Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

Similar documents
Installation Guide. Ceiling PIR Detector (311) Features and Connections

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

LPCMPIRM65 & LPCMPIRDSI65

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

EBDSPIR-PRM-LV Product Guide

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

µdim Microwave Sensors User Manual

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

Ceiling Microwave presence/absence detector 12-24V AC/DC

MPAD-C 12-24V. Ceiling microwave presence/absence detector 12-24V AC/DC. Product Guide. Overview. Features

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

FR-A180 FR-A360. Occupancy detector. Use

LPC3BSP65 & LPC3BDP65

MWS3 Ceiling Mount Microwave Occupancy Detector

SCS motion sensors Surface/wall mounting - PIR

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

MWS3A-PRM Product Guide

, ,

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

SWITCHLITE MRE DDM ADJ

EBMHS (standard & slim-line PSU)

Integrated PIR detectors

SWITCHLITE MRE SLDM ADJ

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

Direct Dim Microwave Presence/Absence Detector

Passive infrared ceiling sensor

5 Litex Elite. Industrial. Up to 170Llm/cW. Mains lighting IK10

D-Tect 2 GJD300 Quad PIR Movement Detector

Analogue Dimming Microwave Presence/Absence Detector

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

D-TECT Dual Tech. GJD360 Triple Technology External Detector

Movement Detector GJD 300

Description. Optex Incorporated

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

Technical Application Guide

Occupancy Sensor Operation with Lighting Fixtures

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

Detector switch - Dual Tech SCS

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

DI601AM Outdoor PIR/AM Detector Installation Sheet

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

SENSA MRE DDM MR

D-TECT 3 IP. GJD260 IP Motion Detector

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

UP 258E11 OPTISENS OFFICE

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

Eco-sensors - PIR. Catalogue number(s): / / Use. 1. Use Technical characteristics (continued)

Conventional Audible Visual Range

EasyAir SNH200. Sensors. Datasheet. EasyAir SNH200

Dräger Polytron Pulsar 2 Open Path Gas Detector

Instructions PRODUCT RANGE NEWLEC DALI OCCUPANCY DETECTOR PART NUMBER NL5701DALI

D-TECT 2 IP. GJD230 IP Motion Detector

B.E.G. LUXOMAT. Find the right detector.

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

Detailed operating instructions

FIRERAY 5000 range USER GUIDE

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Extended Range DUAL TEC Motion Sensor

Product DELTA i-system DELTA profil titanium white 5WG HB11 pearl grey 5WG AB01 Motion detector

Detector switch - Dual Tech

English. Italiano. Português. Françias. Español

2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.

Detailed operating instructions

Energy efficient lighting control

DT900 Series Sensors TECHNOLOGY FOR LARGE COMMERCIAL AND INDUSTRIAL APPLICATIONS. Impressive Performance, Impressive Coverage

Sensors and Detectors

Duct Air Quality Sensors

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

Motion detector UP 255, UP 256, UP 257, UP 258 5WG AB 5WG AB 5WG HB

Detector Application Notes

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

1125 PIR Motion Detector

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

PROFIBUS-PA Display RID 261 PROFIBUS-PA

Products. World Edition

Standalone Presence Detectors

Transcription:

Installation Guide High-Bay PIR Presence/Absence Detector (317) The 317 High-Bay PIR Presence/Absence Detector, in conjunction with a Helvar lighting control system, provides automatic control of lighting loads in buildings and interior spaces with high ceilings. The 317 is typically installed in warehouses and factories, and is used in other applications where mounting heights are too high for standard sensors. The 317 is compatible with Helvar s lighting systems and configuration software, Designer and Toolbox. Once connected to a Helvar DALI network and lighting control system, the software automatically detects the unit, which can then be programmed with the required functions. Features and Connections Mounting bezel Retaining spring Sensor lens - PIR Sensor - Status LED - IR Receiver DALI + DALI - Retaining spring PIR Sensor Detects movement within the detection range, allowing load control in response to changes in room occupancy. Status LED The red LED flashes to indicate: Valid setting received (single flash of LED) Identify active (LED flashes repeatedly) DALI Connection The DALI connection is made via DA+ and DA terminals. The device is not polarity-sensitive. Sensitivity, Time-Outs, Identify Adjust the sensitivity using Designer or Toolbox. The factory default setting is 9 (maximum). Note: On maximum sensitivity, the detector unit is extremely sensitive to movement and may detect through glass, thin walls or partitions. If this causes a problem, reduce its sensitivity. The temperature difference between the detection target and the background must be at least 4 C. Adjusting On, Exit and Transition Time-Outs The default time-outs for On, Exit and Transition can be altered using Designer, or Toolbox. To make sure that the sensor is correctly connected to the DALI network, use the Identify function in Designer or Toolbox. The sensor s status LED flashes repeatedly until Identify is cancelled. 1 Helvar Data is subject to change without notice. www.helvar.com

Detection Area and Detection Area Masking Detection area Alignment Marks A lower mounting height will decrease the overall size of the detection zone. The sensor head has four alignment marks. Alignment marks 40 m 15 m These marks correspond to the four outer passive infrared sensors located under the lens. Use these marks to align with aisles and corridors to ensure the best detection characteristics. Detection Area Masking Two adaptable clip-on shielding masks are supplied with the 317. Each can cover half of the sensor lens. Lateral or radial strips can be cut out of the masks to customise the detection area. Aisles/Corridors (lateral masks) Cut the mask to make two lateral masks. This leaves a straight section of the lens uncovered. The slots you cut out approximate to the levels of sensor coverage given in the following table. Slot Masking shield: number approx. % coverage 1 45 % 2 30 % 3 20 % 4 10 % Slots: 1 2 3 4 4 3 2 1 Alignment mark Small Areas (Radial Masks) Cut semicircles out of the mask to make two radial masks. This leaves a circular section of the lens uncovered. The diameter numbers of the semicircles you cut out approximate to the levels of sensor coverage given in the table. Diameter Masking shield: number approx. % coverage 1 90 % 2 65 % 3 45 % 4 35 % 5 20 % 1 2 3 4 5 5 4 3 2 1 Diameter number Helvar 317 High-Bay PIR Presence/Absence Detector: Installation Guide 2

Orientation and Sensitivity When someone walks across the detection area (not directly towards the centre of the sensor), the sensor range is greater than when someone walks towards the centre of the sensor. Therefore, in applications where occupants are free to move in all directions, such as sports halls, the walk-across detection range can be used when planning sensor positions. In applications where the occupants direction of movement is restricted, such as aisles and corridors in warehouses, the walk-towards detection range can be used when planning sensor positions. To ensure the best detection characteristics, use the alignment marks on the sensor head (see Alignment Marks ) to align with aisles and corridors. Due to the nature of PIR technology, it is not possible to guarantee the range diameter at any mounting height. The performance of the sensor can be altered by site-specific conditions that affect the sensor s ability to detect movement; for example, the occupants clothing, the use of machinery or an uneven air temperature distribution within the space. It can also be altered by the detection target s speed of movement. The faster the target moves, the less accurate the detection becomes, so that fast moving vehicles, for example, can go undetected. Walk Across Walk Towards Alignment marks Height Range Diameter 15 m 40 m 10 m 26 m 6 m 16 m 3 m 9 m Alignment marks Height Range Diameter 15 m 30 m 10 m 20 m 6 m 12 m 3 m 8 m Installation The 317 and 317M can be mounted into a ceiling void or onto a solid surface using an appropriate back box. Both versions of the detector can be used with Helvar s SBB-A back box for surface-mount, IP40 installation or with Helvar s SBB-P for surface-mount, IP65 installation. The following steps are required for all versions and installation of the unit. 1. Connect the DALI connector to the socket located at the rear of the sensor. 2. Flush fixing: Insert the unit into the ceiling or wall (see Connection and Fixing: Flush Fixing ); or Surface mounting: Install the unit using the SBB-A or the SBB-P surface back boxes, as appropriate (see Connection and Fixing: Surface Mounting ). 3. Power the unit up. 4. Configure the unit using Designer or Toolbox. If the load triggered by the sensor comes on, by default it will take 20 minutes (of no movement detected) for the load to switch off. Installation Notes Position the sensor so that the occupants of the room are normally inside the detection zone. Do not fix the sensor to an unstable or vibrating surface. Do not install the sensor within 1 m of any lighting, forced air heating, or ventilation equipment. Consider the possible effects on infrared detector of layers of hot and cold air in large buildings. Note: Layers of cold or hot air can form in the upper part of large buildings, such as warehouses, due to a number of factors, including the layout of the building, heating and ventilation systems, shelving system arrangements, roofing materials and the weather. If the sensor is positioned in or above such a layer of air, the sensitivity of the sensor cannot be guaranteed. For information on how to insert the unit into a ceiling or wall, see Connection and Fixing: Flush Fixing ; for information on how to insert the unit into a surface back box, see Connection and Fixing: Surface Mounting. 3 Helvar Data is subject to change without notice. www.helvar.com

Connection and Fixing: Flush Fixing Ø 64 mm 68 mm 1. 2. 3. Fit silicone gasket if required. Protective cover WARNING Take special care when bending springs to install the unit. Connection and Fixing: Surface Mounting There are two different mounting procedures: one for the 317 onto the SBB-A surface back box, another one for the 317M onto the SBB-P surface back box. Both back boxes must be ordered separately. Mounting onto Surface Back Box SBB-A (IP 40) 1. 2. 3. 4. 1 2 SBB-A surface back box Helvar 317 High-Bay PIR Presence/Absence Detector: Installation Guide 4

Mounting onto Surface Back Box SBB-P (IP65) 1. 2. 3. 4. 1 2 5. 6. 7. 8. 9. 5 Helvar Data is subject to change without notice. www.helvar.com

Technical Data Connections DALI: Cable rating: Power DALI supply input: DALI consumption: Sensors Presence detector: Infrared receiver: Range: Mechanical data Mounting hole diameter: Bezel diameter: Recommended clearance depth (incl. 50 mm for cabling): Material (casing): Removable connector block Wire size: 0.5 mm² 1.5 mm² solid, flexible or stranded All cables must be mains rated. 13 V to 22.5 V 20 ma PIR: Passive infrared presence detector For remote control commands. Note: Adjust sensitivity using Designer, or Toolbox (not by remote control unit). 5 m 15 m 68 mm 88 mm 80 mm (without protective cover); 100 mm (with protective cover) Flame retardant ABS and PC/ ABS Finish / Colour: Matt / White RAL 9003 Weight: 120 g Conformity and standards EMC emission: EN 61000 6 1 EMC immunity: EN 61000 6 3 Safety: EN 60730 1 Environment: Complies with WEEE and RoHS directives. Sensor Head Gasket Ø 88 49 63 Ø 58 1.5 Protective cover 58 68 IP code: 317: IP40 & IP65* 317M: IP40 & IP65* * When the unit is mounted onto Helvar s SBB-P back box using the supplied gasket. Gasket: Silicone ingress protection gasket (not compatible with surface mount box SBB-A) Masks: Two adaptable masks included, each covering half of the sensor lens. Operating conditions Ambient temperature: 317: 0 C to +35 C 317M: 30 C to +35 C Note: The temperature difference between the detection target and the background must be at least 4 C. Relative humidity: Max. 90 %, noncondensing Storage temperature: 317: 10 C to +70 C 317M: 30 C to +70 C Ø 87 5 Helvar Ltd Hawley Mill Hawley Road Dartford Kent DA2 7SY United Kingdom www.helvar.com Helvar 317 High-Bay PIR Presence/Absence Detector: Installation Guide Doc. 7860287, issue 6, 2016-09-26 6