User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

Similar documents
User and Installation Instructions. Electric Auto-Fill Water Boilers EB3F, EB4F, EB6F, EB6TF IS339 ECN3539

Installation, Operating and Servicing Instructions

USER INSTRUCTION MANUAL. Autofill Water Boiler

INSTALLATION AND USER INSTRUCTIONS

The Professional s Choice

User and Installation Instructions C6R/75, C6R/100, C6R/105, C6R/125, C6R/130, D6R/100, D6R/125, D5R/100, D5R/125, D3R/100

The Professional s Choice

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions. Silverlink 600 Electric Pasta Boilers PB33, PB66

INSTALLATION AND USER INSTRUCTIONS

Installation, Operating and Servicing Instructions. Lynx 400 Electric Salamander Grill LGT

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions. Lynx 400 Heavy-Duty Contact Grill GG1, GG1R, GG1P

Autofill counter top water boiler

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions. Opus 700 Electric Salamander Grill OE7304

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions. Seal Heated Display Bars HB1, HB2, HB3, HB4, LD2, LD3, LD4

The Professional s Choice

Installation, Operating and Servicing Instructions. Opus 800 Electric Cook & Hold Salamander OE8306

Installation, Operating and Servicing Instructions

MIX Boiler & Font Range Service Manual

INSTALLATION AND USER INSTRUCTIONS COUNTERTOP AND FREE STANDING FRYERS

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

User and Installation Instructions. Opus 700 Electric Wet Well Bain Marie OE7601 IS195 ECN2396

Autofill Wall Mount Boilers

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

USER INSTRUCTION MANUAL. Autofill Wall Mount Boilers /12/14

User, Installation and Servicing Instructions. Silverlink 600 Gas Griddles GS4 and GS7 IS212 ECN3592

Mix Boiler & Font Range ( #, #, #, , )

Installation, Operating and Servicing Instructions

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

AQUARIUS 45 MARINE SERVICE MANUAL

INSTALLATION, USER AND SERVICING INSTRUCTIONS FOR ESLR9C OVEN RANGE

Autofill Wall Mount Boilers

User and Installation Instructions. Opus 700 Electric Salamander Grill OE7304 IS318 ECN3011

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages.

Ecoboiler SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

EcoSmart boiler SERVICE MANUAL

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.

Installation, Operating and Servicing Instructions

LT4X AND LT6X Electric Slot Toasters

OPUS Electric Chip Scuttle OE7109 USER /INSTALLATION INSTRUCTIONS

T5 ( ) T10 ( ) PB5 ( ) PB10

Autofill Countertop Boilers

Installation, Operating and Servicing Instructions

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

Mira Sport Max with Airboost

ELECTRIC WATER BOILER

Zen Boiling Tap Range

User, Installation and Servicing Instructions. Panther Hot Cupboards GB2, GB3, GBM2, GBM3, GX2, GX3, GM2, GM3 IS70 ECN 1755

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

UNDERCOUNTER SERVICE MANUAL. Ecoboiler UC4L 2.4kW Ecoboiler UC10L 2.8kW Ecoboiler UC10L 5.6kW Ecosmart UC4L 2.

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

IS09 ECN2087. EB3, EB4 & EB6 Automatic Fill Water Boilers INSTALLATION, USER & SERVICING INSTRUCTIONS

CONTENT PAGE INFORMATION INSTALLATION BREWER SETUP BREWING CLEANING KEY BREWER GRINDER MANUAL MODE DILUTION GRINDER MODE PACKS MODE

Calomax Limited Lupton Avenue, Leeds LS9 7DD Tel Fax

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Zip Hydroboil. Instant boiling water. Installation and Operating Instructions

EDEN. Installation Instructions. Bath shower manual mixer tap INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

Paper Shredder. Installation & User Instructions Please keep for future reference 913/0153

User Instruction Manual

Actual product may differ from the one illustrated

Zip Hydroboil. Instant boiling water. Installation and Operating Instructions

User and Installation Instructions. Seal Refrigerated Merchandisers

Hot Water Urns v3.0. all models. Helpline. instructions.indd 1 02/06/ :50

OG7302 Salamander Grill

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

Zip Autoboil Installation and Operating Instructions

Installation, Operating and Servicing Instructions

Marco Beverage Systems Ltd. INSTRUCTIONS FOR MODELS

Zip Econoboil 1.5 litre White Zip Econoboil 3.0 litre White Zip Econoboil 5.0 litre White Zip Econoboil 7.

Marco Beverage Systems Ltd.

4L Instant Water Boiler Instructions for Use

ProAction. Paper Shredder. Installation & User Instructions Please keep for future reference 903/1537

Thermostatic Concealed Shower Valve

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS

KETTLE INSTRUCTION MANUAL

INSTRUCTION MANUAL KETTLE

IMPORTANT SAFEGUARDS Ensure that your mains supply voltage is the same as that marked on the underside of your kettle.

Please read and keep these instructions for future use

OE7008 & OE7010 Electric Oven Ranges

Calomax Limited Lupton Avenue, Leeds LS9 7DD Tel Fax

Installation, Operating and Servicing Instructions. Opus 800 Gas Open Top Oven Ranges OG8001 & OG8002

HOT WASHER MODEL NO: KING150

One Cup. Please read and keep these instructions for future use

AUTOMATIC GRANULAR ICE FLAKER

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

User Guide. Please read carefully before use. Your Hoover Guarantee. Your Hoover Guarantee. Contents. IMPORTANT Safety Reminders

Transcription:

User and Installation Instructions Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

Dear Customer Thank you for purchasing this Lincat product. With correct use and careful maintenance as described in these instructions, your Lincat product will give years of trouble free use. We produce over 450 different items of catering equipment and our range is constantly being extended and improved. Find out more about Lincat products from your local distributor or direct from us. CONTENTS CONTENTS...2 SAFETY INFORMATION...3 DELIVERY CHECKLIST...4 TECHNICAL SPECIFICATION...4 ACCESSORIES...4 INSTALLATION...4 OPERATION...5 CLEANING...8 MAINTENANCE...9 DIAGNOSTIC MESSAGES...11 SERVICE INFORMATION...11 GUARANTEE...12 IS435 ECN3461 2

SAFETY INFORMATION To prevent injury to yourself or your staff, and to avoid damaging the product, please read and follow the safety precautions below before setting up and using the unit: Remove all plastic coatings and clean the unit before use. Always isolate the unit from the electricity supply before servicing. This unit must be earthed. Do not try to modify this unit. Never clean the unit with a water jet or steam cleaner. This unit is not suitable for outdoor use. Inform staff that the outer surfaces will become hot. Keep these instructions in a safe place near the unit for future reference. IS435 ECN3461 3

DELIVERY CHECKLIST If an item is missing please contact your dealer immediately. Electric water boiler User instructions Guarantee card 44mm diameter rubber grommet Note: No supply cable or connection hose is supplied with this unit TECHNICAL SPECIFICATION Model WMB3F Width mm 300 Depth mm 185 Exc. tap Height mm 415 Power Rating kw 3.0 Net weight (empty) kg 8.5 Net weight (full) kg 14.5 Ambient temperature o C 5 to 30 Water inlet pressure Bar 1 to 8 OPTIONAL ACCESSORIES Replacement filter cartridge Drip tray FC02 DR72 MECHANICAL INSTALLATION The boiler must be installed on a vertical surface, with the base in a horizontal position, in a location where it can be supervised by trained personnel. Ensure that the location it is fitted in is frost-free. WARNING The unit must be installed on a solid concrete / brick wall by a qualified fitter. Lincat does not accept any responsibility for the safety of any unit not installed this way. Use the template provided, IS436, to mark the position of the 3 mounting holes. Drill the wall and insert suitable wall plugs. Remove the glass front / outer body of the boiler. Loosen the screw holding the lower centre trim, slide the trim forward, re-tighten the screw. Remove the screw in the top of the boiler. Lock open the drain tap. Carefully slide the the glass front and metal sides upwards and away from the unit. Secure the boiler to the wall using 5mm (10g) screws. IS435 ECN3461 4

ELECTRICAL INSTALLATION For safety regulations the plug or means of disconnection must always be accessible. This boiler must be earthed. Check that the voltage of your electricity supply corresponds to the voltage shown on the serial plate. The boiler is supplied with a terminal block suitable for flexible wires upto 6mm 2. Connection wires may either be threaded through the cutout in the back panel or via a suitable 20mm diameter glanded bush in the unit base (After removing the smaller of the two knock out panels, marked B.) Connection sequence is as detailed below E Earth Green / Yellow Right terminal N Neutral Blue Centre terminal L Live Brown Left terminal WATER INSTALLATION Connection hoses may either be fed through the cutout in the back panel or via the larger of the two knock out panels in the unit base, marked A. A blank rubber grommet is supplied and should be cut to fit around the feed pipe and fitted into the unit base to seal it. The inlet connection point on the inlet solenoid valve is ¾ BSP and should be connected to the mains water supply via an accessible isolating tap. Connect the condesate / overflow pipe to a suitable drain, considering any applicable local water regulations. If required, the internal pipe may be disconnected from the external connector and the pipe extended to pass through the cutout in the back panel and connected to a suitable drain. Turn on the water supply to check that there are no leaks. Refit the outer cover. IS435 ECN3461 5

OPERATION Layout of components 1 2 Key 4 5 3 1. Power Button 2. Fn Button 3. Filter 4. Knock-out for water 5. Knock-out for power 6. Grommet for tank drain 7. Overflow pipe 7 6 IS435 ECN3461 6

First use 1 Switch on the mains water supply and the electricity supply. 2 Leave the boiler for 15 minutes to allow it to fill completely. 3 Drain off approximately 3 litres of water to remove any loose carbon particles dislodged from the filter. Regular operation The boiler starts automatically when the mains electrical supply is turned on. After a short delay the unit fills with water and heats. During the heating cycle small quantities of water are added to ensure that hot water is always available at the tap. The water temperature, screen backlight and screen contrast can be adjusted as required. The boiler is designed to be left permanently switched on: it is only necessary to turn it off for descaling or maintenance. Changing water temperature, screen backlight and contrast. 1 Turn power off at the wall for 5 seconds and then turn on again. 2 When the Filter Flow screen is displayed, press and hold the power button until the software version is displayed. Press Fn and the temperature will be displayed. 3 Press the power button to cycle through the values 70 to 96 deg C. Press the Fn button to select the required value. 4 The backlight adjustment screen is displayed next. 5 Press the power button to cycle through the values 1 to 25. Press the Fn button to select the required value. 6 The contrast adjustment screen is displayed next. 7 Press the power button to cycle through the values 35 to 60. Press the Fn button to select the required value. 8 Press the power button to exit. Standby If the boiler is to be left unused for a long period, the element can be turned off by pressing the power button. IS435 ECN3461 7

Filter replacement The FILTER display shows the estimated remaining life in the current filter cartridge. When the filter needs replacing, a reminder message is displayed. This is followed by the change filter screen. The boiler can be used without a filter but scale may build up more quickly and water taste may be affected. Replace the filter as follows: 1 Twist the base of the filter 90 degrees to the left and carefully lower the filter cartridge out of the unit. It will contain a small amount of water. 2 Remove the black cap and place on the new filter. 3 Insert the filter fully into its recess and twist to the right to lock in place. 4 Press and hold the Fn button for 10 seconds to reset the filter life monitor. 5 Drain off approximately 3 litres of water to remove any loose carbon particles from the filter. CLEANING Clean the external surfaces of the unit regularly to maintain hygiene. Wipe the dispensing tap daily to remove any limescale deposits and check that the water outlet is clear. Wipe the unit down with a damp soft cloth. Do not allow excess water to run into the unit. Do not use abrasive creams or scourers. IS435 ECN3461 8

MAINTENANCE Filter: Twist to the left and remove. See section on filter replacement. Descaling The descaling procedure must be performed by trained personnel as it requires the removal of panels from the boiler and access to live electrical components. The boiler should be descaled regularly to maintain efficient operation and water quality. The frequency depends on the hardness of the local water and the timely replacement of the filter. The boiler is best descaled at the end of the working day to allow the descaling agent several hours to work. Lincat recommends its own descaling agent, available from Lincat spares department, part code MS19. 1 Wear protective clothing. 2 Isolate the boiler from the electricity supply. 3 Turn off the power and let the water cool to approximately 60ºC to avoid injury. 4 Remove the screw on the top of the boiler and slide off the body. 5 Remove the insulation on top of the tank, then unscrew and remove the tank lid. 6 Add the descaling agent a little at a time as some types can cause hot water to erupt. Always follow the manufacturer s instructions. 7 Replace the tank lid and outer body, and attach an Out of Use notice to the boiler to prevent use during descaling. 8 Turn on the electricity and allow the boiler to heat and run normally for approximately 30 minutes. 9 Isolate the boiler and allow the water to cool. 10 Remove the outer body and tank lid and inspect the tank and level sensor housings for scale deposits. If necessary repeat the descaling process. 11 Drain and flush all descaling agent from the tank completely as follows i Unscrew the drain plug (Use a 24mm spanner to hold the plug and a 21mm socket on a ratchet to remove it) from the bottom of the tank to drain all the water out. IS435 ECN3461 9

A DETAIL A ii Flush out the tank with clean water. iii When empty replace the drain plug and replace the cover. 12 Replace the tank lid, ensuring that the gasket is sealing the top of the tank correctly. 13 Fit the outer cover and turn on the boiler. IS435 ECN3461 10

DIAGNOSTIC MESSAGES The control panel displays messages and information that can help with fault diagnosis. Before calling for service, draw off a litre of water, clear the fault code by pressing the Fn button and turn the boiler off and on again at the mains supply. If the fault persists call the service department for advice. Message Displayed Possible cause Corrective action Scale on level sensors Boiler overfilling Descale. Check water inlet valve Water turned off Inlet hose bent or blocked Water pressure too high or low Drain valve open Check water supply and drain valve. Call service if fault persists Boil-dry / overheat protector tripped Temperature sensor fault Element failed PCB fault Faulty / loose connection Temperature set too high Temperature sensor fault Boiler not filling Excessive scale in tank PCB fault Isolate the unit, wait for 30 minutes, then turn on again. Check connections. Call service if fault persists Reduce temperature setting and try again. Call service if fault persists Temperature sensor fault Call service IS435 ECN3461 11

SERVICE INFORMATION For help with the installation, maintenance and use of your Lincat equipment, please contact our service department: UK: 01522 875520 All service work, other than routine cleaning should be carried out by one of our authorised service agents. We cannot accept responsibility for work carried out by other persons. To ensure your service enquiry is handled as efficiently as possible, please tell us: Brief details of the problem Product code Type number } From serial plate (beside dispensing tap) Serial number Lincat reserve the right to carry out any work under warranty during normal working hours, Monday to Friday, 08:30 am to 17:00 pm. GUARANTEE This unit carries a comprehensive UK twelve-month warranty. The guarantee is in addition to, and does not diminish your statutory or legal rights. The guarantee does not cover: Accidental damage, misuse or use not in accordance with the instructions in these instructions Consumable items Damage due to incorrect installation, modification, unauthorised service work or damage due to scale The manufacturer disclaims any liability for incidental, or consequential damages IS435 ECN3461 12

This page intentionally left blank IS435 ECN3461 13