MODELS DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL FTXL20G2V1B FTXL25G2V1B FTXL35G2V1B

Similar documents
MODELS DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL FTXN50KV1B FTXN60KV1B. R410A Split Series

MODELS DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL FTXS20K2V1B FTXS25K2V1B CTXS15K2V1B CTXS35K2V1B. R410A Split Series

MODELS DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL. R410A Split Series

INSTALLATION MANUAL. R410A Split Series

INSTALLATION MANUAL. R410A Split Series. Models ATX20J2V1B ATX25J2V1B ATX35J2V1B. Installation manual R410A Split series

INSTALLATION MANUAL. R410A Split Series. Models. Installation manual R410A Split series. Installationsanleitung Split-Baureihe R410A

INSTALLATION MANUAL MODELS DAIKIN ROOM AIR CONDITIONER. R410A Split Series. Installation manual Manuel d installation Manual de instalación

INSTALLATION MANUAL. R410A Split Series

INSTALLATION MANUAL. R22 Split Series. Models FTY25GXV1 FTY35GXV1. Installation manual R22 Split series

MULTI HEAT PUMP PANEL CONSOLE TYPE DUCTLESS INVERTER INDOOR UNIT INSTALLATION MANUAL. Models: CH09MCU230VI CH12MCU230VI CH18MCU230VI

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

INSTALLATION MANUAL. R-410A Split Series. Models. Installation manual R-410A Split series. Installationsanleitung Split-Baureihe R-410A

INSTALLATION MANUAL. R410A Split Series. Models FVXS25FV1B FVXS35FV1B FVXS50FV1B. Installation manual R410A Split series

English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL. Français. R410A Split Series. Español MODELS FTXS09LVJU FTXS12LVJU CTXS07LVJU

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

INSTALLATION MANUAL. R410A Split Series. Models ARX20GV1B ARX25GV1B ARX35GV1B ARX20JV1B ARX25JV1B ARX35JV1B. Installation manual R410A Split series

DAIKIN AIR CONDITIONER

INSTALLATION MANUAL. R410A Split Series. Models. Installation manual R410A Split series. Installationsanleitung Split-Baureihe R410A

INSTALLATION MANUAL. R410A Split Series. Models. Installation manual R410A Split series. Installationsanleitung Split-Baureihe R410A

INSTALLATION MANUAL. R410A Split Series. Model RXS24LVJU. Installation manual R410A Split series. Manual de instalación Serie Split R410A.

INSTALLATION MANUAL. R410A Split Series. Models RXS15LVJU RXS18LVJU. Installation manual R410A Split series. Manuel dinstallation Série split R410A

INSTALLATION MANUAL. R410A Split Series. Models RXS20K2V1B RXS25K2V1B. Installation manual R410A Split series

INSTALLATION MANUAL. R410A Split Series. Models RN60E3V1B. Installation manual R410A Split series. Installationsanleitung Split-Baureihe R410A

Safety Precautions (1)

INSTALLATION MANUAL. R410A Split Series. Models. Installation manual R410A Split series. Installationsanleitung Split-Baureihe R410A

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL. R410A Split Series. Models 3MXS40K2V1B. Installation manual R410A Split series. Installationsanleitung Split-Baureihe R410A

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. R410A Split Series. Models. Installation manual R410A Split series. Installationsanleitung Split-Baureihe R410A

INSTALLATION MANUAL. R32 Split Series MODELS FTXZ25NV1B RXZ25NV1B RXZ35NV1B RXZ50NV1B FTXZ35NV1B FTXZ50NV1B. Installation manual R32 Split series

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

BOARD HEATER / A/C OWNER S MANUAL GEH(18)AA-D3DNA1C/I GEH(12)AA-D3DNA1C/I GEH(09)AA-D3DNA1C/I MODELS

INVERTER SPLIT - TYPE

INSTALLATION MANUAL. R410A Split Series. Models. Installation manual R410A Split series. Installationsanleitung Split-Baureihe R410A

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

INSTALLATION MANUAL. BP (Branch Provider) Unit. Models BPMKS967A2B BPMKS967A3B BPMKS967B2B BPMKS967B3B. Installation manual BP (Branch Provider) Unit

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

1. BEFORE INSTALLATION

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

[FLARE CONNECTION TYPE] ATTENTION

42PHW / 42PHQ 42PHQ...K

INSTALLATION MANUAL R410A Split Series

Air Conditioner. user installation & manual manual. imagine the possibilities

Split-type Air-Conditioner

CONTENTS INSTALLATION MANUAL HFC FOR INSTALLER R410A. utilized 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2

1. BEFORE INSTALLATION

Installation manual for room air conditioner

FLOOR TYPE AIR CONDITIONERS

Split-type Air-Conditioner

AIR CONDITIONER (SPLIT TYPE) Installation Manual. Indoor Unit. Installation Manual 1 English. Kurulum kılavuzu 26 Türkçe.

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

1. BEFORE INSTALLATION

Split Air Conditioner. Model: WMI09MH16S WMI12MH16S WMI18MH16S

CENTRAL AIR CONDITIONER SPLIT SYSTEM

Installation Manual MMU-AP0154SH-E MMU-AP0184SH-E MMU-AP0244SH-E AIR CONDITIONER (MULTI TYPE) Indoor Unit. Model name: 1-Way Cassette Type.

Installation Manual AIR CONDITIONER (SPLIT TYPE) Indoor Unit RAV-SP180CT-UL RAV-SP240CT-UL RAV-SP300CT-UL RAV-SP360CT-UL RAV-SP420CT-UL.

SPLIT WALL-MOUNTED AIR CONDITIONER

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

ROOM AIR CONDITIONER INSTALLATION MANUAL

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

Installation Instructions

MULTI TYPE ROOM AIR CONDITIONERS INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL. AIR CONDITIONER Wall Mounted Type. PART No Contents 1. SAFETY PRECAUTIONS 2. ABOUT THIS PRODUCT.

SPLIT TYPE ROOM AIR CONDITIONER INSTALLATION MANUAL (PART NO )

Installation Instructions

Installation Instructions

INSTALLATION MANUAL For authorized service personnel only.

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

Split-type Air-Conditioner

RAV-SM567CTP-E RAV-SM807CTP-E RAV-SM1107CTP-E RAV-SM1407CTP-E RAV-SM1607CTP-E

RAV-SM566KRT-E RAV-SM806KRT-E

AIR CONDITIONER BRANCH BOX INSTALLATION MANUAL. For authorized service personnel only. [UTP-PY03A] [UTP-PY02A] PART NO.

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1

Installation Manual AIR CONDITIONER (SPLIT TYPE) Indoor Unit RAV-SM404SDT-E RAV-SM454SDT-E RAV-SM564SDT-E. Model name: Slim Duct Type.

INSTALLATION MANUAL. R410A Split Series. Models 2MXS40BVMB 2MKS40BVMB 2AMXS40BVMB 2AMKS40BVMB. Installation manual R410A Split series

AS09HPAN AS12HPAN. Split-type Air Conditioner (Cooling and Heating)

1. BEFORE INSTALLATION

HFC 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY 2. SELECTING THE INSTALLATION LOCATION R410A INSTALLATION MANUAL

AIR CONDITIONER (MULTI TYPE) Installation Manual. Indoor Unit. Model name:

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Installation Instructions

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

Self Cleaning decoration panel

SUPER MODULAR MULTI SYSTEM AIR CONDITIONER

INSTALLATION MANUAL. AIR CONDITIONER Indoor Unit (Duct type) PART No Contents. En-1 1. SAFETY PRECAUTIONS WARNING

1. BEFORE INSTALLATION

HFC 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY 2. SELECTING THE INSTALLATION LOCATION

INSTALLATION MANUAL. AIR CONDITIONER INDOOR UNIT (Wall Mounted Type) PART No Contents 1. SAFETY PRECAUTIONS. En-1. English.

Installation Manual AIR CONDITIONER (SPLIT TYPE) Indoor Unit RAV-SM1403DT-A RAV-SM1603DT-A. Model name: Concealed Duct High Static Pressure Type

INSTALLATION INSTRUCTIONS

R32 INSTALLATION MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-10PKVPG-E RAS-13PKVPG-E RAS-16PKVPG-E

Transcription:

R410A Split Series English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL Installation manual Installationsmanual Installationshandbok Installasjonshåndbok Asennusohje Paigaldusjuhend Montavimo vadovas Suomi Norsk Svenska Dansk Installierungshandbuch Manuel d installation Ðóêîâîäñòâî ïî ìîíòàæó Instrukcja montazu Installatie Handleiding Français Deutsch Рóссêий Polski Nederlands MODELS FTXL20G2V1B FTXL25G2V1B FTXL35G2V1B

Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan DAIKIN INDUSTRIES, LTD. Low Voltage 2006/95/EC Electromagnetic Compatibility 2004/108/EC * Noboru Murata Manager Quality Control Department 1st. of Sep. 2008 DAIKIN.TCF.015 M3/07-2008 KEMA Quality B.V. 74736-KRQ/EMC97-4957 FTXL20G2V1B, FTXL25G2V1B, FTXL35G2V1B 3SB64417-1

Safety Precautions The precautions described herein are classified as WARNING and CAUTION. They both contain important information regarding safety. Be sure to observe all precautions without fail. Meaning of WARNING and CAUTION notices WARNING... Failure to follow these instructions properly may result in personal injury or loss of life. CAUTION... Failure to observe these instructions properly may result in property damage or personal injury, which may be serious depending on the circumstances. The safety marks shown in this manual have the following meanings: Be sure to follow the instructions. Be sure to establish an earth connection. Never attempt. After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate the air conditioner and take care of it with the aid of the operation manual. WARNING Ask your dealer or qualified personnel to carry out installation work. Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fire. Install the air conditioner in accordance with the instructions in this installation manual. Improper installation may result in water leakage, electric shocks or fire. Be sure to use only the specified accessories and parts for installation work. Failure to use the specified parts may result in the unit falling, water leakage, electric shocks or fire. Install the air conditioner on a foundation strong enough to withstand the weight of the unit. A foundation of insufficient strength may result in the equipment falling and causing injury. Electrical work must be performed in accordance with relevant local and national regulations and with instructions in this installation manual. Be sure to use a dedicated power supply circuit only. Insufficiency of power circuit capacity and improper workmanship may result in electric shocks or fire. Use a cable of suitable length. Do not use tapped wires or an extension lead, as this may cause overheating, electric shocks or fire. Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal connections or wires. Improper connections or securing of wires may result in abnormal heat build-up or fire. When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires so that the control box lid can be securely fastened. Improper positioning of the control box lid may result in electric shocks, fire or over heating terminals. If refrigerant gas leaks during installation, ventilate the area immediately. Toxic gas may be produced if the refrigerant comes into contact with fire. After completing installation, check for refrigerant gas leakage. Toxic gas may be produced if the refrigerant gas leaks into the room and comes into contact with a source of fire, such as a fan heater, stove or cooker. When installing or relocating the air conditioner, be sure to bleed the refrigerant circuit to ensure it is free of air, and use only the specified refrigerant (R410A). The presence of air or other foreign matter in the refrigerant circuit causes abnormal pressure rise, which may result in equipment damage and even injury. During installation, attach the refrigerant piping securely before running the compressor. If the compressor is not attached and the stop valve is open when the compressor is run, air will be sucked in, causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury. During pump-down, stop the compressor before removing the refrigerant piping. If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed, causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury. Be sure to earth the air conditioner. Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing may result in electric shocks. Be sure to install an earth leakage breaker. Failure to install an earth leakage breaker may result in electric shocks or fire. CAUTION Do not install the air conditioner at any place where there is a danger of flammable gas leakage. In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out. While following the instructions in this installation manual, install drain piping to ensure proper drainage and insulate piping to prevent condensation. Improper drain piping may result in indoor water leakage and property damage. Tighten the flare nut according to the specified method such as with a torque wrench. If the flare nut is too tight, it may crack after prolonged use, causing refrigerant leakage. 1 English

Accessories Indoor unit A L, English A Mounting plate 1 E Remote controller holder. 1 K Operation manual 2 B Titanium Apatite Photocatalytic Air-Purifying Filter 2 G Dry batteries AAA. LR03 (alkaline) 2 L Installation manual 1 D Wireless remote controller 1 H Indoor unit fixing screws (M4 12L) 2 Choosing an Installation Site Before choosing the installation site, obtain user approval. 1. Indoor unit. The indoor unit should be sited in a place where: 1) the restrictions on installation specified in the indoor unit installation drawings are met, 2) both air intake and exhaust have clear paths met, 3) the unit is not in the path of direct sunlight, 4) the unit is away from the source of heat or steam, 5) there is no source of machine oil vapour (this may shorten indoor unit life), 6) cool (warm) air is circulated throughout the room, 7) the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may shorten the remote controller range, 8) the unit is at least 1 metre away from any television or radio set (unit may cause interference with the picture or sound), 9) install at the recommended height (1.8m). 2. Wireless remote controller. 1) Turn on all the fluorescent lamps in the room, if any, and find the site where remote controller signals are properly received by the indoor unit (within 7 metres). English 2

Installation Tips 1. Removing and installing front panel. Removal method Hook fingers on the panel protrusions on the left and right of the main body, and open until the panel stops. Slide the front panel sideways to disengage the rotating shaft. Then pull the front panel toward you to remove it. Installation method Align the tabs of the front panel with the grooves, and push all the way in. Then close slowly. Push the center of the lower surface of the panel firmly to engage the tabs. Push the rotating shaft of the front panel into the groove. 2. Removing and installing front grille. Removal method 1) Remove front panel to remove the air filter. 1) Remove the front grille. 2) In front of the mark of the front grille, there are 3 upper hooks. Lightly pull the front grille toward you with one hand, and push down on the hooks with the fingers of your other hand. Upper hook Lightly pull the front grille toward you with one hand, and push down on the hooks with the fingers of your other hand. (3 locations) Push down. mark area (3 locations) Upper hook Upper hook When there is no work space because the unit is close to ceiling CAUTION Be sure to wear protection gloves. Place both hands under the center of the front grille, and while pushing up, pull it toward you. Installation method 1) Install the front grille and firmly engage the upper hooks (3 locations). 2) Install 2screws of the front grille. 3) Install the air filter and then mount the front panel. 1) Push up. 2) Pull toward you. 3 English

3. How to set the different addresses. When 2 indoor units are installed in 1 room, the 2 wireless remote controllers can be set for different addresses. 1) Remove the metal plate electrical wiring cover. (Refer to the Removal/attachment methods of metal plate electrical wiring covers.) 2) Cut the address jumper (JA) on the printed circuit board. 3) Cut the address jumper (J4) in the remote controller. ADDRESS JA JA ADDRESS EXIST 1 CUT 2 J4 English 4. When connecting to an HA system. (Wired remote controller, central remote controller etc ) 1) Remove the metal plate electrical wiring cover. (Refer to the Removal/attachment methods of metal plate electrical wiring covers.) 2) Attach the connection cord to the S21 connector and pull the harness out through the notched part in the figure. 3) Replace the electrical wiring cover as it was, and pull the harness around, as shown in the figure. HA connector (S21) J4 ADDRESS EXIST 1 CUT 2 HA connector (S21) Lay the HA cord as shown in the figure. Removal methods of metal plate electrical wiring covers There are 2 types of metal plate electrical wiring cover, i.e., Type A or Type B. Remove them as shown below. Type A 1) Remove the front grille. 2) Remove the electrical wiring box. (1 screw) 3) Raise the 2 upper parts of the metal plate electrical wiring cover, pull the parts frontward, and remove the 3 tabs. 4) Slide the metal plate electrical wiring cover upward and remove the 2 tabs on the lower side. 3) Raise the 2 upper parts of the metal plate electrical wiring cover, pull the parts frontward, and remove the 3 tabs. Pull Tab Slide Pull Pull 4) Slide the metal plate electrical wiring cover upward and remove the 2 tabs on the lower side. Slide Slide Tab Type B <Difference between Type A and Type B> 1) Steps 1) and 2) are the same as those for Type A. 3) Pull the metal plate electrical wiring cover frontward and remove the 4 tabs. Screw 2) Remove the electrical wiring box. (1 screw) Type A Type B English 4

Installation Tips Attachment methods of metal plate electrical wiring covers Attach the metal plate electrical wiring covers as shown below. Type A 1) Lean the metal plate electrical wiring cover as shown in the figure and attach tab (1) on the lower side to the electrical wiring box. 2) Attach tab (2) on the lower side of the metal plate electrical wiring cover. Tab (1) Tab (1) Tab (2) 3) Push in the upper part of the metal plate electrical wiring cover and attach the 3 tabs. Tab CAUTION Make sure that the shaded part ( ) will not go inside the electrical wiring box. Type B 4 tabs Attach the 4 tabs securely to the positions shown in the figure. CAUTION Make sure that the shaded part ( ) will not go inside the electrical wiring box. 5 English

Indoor Unit Installation Drawings English A Mounting plate How to attach the indoor unit. Hook the claws of the bottom frame to the mounting plate. If the claws are difficult to hook, remove the front grille. How to remove the indoor unit. Push up the marked area (at the lower part of the front grille) to release the claws. If it is difficult to Front grille release, remove the front grille. Bottom frame A Mounting plate Clip Mark (rear side) The mounting plate should be installed on a wall which can support the weight of the indoor unit. Screws (Field supply: M4 25L) Front panel 30mm or more from ceiling Caulk pipe hole gap with putty. Cut thermal insulation pipe to an appropriate length and wrap it with tape, making sure that no gap is left in the insulation pipe s cut line. 50mm or more from walls (on both sides) Intelligent-eye sensor Wrap the insulation pipe with the finishing tape from bottom to top. Air filters M4 16L B Titanium Apatite Photocatalytic Air-Purifying Filter (2) Titanium Apatite Photocatalytic Air-Purifying Filter Service lid Opening service lid Service lid is opening/closing type. Opening method 1) Remove the service lid screws. 2) Pull out the service lid diagonally down in the direction of the arrow. 3) Pull down. Filter frame Tab Air filter D Wireless remote controller Before screwing the remote controller holder to the wall, make sure that control signals are properly received by indoor unit. Screws (Field supply: M3 20L) E Remote controller holder Intelligent-eye sensor CAUTION 1) Do not hit or violently push the Intelligent-eye sensor. This can lead to damage and malfunction. 2) Do not place large objects near the sensor. Also keep heating units or humidifiers outside the sensor s detection area. English 6

Indoor Unit Installation 1. Installing the mounting plate. The mounting plate should be installed on a wall which can support the weight of the indoor unit. 1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring points on the wall. 2) Secure the mounting plate to the wall with screws. Recommended mounting-plate retention spots and Dimensions Recommended mounting plate retention spots. (5 spots in all) 115 Bilt size: M10 56.5 147.5 Place a leveler on raised tab. 450 103 400 200 Bilt size: M10 36 Use tape measure as shown. Position the end of a tape measure at. 295 44.5 45.5 φ65 φ65 45.5 44.5 60.5 Through the wall hole φ65mm Drain hose position 61 149 Liquid pipe end Gas pipe end 175.5 60.5 278.5 50 Keep here the piece cut out 800 from the unit for piping. * The removed pipe port cover can be kept in the mounting plate pocket. Removed pipe port cover A Mounting plate 7 English

2. Boring a wall hole and installing wall embedded pipe. For walls containing metal frame or metal board, be sure to use a wall embedded pipe and wall cover in the feed-through hole to prevent possible heat, electrical shock, or fire. Be sure to caulk the gaps around the pipes with caulking material to prevent water leakage. 1) Bore a feed-through hole of 65mm in the wall so it has a down slope toward the outside. 2) Insert a wall pipe into the hole. 3) Insert a wall cover into wall pipe. 4) After completing refrigerant piping, wiring, and drain piping, caulk pipe hole gap with putty. Inside Wall embedded pipe (Field supply) Wall hole cover (Field supply) Outside Caulking φ65 Wall embedded pipe (Field supply) English 3. Installing indoor unit. 3-1. Right-side, right-back, or right-bottom piping. 1) Attach the drain hose to the underside of the refrigerant pipes with an adhesive vinyl tape. 2) Wrap the refrigerant pipes and drain hose together with an insulation tape. Remove pipe port cover here for right-side piping. Right-bottom piping Remove pipe port cover here for right-bottom piping. Right-back piping Bind coolant pipe and drain hose together with insulating tape. 3) Pass the drain hose and refrigerant pipes through the wall hole, then set the indoor unit on the mounting plate hooks by using the markings at the top of the indoor unit as a guide. A Mounting plate 4) Open the front panel, then open the service lid. (Refer to Installation tips) 5) Pass the interconnecting wires from the outdoor unit through the feed-through wall hole and then through the back of the indoor unit. Pull them through the front side. Bend the ends of tie wires upward for easier work in advance. (If the interconnecting wire ends are to be stripped first, bundle wire ends with adhesive tape.) 6) Press the bottom frame of the indoor unit with both hands to set it on the mounting plate hooks. Make sure the wires do not catch on the edge of the indoor unit. When stripping the ends of interconnecting wires in advance, bind right ends of wires with insulating tape. Hang indoor unit s hook here. A Mounting plate Interconnecting wires English 8

Indoor Unit Installation 3-2. Left-side, left-back, or left-bottom piping. 1) Attach the drain hose to the underside of the refrigerant pipes with adhesive vinyl tape. Remove pipe port cover here for leftside piping. 2) Be sure to connect the drain hose to the drain port in place of a drain plug. 3) Shape the refrigerant pipe along the pipe path marking on the mounting plate. 4) Pass drain hose and refrigerant pipes through the wall hole, then set the indoor unit on mounting plate hooks, using the markings at the top of indoor unit as a guide. 5) Pull in the interconnecting wires. 6) Connect the inter-unit piping. Drain hose Caulk this hole with putty or caulking material. 7) Wrap the refrigerant pipes and drain hose together with insulation tape as right figure, in case of setting the drain hose through the back of the indoor unit. 8) While exercising care so that the interconnecting wires do not catch indoor unit, press the bottom edge of indoor unit with both hands until it is firmly caught by the mounting plate hooks. Secure indoor unit to the mounting plate with screws (M4 12L). Remove pipe port cover here for left-bottom piping. How to set drain plug. No gap. Bind with plastic tape. A Mounting plate Left-bottom piping Do not apply lubricating oil (refrigeration oil) when inserting. Application of causes deterioration and drain leakage of the plug. Insert a hexagon wrench (4mm). Left-side piping Left-back piping Wrap insulating tape around the bent portion of refrigerant pipe. Overlap at least half the width of the tape with each turn. Inter-unit wiring Drain hose A Mounting plate Refrigerant pipes 3-3. Wall embedded piping. Follow the instructions given under Left-side, left-back, or left-bottom piping 1) Insert the drain hose to this depth so it won t be pulled out of the drain pipe. Bottom frame Insert drain hose to this depth so it won t be pulled out of drain pipe. 50mm or more Outer wall H M4 12L (2 point) Inner wall Drain hose Vinyl chloride drain pipe (VP-30) 9 English

4. Wiring. 1) Strip wire ends (15mm). 2) Match wire colours with terminal numbers on indoor and outdoor unit s terminal blocks and firmly screw wires to the corresponding terminals. 3) Connect the earth wires to the corresponding terminals. 4) Pull wires to make sure that they are securely latched up, then retain wires with wire retainer. 5) In case of connecting to an adapter system. Run the remote controller cable and attach the S21. 6) Shape the wires so that the service lid fits securely, then close service lid. English 1 2 3 Use the specified wire type. Terminal block Electrical component box Shape wires so that the service lid will fit securely. Firmly secure wire retainer so that wires sustain no external stress. Wire retainer When wire length exceeds 10m, use 2.0mm diameter wires. Indoor unit 1 2 3 Firmly fix the wires with the terminal screws. Firmly fix the wires with the terminal screws. Outdoor unit 123 LN H05RN WARNING 1) Do not use tapped wires, strand wires, extensioncords, or starburst connections, as they may cause overheating, electrical shock, or fire. 2) Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc., from the terminal block.) Doing so may cause electric shock or fire. 5. Drain piping. 1) Connect the drain hose, as described right. The drain hose should be inclined downward. No trap is permitted. Do not put the end of the hose in water. 3) Remove the air filters and pour some water into the drain pan to check the water flows smoothly. 4) When drain hose requires extension, obtain an extension hose commercially available. Be sure to thermally insulate the indoor section of the extension hose. Indoor unit drain hose φ18 Extension drain hose Heat insulation tube (Field supply) 5) When connecting a rigid polyvinyl chloride pipe (nominal diameter 13mm) directly to the drain hose attached to the indoor unit as with embedded piping work, use any commercially available drain socket (nominal diameter 13mm) as a joint. φ18 Drain hose supplied with the indoor unit Commercially available drain socket (nominal diameter 13mm) Commercially available rigid polyvinyl chloride pipe (nominal diameter 13mm) English 10

Refrigerant Piping Work 1. Flaring the pipe end. 1) Cut the pipe end with a pipe cutter. 2) Remove burrs with the cut surface facing downward so that the chips do not enter the pipe. 3) Put the flare nut on the pipe. 4) Flare the pipe. 5) Check that the flaring is properly made. (Cut exactly at right angles.) Remove burrs Flaring Set exactly at the position shown below. A Flare tool for R410A Conventional flare tool Clutch-type Clutch-type (Rigid-type) Wing-nut type (Imperial-type) Die A 0-0.5mm 1.0-1.5mm 1.5-2.0mm Flare s inner surface must be flaw-free. Check The pipe end must be evenly flared in a perfect circle. Make sure that the flare nut is fitted. WARNING 1) Do not use mineral oil on flared part. 2) Prevent mineral oil from getting into the system as this would reduce the lifetime of the units. 3) Never use piping which has been used for previous installations. Only use parts which are delivered with the unit. 4) Do never install a drier to this R410A unit in order to guarantee its lifetime. 5) The drying material may dissolve and damage the system. 6) Incomplete flaring may cause refrigerant gas leakage. 2. Refrigerant piping. CAUTION 1) Use the flare nut fixed to the main unit. (To prevent cracking of the flare nut by aged deterioration.) 2) To prevent gas leakage, apply refrigeration oil only to the inner surface of the flare. (Use refrigeration oil for R410A.) 3) Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leakage. Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand. Then tighten them fully with the torque wrenches. [Apply oil] [Tighten] Do not apply refrigeration oil to the outer surface. Apply refrigeration oil to the inner surface of the flare. Torque wrench Flare nut Spanner Piping union Do not apply refrigeration oil to the flare nut avoid tightening with over torque. Flare nut Flare nut tightening torque Gas side 20/25 class 35 class 3/8 inch 1/2 inch 32.7-39.9N l m 49.5-60.3N l m (330-407kgf l cm) (505-615kgf l cm) Liquid side 1/4 inch 14.2-17.2N l m (144-175kgf l cm) 11 English

2-1. Caution on piping handling. 1) Protect the open end of the pipe against dust and moisture. 2) All pipe bends should be as gentle as possible. Use a pipe bender for bending. 2-2. Selection of copper and heat insulation materials. When using commercial copper pipes and fittings, observe the following: 1) Insulation material: Polyethylene foam Heat transfer rate: 0.041 to 0.052W/mK (0.035 to 0.045 kcal/(mh C)) Refrigerant gas pipe s surface temperature reaches 110 C max. Choose heat insulation materials that will withstand this temperature. Rain If no flare cap is available, cover the flare mouth with tape to keep dirt or water out. Gas pipe Be sure to place a cap. Inter-unit wiring Wall Liquid pipe English 2) Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below. Gas side Gas pipe thermal insulation Liquid pipe Liquid side 20/25 class 35 class 20/25 class 35 class thermal insulation O.D. 9.5mm O.D. 12.7mm O.D. 6.4mm I.D. 12-15mm I.D. 14-16mm I.D. 8-10mm Minimum bend radius 30mm or more 40mm or more 30mm or more Thickness 10mm Min. Thickness 0.8mm (C1220T-O) 3) Use separate thermal insulation pipes for gas and liquid refrigerant pipes. Pump Down Operation In order to protect the environment, be sure to pump down when relocating or disposing of the unit. 1) Remove the valve cap from liquid stop valve and gas stop valve. 2) Carry out forced cooling operation. 3) After five to ten minutes, close the liquid stop valve with a hexagonal wrench. 4) After two to three minutes, close the gas stop valve and stop forced cooling operation. Gas pipe insulation Liquid stop valve Finishing tape Liquid pipe insulation Drain hose Hexagonal wrench Close How to force cooling operation mode Using the indoor unit operation/stop button Press the indoor unit operation/stop button for at least five seconds. (Operation will start.) Forced cooling operation will stop automatically after around 15 minutes. To force a test run to stop, press the indoor unit operation/stop button. Gas stop valve Valve cap Using the main unit s remote controller 1) Press the operation/stop button. (Operation will start.) 2) Press the temperature button and the operation select button at the same time. 3) Press the operation select button twice. ( will be displayed and the unit will enter test run mode.) 4) Press the operation select button to return the operation mode to cooling. Test run mode will stop automatically after around 30 minutes. To force a test run to stop, press the operation/stop button. CAUTION 1) After closing the liquid stop valve, close the gas stop valve within three minutes, then stop the forced operation. English 12

Trial Operation and Testing 1. Trial operation and testing. 1-1 Measure the supply voltage and make sure that it falls in the specified range. 1-2 Trial operation should be carried out in either cooling or heating mode. In cooling mode, select the lowest programmable temperature; in heating mode, select the highest programmable temperature. 1) Trial operation may be disabled in either mode depending on the room temperature. Use the remote controller for trial operation as described below. 2) After trial operation is complete, set the temperature to a normal level (26 C to 28 C in cooling mode, 20 C to 24 C in heating mode). 3) For protection, the system disables restart operation for 3 minutes after it is turned off. 1-3 Carry out the test operation in accordance with the Operation Manual to ensure that all functions and parts, such as louver movement, are working properly. The air conditioner requires a small amount of power in its standby mode. If the system is not to be used for some time after installation, shut off the circuit breaker to eliminate unnecessary power consumption. If the circuit breaker trips to shut off the power to the air conditioner, the system will restore the original operation mode when the circuit breaker is opened again. Trial operation from remote controller 1) Press ON/OFF button to turn on the system. 2) Press TEMP (2 locations) and MODE at the same time. 3) Press MODE selector button twice. ( will appear on the display to indicate that Trial Operation mode is selected.) 4) Trial run mode terminates in approx. 30 minutes and switches into normal mode. To quit a trial operation, press ON/OFF button. 2. Test items. Test items Indoor and outdoor units are installed properly on solid bases. No refrigerant gas leaks. Refrigerant gas and liquid pipes and indoor drain hose extension are thermally insulated. Draining line is properly installed. System is properly earthed. The specified wires are used for interconnecting wire connections. Indoor or outdoor unit s air intake or exhaust has clear path of air. Stop valves are opened. Indoor unit properly receives remote controller commands. will appear when the MODE selector button is pressed.* * If the is not displayed, change the dipswitch setting for the remote controller. Slide the dipswitch to the left-hand side. Press the MODE selector button again and check that appears on the LCD of the remote controller. Symptom (diagnostic display on RC) Fall, vibration, noise Incomplete cooling/heating function Water leakage Water leakage Electrical leakage Inoperative or burn damage Incomplete cooling/heating function Inoperative No heating Check Dipswitch 13 English

3P232538-1 M08B045 Two-dimensional bar code is a code for manufacturing. (0809) HT