INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE

Similar documents
PG 990 Atomic Absorption

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

LABTRON LAAS - Series Atomic Absorption Spectrophotometer

ATOMIC ABSORPTION SPECTROMETER AAS 3500 EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

File No. 28(1192)/2017/Pur Date: 19/06/2018

Affordable Lab Technology

SP-3800AA Atomic Absorption Spectrophotometer

Atomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

AAnalyst 700 Atomic Absorption Spectrometer

TENDER NOTICE NO. 07/2012 INVITATION FOR BIDS / NIT

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

Atomic Absorption Spectrometer

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems

A Platform for the Future ULTIMA 2 ICP OPTICAL E MISSION S PECTROMETER

ice 3000 Series Atomic Absorption Spectrometers

Pressed pellets. Liquids, Slurries. Loose powders, Rocks, Granules. Metal cuts, Solids. Fused beads. Small parts. Coatings, Foils

AAnalyst 600/800 atomic absorption spectrometers

Variable Temperature Options for Optical Experiments

Table-1: Clarifications and modification in tender specifications based on Pre-bid meeting discussion

Mercury Vapor Monitor VM-3000

VM-3000 Mercury Vapor Monitor

Technical specifications of FT-IR Spectrometer

NanoReady. Micro UV-Vis Spectrophotometer

C122-E058C. AA-7000 Series. Shimadzu Atomic Absorption Spectrophotometers

Selecting the right generator for your GC system. By Ed Connor, GC Product Specialist, Peak Scientific Instruments Ltd

NOTICE INVITING TENDERS FOR THE PURCHASE OF 1. FLASH CHROMATOGRAPHY 2. ION CHROMATOGRAPH 3. MICROWAVE MUFFLE FURNACE

t. +44 (0) f. +44 (0) e. w.

Tubing spares and piping accessories. Gas purification and control 1 Moisture Traps,Carbon traps 2 Gas Purification Panels 3 Gas Control Box

FIXED GAS ANALYZER (FGA)

Technical manual 2G-TA 04 - Gas

Atomic Absorption Spectrophotometers. AA Series C122-E058E

TIMS TIMS. Thermal Ionisation Mass Spectrometry.

SIEMENS ULTRAMAT 6 IR CARBON MONOXIDE ANALYZER METHOD VALIDATION FOR TESTING CARBON MONOXIDE IN NITROGEN, NF

150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER

FPD - Flame Photometric Detector

Updated Leak Detection & Location Technology

CALIDUS tm the Modular micro Gas Chromatograph

CS744 Series: Carbon/Sulfur by Combustion

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

VM-3000 Mercury Vapor Monitor

Advanced XRF Technology for Precision Plating Measurement

portable gas analyser

Chemtron Science Laboratories Pvt. Ltd.

Giving You the Design Tools to Communicate, Excite & Win Customers. Industry-Leading Landscape Design Software. Version 24

Ref. No. RRSS/CH-18/ RIDF Dated : ii) Submission of e-tender: the tender shall be submitted on line within upto 6.00 pm.

Thermo Scientific Rocket Evaporator. Revolutionary solvent evaporation complete laboratory workflow

Series 9000 Total Hydrocarbon Analyzer

Title. Author(s)Yoshida, Fumikazu; Yoshida, Haruyo. Issue Date Doc URL. Type. File Information

Soil and Plant Methods List for Automated Ion Analyzers. Flow Injection Analysis

Supply & Installation of Fire Protection System at STPI- Nashik. Tender No. STPI/P/PUR/07/14-15 Date Signature of Bidder

Specifications Wavelength Range: 190 nm to 800 nm continuous

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

POPULAR CONFIGURATION GCs Cryosulfur GC. System Overview

Variable Temperature Microprobe Systems

White paper on the Dielectric Barrier Discharge Detectors. Introduction:

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

Patriot Systems Limited

CombustionONE. Improving and Sustaining the Combustion Asset. Driven by the New Standards. Bulletin 53A90A01-01E-A

THERMAX Efficiency Monitor

Customers should provide all necessary operating supplies upon request of the engineer.

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

GC DETECTORS Reduction Gas Detector - RGD. Overview

High Volume Injection up to 5 ml with the Agilent 1200 Infinity Series Online SPE Solution for Highest Sensitivity

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

The last date of submission of responses has been extended up to 14: 00 hrs on 20/07/2018.

USER MANUAL MINITRACER PORTABLE SNIFFER

Agilent 1290 Infinity II Vialsampler Data Sheet

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

M&S Series Atomic Absorption Systems

Labtronics.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

AppNote 6/2008. Automated SPE and Fast GC-ECD Analysis of PCBs in Waste Oil KEYWORDS ABSTRACT INTRODUCTION. MACH, Fast GC-ECD, SPE, PCB, waste oil

ISO INTERNATIONAL STANDARD. Essential oils Analysis by gas chromatography on chiral capillary columns General method


Optimizing the Performance of the Agilent 1290 Infinity Evaporative Light Scattering Detector

COMPLETELY AUTOMATED HYDROLYSIS

ARES-G2 Rheometer. Site Preparation Guide. Revision A Issued June 2016 Page 1

Using the Model 1500 Portable Chilled Mirror Hygrometer

ORTEC DSPEC LF. High-Performance Digital Signal Processor for Gamma Spectroscopy. ... in a compact package at an economical price.

Wide Band Flame Detector KLC 20 for all kind of oil flames with intermittent burnerr operations

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

Gas Detection - GD -

BIDDER S OFFICE FACILITIES

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

SCION 436-GC. Dimensions and Weights

Introduction to the Fusion TOC Analyzer

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

INTERNATIONAL STANDARD

ZLA Series Double-stages Vacuum Transformer Oil Purifier Transformer Oil Purification

Alarm System. Enjoy the Security. Enjoy Simple Life KERUI Doorbell. Security and Protection. Leading Brand of Intelligent. Present by Secrui Group

North American Technical Services

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

Model OEM-2 INSTRUCTIONS FOR USE

Transcription:

INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE CLARIFICATION ON TENDER NUMBER - IISER-PUR-0284-17 ITEM DESCRIPTION- PROCUREMENT OF GRAPHITE-FURNACE ATOMIC ABSORPTION SPECTROMETER WITH CHNS/O ANALYZER Refer our Press Tender Notice No.IISER/S&P/10/17 dated 6/6/2017 for procurement of Graphite- Furnace Atomic Absorption Spectrometer With CHNS/O Anaylzer. Tender Reference Number IISER- PUR-0284-17. Pre-Bid meeting was held on June 13 th, 2017 at 2.30 PM and minutes of meeting is as under. At the outset, the Chairman welcomed all the Members and the representative of the Prospective Bidders and briefed in general the scope of the Project and thereafter requested Assistant Registrar (S&P) to brief the vendors on the salient features of the commercial terms and the indenting Officer to read out the clarification sought by the Prospective Bidders and replied thereto as detailed in Annexure -II The representatives present were satisfied with the replies given and it was informed that the corrections / additons / clarifications given, as discussed during the Pre-Bid Conference would be hosted on the website of IISER Pune and all the Prospective Bidders are required to take cognizance of the proceedings of the Pre-Bid Conference before submitting their bids as stipulated in the Bidding Documents. The other terms & conditions of the notice issued on our IISER website www.iiserpune.ac.in will remain unchanged. No more correspondence in this regard will be entertained The meeting ended with vote of thanks to the Chair Sd/- 13.6.2017 Assistant Registrar (S&P)

ANNEXURE -II IISER PUNE PRE-BID CONFERENCE FOR GRAPHITE-FURNACE ATOMIC ABSORPTION SPECTROMETER WITH CHNS/O ANALYZER TECHNICAL QUERIES AND CLARIFICATION TENDER NUMBER - IISER-PUR-0284-17 DATE : 13.6.17 S.No Query/Clarification Sought Clarification / Amendment 1 In the documents it is mentioned as Graphite-Furnace Atomic Absorption spectrometer with CHNS/O analyzer: We are manufacturers of only CHNS/O analyzer (one unit installed in IISER Pune) and do not have Atomic Absorption Spectrometer to offer. Can we quote the CHNS/O analyzer only? As there are hardly any manufacturers who can offer both instruments, on the other had if asked for individual instruments there are many manufacturers offering proven instruments in India. 2 Elemental Separation technique based on selective retention of the gases to have a steady-state,stepwise signal for accurate determination of gases : We We need a system that can analyze concentration of most of the elements in geological samples. The Atomic Absorption Spectrometer can measure many of the elements. The AAS may not measure abundance of few key elements (e.g. C, H, N, S, O), and hence, we also require a CHNS analyzer. We, therefore, require the Atomic Absorption Spectrometer with CHNS analyzer to meet our requirement and hence, no change in the specification is made in this regard. No clarification required.

have most advanced and proven temperature program desorption TPD technique which is gives well defined peaks for each of the elements without any overlap even if the relative concentration of individual elements is very high as compared to each other. 3 Sample size Mentioned is 0-500mg : We request you to also ask the bidders to show the demonstration of the analysis of the same on their respective instruments. 4 The analytical ranges of the elements are not mentioned as how much mg of each elements are intended to be analysed. 5 Suitable software for analyzing the data and running the instrument: Whether the instrument should be fully controlled through software for viz. setting temperature, flows, analysis start and analysis stop, etc. 6 Request you to change alignment specification to automatic vertical alignment only. This suggestion has now been included in the revised specification. The chemical compositions of geological samples vary widely and hence, no ranges are mentioned. We require suitable software for data analyses and running the instrument. Any additional feature in the software will be beneficial. We require automatic alignment both in vertical and horizontal direction. Therefore, no change is made in the specification in this regard. 7 Autosampler: Request you to consider capacity for same to be 60 or more. As suggested, we have now changed the minimum auto-sampler position to be 60. 8 Request you to consider Self Reversal along with Zeeman. This suggestion has now been included in the revised specification. 9 Request you to consider button push/ manual initial ignition. We require automatic ignition of the instrument through software. Therefore, no change is made in the specification in this regard. 10 Sensitivity: We describe our AAS stability as RSD of <1% with 2ppm Cu solution at 0.3Abs. Kindly consider the same. The suggested sensitivity for absorbance at 2 ppm has now been incorporated in the revised specification. We require a RSD of <0.5%, and hence, the RSD is not changed. 11 Revised Specifications Revised Specifications are appended below

Revised Technical Specifications of Graphite-Furnace Atomic Absorption spectrometer with CHNS/O analyzer The Earth and Climate Science program at IISER, Pune aims to procure a system for chemical analyses of geological samples. This system should have Atomic absorption spectrometer and CHNS analyzer with the following minimum specifications: 1. Graphite-Furnace Atomic Absorption Spectrometer Fully Automated Personal Computer controlled Integrated (graphite-furnace and flame) Atomic Absorption Spectrometer System with Double Beam optics. Atomizer System A space-saving compact integrated dual atomizer system with inbuilt flame and furnace atomizers. An instant changeover from Flame to Furnace mode and vice-versa should be automatic through the software. The vertical and horizontal alignment of the flame burner head in the light beam should be totally automatic through the software. The Graphite Furnace Atomizer must be permanently aligned with no movement, alignment and optimization required. The Furnace autosampler must be integrated to main Spectrometer with a minimum of 60 sample positions. Built-in camera in the graphite furnace to display actual sample introduction and method optimization. Accessory to provide high definition video images from inside the furnace graphite cuvette. The Graphite Furnace system should be equipped with pyrolytically/equivalent coated graphite tube (20 nos. each) and maximum attainable temperature should be 3000 C. An imported air compressor (oil free, noiseless air compressor with air purifiers and moisture trap) and an imported recirculating water chiller unit of appropriate capacity for cooling of Graphite Furnace must be quoted by the vendor. Stainless steel exhaust hood along with fan and fitting hardware required for supplied AAS unit. Optics A true double beam spectrometer system with high light throughput. Minimum Wavelength range: 190 900 nm Variable slit width between 0.2 to 1.0 nm with automatic slit selection. Detector: Photomultiplier Tubes (PMT) or Solid State Detector Lamps: The system should have a minimum 6 lamp holder with a provision for automatic aligning turret with computer controlled lamp selection for both flame and furnace. Single element Coded Hallow Cathode Lamps for Na, K, Ca, Mg, Al, Fe, Mn, V, Ti, Ba, Sr, Rb, Cu, Cr, Ni, Co, Mo, Cd, Pb, Zn; and special lamps that are used for the analysis of volatile elements like As, Hg, Se. should be supplied with the instrument. Standards: NIST traceable standards for each element separately 100 ml (1000 ppm) each for Na, K, Ca, Mg, Al, Fe, Mn, V, Ti, Ba, Sr, Rb, Cu, Cr, Ni, Co, Mo, Cd, Pb, Zn, As, Hg, Se should be quoted. Sample Introduction System A high sensitivity nebulizer system including impact bead and flow spoiler with corrosion resistant against the acids like 5% hydrofluoric acid, hydrochloric acid and Nitric Acid. Corrosion resistant spray chamber.

Background Correction Methodology Deutrium and Zeeman background/self-reversal background correction/equivalent. Deutrium (D2) lamp should be included as standard in the offer. Gas Flows system Software controlled flame ignition and automatic changeover of oxidant flow from acetylene to nitrous oxide when switching to or from air-acetylene to nitrous oxide - acetylene flame. Fully software controlled oxidant and fuel gas flow monitoring. All safety interlocks built-in and additional feature like Burner Head Interlock, Nebulizer/End Cap Interlock, and Drain Interlock to be built-in. Vendor should quote appropriate ultra purity grade acetylene cylinder, nitrous oxide gas cylinder with dual stage regulators with stainless steel diaphragm and purification panel. UPS Suitable, branded UPS of 10 kva should be included for minimum 1 hour back-up to run the AAS instrument during failure of power supply. Sensitivity: Greater than 0.7 absorbance with the precision of <0.5% RSD from 5 second integrations for 5 ppm Cu standard, or equivalent sensitivity (i.e. 0.3 absorbance with <0.5 % RSD from 5 second integrations for 2 ppm Cu standard). System should be quoted with Vapor/hydride analysis for flame and furnace to gain an extra mileage of accessing ppb and ppt levels respectively. Desktop Computer for AAS Branded state of the art desktop Personal Computer having minimum configuration: 1 TB HDD, Latest Processor, 4 GB RAM, TFT-LED 21 Monitor, DVD writer, Optical Mouse, 10 usb port, Keyboard, Serial Port-2, Suitable Licensed Windows 7 or higher O/S loaded 2. Branded 23" LED colour monitor for an easy viewing 3. Branded USB Keyboard, mouse and b/w printer. Suitable software for analyzing the data and running the instrument Vendor should include 3 years of extended warranty. 2. CHNS analyzer Elemental Separation technique based on selective retention of the gases to have a steady-state, stepwise signal for accurate determination of gases. Samples Sample size: 0-500 mg Sample Type: solid and liquid samples Micro analytical balance for weighing the sample with at least 1 µg readability. Vibration free table of suitable size for keeping analytical balance CHNS kits for 2000 sample analyses in solid and liquid matrices should be quoted. Furnace Two Furnaces for CHNS/O and CHNS/CHNS analyses There should be facility in the instrument to shift from one furnace to another furnace automatically through software without manual intervention.

Furnace temperature: 1100 C (during the combustion the furnace temperature can reach >1600 C) Pyrolysis (Oxygen determination) furnace temperature > 1000 C Autosampler Solid Sample introduction with > 60 Samples Liquid sampling device as applicable for natural water sample analyses. Liquid Sample Introduction (syringe-10, 50, 100 µl). Detector Thermal conductivity detection (TCD) or any other suitable detection methods. Detector suitable for S analysis < 50 ppm to be included in the offer. Gas requirements and accessories Carrier gas: Mainly helium with ultra high purity Combustion gas: oxygen with ultra high purity Ultra high pure helium, ultra high pure oxygen and ultra-high pure nitrogen cylinders with necessary tubing, connectors and gas regulators must be offered in the main system Desktop Computer for CHNS Branded state of the art desktop Personal Computer having minimum configuration: 1 TB HDD, Latest Processor, 4 GB RAM, TFT-LED 21 Monitor, DVD writer, Optical Mouse, 10 usb port, Keyboard, Serial Port-2, Suitable Licensed Windows 7 or higher O/S loaded 2. Branded 23" LED colour monitor for an easy viewing 3. Branded USB Keyboard, mouse and b/w printer Suitable software for analyzing the data and running the instrument Warranty Minimum warranty of 10 years for both the furnaces and Thermal conductivity detector (TCD) should be quoted. Minimum warranty of 3 years for the instrument should be quoted. UPS Suitable, branded UPS of 10 kva should be included for minimum 1 hour back-up to run the CHNS instrument during failure of power supply. The bidder has to successfully demonstrate all the technical specifications of the quoted instrument to qualify for commercial bidding.

ANNEXURE -III IISER PUNE PRE-BID CONFERENCE FOR GRAPHITE-FURNACE ATOMIC ABSORPTION SPECTROMETER WITH CHNS/O ANALYZER COMMERCIAL QUERIES AND CLARIFICATION TENDER NUMBER - IISER-PUR-0284-17 DATE : 13.6.17 S.No Query/Clarification Sought Clarification / Amendment 1 The EMD asked is combined for both the instruments if we are allowed to quote for CHNS/O analyzer what will be the value tender fees and EMD we are supposed to submit. The AAS instrument with CHNS analyzer needs to be quoted together.