Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems

Similar documents
Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems

Air Conditioning Inspections for Buildings Condensers

Experiment 2: Test on Domestic Refrigerator for evaluation of EER.

Refrigeration Technology in Building Services Engineering

Applications of Thermodynamics: Heat Pumps and Refrigerators

Session: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island

BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City)

2016 Annual Conference

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

Executive Summary. Number of Low Number of High Number of Faults , Number of OK

Carnot. 2. (a) Discuss the advantages of the dense air refrigeration system over an open air refrigeration system?

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Pressure Enthalpy Charts

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

TEST REPORT #32. System Soft-Optimized Test of Refrigerant D2Y60 in Air Source Heat Pump

Chapter 11. Refrigeration Cycles. Study Guide in PowerPoint

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS UNIT OBJECTIVES

Thermodynamics I. Refrigeration and Heat Pump Cycles

c Dr. Md. Zahurul Haq (BUET) Refrigeration Cycles ME 6101 (2013) 2 / 25 T270 COP R = Q L

The impact of water treatment on refrigeration system energy efficiency

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

Refrigeration Cycles. Refrigerators, Air-conditioners & Heat Pumps. Refrigeration Capacity/Performance. Dr. Md. Zahurul Haq

Refrigeration and Air Conditioning

T270 COP R = Q L. c Dr. Md. Zahurul Haq (BUET) Refrigeration Cycles ME 6101 (2017) 2 / 23 T354

TEST REPORT #47. System Drop-in Test of R-32 and Refrigerant Blends ARM-71a, HPR2A, L-41-2 and DR-5A in a Five-Ton R-410A Rooftop Packaged Unit

THE FIVE W s SYSTEMES LMP MECHANICAL SUB-COOLING. I.G.A. GIRARD, TERREBONNE, Qc. INCREASED SYSTEM EFFICIENCY & LOWER ENERGY COSTS

ErP. ErP READY. The Eco-Design Directive ErP for refrigerator systems and heat pumps. READY

HVAC Fundamentals & Refrigeration Cycle

Suction Accumulators. Introduction. Suction Accumulators

(Refer Slide Time: 00:00:40 min)

Chapter 9. Refrigeration and Liquefaction

Daikin VRV Systems Plugin VE2012 User Guide

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

A Comparison Between Refrigerants Used In Air Conditioning

Daikin VRV Sizing & Simulation Plug-in User Guide

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Technical Information

Short Questions with Answers APPLIED THERMODYNAMICS(5 TH MECHANICAL) Chapter No-1

ISSN Vol.08,Issue.21, November-2016, Pages:

Thermodynamics II Chapter 5 Refrigeration

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

SERVICE ASSISTANT OVERVIEW FDSI Online Training

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

AHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency

A/C Cooling Load calculation and measurement

Split units, (single room unit and single condenser linked by pipework)

Water Jet Nozzle to reduce the operation cost in Air Conditioning unit

Chapter 10. Refrigeration and Heat Pump Systems

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

THE INSTITUTE OF REFRIGERATION

Low GWP Refrigerants for Air Conditioning Applications

Chapter 4 Compressors Overview & System Annual Power Consumption

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Figure 1: Schematic of internal heat exchanger vapor-injection cycle

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

CHAPTER 1 INTRODUCTION

TEST REPORT #53. System Drop-in Test of Refrigerant Blend DR-55 in a Five-Ton R-410A Rooftop Packaged Unit

COMMISSION REGULATION (EU) No /.. of

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

Brazed Plate Heat Exchanger for CO Applications

SIMULATION OF SWITCHING TRANSIENTS OF 90 TR CHILLER SYSTEM AT SASTRA UNIVERSITY

REFRIGERATION AND AIR CONDITIONING

Energy Performance of Low Charge NH3 Systems in Practice. Stefan S. Jensen

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

Why Hydrocarbons Save Energy

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

Tube-in-tube heat exchanger Type HE

LECTURE-17. Multi-Stage Vapour Compression Refrigeration. 1. Introduction

High efficiency air to water Heat pumps LZT series

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

Energy Efficiency Considerations in Refrigeration Systems

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

IP TRONIK. Project Scope: Simulation of car refrigerant circuit with the software GT SUITE and its comparison with real test bench measurements

R4H4. Product Specifications

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Variable refrigerant flow (VRF) systems

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Technical Bulletin (TB-0037)

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Chapter-8 Capacity Control of Refrigeration Systems

COMMERCIAL HVAC PACKAGED EQUIPMENT. Split Systems

0.4 In the preparation of this standard, assistance has been derived from the following standards:

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

EXPERIMENTAL VERIFICATION OF PERFORMANCE OF CAPILLARY TUBE USING VAPOUR COMPRESSION REFRIGERATION SYSTEM

SOLAR COOLING TECHNOLOGIES

The Refrigeration Cycle

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Technical Note. EHPA Quality Label Model Range Definition Version

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

2. CURRICULUM. Sl. No.

Tube-in-tube heat exchanger Type HE

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

R4H4. Product Specifications

Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power

Transcription:

. Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems PRESENTED BY NIRAJ MISTRY aircon@stroma.com

Cooling Load The Refrigeration Load Cooling load on refrigeration system determines: Plant size Power consumption This does not effect the COP. No refrigeration load = no COP or efficiency The smaller the load, the lower the power consumption.

COSP Efficiency of a Refrigeration Cycle The coefficient of system performance (COSP) is expressed as the capacity (kw) divided by the power input (kw) required to produce the cooling: COSP = capacity (kw) power (kw) This takes into account all fans, motors and controls associated with the system. The Seasonal Energy Efficiency Ratio (SEER) is now commonly used as it takes into account the seasonal performance.

COP Efficiency of a Refrigeration Cycle The coefficient of performance (COP c ) is expressed as the useful cooling duty (kw) divided by the power input (kw) required to produce the cooling: HeatOutput HeatingCoP(%) x100 PowerInput The maximum efficiency, Carnot cycle coefficient of performance, is based upon a theoretical thermodynamic cycle on which the actual cycle is based: COP c = T e /(T c -T e ) Where: T c is the condensing temperature (K) T e is the evaporating temperature (K) c denotes a cooling COP This does not take into account all fans, motors and controls associated with the system, compressor only.

Performance Efficiency of a Refrigeration Cycle An actual COP would be typically 50% less than the theoretical COP due to: Deviations from the theoretical cycle Inefficiencies within the practical cycle: Pressure losses Heat transfers Example: A COP of 3.7 means The refrigeration unit will produce 3.7kW of cooling per kw of electrical consumption by the compressor motor. Question: Why is the efficiency greater than 1? Surely this is against the laws of thermodynamics?

Performance Efficiency of a Refrigeration Cycle Answer: Cooling duty is in kw of heat exchange energy, whereas the power input is electrical or work energy. If: power input was expressed as heat energy (i.e. considering the energy used to produce the electricity), then the ratio would be less than 1 (or 100%). COP provides useful information about the running costs of the refrigeration system with respect to the cooling duty.

Performance Efficiency of a Refrigeration Cycle COP is most dependant on temperature difference (temperature lift) between the condensing and evaporating temperatures. Smaller the difference, greater the COP Bigger the difference, lower the COP 2-4% increase in performance for: 1K increase in evaporating temperature 1K decrease in condensing temperature COP is also affected by: Refrigerant type Equipment used Controls and maintenance

COP Factors Lowering the Condensing Temperature Use a condenser with a high basic rating (usually a larger condenser). Allow the condensing temperature to float down with the ambient temperature. Average UK temp is ~10 C, should be used to advantage, as opposed to holding a condensing temperature artificially high. Can save in excess of 25% energy. Use water instead of air as condenser medium. Ensure condensers do not become blocked, or flow of cooling air or water becomes impeded in any other way.

COP Factors Raising the Evaporating Temperature An evaporator with a higher basic rating is used (usually a larger evaporator). The evaporator is defrosted if necessary. Ensure the evaporator is clean and free of blockage.

COP Factors Compressor Efficiency Varies with type and manufacturer. Most efficient compressor for an application should be selected. Depends on: Size of cooling load. Refrigerant used. Temperature of application. Average temperature of the cooling medium (air/water)

COP Factors Amount of Refrigerant This has a significant effect on the temperature lift. Too much or too little reduces efficiency. Systems that leak refrigerant consume more power than necessary. Costs UK refrigerant plant owners and extra 11%. Over charged systems have more refrigerant to lose in the event of a leak environmentally detrimental.

COP Factors Refrigerant Type Variation of this can effect COP up to 10%. Hardware needs to be optimised to the refrigerant for benefit. The most efficient refrigerant for an application depends upon: Compressor type Temperature of the application Average temperature of the cooling medium (air/water).

COP Factors Superheat of the Suction Vapour This needs to be as low as possible. Warmer vapour reduces the capacity of the compressor; Does not reduce its power input. On direct expansion systems achieved by: Correctly controlling the expansion device; Insulating the suction line.

COP Factors Amount of Subcooling This should be as high as possible. Increases the capacity of the system. Does not increase its power input. Liquid line should not: Be insulated. Pass through any hot areas (kitchens, direct sunlight).

Comparison Cooling method Usage in building services Efficiency Capital cost Carbon footprint Vapour compression High High Low Medium Absorption: Generated heat Low Low High High Waste/free energy Low High High Low Air cycle Low Low High Medium Evaporative Medium High Low Low Dessicant Medium High Low Low Carbon dioxide Low Medium High Low

NDHCVCG Non-Domestic Heating, Cooling and Ventilation Compliance Guide (Second Tier Ref: ADL2B) For Cooling Energy Efficiency Ratio (EER) For Chillers; EER is defined as the ratio of cooling energy delivered, divided by the energy input to the cooling plant. For Packaged Air Conditioners; EER is defined as the ratio of energy removed from air within conditioned space, divided by the effective energy input to the unit

Cooling Seasonal Energy Efficiency Ratio (SEER)

Cooling

Cooling Cooling Controls

Cooling Determining The SEER - no part load data

Cooling Determining The SEER by part load data

Ventilation Air Distribution Systems Specific Fan Power (SFP) Relates to the total power (circuit-watts) used by the fan or air handling plant per unit of design flow rate provided. (Units -Watts/litre/second) Limiting values of specific fan power are set out dependant upon system type Limits for existing buildings required for Part L2B Compliance

Ventilation

Pipework

Ductwork

Reference Material Heating, Ventilation, Air Conditioning and Refrigeration, CIBSE Guide B, Chartered Institute of Building Services Engineers, 2005 CIBSE KS13: Refrigeration, CIBSE Knowledge Series, Chartered Institute of Building Services Engineers, 2008 ASHRAE Handbook: Fundamentals, American Society of Heating, Refrigeration and Air Conditioning Engineers, 2001 BS EN 378: Specification for Refrigeration Systems and Heat Pumps; Part 1: 2000: Basic Requirements, Definitions, Classification and Selection Criteria; Part 2: 2000: Design, Construction, Testing, Marking, and Documentation; Part 3: 2000: Installation Site and Personal Protection; Part 4: 2000: Operation, Maintenance, Repair and Recovery, London: British Standard Institution, 2000 Non-Domestic Heating, Cooling, and Ventilation Compliance Guide, Department For communities and local Government Building Regulations Approved Document L2B, Department For communities and local Government