM

HARRIS COUNTY HOUSING AUTHORITY

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION FIRE ALARM SYSTEMS

SECTION COMMON WORK RESULTS FOR SAFETY AND SECURITY 1.1 RELATED SECTIONS

SECTION FIRE ALARM INTEGRATED AUDIO VISUAL EMERGENCY COMMUNICATION SYSTEM

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM

LEA COUNTY NEW MEXICO Page 1 of 8 JUDICIAL COMPLEX RFP NO.: 03-(16-17)

Item No. Description 1. BID PROPOSAL FORM Make the following revisions: a. Replace the BID PROPOSAL FORM with the attached BID PROPOSAL FORM.

FIRE & LIFE SAFTEY STANDARD

SECTION AUTOMATIC TRANSFER SWITCHES

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S.

COMMISSION ORDER. IT IS FURTHER ORDERED that the Request for Bid and Notice to Bidders be displayed on the Franklin County website.

Copyright 2013 Fike 12/13 SECTION CLEAN-AGENT FIRE-EXTINGUISHING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

Fire Alarm System Fundamentals

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

ADDENDUM #1: MODIFICATIONS AND ADDITIONS TO CONTRACT DOCUMENTS

Ventura County Community College District 761 E. Daily Drive, West Stanley Avenue, St. 200, Camarillo, CA Purchasing Department

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

New Auburn University Veterinary Facility Gulf Shores, AL

SECTION GENERATOR PARALLELING CONTROLS

1. Delete BID FORM in its entirety and replace with the BID FORM attached to this Addendum.

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

CITY OF PORTSMOUTH Department of Public Works MUNICIPAL COMPLEX FIRE ALARM. Bid # Addendum #1

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

DONALD H. BERG, ARCHITECT

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE, 2000 EDITION SECTIONS

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE

The following information shall become and form part of the contract documents.

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM

Bold items are particular to the City of Euless

Full Service Central Station Fire Alarm Listing Evaluation

Unified Fire Authority - Fire Prevention Bureau

SECTION SECURITY TESTING AND COMMISSIONING

SUWANNEE RIVER WATER MANAGEMENT DISTRICT REQUEST FOR BID NO. 15/16-003AO FIRE ALARM SYSTEM INSTALLATION AND MONITORING.

SECTION WET-PIPE SPRINKLER SYSTEMS

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

SECTION ENCLOSED CONTROLLERS

SECTION : FIRE ALARM & DETECTION SYSTEMS

SECTION DRY-PIPE SPRINKLER SYSTEMS

Please make the following additions/changes/clarifications to the above referenced project:

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

Changes in NFPA

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

PROJ. NO SECTION PAGING, SPEAKERS AND HARD-WIRED CLOCK SYSTEMS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

SECTION FIRE ALARM SYSTEMS

Minimum Standards for Engineers Practicing Fire Protection Engineering in the State of Oklahoma September 14, 2016

FIRE SUPPRESSION SPRINKLER SYSTEM

Port of St Helens SIA Aircraft Hanger Scappoose, OR

SECTION ISOLATED POWER SYSTEMS

Sidney, Ohio 1204 FORMAL ISSUANCE OF CERTIFICATE OF SUBSTANTIAL COMPLETION... ON OR BEFORE JULY 30, 2015.

SECTION FAN COIL UNITS

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

Michigan State University Construction Standards FIRE DETECTION AND ALARM PAGE

COLUMBIA PUBLIC SCHOOLS HVAC IMPROVEMENTS - PHASE COLUMBIA, MISSOURI

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

Rocky Mountain Fire Protection District 4390 Eldorado Springs Drive Boulder, CO

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

ADDENDUM #2 DSA Appl. #

1.3 REFERENCE STANDARDS

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

CONTENTS AUTOMATIC TRANSFER SWITCHES

FIRE ALARM SYSTEM 1.1 GENERAL REQUIREMENTS

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

SECTION TOTAL FLOODING ECARO-25 CLEAN AGENT FIRE EXTINGUISHING SYSTEM

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

ADDENDUM NO. 1. for. MARQUETTE HOUSING COMMISSION Pine Ridge Apartments Fire Alarm Replacement Project #A1140. Marquette, Michigan.

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION ADDRESSABLE FIRE ALARM SYSTEM

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

SECTION Overhead Coiling Doors

COUNTY OF KINGS KINGS COUNTY JAIL EXPANSION PHASE III

Milford High School Fire Alarm MILFORD SCHOOL DISTRICT BID GOOD FAITH STATEMENT

Emery County Senior Center Green River 06/07

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

SECTION AIR DOORS

SECTION GAS-FIRED RADIANT HEATERS

NASSAU COUNTY FIRE PROTECTION PERMIT APPLICATION

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

Transcription:

Date: September 14, 2018 Project: AlDEA/AEA Noise Control Tenant Improvement Solicitation No.: 19003 Addendum No. One TO ALL PLANHOLDERS: The enclosed addendum amends the bid documents for the above referenced Project. Acknowledgment of this addendum is required on the Proposal Form. Failure to do so may subject the bidder to disqualification. Sincere!, / ~-<--~-- Contracting Officer

ADDENDUM TO CONTRACT DOCUMENTS Page Number No. of Pages I 14 (including cover & attachments} Addendum No. ONE Date Addendum Issued: September 14,2018 Issuing Office Previous Addenda Issued Jake Tibbe Alaska Industrial Development & Export Authority N/A 813 W Northem Lights Blvd Anchorage, AK 99503 Phone: (907) 771-3990 Fax: (907) 771-3044 Project: AlDEAIAEA Noise Control Tenant Improvement Date and Hour Quotes Due: September 28, 2018 at 2:00 Solicitation No.: 19003 p.m., prevailing Anchorage, Alaska time. NOTICE TO BIDDERS: Bidders must acknowledge receipt of this addendum prior to the hour and date set for the bid due date by one of the following methods: (a) By acknowledging receipt of this addendum on the proposal form submitted. (b) By email or teletacsimile which includes a reference to the project and addendum number. The bid documents require acknowledgment individually of all addenda to the drawings and/or specifications. l11is is a mandatory requirement and any bid received without acknowledgment of receipt of addenda may be classified as not being a responsive bi d. If, by virtue of this addendum it is desired to modify a bid already submitted, such modification may be made by email or telefacsimile provided such an email or telefacsimile makes reference to this addendum and is received prior to the opening hour and date specified above. ************************************************************************************************************** The Bid documents for the above project are amended as follows (All other tenns and conditions remain unchanged): 1) Q: Is a pre-bid meeting scheduled? GENERAL- QUESTIONS & ANSWERS A: Yes, please see ' Special Notice to Bidders' (page 12 of the AS-ADVERTISED Project Manual). 2) Q: What is the existing fue alarm system? A: The existing fire alarm system is an Edwards FSP502GD. Through clarification from the fire alarm servicing company, it has been noted that the fire alarm system is of the conventional type. 3) Q: What is the amount of the Liquidated Damages per day for the project? A: Liquidated Damages are not being applied to this project. BIDDING AND CONTRACT REQUIREMENTS 4) Section 00 02 00 - Invitation to Bid, replace "All work shall be substantially completed by: December 12, 2018" with the following: "All work shall be substantially completed by: January 16, 2019" PROJECT MANUAL 5) PROPOSAL. Remove and replace with Attachment No.1.

Page 2 of2 September 14, 2018 Addendum No. 1 CONTRACT PROVISIONS AND SPECIFICATIONS 6) Section 28 46 21.11. Remove Section 28 46 21.11 ' Addressable Fire-Alarm Systems' and replace with Attachment No.2 Section 28 46 21.13 "Conventional Fire-Alarm Systems". PLANS/DRAWINGS 7) Sheet S 10 I Detail 1: Delete callout lis 501 at Grid 2 just above Grid C; and delete the"+ VERSALAM 3 1/2 X 20" with the associated heavy line at Grid 2 between C and D, at Grid 2 between A.3 and B, and at Grid 3 between C and D. 8) Sheet S501 Detail 1: Delete this detail. 9) Sheet S50 I Detail 2: Modify as shown in SKS-0 1 (Attachment No. 3). 1 0) Sheet A 10 I, Detail 1: Delete Keynote 16 at Grids 2 & 3 between Grids C & D. II) Sheet A l02, Detail2: Delete Keynote 16 at Grid 2 between Grids C & D. 12) Sheet AI 03, Detail 1: Delete Keynote 16 at Grids 2 & 3 between Grids C & D. 13) Sheet A201, Detail 1 & 3: Delete Keynote 16 at 2nd FLR between Grids C & D. 14) Sheet A202, Detail 1: Delete Keynote 16 at 2nd FLR at Grid 2 & at Grid 3. 15) Sheet A202, Detail 2: Delete Keynote 16 at 2nd FLR between Grid A.3 & B. END OF ADDENDUM

Addendum No. 1 ~------------------------------------------Attachment No.1 ALASKA INDUSTRIAL DEVELOPMENT EXPORT AUTHORITY NAME ADDRESS PROPOSAL of To the CONTRACTING OFFICER, ALASKA INDUSTRIAL DEVEWPMENT EXPORT AUTHORITY: In compliance with your Invitation To Bid dated September 7, 2018, the Undersigned proposes to fumish and deliver all the materials and do all the work and labor required in the construction of Project: AIDEA/ AEA Noise Control Tenant Improvement Project No. 19003 Located at Anchorage, Alaska, according to the plans and specifications and for the amount and ptices named herein as indicated on the Bid Schedule consisting of 2 sheet(s). which is made a part of this Bid. The Undersigned declares that he has carefully examined the contract requirements and that he has made a personal examination of the site of the work; that he understands that the quantities, where such are specified in the Bid Schedule or on the plans for this project, are approximate only and subject to increase or decrease, and that he is willing to perform increased or decreased quantities of work at unit prices bid under the conditions set forth in the Contract Documents. The Undersigned hereby agrees to execute the said contract and bonds within fifteen calendar days, or such further time as may be allowed in writing by the Contracting Officer, after receiving notification of the acceptance of this proposal, and it is hereby mutually understood and agreed that in case the Undersigned does not, the accompanying bid guarantee shall be forfeited to the Alaska Industrial Development Export Authority, as liquidated damages, and the said Contracting officer may proceed to award the contract to others. The Undersigned agrees to commence the work within 10 calendar days after the effective date of Notice to Proceed and to substantially complete the work by January 16, 2019, unless extended in writing by the Contracting Officer. Final inspection and completion shall be on or before January 23, 2019 unless extended in writing by the Contracting Officer. The Undersigned proposes to furnish Payment Bond in the amount of 50% (of the contract) and Performance Bond in the amount of 50% (of the contract}, as surety conditioned for the full, complete and faithful performance of this contract. Form 25D-9A (07 / 03) 00 31 00 Page l of2

The Undersigned acknowledges receipt of the following addenda to the drawings and/or specifications (give number and date of each). Addendum Date Addendum Date Addendum Date Number Issued Number Issued Number Issued NON-COLLUSION AFFIDAVIT The Undersigned declares, under penalty of perjury under the laws of the United States, that neither he nor the firm, association, or corporation of which he is a member, has, either directly or indirectly, entered into any agreement, participated in any collusion, or otherwise taken any action in restraint of free competitive bidding in connection with this bid. The Undersigned has read the foregoing proposal and hereby agrees to the conditions stated therein by affixing his signature below: Signature Name and Title of Person Signing Telephone Number Email Form 25D-9A (07 /03) 00 31 00 Page 2 of2

AIDEAJAEA NOISE CONTROL TENANT IMPROVEMENT Addendum No 1 Attachment No. 2 SECTION 28 46 21.13 CONVENTIONAL FIRE-ALARM SYSTEMS PART 1 -GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.02 SUMMARY A. Section Includes: 1. Fire-alarm control unit. 2. Manual fire-alarm boxes. 3. System smoke detectors. 4. Air-sampling smoke detectors. 5. Nonsystem smoke detectors. 6. Heat detectors. 7. Notification appliances. 8. Device guards. 9. Firefighters' two-way telephone communication service. 10. Firefighters' smoke-control station. 11. Magnetic door holders. 12. Remote annunciator. 13. Graphic annunciator. 14. Digital alarm communicator transmitter. 15. Radio alarm transmitter. 16. System printer. B. Related Requirements: 1. Section 270513 "Conductors and Cables for Communications Systems" for cables and conductors for fire-alarm systems. 1.03 DEFINITIONS A. EMT: Electrical Metallic Tubing. B. FACP: Fire Alarm Control Panel. C. NICET: National Institute for Certification in Engineering Technologies. D. VESDA: Very Early Smoke Detection Apparatus. AIDEAIAEA NOISE CONTROL TENANT IMPROVEMENT Section 28 46 21.13 - Page 1-8

AIDEAIAEA NOISE CONTROL TENANT IMPROVEMENT 1.04 ACTION SUBMITTALS A. General Submittal Requirements: 1. Submittals shall be approved by authorities having jurisdiction prior to submitting them to Architect. 2. Shop Drawings shall be prepared by persons with the following qualifications: a. Trained and certified by manufacturer in fire-alarm system design. b. Licensed or certified by authorities having jurisdiction. B. Product Data: For each type of product, including furnished options and accessories. 1. Include construction details, material descriptions, dimensions, and profiles and finishes. 2. Include rated capacities, operating characteristics, and electrical characteristics. C. Shop Drawings: For fire-alarm system. 1. Comply with recommendations and requirements in the "Documentation" section of the "Fundamentals" chapter in NFPA 72. 2. Include plans, elevations, sections, details, and attachments to other work. 3. Include details of equipment assemblies. Indicate dimensions, weights, loads, required clearances, method of field assembly, components, and locations. Indicate conductor sizes, indicate termination locations and requirements, and distinguish between factory and field wiring. 4. Detail assembly and support requirements. 5. Include voltage drop calculations for notification-appliance circuits. 6. Include statement from manufacturer that all equipment and components have been tested as a system and meet all requirements in this Specification and in NFPA 72. 7. Include performance parameters and installation details for each detector. 8. Verify that each duct smoke detector is listed for the complete range of air velocity, temperature, and humidity possible when air-handling system is operating. 9. Provide program report showing that air-sampling detector pipe layout balances pneumatically within the airflow range of the air-sampling detector. 1.05 INFORMATIONAL SUBMITTALS A. Qualification Data: For Installer. B. Seismic Qualification Data: Certificates, for fire-alarm control unit, accessories, and components, from manufacturer. 1. Basis for Certification: Indicate whether withstand certification is based on actual test of assembled components or on calculation. 2. Dimensioned Outline Drawings of Equipment Unit: Identify center of gravity and locate and describe mounting and anchorage provisions. 3. Detailed description of equipment anchorage devices on which the certification is based and their installation requirements. C. Field quality-control reports. D. Sample Warranty: For special warranty. AIDEAIAEA NOISE CONTROL TENANT IMPROVEMENT Section 28 46 21.13- Page 2-8

AIDEAIAEA NOISE CONTROL TENANT IMPROVEMENT 1.06 QUALITY ASSURANCE A. Installer Qualifications: Personnel shall be trained and certified by manufacturer for installation of un its required for this Project. B. NFPA Certification: Obtain certification according to NFPA 72 by an NRTL (nationally recognized testing laboratory). C. NFPA Certification: Obtain certification according to NFPA 72 by a UL-Iisted alarm company. D. NFPA Certification: Obtain certification according to NFPA 72 in the form of a placard by an FM Global-approved alarm company. 1.07 PROJECT CONDITIONS A. Perform a full test of the existing system prior to starting work. Document any equipment or components not functioning as designed. B. Interruption of Existing Fire-Alarm Service: Do not interrupt fire-alarm service to facilities occupied by Owner or others unless permitted under the following conditions and then only after arranging to provide temporary guard service according to requirements indicated: 1. Notify Owner no fewer than seven days in advance of proposed interruption of fire-alarm service. 2. Do not proceed with interruption of fire-alarm service without Owner's written permission. C. Use of Devices during Construction : Protect devices during construction unless devices are placed in service to protect the facility during construction. 1.08 SEQUENCING AND SCHEDULING A. Existing Fire-Alarm Equipment: Maintain existing equipment fully operational until new equipment has been tested and accepted. As new equipment is installed, label it "NOT IN SERVICE" until it is accepted. Remove labels from new equipment when put into service, and label existing firealarm equipment "NOT IN SERVICE" until removed from the building. B. Equipment Removal: After acceptance of new fire-alarm system, remove existing disconnected fire-alarm equipment and wiring. 1.09 WARRANTY A. Special Warranty: Manufacturer agrees to repair or replace fire-alarm system equipment and components that fail in materials or workmanship within specified warranty period. 1. Warranty Extent: All equipment and components not covered in the Maintenance Service Agreement. 2. Warranty Period: Five years from date of Substantial Completion. AIDEAIAEA NOISE CONTROL TENANT IMPROVEMENT Section 28 46 21.13 - Page 3-8

AIDEAIAEA NOISE CONTROL TENANT IMPROVEMENT PART 2 - PRODUCTS 2.01 SYSTEM DESCRIPTION A. Source Limitations for Fire-Alarm System and Components: Components shall be compatible with and operate as an extension of existing system. Provide system manufacturer's certification that all components provided have been tested as, and will operate as, a system. The existing fire alarm system is an Edwards FSP502GD. B. Noncoded system dedicated to fire-alarm service only. C. All components provided shall be listed for use with the selected system. D. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application. 2.02 SYSTEMS OPERATIONAL DESCRIPTION A. Fire-alarm signal initiation shall be by one or more of the following devices: 1. Manual stations. 2. Heat detectors. 3. Smoke detectors. 4. Duct smoke detectors. 5. Automatic sprinkler system water flow. 2.03 PERFORMANCE REQUIREMENTS A. Seismic Performance: Fire-alarm control unit and raceways shall withstand the effects of earthquake motions determined according to ASCE/SEI 7. 1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces specified. 2.04 MANUAL FIRE-ALARM BOXES A. General Requirements for Manual Fire-Alarm Boxes: Comply with UL 38. Boxes shall be finished in red with molded, raised-letter operating instructions in contrasting color; shall show visible indication of operation; and shall be mounted on recessed outlet box. If indicated as surface mounted, provide manufacturer's surface back box. 1. Single-action mechanism, pull-lever type. 2. Station Reset: Key- or wrench-operated switch. 3. Indoor Protective Shield: Factory-fabricated, clear plastic enclosure hinged at the top to permit lifting for access to initiate an alarm. Lifting the cover actuates an integral batterypowered audible horn intended to discourage false-alarm operation. 4. Weatherproof Protective Shield: Factory-fabricated, clear plastic enclosure hinged at the top to permit lifting for access to initiate an alarm. AIDEAIAEA NOISE CONTROL TENANT IMPROVEMENT Section 28 46 21.13 - Page 4-8

AIDEA/AEA NOISE CONTROL TENANT IMPROVEMENT 2.05 SYSTEM SMOKE DETECTORS A. General Requirements for System Smoke Detectors: 1. Operating at 24-V de, nominal. 2. Detectors shall be two wire type. 3. Base Mounting: Detector and associated electronic components shall be mounted in a twist-lock module that connects to a fixed base. Provide terminals in the fixed base for connection to building wiring. 4. Self-Restoring: Detectors do not require resetting or readjustment after actuation to restore them to normal operation. 5. Integral Visual-Indicating Light: LED type, indicating detector has operated. 6. Provide multiple levels of detection sensitivity for each sensor. B. Photoelectric Smoke Detectors: Comply with UL 268. C. Ionization Smoke Detector: Comply with UL 268. D. Duct Smoke Detectors: Photoelectric type complying with UL 268A. 1. Remote indication station. 2. Weatherproof Duct Housing Enclosure: NEMA 250, Type 4X; NRTL listed for use with the supplied detector for smoke detection in HVAC system ducts. 3. Sampling Tubes: Design and dimensions as recommended by manufacturer for specific duct size, air velocity, and installation conditions where applied. 4. Relay Fan Shutdown: Rated to interrupt fan motor-control circuit. 2.06 NOTIFICATION APPLIANCES A. General Requirements for Notification Appliances: Connected to notification-appliance signal circuits, zoned as indicated, equipped for mounting as indicated, and with screw terminals for system connections. 1. Combination Devices: Factory-integrated audible and visible devices in a singlemounting assembly, equipped for mounting as indicated, and with screw terminals for system connections. B. Chimes, High-Level Output: Vibrating type, 81-dBA minimum rated output. C. Horns: Electric-vibrating-polarized type, 24-V de; with provision for housing the operating mechanism behind a grille. Comply with UL 464. Horns shall produce a sound-pressure level of 90 dba, measured 10 feet from the horn, using the coded signal prescribed in UL 464 test protocol. D. Visible Notification Appliances: Xenon strobe lights complying with UL 1971, with clear or nominal white polycarbonate lens mounted on an aluminum faceplate. The word "FIRE" is engraved in minimum 1-inch-high letters on the lens. 1. Rated Light Output: a. 15/30/75/1 10 cd, selectable in the field. 2. Mounting: Wall mounted unless otherwise indicated. AIDEAIAEA NOISE CONTROL TENANT IMPROVEMENT Section 28 46 21.13- Page 5-8

AIDEAIAEA NOISE CONTROL TENANT IMPROVEMENT 3. For units with guards to prevent physical damage, light output ratings shall be determined with guards in place. 4. Flashing shall be in a temporal pattern, synchronized with other units. 5. Strobe Leads: Factory connected to screw terminals. 6. Mounting Faceplate: Factory finished, red. PART 3 - EXECUTION 3.01 EXAMINATION A. Examine areas and conditions for compliance with req uirements for ventilation, temperature, humidity, and other conditions affecting performance of the work. 1. Verify that manufacturer's written instructions for environmental conditions have been permanently established in spaces where equipment and wiring are installed, before installation begins. B. Examine roughing-in for electrical connections to verify actual locations of connections before installation. C. Proceed with installation only after unsatisfactory conditions have been corrected. 3.02 EQUIPMENT INSTALLATION A. Comply with NFPA 72, NFPA 101, and requirements of authorities having jurisdiction for installation and testing of fire-alarm equipment. Install all electrical wiring to comply with requirements in NFPA 70 including, but not limited to, Article 760, "Fire Alarm Systems." B. Connecting to Existing Equipment: Verify that existing fire-alarm system is operational before making changes or connections. 1. Connect new equipment to the existing control panel in the existing part of the building. 2. Connect new equipment to the existing monitoring equ ipment at the supervising station. 3. Expand, modify, and supplement the existing monitoring and control equipment as necessary to extend the existing monitoring and control functions to the new points. New components shall be capable of merging with the existing configuration without degrading the performance of either system. C. Manual Fire-Alarm Boxes: 1. Install manual fire-alarm box in the normal path of egress within 60 inches of the exit doorway. 2. Mount manual fire-alarm box on a background of a contrasting color. 3. The operable part of manual fire-alarm box shall be between 42 inches and 48 inches above floor level. All devices shall be mounted at the same height unless otherwise indicated. D. Install a cover on each smoke detector that is not placed in service during construction. Cover shall remain in place, except during system testing. Remove cover prior to system turnover. E. Duct Smoke Detectors: Comply with NFPA 72 and NFPA 90A. Install sampling tubes so they extend the full width of duct. Tubes more than 36 inches long shall be supported at both ends. AIDEA/AEA NOISE CONTROL TENANT IMPROVEMENT Section 28 46 21.13- Page 6-8

AIDEAIAEA NOISE CONTROL TENANT IMPROVEMENT 1. Do not install smoke detector in duct smoke-detector housing during construction. Install detector only during system testing and prior to system turnover. F. Remote Status and Alarm Indicators: Install in a visible location near each smoke detector, sprinkler water-flow switch, and valve-tamper switch that is not readily visible from normal viewing position. G. Audible Alarm-Indicating Devices: Install not less than 6 inches below the ceiling. Install bells and horns on flush-mounted back boxes with the device-operating mechanism concealed behind a grille. Install all devices at the same height unless otherwise indicated. H. Visible Alarm-Indicating Devices: Install adjacent to each alarm bell or alarm horn and at least 6 inches below the ceiling. Install all devices at the same height unless otherwise indicated. 3.03 PATHWAYS A. Pathways above recessed ceilings and in non-accessible locations may be routed exposed. 1. Exposed pathways located less than 96 inches above the floor shall be installed in EMT. B. Pathways shall be installed in EMT. C. Exposed EMT shall be painted red enamel. 3.04 GROUNDING A. Ground fire-alarm control unit and associated circuits; comply with IEEE 1100. B. Ground shielded cables at the control panel location only. Insu late sh ield at device location. 3.05 FIELD QUALITY CONTROL A. Field tests shall be witnessed by authorities having jurisdiction. B. Manufacturer's Field Service: Engage a factory-authorized service representative to test and inspect components, assemblies, and equipment installations, including connections. C. Perform the following tests and inspections 1. Visual Inspection : Conduct the visual inspection prior to testing. a. Inspection shall be based on completed record Drawings and system documentation that is required by NFPA 72 in Chapter 10 "Fundamentals," Section 10.18.21 "Completion Documents, Preparation." b. Comply with NFPA 72, Chapter 14, "Inspection, Testing, and Maintenance," Section 14.3, "Inspection" and the "Visual Inspection Frequencies" Table; retain the "Initial/Reacceptance" column and list only the installed components. 2. System Testing: Comply with NFPA 72, Chapter 14, "Inspection, Testing, and Maintenance," Section 14.4 'Testing" and the "Test Methods" Table. AIDEAIAEA NOISE CONTROL TENANT IMPROVEMENT Section 28 46 21.13 - Page 7-8

AIDEAIAEA NOISE CONTROL TENANT IMPROVEMENT 3. Test audible appliances for the public operating mode according to manufacturer's written instructions. Perform the test using a portable sound-level meter complying with Type 2 requirements in ANSI S1.4. 4. Test visible appliances for the public operating mode according to manufacturer's written instructions. 5. Factory-authorized service representative shall prepare the "Fire Alarm System Record of Completion" in the "Documentation" section of the "Fundamentals" chapter in NFPA 72 and the "Inspection and Testing Form" in the "Records" section of the "Inspection, Testing and Maintenance" chapter in NFPA 72. D. Reacceptance Testing: Perform reacceptance testing to verify the proper operation of added or replaced devices and appliances. E. Fire-alarm system will be considered defective if it does not pass tests and inspections. F. Prepare test and inspection reports. G. Maintenance Test and Inspection: Perform tests and inspections listed for weekly, monthly, quarterly, and semiannual periods. Use forms developed for initial tests and inspections. H. Annual Test and Inspection: One year after date of Substantial Completion, test fire-alarm system complying with the visual and testing inspection requirements in NFPA 72. Use forms developed for initial tests and inspections. 3.06 MAINTENANCE SERVICE A. Initial Maintenance Service: Beginning at Substantial Completion, maintenance service shall include 12 months' full maintenance by skilled employees of manufacturer's designated service organization. Include preventive maintenance, repair or replacement of worn or defective components, lubrication, cleaning, and adjusting as required for proper operation. Parts and supplies shall be manufacturer's authorized replacement parts and supplies. 1. Include visual inspections according to the 'Visual Inspection Frequencies" table in the "Testing" paragraph of the "Inspection, Testing and Maintenance" chapter in NFPA 72. 2. Perform tests in the "Test Methods" table in the "Testing" paragraph of the "Inspection, Testing and Maintenance" chapter in NFPA 72. 3. Perform tests listed in the "Testing Frequencies" table in the "Testing" paragraph of the "Inspection, Testing and Maintenance" chapter in NFPA 72. END OF SECTION AIDEAIAEA NOISE CONTROL TENANT IMPROVEMENT Section 28 46 21.13 - Page 8-8

~-----------------------------------------Addendum No. 1 Attachment No. 3 BEAM LEG HANGER 4-3/4" BOLTS TO GL8 3/4 2-3/4" BOLTS TO GL3 1/8 - ------. _,------- PLYWOOD WHERE OCCURS ~- (E) 3x DECKING I I I e I I I GL3 1/8, "----- -- (E) GL8 3/4 ~ ~g~efrs~. 845 K Slfeel Anchorage. AJ< 9eS01 1949 Phone: (907) 27 2238 Fax: 27<4-2520 Corporate Authentication No: C72S RlM Pl'lcnt. 4151 47J400 WWWJIII*thiiiK:ts.tOIII PROJECT TITLE: AIDEA NOISE CONTROL TENANT IMPROVEMENT ADDRESS: 813 W NORTHERN LIGHTS BLVD, ANCHORAGE AK 99503 OWNER: ALASKA INDUSTRIAL DEVELOPMENT AND EXPORT AUTHORITY SHEET TITLE: 2/S501 ISSUE DATE : 2018.09.10 PROJECT NO : 161002.103 DRAWN BY : JWC CHECKED BY : DLB COPYRIGHT : 2017 RIM ARCHITECTS DOCUMENT REF NO: 2/S501 DWG NO: SKS-01