DUKE UNIVERSITY CONSTRUCTION STANDARDS

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

University of Rochester October 17, 2008 Brooks Landing Business Center

Union County Vocational - Technical Schools Scotch Plains, New Jersey

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

1. Division 22 Section "Emergency Plumbing Fixtures." 2. Division 22 Section "Drinking Fountains and Water Coolers."

2). Crane Co. 4). Kohler Co. 5). Universal-Rundle Corp. Revised September 29, 2017 Commercial Plumbing Fixtures

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

A. General: comply with appropriate standards. 1. International Association of Plumbing and Mechanical Officials: IAPMO. 2. California State AB 1953.

SECTION PLUMBING FIXTURES AND TRIM. A. Types of plumbing fixtures required for the project include the following:

LAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

GENERAL PLUMBING REQUIREMENTS

SECTION PLUMBING FIXTURES

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

HWC NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

DESIGN AND CONSTRUCTION STANDARDS July 2011

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Plumbing Standards

SECTION DOMESTIC WATER PIPING SYSTEMS. 0. Pipe and pipe fittings are specified in the following sections:

SECTION PLUMBING

PLUMBING FIXTURES, TRIM, AND SUPPORTS

GENERAL PLUMBING REQUIREMENTS

A. This Section includes the following domestic water piping specialties:

DOMESTIC WATER PACKAGED BOOSTER PUMPS

PARTS STOCKED REPLACEMENT FAUCET BIBB SCREWS... SCREW ASSORTMENT MISC. 3 /8" BIBB LOC SCREW 1 /2" BIBB SCREW 1 /2" BIBB LOC SCREW 3 /8" BIBB SCREW

PLUMBING FIXTURES CHAPTER 27

BRADLEY CORPORATION WASH FOUNTAINS Page 1 of 8

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

PLUMBING FIXTURES Reserved

GENERAL PLUMBING REQUIREMENTS

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

PLUMBING DESIGN GUIDELINES SECTION DESIGN GUIDELINES DUVAL COUNTY PUBLIC SCHOOLS

Mechanical Inspection Plumbing

A. This Section includes the following emergency plumbing fixtures:

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

DIVISION 10 SPECIALTIES

SECTION DOMESTIC WATER PIPING SPECIALTIES

SECTION PLUMBING SPECIALTIES

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

Lasco # Description Picture Lasco # Description Picture

BuildingName The Description of the Project P DOCUMENTS

D & L A.D.A. SOLUTIONS 448 WEST MAIN ST. AUBURN,WA (800) HOUR FAX (206) FROM THE PARTS PEOPLE. SUPPLY and MFG.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

Willoughby Industries - Security Products

GARCIA GALUSKA DESOUSA Consulting Engineers

LC500. Patient Care Unit, 29", Fixed Water Closet. Specifi cations Standard Equipment

2. All necessary storm and sanitary pumps shall be tied into emergency power, and sump levels shall be monitored electronically through the B.A.S.

Selection Guide.

TEMPOMIX COMFORT WATER SAVINGS VANDAL-RESISTANT SAFETY. Time flow basin mixer

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER

Work Order Number PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

PRICE BOOK CONTENTS 010 PIPE

University of New Hampshire Scholars' Repository

Moen Commercial Products Eco-Performance Product Guide

CHILD DEVELOPMENT & LITERACY CENTER H17-N104-CB SGA 17002

Yale University Design Standards

DeCA DESIGN CRITERIA HANDBOOK PLUMBING SYSTEMS

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

BRADLEY CORPORATION DOMESTIC WATER PIPING SPECIALTIES Page 1 of 9

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Wholesalers List Price Book. Effective Date: February 1, Fixtures WEP. Manual Products WLP HEALTHMINDER. Products HM. Genuine MicroPlumb

CLINICAL SERVICES ADMINISTRATION (214)

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

500H TOILET VESSEL LAVATORY FREESTANDING TUB

Helping create a better healthcare experience.

Fixtures Installation

MATERIALS Traps TRAPS. No. IPC IRC Description

Planning, Development & Facilities 349 Magnolia Avenue Glendale, California Tel: Fax: TRANSMITTAL

ASI Guide Specification

Wall Hung Closet Series. Floor Mount Closets Series 1 & 3 4 & 5. Vitreous. Fixtures. Repair Parts and Maintenance Guide ST-2000 WALL HUNG SERIES

Instructions. Certifications Brass w/built-in Stop Valve. Pressure Balance Shower Valve. Tools Required. Important Points.

This chapter investigates domestic

WAW-2311 WAW-2322 WAW SERIES LAVATORIES

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD

This Product MasterSpec Section is licensed by AVITRU, LLC to Haws Corporation ("Licensee").

Model Z Sundara Reef Triple Basin Hand Washing System

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

Plumbing and Drainage

WATTS WALL-MOUNT WIDESPREAD BATHROOM FAUCET INSTALLATION

TABLE OF CONTENTS DIVISION 22 - MECHANICAL

BRADLEY COMMERCIAL TOILET ACCESSORIES

Willoughby Industries - Security Products

Sunset Point Building 2 BRUSHED NICKEL UPGRADE CONTEMPORARY PACKAGE. Christine Mullineaux th St. North Pinellas Park, FL

Plumbing. September 8, 2018 Prices and product availability are subject to change without notice. 32" Curved Shower Pan with Round Front - Parchment

The Water Efficiency Company. Vitreous China Fixtures

Sunset Point Building 2 BRUSHED NICKEL TRADITIONAL UPGRADE PACKAGE. Christine Mullineaux th St. North Pinellas Park, FL

COMMERCIAL VOLUME PLUMBING

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

DESIGN CRITERIA See Part II for additional information regarding Energy and Water Efficiency, etc.

Model Z TAS. Standards Compliance. Sundara Drift Double Basin Hand Washing System

Plumbing Fixtures CEU 251. Continuing Education from the American Society of Plumbing Engineers. September ASPE.

Plumbing Fixtures CEU 216. Continuing Education from the American Society of Plumbing Engineers. October ASPE.

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

Instructions. Certifications CH Chrome SS Stainless Steel. Single Handle, Industrial Style, Pull-Down Kitchen Faucet.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

Transcription:

SECTION 224000 - PLUMBING FIXTURES PART 1 GENERAL 1.1 SECTION INCLUDES A. Water closets. B. Urinals. C. Lavatories. D. Sinks. E. Service sinks. F. Showers. G. Wash fountains. H. Eye wash fountains. 1.2 RELATED REQUIREMENTS A. Section 079200 - Joint Sealants: Seal fixtures to walls and floors. B. Section 221005 - Plumbing Piping. C. Section 221006 - Plumbing Piping Specialties. D. Section 223000 - Plumbing Equipment. 1.3 REFERENCE STANDARDS A. ANSI Z124.1.2 - American National Standard for Plastic Bathtub and Shower Units; 2005. B. ANSI Z358.1 - American National Standard for Emergency Eyewash and Shower Equipment; 2004. C. ASME A112.6.1M - Supports for Off-the-Floor Plumbing Fixtures for Public Use; The American Society of Mechanical Engineers; 1997 (Reaffirmed 2002). D. ASME A112.18.1 - Plumbing Supply Fittings; The American Society of Mechanical Engineers; 2005. E. ASME A112.19.2 - Vitreous China Plumbing Fixtures and Hydraulic Requirements for Water Closets and Urinals; The American Society of Mechanical Engineers; 2008. PLUMBING FIXTURES 224000-1

F. ASME A112.19.3 - Stainless Steel Plumbing Fixtures (Designed for Residential Use); The American Society of Mechanical Engineers; 2008. G. ASTM E 84 - s of Building Materials; 2010 H. ISSFA-2 - Classification and Standards for Solid Surfacing Material; International Solid Surface Fabricators Association; 2001 (2002) I. NEMA LD 3 - High-Pressure Decorative Laminates; 2005. 1.4 SUBMITTALS A. See Section 013000 - Administrative Requirements, for submittal procedures. B. Product Data: Provide catalog illustrations of fixtures, sizes, rough-in dimensions, utility sizes, trim, and finishes. C. Manufacturer's Instructions: Indicate installation methods and procedures. D. Maintenance Data: Include fixture trim exploded view and replacement parts lists. E. Warranty: Submit manufacturer warranty and ensure forms have been completed in Owner's name and registered with manufacturer. F. Maintenance Materials: Furnish the following for Owner's use in maintenance of project. 1. See Section 016000 - Product Requirements, for additional provisions. 2. Extra Faucet Washers: One set of each type and size. 3. Extra Lavatory Supply Fittings: One set of each type and size. 4. Extra Shower Heads: One of each type and size. 5. Extra Toilet Seats: One of each type and size. 6. Flush Valve Service Kits: One for each type and size. 1.5 REGULATORY REQUIREMENTS 1.6 DELIVERY, STORAGE, AND HANDLING A. Accept fixtures on site in factory packaging. Inspect for damage. B. Protect installed fixtures from damage by securing areas and by leaving factory packaging in place to protect fixtures and prevent use. 1.7 WARRANTY A. See Section 017800 - Closeout Submittals, for additional warranty requirements. PLUMBING FIXTURES 224000-2

B. Provide five year manufacturer warranty for electric water cooler. PART 2 PRODUCTS 2.1 FLUSH VALVE WATER CLOSETS (WC-1) A. Water Closets: Vitreous china, ASME A112.19.2, elongated rim, floor mounted, siphon jet flush action, china bolt caps. 1. Flush Volume: 1.6 gallon (6 liters), maximum. 2. Flush Valve: Exposed (top spud). 3. Flush Operation: Manual, oscillating handle. 4. Supply Size: 1-1/2 inches (38 mm). 5. Outlet Size: 2 inches (50 mm). 6. Manufacturers: a. American Standard Inc: www.americanstandard.com. b. Kohler Company; Model K-4302: www.kohler.com. c. Zurn industries, Inc: www.zurn.com. B. Flush Valves: ASME A112.18.1, diaphragm type, complete with vacuum breaker stops and accessories. 1. Sensor-Operated Type: Solenoid operator, battery powered, infrared sensor and over-ride push button. 2. Exposed Type: Chrome plated, escutcheon, integral screwdriver stop. 3. Manufacturers: a. Coyne & Delany Co: www.coynedelany.com. b. Sloan Valve Company; Model 8111: www.sloanvalve.com. c. Zurn Industries, Inc: www.zurn.com. C. Seats: 1. Manufacturers: a. Bemis Manufacturing Company: www.bemismfg.com. b. Church Seat Company: www.churchseats.com. c. Kohler Company; Model K-4670-CA: www.kohler.com. 2. Solid white plastic, open front, extended back, self-sustaining hinge, brass bolts, without cover. 2.2 FLUSH VALVE WATER CLOSETS (WC-1A; HANDICAPPED) A. Water Closets: Vitreous china, ASME A112.19.2, elongated rim, floor mounted, siphon jet flush action, china bolt caps. PLUMBING FIXTURES 224000-3

1. Flush Volume: 1.6 gallon (6 liters), maximum. 2. Flush Valve: Exposed (top spud). 3. Flush Operation: Manual, oscillating handle. 4. Supply Size: 1-1/2 inches (38 mm). 5. Outlet Size: 2 inches (50 mm). 6. Unit and installation shall comply with the American Disabilities Act Guidelines ADA and ANSI A117.1 requirement for people with disabilities. 7. Manufacturers: a. American Standard Inc: www.americanstandard.com. b. Kohler Company; Model K-4302: www.kohler.com. c. Zurn industries, Inc: www.zurn.com. B. Flush Valves: ASME A112.18.1, diaphragm type, complete with vacuum breaker stops and accessories. 1. Sensor-Operated Type: Solenoid operator, battery powered, infrared sensor and over-ride push button. 2. Exposed Type: Chrome plated, escutcheon, integral screwdriver stop. 3. Manufacturers: a. Coyne & Delany Co: www.coynedelany.com. b. Sloan Valve Company; Model 8111: www.sloanvalve.com. c. Zurn Industries, Inc: www.zurn.com. C. Seats: 1. Manufacturers: a. Bemis Manufacturing Company: www.bemismfg.com. b. Church Seat Company: www.churchseats.com. c. Kohler Company; Model K-4670-CA: www.kohler.com. 2. Solid white plastic, open front, extended back, self-sustaining hinge, brass bolts, without cover. 2.3 WALL HUNG URINALS (U-1A; HANDICAPPED) A. Wall Hung Urinal Manufacturers: 1. American Standard Inc: www.americanstandard.com. 2. Kohler Company: www.kohler.com. PLUMBING FIXTURES 224000-4

3. Zurn Industries, Inc; EcoVantage Z5798 High-Efficiency Urinal System: www.zurn.com. 4. Sloan Valve Company; Model WEUS-1000.1401-0.13 ECOS: www.sloanvalve.com. 5. Substitutions: See Section 016000 - Product Requirements. B. Urinals: Vitreous china, ASME A112.19.2, wall hung with side shields and concealed carrier. 1. Unit and installation shall comply with the American Disabilities Act Guidelines ADA and ANSI A117.1 requirement for people with disabilities. 2. Flush Volume: 0.125 gallon (0.47 liter), maximum. 3. Flush Style: Washout. 4. Flush Valve: Exposed (top spud). 5. Flush Operation: Sensor operated. 6. Trap: Integral. 7. Removable stainless steel strainer. 8. Supply Size: 3/4 inch (19 mm). 9. Outlet Size: 2 inches (50 mm). C. Flush Valves: ASME A112.18.1, diaphragm type, complete with vacuum breaker stops and accessories. 1. Sensor-Operated Type: Solenoid operator, battery powered, infrared sensor and over-ride push button. 2. Exposed Type: Chrome plated, escutcheon, integral screwdriver stop. D. Carriers: 1. Manufacturers: a. JOSAM Company: www.josam.com. b. Zurn Industries, Inc: www.zurn.com. c. Substitutions: See Section 016000 - Product Requirements. 2. ASME A112.6.1M; cast iron and steel frame with tubular legs, lugs for floor and wall attachment, threaded fixture studs for fixture hanger, bearing studs. 2.4 LAVATORIES (L-1A; HANDICAPPED) A. Lavatory Manufacturers: 1. American Standard Inc; Model : www.americanstandard.com. 2. Kohler Company; Model : www.kohler.com. 3. Zurn industries, Inc; Model : www.zurn.com. PLUMBING FIXTURES 224000-5

B. Vitreous China Wall Hung Basin: ASME A112.19.2; vitreous china wall hung lavatory, 19-1/4 by 17-1/4 inch (489 by 438 mm) minimum, with 4 inch (100 mm) high back, rectangular basin with splash lip, front overflow, and soap depression. 1. Unit and installation shall comply with the American Disabilities Act Guidelines ADA and ANSI A117.1 requirement for people with disabilities. 2. Single-hole faucet drilling. C. Sensor Operated Faucet: Cast brass, chrome plated, deck mounted with sensor located on neck of spout. 1. Spout Style: Standard. 2. Power Supply: Battery, easily replaceable, alkaline or lithium, minimum 200,000 cycles. a. Low battery indicator warning light at 30 days remaining life and continuous light a 2 weeks. 3. Mixing Valve: below deck mounted thermostatic mixing valve. 4. Water Supply: 3/8 inch (9 mm) compression connections. 5. Aerator: Vandal resistant, 0.5 GPM (1.89 LPM), laminar flow device. 6. Sensor range: Factory set at a minimum of 3 inch (76 mm) adjustable up to 24 inch (610 mm). 7. Finish: Polished chrome. 8. Sensor Operated Faucet Manufacturers: a. American Standard Inc: www.americanstandard.com. b. The Chicago Faucet Company: www.chicagofaucets.com. c. Moen Incorporated: www.moen.com. d. Sloan Valve Company; Model EBF-650-BDT: www.sloanvalve.com. e. Toto USA: www.totousa.com. f. Zurn industries, Inc: www.zurn.com. D. Accessories: 1. Chrome plated 17 gage (1.3 mm) brass P-trap with clean-out plug and arm with escutcheon. 2. Offset waste with perforated open strainer. 3. Rigid supplies. 4. Carrier: a. Manufacturers: 1) JOSAM Company: www.josam.com. 2) Zurn Industries, Inc: www.zurn.com. 3) Substitutions: See Section 016000 - Product Requirements. b. ASME A112.6.1M; cast iron and steel frame with tubular legs, lugs for floor and wall attachment, concealed arm supports, bearing plate and studs. PLUMBING FIXTURES 224000-6

2.5 SINKS (KS-1) A. Sink Manufacturers: 1. American Standard Inc: www.americanstandard.com. 2. Kohler Company; Model K-3258-3: www.kohler.com. 3. Substitutions: See Section 016000 - Product Requirements. B. Single Compartment Bowl: ASME A112.19.3; 25 by 22 by 8-1/4 inch (635 by 559 by 210 mm) outside dimensions 20 gage (0.9 mm) thick, Type 302 stainless steel, self rimming and undercoated, with ledge back drilled for trim. 1. Drain: 1-1/2 inch (38 mm) chromed brass drain. 2. Drain: 3-1/2 inch (90 mm) crumb cup and tailpiece. 2.6 SHOWER RECEPTORS (S-1A; HANDICAPPED) A. Solid Surfacing Shower Receptors: Solid molded stone casting, self-supporting, for installation over conventional subfloor; complying with ANSI Z124.1.2. 1. Material: Complying with ISSFA-2 and NEMA LD 3; molded stone resin, unfilled, and pigments; homogenous, non-porous and capable of being worked and repaired using standard woodworking tools; no surface coating; color and pattern consistent throughout thickness. 2. Surface Burning Characteristics: Flame spread 25, maximum; smoke developed 450, maximum; when tested in accordance with ASTM E84. 3. Color and Pattern: As selected by Architect from manufacturer's full line. 4. Unit and installation shall comply with the American Disabilities Act Guidelines ADA and ANSI A117.1 requirement for people with disabilities. 5. Manufacturers: a. Fiat Products; Model 36FT: www.fiat.ca b. Substitutions: See Section 016000 - Product Requirements. B. Drain Trim: Removable chrome plated strainer, tail piece. 2.7 WASH FOUNTAINS (SS-1) A. Wash Fountain Manufacturers: 1. Acorn Engineering Company: www.acorneng.com. 2. Bradley Corporation: www.bradleycorp.com. 3. Sloan Valve Company; Model EHS-1750-BDT: www.sloanvalve.com 4. Substitutions: See Section 016000 - Product Requirements. PLUMBING FIXTURES 224000-7

B. Bowl: Rectangular, 19 by 16 by 6 inches (483 mm by 406 mm by 152 mm), 14 gauge type 304 stainless steel. C. Accessories: battery powered, sensor operated controlled self-closing valve with goose neck faucet, spray head, liquid soap dispenser, thermostatic mixing valve, supporting tube, spud and strainer, operating mechanism, combination stop, strainer and check valves. 2.8 SERVICE SINKS (MS-1) A. Service Sink Manufacturers: 1. Just Manufacturing Company: www.justmfg.com. 2. Zurn industries, Inc: www.zurn.com. 3. Fiat Products; Model TSBC1610: www.fiat.ca 4. Substitutions: See Section 016000 - Product Requirements. B. Bowl: 24 by 24 by 12 inch (610 by 610 by 305 mm) high white molded stone, floor mounted, with 2 inch (51 mm) wide shoulders, stainless steel strainer. C. Trim: ASME A112.18.1 exposed wall type supply with cross handles, spout wall brace, vacuum breaker, hose end spout, strainers, eccentric adjustable inlets, integral screwdriver stops with covering caps and adjustable threaded wall flanges. D. Accessories: 1. 5 feet (1.5 m) of 1/2 inch (13 mm) diameter plain end reinforced rubber hose. 2. Hose clamp hanger. 3. Mop hanger. 2.9 EMERGENCY EYE WASH A. Emergency Wash Manufacturers: 1. Bradley Corporation; Model S19-220: www.bradleycorp.com 2. Substitutions: See Section 016000 - Product Requirements. B. Emergency Wash: ANSI Z358.1; wall-mounted, self-cleaning, non-clogging eye wash with quick opening, full-flow valves, ABS eye wash receptor, twin eye wash heads, copper alloy control valve and fittings. PART 3 EXECUTION 3.1 EXAMINATION A. Verify that walls and floor finishes are prepared and ready for installation of fixtures. PLUMBING FIXTURES 224000-8

B. Confirm that millwork is constructed with adequate provision for the installation of counter top lavatories and sinks. 3.2 PREPARATION A. Rough-in fixture piping connections in accordance with minimum sizes indicated in fixture rough-in schedule for particular fixtures. 3.3 INSTALLATION A. Install each fixture with trap, easily removable for servicing and cleaning. B. Provide chrome plated rigid or flexible supplies to fixtures with loose key stops, reducers, and escutcheons. C. Install components level and plumb. D. Seal fixtures to wall and floor surfaces with sealant as specified in Section 079005, color to match fixture. 3.4 INTERFACE WITH WORK OF OTHER SECTIONS A. Review millwork shop drawings. Confirm location and size of fixtures and openings before rough-in and installation. 3.5 ADJUSTING A. Adjust stops or valves for intended water flow rate to fixtures without splashing, noise, or overflow. 3.6 CLEANING A. Clean plumbing fixtures and equipment. 3.7 PROTECTION A. Protect installed products from damage due to subsequent construction operations. B. Repair or replace damaged products before Date of Substantial Completion. 3.8 SCHEDULES A. Fixture Rough-In 1. Water Closet (Flush Valve Type): a. Cold Water: 1 Inch (25 mm). b. Waste: 4 Inch (100 mm). PLUMBING FIXTURES 224000-9

c. Vent: 2 Inch (50 mm). 2. Urinal (Flush Valve Type): a. Cold Water: 3/4 Inch (20 mm). b. Waste: 2 Inch (50 mm). c. Vent: 1-1/2 Inch (40 mm). 3. Lavatory: a. Hot Water: 1/2 Inch (15 mm). b. Cold Water: 1/2 Inch (15 mm). c. Waste: 1-1/2 Inch (40 mm). d. Vent: 1-1/4 Inch (32 mm). 4. Sink: a. Hot Water: 1/2 Inch (15 mm). b. Cold Water: 1/2 Inch (15 mm). c. Waste: 1-1/2 Inch (40 mm). d. Vent: 1-1/4 Inch (32 mm). 5. Service Sink: a. Hot Water: 1/2 Inch (15 mm). b. Cold Water: 1/2 Inch (15 mm). c. Waste: 3 Inch (80 mm). d. Vent: 1-1/2 Inch (40 mm). 6. Shower: a. Hot Water: 1/2 Inch (15 mm). b. Cold Water: 1/2 Inch (15 mm). c. Waste: 1-1/2 Inch (40 mm). d. Vent: 1-1/4 Inch (32 mm). END OF SECTION PLUMBING FIXTURES 224000-10