Ciclu de funcționare pompă de caldură:

Similar documents
History List. Version Date Update Information New EHS SPLIT TDB Released. (Modify the Spec Note)

Samsung System Air Conditioner Eco Heating System

EHS. EHS (Mono, LT, 50Hz)

PAC (FLOOR STANDING) 2016 Samsung

Samsung System Air Conditioner Eco Heating System

SINGLE. Technical Data Book. PAC for Europe (R410A, 50Hz, HP) Model : AC***KNPDEH/EU AC***KXAD*H/EU

Samsung EHS, XL Range of Commercial Air to water heat pumps

Monobloc. Distributed by. Copyright 2018 LG Electronics. All rights reserved.

Cold Remedies. SamsungHVAC.com. Product Registration Required Conditions Apply

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

Learn more about Samsung air conditioner at:

A single answer for multiple zones.

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

A single answer for multiple zones.

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F)

Submitted to Reference Approval Construction Unit Designation Schedule #

Submitted to Reference Approval Construction Unit Designation Schedule #

LG Electronics AE Company, Commercial Air Conditioning

Samsung Eco Heating System

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01J (Replace: 5BPM0-01H)

NATURAL HEATING MACHINE

HOTTY. POMPE DE CALDURA AER APA PENTRU EXTERIOR Temperaturi inalte - Eficienta ridicata

Samsung Air Conditioning CASSETTE SPLIT SYSTEM AIR CONDITIONING. Samsung Air Conditioning 1

Advance Split

Well rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting.

SINGLE Technical Data Book SINGLE Duct S for America (R410A, HP)

LG Electronics AE Company, Commercial Air Conditioning

PAC BT LOW TEMPERATURE HEAT PUMP

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

Increase your flexibility.

Technical data LA 60TUR+

CHILLER Technical Data Book DVM CHILLER for Europe (R410A, 50/60Hz, HP)

Product Line Introduction. Karl Zhang Technical support engineer

SAC Technical Data Book

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

Do you want a versatile solution

American Brand with Global Reach. Heat Pump Decorative Wall Mount Split Unit

LG HVAC SOLUTION. LG Electronics Distributed by. Copyright 2016 LG Electronics. All rights reserved.

SDU A. SDU A Loops. (available in 3, 4, 5 loops) Water Based Systems. Standard Distribution Unit assembled with: A Blank Port (capped)

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule #

Our. What is LG THERMA V? ENERGY EFFICIENT APPLICATION VARIOUS APPLICATION

Multi Inverter Air Conditioning Condensing Units - Summary

AIR CONDITIONERS SPLIT TROPICAL RANGE. FLAT SPLIT - Heat & Cool T1 R410a AMD K BTU EAN: AMD K BTU EAN:

BWL air heat pumps BWS brine heat pumps

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

ROOF TOP TYPE UNITS CENTRIFUGAL FANS ENGINEERING DATA MANUAL MODELS Rev. 100

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

13 SEER CONDENSING UNITS & AIR HANDLERS

HEAT PUMPS. Efficient Comfort For Every Season

w Outdoor Unit w Hydro Indoor Unit w Hot Water Tank *** Projected Availability Q ***

Samsung 360 Cassette, Single Zone, Split System

50A KP 70A KP 90A KP 120A KP 150A KP 210A

HEATING HEA TING

Technical Manual. Multi Split Trio Quattro DCI REFRIGERANT R410A HEAT PUMP

DVM S Universal Communication Kit (UCK) Design Guide

Air-water heat pump. Hydronic terminals. HYDROLution NEW 172 SINGLE HT 176 DUAL HT 178 MINI CHILLER 180 MODULAR CHILLER 182 WARM COIL 184 FAN COIL 186

4. VRF - Digital Variable Multi (DVM) 226. Introduction Residential - Room Air Conditioner (RAC) Multi Split - Free Joint Multi (FJM) 56

VRF Outdoor Units. YMGI Group 601 Arrow Ln, O Fallon, MO ymgigroup.com Solar Series Mini & Modular

SMC DUCTED. High Performance AIR CONDITIONING SYSTEMS

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

AirtoWaterHeat Pump -TDM PLUS Hydro Unit

Technical data LA 9S-TU

5/10/16Hp (HE) 5/8Hp (HT) MODEL : AM160FNBFEB/EU, AM160FNBFGB/EU, AM250FNBFEB/EU, AM250FNBFGB/EU AM160FNBDEH/EU, AM320FNBDEH/EU, AM500FNBDEH/EU

Samsung Free Joint Multi Air Conditioning System

High efficiency air to water Heat pumps LZT series

Technical data LA 28TBS

THE WORLD S MOST EFFICIENT HEAT PUMP

Geniuses at work. Residential Mini Splits

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

Samsung Air Conditioning

Air Conditioning System

GOODBYE SQUARE AIR SAMSUNG AIR CONDITIONING. VRF SPECIFIERS DESIGN GUIDE 4 th EDITION

UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

2008 SAMSUNG SYSTEM AIR CONDITIONERS Version.2

LG VRF Systems. Air Conditioning Technologies

Hitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

LG AIR CONDITIONERS 2013 Ducted Split System

Mini Splits Catalog SINGLE ZONE

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

DC INVERTER MULTI-SYSTEM AIR CONDITIONER


VRF Technical Data Book. Wind-Free 4Way Cassette for America (Low Ambient, R410A, HP)

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

TECHNICAL DATA & SERVICE MANUAL

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

AIRLINE - commercial heat pumps Air / water heat pump for heating, cooling and DHW production - commercial use

HIWARM kw. Air-water system with external and internal BLDC unit. Total heat recovery multi-purpose units HIWARM PLUS

Advance Product Data

VIESMANN. VITOCAL Air/water heat pumps. Technical guide. VITOCAL 300-A Type AWC-I and AW-O. VITOCAL 350-A Type AWH-I and AWH-O

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Wall Split System Air Conditioning

HEAT PUMPS LINE AS AIR TO WATER

PUHZ-SHW140YHA PUHZ-SHW230YKA

Transcription:

Ce este o pompă de căldură? Definiție tehnică: Pompa de căldură este un dispozitiv cu ajutorul căruia se poate transporta căldură de la o locație ("sursă") la o altă locație ("schimbător de căldură") folosind lucru mecanic, de obicei în sens invers direcției naturale de mișcare a căldurii. Majoritatea pompelor de căldură sunt folosite pentru a muta / extrage căldura de la o sursă cu temperatură mai mică la un mediu cu temperatură mai mare. Altfel spus, o pompă de căldură reprezintă un sistem de înaltă eficiență (clasificat cf U.E. în categoria produselor de energie regenerabilă ecologice, eficiente) pentru încălzirea (răcirea) casei și producere apa caldă menajeră De fapt, pentru fiecare kwh de energie primară absorit, o pompă de căldură poate oferi mai mult de 4 kwh de energie utilă cu un coeficient de performanță COP mai mare de 400% în schimb performanța unui sistem de încălzire de buna calitate poate atinge 95%. oate acestea înseamnă că, spre deosebire de pompa de căldură, sistemele de încălzire consumă mai mult energie decât energia pe care o oferă sub formă de căldură.

Ciclu de funcționare pompă de caldură: - Vaporizator: schimbator de caldura freon/apa (freonul cedeaza caldura apei), Compresor, Condensator, Vana de laminare (expansiune), Vana cu 4 cai = inverseaza ciclul frigorific

COP / EER COP (Coefficient Of Performance) Exprimă eficiența pompei de caldură în modul de încălzire COP = Puterea termică furnizată pe încălzire (W) / Puterea electrică pt încalzire (consumată) (W) EER (Energy Efficiency Ratio) Exprimă eficiența pompei de caldură în modul de răcire EER = Puterea de răcire furnizată(w) / Puterea electrică pentru răcire (consumată) (W) Exemplu: O pompă de căldură cu un COP de 4,13 furnizează 4,13 unitatăți de căldură pentru fiecare unitate de energie electrică ce a fost consumată (adică 1 kw electric consumat furnizează 4,13 Kw energie termică).

Pompe de căldură aer-apă Hydro unit Apa rece Apa calda Monoblock 1. O singura unitate (externa) 2. Inauntru se duce agent termic => instalare facila (instalator termist ) 3. Pericol de inghet, obligatoriu antigel in instalatie!! Ref. pipe Apa calda Apa rece Split 1. Doua unitati (U.E + U.I / hidrokit) 2. Inautru se duce freon, legatura intre U.E si hidrokit = tevi refrigerant=> instalator specialist frigotehnica 3. Fara pericol de inghet, partea hidraulica este in interior

Unde se folosesc? În aplicații variate de încălzire (producere ACM boiler special) / racire pt locuințe sau clădiri rezidențiale / de birouri etc., având sisteme de încălzire cu temperatură joasă (încălzire în pardoseală și/sau ventiloconvectoare, chiar si radiatoare). - Unde nu există posibilitatea de racordare le rețeaua de gaz metan - Unde se dorește eficiență energetică, folosirea energiei regenerabile, randament, confort crescut. - Unde este buget LIMIE DE FUNCȚIONARE Plaja larga: temperaturi exterioare de la -20 C (-25 C) la +43 C (46 C) Încălzire emperatură apă 25 55 C emperatură aer ext. -20/25 35 C Răcire emperatură apă 7 25 C emperatură aer ext. 10 46 C

Țevi apă Solar Panel Țevi freon Hydro Unit ACM ank Remote Controller hermostat cameră Unitate ext Warm and Safe Water Încăzlire în pardoseală & Radiator

Eficiență 6.0 ( EHS SPLI ) 5.5 A+++ A+++ A+++ A+++ A+++ A+++ 5.0 4.5 4.0 18.0 Nominal 15.0 90% 12.0 12.0 13.2 14.4 15.2 16.2 16.7 16.0 3.5 3.0 4 6 9 12 14 16 (kw) 6.0 (EHS MONO ) 9.0 6.0-25 -20-15 -10-5 0 5 10 5.5 5.0 A+++ A+++ A+++ A+++ A+++ la temperaturi cuprinse intre -25 C ~ -20 C, functionarea este posibila capacitatea nu este garantata. 4.5 4.0 3.5 3.0 5 9 12 14 16 (kw)

Caracteristici

Caracteristici

Caracteristici

WI-FI kit - opțional Control AC Anywhere, Anytime (Optional) - Since You Can Control Your Air Conditioner with Your Smart Phone, You Can Easily urn It Off from Outside the House - Can Connect Optional Wi-Fi Kit

Nomenclature EHS unit Model Name AE 160 M X P G H EU (1) (2) (3) (4) (5) (6) (7) (8) (Buyer) / (1) Classification AE EHS (2) Capacity (3Digit) W x 100 A Y L M J (5) Feature 1 (EHS Indoor unit) RAC-A3050 Hydro unit LSP duct MSP duct Console (7) Voltage A A(115V, 60hz, 1Ф) B B(220V, 60Hz, 1Ф) C C(208~230V, 60Hz) D D(200~220V, 50Hz) E E(220~240V, 50Hz) (3) Year H 2014 J 2015 K 2016 M 2017 E Y (5) Feature 1 (EHS Outdoor unit) SINGLE MULI MONO F F(208~230V, 60Hz, 3Ф) G G(380~415V, 50Hz, 3Ф) H H(380V, 60Hz, 3Ф) Saudi 400V J J(460V, 60Hz, 3Ф) K K(220~240V, 50/60Hz, 1Ф) M M(127V, 50Hz) S N X A B C (4) In / Out Set (New protocol) Indoor unit (New protocol) Outdoor unit (New protocol) Set (Old protocol) Indoor unit (Old protocol) Outdoor unit (Old protocol) D P (6) Feature 2 DELUXE (Basic) MULI (Premium) N N (380~415V, 50/60Hz, 3Ф) (8) Mode C Cooling only H Heat Pump R410A R Heat Recovery D Cooling only R22 E Heat Pump A Cooling only R134A B Heat Pump N N/A

Pompe de caldură aer-apă MODEL Monobloc Unitate Externa Unitate Interna (Hydrokit) Controller Incalzire kw Racire kw COP EER AE050JXYDEH/EU - MIM-E03BN 5 5 4,72 4,13 AE090JXYDEH/EU - 9 7,5 4,21 3,85 AE120JXYDEH/EU - 12 12 4,51 3,8 MIM-E03AN AE140JXYDEH/EU - 14 13 4,46 3,71 AE160JXYDEH/EU - 16 14 4,21 3,65 Obs: fara pompa de circulatie si rezistenta electrica Split 4-16 kw AE040JXEDEH/EU - 4 5 5,1 3,97 AE060JXEDEH/EU AE090JNYDEH/EU - 6 6,5 4,8 3,71 AE090JXEDEH/EU - 9 8 4,48 3,64 AE120JXEDEH/EU - 12 12 4,63 3,87 AE140JXEDEH/EU AE160JNYDEH/EU - 14 14 4,44 3,68 AE160JXEDEH/EU - 16 15 4,26 3,62 Obs: includ pompa de circulatie si rezistenta electrica Split 18-45 Kw (bazat pe DVM) AM060FXMDGH 18 15,5 4,1 3,6 AM080FXMDGH 25 22,4 5,12 3,92 AM320FNBDEH/EU AM100KXMDGH MWR-WW00N 31,5 27,99 5,12 3,92 AM120KXMDGH 37,5 33,5 4,68 3,84 AM140KXMDGH AM500FNBDEH/EU 45 40 4,79 3,82 Obs: fara pompa de circulatie si rezistenta electrica

Power Source kw Residential Solution Commercial Solution EHS SPLI EHS MONO EHS DM plus DVM HE DVM H Picture OUDOOR UNI DVM OUDOOR DVM EHS HYDRO RS 2015 2015 2017 New 4.0~5.0 AE040JXEDEH AE050JXYDEH AE044MXPEH/EU 6.0 AE060JXEDEH AE066MXPEH/EU 7.0 8.0 1P, 220-240V 9.0 50Hz 11.0 AE090JXEDEH AE090JXYDEH AE090MXPEH/EU 12.0 AE120JXEDEH AE120JXYDEH AE120MXPEH/EU 14.0 AE140JXEDEH AE140JXYDEH 16.0 AE160JXEDEH AE160JXYDEH AE160MXPEH/EU 3P, 380-415V 50Hz 3P, 380-415V 50Hz 1P, 220-240V 50Hz 3P, 380-415V 50Hz 9.0 AE090JXEDGH AE090JXYDGH AE090MXPGH/EU 12.0 AE120JXEDGH AE120JXYDGH AE120MXPGH/EU 14.0 AE140JXEDGH AE140JXYDGH 16.0 AE160JXEDGH AE160JXYDGH AE160MXPGH/EU - DVM S series DVM S series 9.0 AE090JNYDEH AE090MNYDEH/EU 16.0 AE160JNYDEH AE160MNYDEH/EU AM160FNBDEH AM160FNBFEB 32.0 AM320FNBDEH AM250FNBFEB 50.0 AM500FNBDEH 9.0 AE090JNYDGH AE090MNYDGH/EU AM160FNBFGB 16.0 AE160JNYDGH AE160MNYDGH/EU AM250FNBFGB

16/100 his Document can not be used without Samsung's authorization Ce este EHS (Mono)? Control kit (Obligatoriu) Apa rece Apa calda Boiler Panou solar Vana 2, 3 cai hermostat Alt echipament

17/100 his Document can not be used without Samsung's authorization Ce este EHS (Mono)? E Solar Pump Solar thermal Panel 1) Solar Control Booster Heater & Protector hermistor 50~55 45 Room Controller 4) Zone Control Supply Header Return Header Radiators or Convectors Control kit DHW ank Load Pump #1 [Application #2] hermostatic & Balancing Valves [Application #3] Room hermostat & Actuators 3 4 Load E Pump #2 2 40 B Supply Header Outdoor unit Control kit 3) DHW Control Mixing ank 4) Mixing Valve E [Application #1] Zone hermostat & 2-way Valve Return Header Under-Floor Heating Coils [Application #4] Differential Pressure bypass valve

Model Name AE050****E*** AE090****E*** AE120****E*** AE140****E*** AE160****E*** AE090****G*** AE120****G*** AE140****G*** AE160****G*** Capacity (A7W35) kw 5 9 12 14 16 9 12 14 16 COP W/W 4.50 4.20 4.51 4.46 4.21 4.20 4.51 4.46 4.21 EER W/W 4.00 3.64 3.80 3.70 3.65 3.64 3.80 3.70 3.65 Energy Grade - A ++ Water Pipe In Φ, inch BSPP male 1" Water Pipe Out Φ, inch BSPP male 1" Leaving Water emp. Heat C 25~55 Cool C 5~25 Power Supply - E (220~240V, 50Hz, 1Ф) G (380~415V, 60Hz, 3Ф) Compressor - UG4200 UG8300 UG5450 UG5450 UG5450 UG8300 UG5450 UG5450 UG5450 Base Plate Heater W - 150 150 150 150 150 150 150 150 Noise Heat db(a) 48 49 50 51 52 49 50 51 52 Dimension mm 880 x 798 x 310 940 x 998 x 330 940 x 1,420 x 330 940 x 998 x 330 940 x 1,420 x 330 Heat -25 ~ 35 Operating emp. Cool 10 ~ 46 DHW -25 ~ 43

20/100 his Document can not be used without Samsung's authorization Ce este EHS (Split)? evi freon Hydro unit Boiler Panou solar Vana 2, 3 cai hermostat Apa rece Apa calda Alt echipament

21/100 his Document can not be used without Samsung's authorization Ce este EHS (Split)? E Solar Pump Solar thermal Panel 1) Solar Control Booster Heater & Protector hermistor 50~55 45 Room Controller 4) Zone Control Supply Header Return Header Radiators or Convectors DHW ank Load Pump #1 [Application #2] hermostatic & Balancing Valves [Application #3] Room hermostat & Actuators 3 4 Load E Pump #2 2 40 B Supply Header Outdoor unit Hydro-unit 3) DHW Control Mixing ank 4) Mixing Valve E [Application #1] Zone hermostat & 2-way Valve Return Header Under-Floor Heating Coils [Application #4] Differential Pressure bypass valve

Hydro Unit AE060JNYDEH AE060JNYDEH AE090JNYDEH AE160JNYDEH AE160JNYDEH AE160JNYDEH AE090JNYDGH AE160JNYDGH AE160JNYDGH AE160JNYDGH Outdoor Unit AE040JXEDEH AE060JXEDEH AE090JXEDEH AE120JXEDEH AE140JXEDEH AE160JXEDEH AE090JXEDGH AE120JXEDGH AE140JXEDGH AE160JXEDGH Capacity (A7W35) W 4,400 6,000 9,000 12,000 14,000 16,000 9,000 12,000 14,000 16,000 COP W/W 5.10 4.80 4.48 4.63 4.44 4.26 4.48 4.63 4.44 4.26 EER W/W 3.80 3.70 3.64 3.87 3.68 3.62 3.64 3.87 3.68 3.62 Energy Grade - A ++ Power Supply - E (220~240V, 50Hz, 1Ф) G (380~415V, 60Hz, 3Ф) Water Pump - Flow Switch LPM 7.5 ± 1.5 12 ± 1.5 12 ± 1.5 16 ± 1.5 16 ± 1.5 16 ± 1.5 12 ± 1.5 16 ± 1.5 16 ± 1.5 16 ± 1.5 Backup Heater W 4,000 4,000 4,000 6,000 6,000 6,000 6,000 6,000 6,000 6,000 Expansion Vessel bar 8 8 8 8 8 8 8 8 8 8 Relief Valve bar 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 Air Purge Valve - Compressor - UG4H8200 UG4H8200 UG8300 UG5450 UG5450 UG5450 UG8300 UG5450 UG5450 UG5450 Dimension (Hydro) mm 510 x 850 x 315 Base Plate Heater W - - 150 150 150 150 150 150 150 150 Noise Heat db(a) 46 47 49 50 50 52 49 50 50 52 Dimension (ODU) mm 880 x 638 x 310 940 x 998 x 330 940 x 1,420 x 330 940 x 998 x 330 940 x 1,420 x 330 Heat -25 ~ 35 Operating emp. Cool 10 ~ 46 DHW -25 ~ 43

25/100 his Document can not be used without Samsung's authorization Ce este EHS (DM)? [# Unitati interne A2A compatibile] Unitati interne Aer Aer Hydro unit Boiler Panou solar evi freon Vana 2, 3 cai Apa rece Apa calda hermostat Alt echipament

26/100 his Document can not be used without Samsung's authorization Ce este EHS (DM)? E Solar thermal Panel Indoor unit 5) Air to Air Control Solar Pump 1) Solar Control Booster Heater & Protector hermistor 50~55 45 Room Controller 4) Zone Control Supply Header Return Header Radiators or Convectors DHW ank Load Pump #1 [Application #2] hermostatic & Balancing Valves [Application #3] Room hermostat & Actuators 3 4 Load E Pump #2 2 40 B Supply Header Outdoor unit Hydro-unit 3) DHW Control Mixing ank 4) Mixing Valve E [Application #1] Zone hermostat & 2-way Valve Return Header Under-Floor Heating Coils [Application #4] Differential Pressure bypass valve

Concept System Configuration EHS DM plus Unitate externa Hydro Unit Sistem incălzire liquid Apă caldă (max 55 ) FREON R410A Gas Water Piping Floor Heating Radiator EEV kit Boiler Hot Water Outdoor Indoor 27/47 his Document can not be used without Samsung's authorization

DM plus Concept Încălzire rapidă prin tehnologia DM On heating Off heating Off On On 28/47 his Document can not be used without Samsung's authorization

DM plus - gama In/Outdoor compatibility : DM PLUS (NASA) Capacity (kw) 4.4 6.6 9.0 12.0 16.0 DM (NASA) NEW NEW NEW NEW NEW 1Φ, 220~240V HP 0 0 NEW NEW NEW 3Φ, 380~415V HP Capacity (kw) 2.2 2.8 3.6 5.6 7.1 9.0 16.0 1ph NEW NEW Hydro Unit 3ph NEW NEW Wall Mount Duct A3050 Good1 *Without EEV Slim Duct MSP Duct (Duct S) 0 0 0 0 0 0 - Console 0 0 0 0 29/47 his Document can not be used without Samsung's authorization

DM plus Model Name AE044MXPEH/EU AE066MXPEH/EU AE090MXPEH/EU AE090MXPGH/EU AE120MXPEH/EU AE120MXPGH/EU AE160MXPEH/EU AE160MXPGH/EU Mode - Heat Pump (A2W) Heat Pump (A2W) Heat Pump (A2W) Heat Pump (A2W) Heat Pump (A2W) Heat Pump (A2W) Heat Pump (A2W) Heat Pump (A2W) Capacity Heating W 4,400 6,600 9,000 9,000 12,000 12,000 16,000 16,000 Btu/h 15,000 22,500 30,700 30,700 40,900 40,900 54,600 54,600 Cooling W 5,100 6,700 8,000 8,000 12,000 12,000 14,500 14,500 Btu/h 17,400 22,900 27,300 27,300 40,900 40,900 49,500 49,500 A2W Heating 930 1,470 2,120 2,120 2,720 2,720 3,950 3,950 Condition #1. Power Input W (A7/W35) *1 Cooling 1,030 1,480 1,850 1,860 2,900 2,900 3,840 3,840 Current Input Heating 4.3 6.7 9.6 3.5 12.4 4.3 18.0 6.0 A Cooling 4.9 6.9 8.5 3.0 13.2 4.5 17.5 5.9 COP (Heating) W/W 4.73 4.49 4.25 4.25 4.41 4.41 4.05 4.05 EER (Cooling) W/W 4.95 4.53 4.32 4.30 4.14 4.14 3.78 3.78 A2/W35 *3 Capacity Heating W 4,000 5,800 7,700 7,700 11,000 11,000 13,700 13,700 COP W/W 3.54 3.31 3.47 3.47 3.41 3.41 3.19 3.19 A-7/W35 *3 Capacity Heating W 3,900 5,700 7,400 7,400 10,600 10,600 14,000 14,000 COP W/W 2.81 2.79 2.79 2.79 2.97 2.97 2.73 2.73 System Outdoor Unit Field Wiring Water Connections Refrigerant MCA A 18.0 20.0 22.0 10.0 28.0 10.0 32.0 12.0 MFA A 25.0 25.0 27.5 16.1 35.0 16.1 40.0 16.1 Communication Min. m2 - - - - - - - - Water Flow Rate Min/Std/Max LPM 7.0/12.7/42.0 7.0/19.0/42.0 7.0/26.0/42.0 7.0/26.0/42.0 12.0/34.6/58.0 12.0/34.6/58.0 12.0/46.2/58.0 12.0/46.2/58.0 Piping Connections Piping length (ODU-IDU) Level difference (IDU-IDU) Liquid pipe Φ, mm (inch) 9.52 (3/8) 9.52 (3/8) 9.52 (3/8) 9.52 (3/8) 9.52 (3/8) 9.52 (3/8) 9.52 (3/8) 9.52 (3/8) Gas pipe(a2w) Φ, mm (inch) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) Gas pipe(a2a) Φ, mm (inch) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) Max.[Equiv.] m 30 30 30 30 70 70 70 70 Max. m 20 20 20 20 30 30 30 30 Chargeless Length m 10 10 10 10 10 10 10 10 ype - R410A R410A R410A R410A R410A R410A R410A R410A Factory Charging kg 2.6 2.6 2.4 2.4 3.5 3.5 3.5 3.5 tco2e 5.43 5.43 5.01 5.01 7.31 7.31 7.31 7.31 Control Method - EEV EEV EEV EEV EEV EEV EEV EEV Power Supply Φ, #, V, Hz 1,2,220-240,50 1,2,220-240,50 1,2,220-240,50 3,4,380-415,50 1,2,220-240,50 3,4,380-415,50 1,2,220-240,50 3,4,380-415,50 Compressor ype - Rotary Comp Rotary Comp Rotary Comp Rotary Comp Rotary Comp Rotary Comp Rotary Comp Rotary Comp Output kw n Model Name - UG4H8200FE4 UG4H8200FE4 UG8H8265FJW UG8300FUCJU UG5K1450FJX UG5K1450FJX UG5K1450FJX UG5K1450FJX Oil ype - POE POE POE PVE PVE PVE PVE PVE Initial Charge cc 650 650 700 1,200 1,700 1,700 1,700 1,700 ype - Propeller Fan Propeller Fan Propeller Fan Propeller Fan Propeller Fan Propeller Fan Propeller Fan Propeller Fan Fan Discharge direction Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Air Flow Rate m³/min 45 47 67 67 103 103 123 123 Quantity EA 1 1 1 1 2 2 2 2 Base Heater W - - - - - - - - Heating db(a) 47 48 51 51 52 52 55 55 Sound Pressure Sound Cooling db(a) 46 47 50 50 51 51 54 54 Sound Power db(a) 65 67 69 69 70 70 73 73 External Dimension Operating emp. Range Net Weight kg 61 61 74 76 107 107 107 107 Shipping Weight kg 64.5 64.5 82 84 115 115 115 115 Net Dimensions (WxHxD) mm 880 x 793 x 310 880 x 793 x 310 940 x 998 x 330 940 x 998 x 330 940 x 1,420 x 330 940 x 1,420 x 330 940 x 1,420 x 330 940 x 1,420 x 330 Shipping Dimensions (WxHxD) mm 1,023 x 911 x 413 1,023 x 911 x 413 995 x 1,178 x 426 995 x 1,178 x 426 995 x 1,598 x 426 995 x 1,598 x 426 995 x 1,598 x 426 995 x 1,598 x 426 Heating -25~35-25~35-25~35-25~35-25~35-25~35-25~35-25~35 A2W Cooling 10~46 10~46 10~46 10~46 10~46 10~46 10~46 10~46 D.Hot Water -25~43-25~43-25~43-25~43-25~43-25~43-25~43-25~43 A2A Heating -25~24-25~24-25~24-25~24-25~24-25~24-25~24-25~24 Cooling 10~46 10~46 10~46 10~46 10~46 10~46 10~46 10~46

Încărcare supliementară cu refrigerant Mono Split DM Outdoor unit Liquid Pipe [mm] [ SPLI ] Gas Pipe [mm] Factory charge [kg] AE040****EH ø6.35 ø15.88 1.4 AE060****EH ø6.35 ø15.88 1.4 AE090****EH ø6.35 ø15.88 1.7 AE120****EH ø9.52 ø15.88 2.98 AE140****EH ø9.52 ø15.88 2.98 AE160****EH ø9.52 ø15.88 2.98 AE090****GH ø6.35 ø15.88 1.9 AE120****GH ø9.52 ø15.88 2.98 AE140****GH ø9.52 ø15.88 2.98 AE160****GH ø9.52 ø15.88 2.98 Outdoor unit Liquid Pipe [mm] [ DM PLUS ] Gas Pipe(Air) [mm] Gas Pipe(Water) [mm] Factory charge [kg] AE044****EH Ø9.52 ø15.88 ø15.88 2.6 AE066****EH Ø9.52 ø15.88 ø15.88 2.6 AE090*****H Ø9.52 ø15.88 ø15.88 2.4 AE120*****H Ø9.52 ø15.88 ø15.88 3.5 AE160*****H Ø9.52 ø15.88 ø15.88 3.5 Air to Water Additional Charge(g) = (L1 x 20) + (L2 x 50) Air to Air Additional Charge(g) = (L1 x 20) + (L2 x 50) + Additional charge by A2A indoor unit Additional Additional Charge[g] = Charge[g] = ( L-15) 20 ( L-15) 50 L1 = otal length of liquid pipe of Ø 6.35 (mm) L2 = otal length of liquid pipe of Ø 9.52 (mm)