B. Shop Drawings: For fire protection cabinets. Include plans, elevations, sections, details, and attachments to other work.

Similar documents
TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

SECTION FIRE EXTINGUISHER CABINETS

1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES

Shop Drawings: For fire protection cabiaets, lnclode plans, elevations, sections, details, and attachments to other work.

ADDENDUM #1: MODIFICATIONS AND ADDITIONS TO CONTRACT DOCUMENTS

1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for detention furniture.

B. Product Schedule: For appliances. Use same designations indicated on Drawings.

1. Vinyl wall covering. 2. Woven glass-fiber wall covering. 3. Textile wall covering. 4. Wallpaper. 5. Heavy-duty, synthetic, textile wall covering.

Consult the manufacturer for assistance in editing this guide specification for specific Project applications where necessary.

EXAMPLE SPECIFICATION ONLY

A. Provide products and workmanship in accordance to: (Where applicable)

DIVISION 10 SPECIALTIES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

A. Section includes ground-mounted flagpoles made from aluminum.

SECTION AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER

RESIDENTIAL APPLIANCES DIVISION 11 - EQUIPMENT PN A

SECTION IDENTIFYING DEVICES

SECTION FIRE-RATED GLASS AND FRAME

c. Oko-Tex (European environmental health standard)

A. Section Includes: Fire extinguishers and cabinets including necessary accessories.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

University of Missouri St. Louis UMSL Project #S7628 Campus Police Building Building Modifications & Renovations R&B Project # Building Upgrades

WALLCOVERINGS WALLCOVERINGS

PART 1 GENERAL 1.01 SUMMARY

A. This Section includes the following emergency plumbing fixtures:

GUIDE SPECIFICATION Los Angeles World Airports SECTION TOILET COMPARTMENTS

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperLite TM I-XL minute SuperLite TM I-XL IGU minute PART 1 GENERAL

Springpoint Architects, pc SECTION Childcare Center Architect s Project No TABLE OF CONTENTS Monroe County Comm. Sch. Corp.

1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - "Systems and Equipment.

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

SECTION Overhead Coiling Doors

B. Manufacturer s color charts consisting of actual units or section of units showing the full range of colors available for the following:

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories for each type of product indicated.

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

Construction Standards Page

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

SECTION ELECTRICAL IDENTIFICATION

University of Rochester October 17, 2008 Brooks Landing Business Center

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Temperature Rise Door Framing

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

FIRE SUPPRESSION SPRINKLER SYSTEM

ARBOR SERIES WOOD WALLCOVERINGS

PART 1 GENERAL 1.01 SUMMARY

PART 1 GENERAL 1.01 SUMMARY

PART 1 GENERAL 1.01 SUMMARY

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

Richmond Hill Primary Renovation SECTION STAGE CURTAINS

SECTION (15767) - UNIT HEATERS

ARBOR SERIES DIVISION FLEXIBLE WOOD VENEER WALLCOVERING

ARCHITECTURAL SPECIFICATIONS

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

Hinesville First United Methodist Church SECTION RESIDENTIAL APPLIANCES

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

SECTION ENCLOSED CONTROLLERS

B. Shop Drawings: Details of electrified door hardware, including wiring diagrams.

ASI Guide Specification

Linear Floor Heaters

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

E. Luminaire: Complete lighting fixture, including ballast housing if provided.

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code. B. ARI Commercial and Industrial Humidifiers.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Product Guide Specification

SECTION INTERIOR LIGHTING

Copyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load centers.

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

Product Guide Specification

Element C Interiors Interior Construction

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperClear 45-HS (patent pending)

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

B. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.

SECTION (09950) - WALL COVERINGS

Emery County Senior Center Green River 06/07

SECTION XPRESS II INCLINED WHEELCHAIR PLATFORM LIFT. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

Michigan State University Construction Standards COMMISSIONING OF FIRE ALARM SYSTEMS PAGE

SECTION AIR DUCT ACCESSORIES

SECTION ELECTRIC WATER HEATERS

Transcription:

PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. B. The Contractor's attention is specifically directed, but not limited, to the following documents for additional requirements: 1. Uniform General Conditions for Construction Contracts, State of Texas, 2010 (UGC). 2. The University of Houston s Supplemental General Conditions and Special Conditions for Construction. 1.2 SUMMARY A. Section Includes: 1. Fire protection cabinets for the following: 1.3 ACTION SUBMITTALS a. Portable fire extinguishers. b. Fire hose valves. c. Fire hoses and racks. A. Product Data: For each type of product indicated. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for fire protection cabinets. 1. Fire Protection Cabinets: Include roughing-in dimensions, details showing mounting methods, relationships of box and trim to surrounding construction, door hardware, cabinet type, trim style, and panel style. 2. Show location of knockouts for hose valves. B. Shop Drawings: For fire protection cabinets. Include plans, elevations, sections, details, and attachments to other work. C. Samples for Verification: For each type of exposed finish required, prepared on Samples of size indicated below: 1. Size: 6 by 6 inches square. D. Product Schedule: For fire protection cabinets. Coordinate final fire protection cabinet schedule with fire extinguisher schedule to ensure proper fit and function. 1.4 CLOSEOUT SUBMITTALS A. Maintenance Data: For fire protection cabinets to include in maintenance manuals. AE Project #: <%Project Number%> Fire Extinguisher Cabinets 10 44 13-1

1.5 QUALITY ASSURANCE A. Fire-Rated, Fire Protection Cabinets: Listed and labeled to comply with requirements in ASTM E 814 for fire-resistance rating of walls where they are installed. B. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application. 1.6 COORDINATION A. Coordinate size of fire protection cabinets to ensure that type and capacity of fire extinguishers indicated are accommodated. B. Coordinate sizes and locations of fire protection cabinets with wall depths. PART 2 - PRODUCTS 2.1 MATERIALS A. Tempered Break Glass: ASTM C 1048, Kind FT, Condition A, Type I, Quality q3, 1.5 mm thick. B. Transparent Acrylic Sheet: ASTM D 4802, Category A-1 (cell-cast sheet), 1.5 mm thick, with Finish 1 (smooth or polished). 2.2 FIRE PROTECTION CABINET (Typical Installation <Insert drawing designation>) A. Cabinet Type: Suitable for fire extinguisher. 1. Basis of Design: Subject to compliance with requirements, provide fully recessed, stainless steel, solid door, Architectural Series, fire extinguisher cabinet by Larsen's Manufacturing Company; www.larsensmfg.com or comparable product by one of the following: a. J. L. Industries, Inc., a division of Activar Construction Products Group; Cosmopolitan Series; www.jlindustries.com. b. Modern Metal Products, Division of Technico Inc.; www.modern-metal.com. c. Substitutions: See Section 01 25 00 - Substitution Procedures. B. Cabinet Construction: Nonrated. C. Cabinet Material: Stainless-steel sheet. 1. Shelf: Same metal and finish as cabinet. D. Recessed Cabinet: Cabinet box recessed in walls of sufficient depth to suit style of trim indicated. 1. Exposed Flat Trim: One-piece combination trim and perimeter door frame overlapping surrounding wall surface with exposed trim face and wall return at outer edge (backbend). AE Project #: <%Project Number%> Fire Extinguisher Cabinets 10 44 13-2

E. Cabinet Trim Material: Same material and finish as door. F. Door Material: Stainless-steel sheet. G. Door Style: Solid opaque panel with frame. H. Door Hardware: Manufacturer's standard door-operating hardware of proper type for cabinet type, trim style, and door material and style indicated. 1. Provide manufacturer's standard. 2. Provide [continuous hinge, of same material and finish as trim,] permitting door to open 180 degrees. I. Accessories: 1. Identification: Lettering complying with authorities having jurisdiction for letter style, size, spacing, and location. Locate as directed by Architect. J. Finishes: a. Identify fire extinguisher in fire protection cabinet with the words "FIRE EXTINGUISHER." 1) Location: Applied to cabinet door. 2) Application Process: Pressure-sensitive vinyl letters. 3) Lettering Color: Black. 4) Orientation: Vertical. 1. Manufacturer's standard baked-enamel paint for the following: a. Interior of cabinet. 2. Stainless Steel: No. 4. 2.3 FIRE PROTECTION CABINETS (Areas exposed to the elements and/or chemicals <Insert drawing designation>) A. Cabinet Type: Suitable for fire extinguisher. 1. Basis of Design: Subject to compliance with requirements, provide the following: fiberglass cabinets, manufactured by Thomas Products, www.thomasproducts.com. a. Substitutions: See Section 01 25 00 - Substitution Procedures. B. Cabinet Construction: Nonrated. C. Cabinet Material: molded fiberglass. D. Recessed Cabinet: Cabinet box recessed in walls of sufficient depth to suit style of trim indicated. 1. Exposed Flat Trim: One-piece combination trim and perimeter door frame overlapping surrounding wall surface with exposed trim face and wall return at outer edge (backbend). AE Project #: <%Project Number%> Fire Extinguisher Cabinets 10 44 13-3

E. Semirecessed Cabinet: Cabinet box partially recessed in walls of sufficient depth to suit style of trim indicated; with one-piece combination trim and perimeter door frame overlapping surrounding wall surface with exposed trim face and wall return at outer edge (backbend). Provide where walls are of insufficient depth for recessed cabinets but are of sufficient depth to accommodate semirecessed cabinet installation. F. Surface-Mounted Cabinet: Cabinet box fully exposed and mounted directly on wall with no trim. Provide where walls are of insufficient depth for semirecessed cabinet installation. G. Cabinet Trim Material: Same material and finish as door. H. Door Material: Same material as cabinet. I. Door Style: Center glass panel with frame. J. Door Hardware: Manufacturer's standard door-operating hardware of proper type for cabinet type, trim style, and door material and style indicated. K. Accessories: 1. Mounting Bracket: Manufacturer's standard steel, designed to secure fire extinguisher to fire protection cabinet, of sizes required for types and capacities of fire extinguishers indicated, with plated or baked-enamel finish. 2. Identification: Lettering complying with authorities having jurisdiction for letter style, size, spacing, and location. Locate as directed by Architect. L. Finishes: a. Identify fire extinguisher in fire protection cabinet with the words "FIRE EXTINGUISHER." 1) Location: Applied to cabinet door. 2) Application Process: Silk-screened. 3) Lettering Color: White. 4) Orientation: Horizontal. 1. Manufacturer's standard gloss red integral color. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine walls and partitions for suitable framing depth and blocking where recessed and semirecessed cabinets will be installed. B. Proceed with installation only after unsatisfactory conditions have been corrected. AE Project #: <%Project Number%> Fire Extinguisher Cabinets 10 44 13-4

3.2 PREPARATION A. Prepare recesses for recessed fire protection cabinets as required by type and size of cabinet and trim style. 3.3 INSTALLATION A. General: Install fire protection cabinets in locations and at mounting heights indicated or, if not indicated, at heights indicated below: 1. Fire Protection Cabinets: 54 inches above finished floor to top of cabinet. B. Fire Protection Cabinets: Fasten cabinets to structure, square and plumb. 1. Unless otherwise indicated, provide recessed fire protection cabinets. If wall thickness is not adequate for recessed cabinets, provide semirecessed fire protection cabinets. 2. Fasten mounting brackets to inside surface of fire protection cabinets, square and plumb. 3.4 ADJUSTING AND CLEANING A. Remove temporary protective coverings and strippable films, if any, as fire protection cabinets are installed unless otherwise indicated in manufacturer's written installation instructions. B. Adjust fire protection cabinet doors to operate easily without binding. Verify that integral locking devices operate properly. C. On completion of fire protection cabinet installation, clean interior and exterior surfaces as recommended by manufacturer. D. Touch up marred finishes, or replace fire protection cabinets that cannot be restored to factory-finished appearance. Use only materials and procedures recommended or furnished by fire protection cabinet and mounting bracket manufacturers. E. Replace fire protection cabinets that have been damaged or have deteriorated beyond successful repair by finish touchup or similar minor repair procedures. END OF SECTION 10 44 13 AE Project #: <%Project Number%> Fire Extinguisher Cabinets 10 44 13-5