T a b l e o f C o n t e n t s

Similar documents
Tri-Tech Medical Inc.

Med Touch Combination Alarm Conversion Kits

EZT Series Integra Med Touch Area Alarm & Zone Valve Box with EZ Backfeed

Installation, Operation, and Maintenance Instructions

Tri-Tech Medical Inc.

Med Touch Master Alarm

Pipeline. Medical Gas Pipeline Products

GAS CONTROL SYSTEMS SOLUTIONS OVERVIEW Manifold Systems Control Panels HP/UHP Regulators Pressure Gauges Valves&Fittings

Pipeline. Medical Gas Pipeline Products

SMS GSM Alarm Messenger

IntesisBox BACnet/IP Server - Notifier ID3000 series

ThermoControl 0 C - 10 C - 20 C - 30 C

GasGard 100 Control System

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Installation & Operating Instructions for Med Touch Series Area, Master & Combination Alarm Systems

Ohio Medical is the only name you need to know for your medical suction and oxygen therapy and medgas equipment needs.

Ohio Medical is the only name you need to know for your medical suction and oxygen therapy and medgas equipment needs.

Interfacing with the ADAM Module

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

HIGH CAPACITY PRODUCT LINE

4/18/2017. *2012 edition of NFPA 99 has gone through a major overhaul. *This document is now a Code.

Innovative protection that combines power and flexibility

CV-350 TCP/IP Access Control System. System Overview

Installation & Operating Instructions for ZT and EZT Integra Touch Series Area Alarm Zone Valve Box Systems

Product Training Module: Honeywell TruStability Board Mount Pressure Sensors: Uncompensated/Unamplified NSC Series

operations, Environmental & Instrumentation engineering solutions to the Commercial & Industrial segment in the Middle East. ARE

/8 DIN Level Indicator

The Centron Presidio Monitoring System. Centron. Presidio. Rees Scientific. An ISO 9001:2008 Company

CRIOTEL. The complete solution for local and remote monitoring of cryogenic tanks under pressure

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

100% Oil-Free - Guaranteed

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Touchpoint Pro Flexible Gas Control System

Cold chain monitoring technologies. Facility monitoring

Y-Plant Alert. Alarm Annunciator and Sequence of Event Recording System. BU 04M01A02-01E-A

Integra Med Touch Series LCD Area Alarm & Zone Valve Box Systems

HIGH CAPACITY PRODUCT LINE

Flexible Air-sampling Smoke Detection

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

API MARINE BMS4 REMOTE SOUNDING SYSTEM FOR BALLAST AND SERVICE TANKS

wireless. web-based. worthy of the name RACO.

S/601 Controller Installation Manual

RS485 MODBUS Module 8AI

When reliability is vital. Alemite Carbon Shield TM Systems deliver

DC Series Area, Master and Combination Alarm Systems Opreator s Manual

Sierra Series 900 Single & Dual Channel System. Instruction Manual

Installation & Operating Instructions for Integrated Series Area Alarm Zone Valve Box Systems

Gas Pressure Alarm Box SGPA Series. Operation Manual

Control Relay Modules

Course Outline. Course Introduction Purpose of the course Course Overview Program Outline Instructor Information

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

APPLICATION DATA SHEET

Heatless Desiccant Compressed Air Dryers

Added password for IP setup page : Password must be in IP format!

CBI-064. User Manual. Caddx to KNX-BUS Interface

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Alert-3 LCD Alarm v2.0

Airflow Sensors Line Guide

PRODUCT REVIEW Honeywell HC900 Hybrid Vacuum Furnace Control System

Titus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

CALIDUS tm the Modular micro Gas Chromatograph

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

SAM-MAX Refrigerant Monitors

TrueAlarm Fire Alarm Systems

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

21-light Remote Annunciator. Owner s Manual

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

TPM Product Type 107-D108-XNT 64-channel digital output module with pluggable terminal

Detection, Protection, Innovation

PBI Manual. Paradox to KNX-BUS Interface

Process Alarm Module RTA 421

Airflow Sensors Line Guide

HART XL High Sensitivity Smoke Detection

Ultraview SL2400 With Wireless-LAN-Option

USER MANUAL FOR OPERATING SYSTEM

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

Affordable wireless monitoring without compromise

AIS750 Series Alarm Annunciator

Products and performance

MIRADOR Real Time Monitoring

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

The future of lighting management. Cutting costs and carbon keeping your building compliant.

Process Alarm Solutions

STEAMPAK Series BurnerPAK BMS Burner Management Systems

ModBus DE-1 INSTALLATION AND USER MANUAL

EVOSAFE-SERIES TM ULTRA-LOW TEMPERATURE FREEZERS

Two-Channel Gas Controller

FLOW CONTROLLER TYPE S/601

TruStability Board Mount Pressure Sensors

Installation, Operation, and Maintenance Instructions

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

FIRECLASS Networking. Addressable Fire Alarm Control Panels From Software version 21. Product Application and Design Information FC-A-FCNET-A

Advanced Test Equipment Rentals ATEC (2832)

TCC-34. Features: TISSUE CULTURE

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Transcription:

w w w. g e n t e c h e a l t h c a r e. c o m M E D I C A L M O N I T O R I N G, A L A R M A N D C O N T R O L S Y S T E M S I n t e r n a t i o n a l E d i t i o n Technology for a Better Future

Company Overview Genstar Technologies Company, Inc. (GENTEC ), founded in1969, is a global industry leader in the manufacturing of welding apparatus, pressure regulators, and gas control systems. It is GENTEC s mission to provide customers with high quality, value-added products and services that surpass the strictest safety standards. All GENTEC products are manufactured in an ISO 9001 and ISO 13485 certified facility by our experienced and dedicated workforce, using exquisite craftsmanship in conjunction with computerized automation, stringent quality control, and advanced test equipment. Additionally, as a total system solution provider, GENTEC offers technical support, on-site evaluation, and design/ implementation. GENTEC engineers examine all customer requirements in order to develop and recommend the best customer -specific solutions. The company takes great pride in fostering a strong relationship with each and every customer. Today, GENTEC sells its products through a vast distribution network which extends to thousands of customers worldwide.

T a b l e o f C o n t e n t s System Diagram GUMACS TM Overview Medical Gas Area Alarm Medical Gas Master Alarm Medical Gas Combination Alarm Advanced Applications Appendix 1 2 3-4 5-6 7-8 9-11 12 M E D I C A L G A S P I P E L I N E P R O D U C T S

G e n s t a r T e c h n o l o g i e s System Diagram 1

GUMACS TM Overview Gentec Universal Monitoring, Alarm and Control System TM is a highly modular system utilizing the most advanced technologies in electronics and software. The modular design can implement limitless configurations to meet different monitoring/ control requirements. Future expansion can be achieved through upgradable firmware, software, and additional panels. GUMACS TM alarm series complies with the latest edition of NFPA 99 and optionally for HTM 02-01. GUMACS TM alarm series have built-in networking capability and can be implemented to standard RS-485 and Ethernet network systems. Furthermore, GUMACS TM alarm series accept all 4-20 ma and voltage signals, and can monitor customized readings or alarm conditions such as humidity, temperature, concentration levels, and flow rates in addition to typical pressure readings. With these versatilities, GUMACS TM alarm series are often applied to industrial, laboratories, and other applications. Customized Software Implementation of an intelligent monitoring system with networking capability like the GUMACS TM is made easy with Object Visual Lab, the interactive software generating package. Having a strong working relationship with Object Visual Lab, Gentec is able to provide customized software to complement GUMACS TM alarm systems when advanced monitoring/control requirements are involved. In addition, trend data can be collected and saved for later analysis to help facilitating future projects. 2

GUMACS TM Series Medical Gas Area Alarm Area Alarm with Local Sensors GUMACS TM Series Area Alarm is CE marked and NFPA 99 compliant. Designed to accept a variety of input signals, GUMACS TM Series Area Alarm is often used to monitor pressure, flow rate, temperature, humidity, concentration, and other safety indexes. If needed, GUMACS TM Series Area Alarm can also offer relay switch output control capability. Built-in RS485 communication port allows each GUMACS TM Series alarm to be networked for remote monitoring. The physical data will be processed and displayed on site by the area alarms. In addition, GUMACS TM System Console can request data from the slave modules, the area alarms and master alarms. Key Features Modular system configuration 1 to 16 input channels available Pressure units are customizable (Psig, kpa, Bar, MPa, inhg, and mmhg ) Can be used to monitor pressure, flow rate, temperature, humidity, concentration, and other safety indexes High/low alarm limits and silence time are customizable Built-in RS-485 communication port for networking Accept 4-20 ma current inputs and single-ended voltage signals One contact switch output per input channel Displays error message when pressure transducer is not connected Compact size with large four-digit LED numerical displays Dual color LEDs for system statuses All parameters can be field adjustable Labels can be customized upon request Alarm volume is adjustable 3

Electrical and Physical Specifications GUMACS TM Series Medical Gas Area Alarm Mechanical Front Panel Case Body Physical Dimension (Width x Height x Depth ) Wall Opening (Width x Height) Injection Molded Plastic (PCABS, V0 Flame Rated) Metal Alloy Overall: 1~4 Channel: 300mm x 135mm x 107mm 5~6 Channel: 300mm x 175mm x 107mm 7~8 Channel: 300mm x 215mm x 107mm (Depth beneath the wall is 95mm) 5~6 Channel: 272mm x 165mm 1~4 Channel: 272mm x 125mm 7~8 Channel: 272mm x 205mm Electrical Power Requirements Analog Input Relay Output Buzzer Communication RS-485 Port Input: 100~240 VAC, 0.5 A Maximum Input Type: (1) Single-ended, voltage (2) Differential, voltage (3) 4~20 ma current supplying 15 VDC (4) 4~20 ma current not supplying 15 VDC Working Range: ±10 VDC/4~20 ma Safe Range: ±14 VDC/0~28 ma Maximum Resolution: 14 bit or 1% of sensor full range Channels: 1 output per 1 input channel Range: 0.15 A at 48 VDC/1 A at 30 VDC/0.5 A at 120 VAC Adjustable Intensity 9600/19200 baud, standard (8-bit data, no parity, 1 stop bit) Dimensions Ordering Information BAA - R - 03 - OVA Example: Area Alarm Sensor Type L: Local Sensor R: Remote Sensor Number of Numerical Channels (01 to 16 Normally) BAA - R - 03 - OVA indicates an area alarm (remote sensor) for oxygen, vacuum, and medical air. Gas Type O: Oxygen V: Vacuum A: Medical Air I: Instrument Air N: Nitrogen 2: Nitrous Oxide C: Carbon Dioxide W: WAGD Vacuum 4

GUMACS TM Series Medical Gas Master Alarm Master Alarm (up to 32 inputs) GUMACS TM Series Master Alarm is CE marked and NFPA 99 compliant. It is used to monitor the operation conditions of source equipments such as air compressors, vacuum pumps, and/or manifold systems, etc. GUMACS TM Series Master Alarm can also offer relay switch output control capability when required. Built-in RS485 communication port allows each GUMACS TM Series alarm to be networked for remote monitoring. The physical data will be processed and displayed on site by the master alarm. In addition, GUMACS TM System Console can request data from the slave modules, the area alarms and master alarms. Although not done conventionally, GUMACS TM Series Master Alarm can be used as an Area Alarms Monitoring Center. When connected, the working conditions of the area alarms will be displayed on the Area Alarms Monitoring Center. This would be a good solution for a medium-sized central monitoring project. Key Features Can expand up to 64 TTL or contact switch inputs Can offer up to 48 switch output capability Built-in RS-485 communication port for networking Can be upgraded to a combination alarm if numerical displays are required Accept both normally open (N/O) and normally closed (N/C) switches High/low alarm limits and silence time are customizable Can be used to monitor the conditions of area alarms Labels can be customized upon request Alarm volume is adjustable 5

GUMACS TM Series Medical Gas Master Alarm Electrical and Physical Specifications Mechanical Front Panel Case Body Physical Dimension (Width x Height x Depth ) Wall Opening (Width x Height) Electrical Power Requirements Analog Input (for first module) Digital Output (for one expansion module) Digital Input (for one expansion module) Numerical Display Communication RS-485 and RS-232 Port Injection Molded Plastic (PCABS, V0 Flame Rated) Metal Alloy Overall: 1~16 Channel: 300mm x 135mm x 107mm 17~32 Channel: 300mm x 215mm x 107mm 33~48 Channel: 300mm x 295mm x 107mm 49~64 Channel: 300mm x 375mm x 107mm (Depth beneath the wall is 95mm) 1~16 Channel: 272mm x 125mm 17~32 Channel: 272mm x 205mm 33~48 Channel: 300mm x 285mm 49~64 Channel: 300mm x 365mm Input: 100~240 VAC, 0.5 A Maximum Input Type: (1) Single-ended, voltage (2) Differential, voltage (3) 4~20 ma current supplying 15 VDC (4) 4~20 ma current not supplying 15 VDC Working Range: ±10 VDC/4~20 ma Channels: 16 Maximum Safe Range: ±14 VDC/0~28 ma Maximum Resolution: 14 bit or 1% of sensor full range 5 VDC, -2.6 ma per Channel Maximum Number of Channels: 16 Maximum Omron G2R-1, G2R-14, G2R-1A, G2R1A4 or Grayhill 70-OAC5, 70-ODC5, and Compatibles 5 VDC, 24 ma per Channel Maximum Number of Channels: 16 Maximum Grayhill: 70-IAC5, 70IDC5, and Compatibles Resolution: Large 7-segment, four-digits LED 9600/19200 baud, standard (8-bit data, no parity, 1 stop bit) Dimensions Ordering Information BMA - 01-00 Master Alarm Number of Digital Input 01: 1~16 Digital Inputs 02: 17~32 Digital Inputs 03: 33~48 Digital Inputs 04: 49~64 Digital Inputs Number of Digital Output 00: 0 Digital Outputs 01: 1~16 Digital Outputs 02: 17~32 Digital Outputs 03: 33~48 Digital Outputs Example: BMA - 01-00 indicates a master alarm for 1~16 input channels. 6

GUMACS TM Series Medical Gas Combination Alarm Flexibility of Module Placement GUMACS TM Series Combination Alarm GUMACS TM Series Combination Alarm is CE marked and NFPA 99 compliant. Integrating the numerical display functions and master alarm functions, the combination alarm is sometimes more preferable. It can be used to monitor the operational conditions of source equipment and other numerical safety indexes. GUMACS TM Series Combination Alarm can also offer relay switch output control capability when required. Built-in RS485 communication port allows each GUMACS TM Series alarm to be networked for remote monitoring. The physical data will be processed and displayed on site by the combination alarm. In addition, GUMACS TM System Console can request data from the slave modules, area alarms and master alarms. Key Features Can be expanded to handle up to 64 TTL or contact switch inputs and 48 TTL or relay (contact switch) outputs Built-in RS-485 communication port for networking High/low alarm limits and silence time are customizable Relative positions of modules can be adjusted to meet the space requirements or limitations Displays error message when pressure transducer is not connected Labels can be customized upon request Alarm volume is adjustable 7

GUMACS TM Series Medical Gas Combination Alarm Electrical and Physical Specifications Mechanical Front Panel Case Body Physical Dimension Wall Mounting Hole Injection Molded Plastic (PCABS, V0 Flame Rated) Metal Alloy Customized Customized Electrical Power Requirements Analog Input (for first module) Digital Output (for one expansion module) Digital Input (for one expansion module) Numerical Display Wiring Input: 100~240 VAC, 0.5 A Maximum Input Type: (1) Single-ended, voltage (2) Differential, voltage (3) 4~20 ma current supplying 15 VDC (4) 4~20 ma current not supplying 15 VDC Working Range: ±10 VDC/4~20 ma Channels: 16 Maximum Safe Range: ±14 VDC/0~28 ma Maximum Resolution: 14 bit or 1% of sensor full range 5 VDC, -2.6 ma per Channel Maximum Number of Channels: 16 Maximum 5 VDC, 24 ma per Channel Maximum Number of Channels: 16 Maximum Resolution: Large 7-segment, four-digits LED Omron G2R-1, G2R-14, G2R-1A, G2R1A4 or Grayhill 70-OAC5, 70-ODC5, and Compatibles Grayhill: 70-IAC5, 70IDC5, and Compatibles Termination Analog Input, I/O, and RS-485: PCB mounted screw terminal connections AC Power: 3 pin AC power connections Communication RS-485 and RS-232 Port 9600/19200 baud, standard (8-bit data, no parity, 1 stop bit) Ordering Information EMA - R - 02 - OV - 01-00 Combination Alarm Sensor Type L: Local Sensor R: Remote Sensor Number of Numerical Channels Number of Digital Input Gas Type 01: 1~16 Digital Inputs O: Oxygen 02: 17~32 Digital Inputs V: Vacuum 03: 33~48 Digital Inputs A: Medical Air 04: 49~64 Digital Inputs I: Instrument Air N: Nitrogen 2: Nitrous Oxide C: Carbon Dioxide W: WAGD Vacuum Number of Digital Output 00: 0 Digital Outputs 01: 1~16 Digital Outputs 02: 17~32 Digital Outputs 03: 33~48 Digital Outputs Example: EMA - R - 02 - OV - 01-00 indicates a combination alarm (remote sensor) with 2 numerical channels (oxygen, vacuum), 1~16 digital input channels, and 0 digital output. 8

Advanced Applications Master Alarm Upper Network/ PC/Internet 2-gas Area Alarm RS485 Network 3-gas Area Alarm Intelligent Alarm/Control Station/ Logs-Keeping/ Shared folder 4-gas Area Alarm GUMACS TM System Console GUMACS TM System Console is a powerful industrial PC-based system. As a station host, Intelligent Alarm/Control Station (IACS) can be expanded to monitor a great number of analog/digital inputs and provide output control capabilities. With Gentec customized software, IACS can easily meet or exceed customer s monitoring requirements. In addition, trend data can be collected and saved for later analysis to help facilitate future projects. As a network master of Intelligent Alarm/Control Network (IACN), GUMACS TM System Console can manage a variety of GUMACS TM Series alarms and other devices. All digital and analog inputs are first processed locally and then sent to the System Console via the RS-485 network in order. More complicated computing, data logging, trend analyzing, and intelligent decision making tasks are carried out by the System Console. It is also possible to deliver the information to upper network. SYSTEM SPECIFICATIONS: High performance industrial PC with flat panel display Analog and digital inputs Analog and digital output capabilities Built-in RS-485, RS-232, and Ethernet ports EXPANSION OPTIONS: Touch panel, voice mail, fax transmission Additional digital and analog IO expansion modules Customized system software Connect to upper level hospital network and Internet 9

Advanced Applications MASTER ALARM MONITORING COMPUTER ETHERNET DATA PROCESSING COMPUTER ETHERNET RS485 RS485 MASTER ALARM MASTER ALARM AREA ALARM AREA ALARM OPTIONAL ACCESSORIES AREA ALARM MONITORING COMPUTER Gentec Central Monitoring System Quality control and quality assurance Trend data analyzing helps decision making, thus improving efficiency of operations management Can be integrated into existing hospital management system 10

Advanced Applications e-hospital Solution INTERNET Medical Gas Source Equipment Monitoring Medical Gas and Vacuum Monitoring Master Alarm Fax, Voicemail Area Alarm Hospital Server Database, HL7 Humidity and Temperature Monitoring Air Quality Monitoring Nurse Call Monitoring 11

Appendix Medical Gas Alarm Systems Provides: Visual Indications to indicate normal functions of the pipeline system. Visual Indications and Audible Indications to WARN that the routine replacement of cylinders or other engineering action is required. Visual and Audible Emergency Alarms to inform that abnormal conditions have occurred which may require urgent action by the user. This alarm condition will require a rapid response by the various departments staff. (HTM 02-01) Master Alarms shall monitor the operations and conditions of the supply source, the reserve source (if any), and the pressure in the main lines of each medical gas pipeline systems. Area Alarms shall monitor all medical gas, vacuum, and piped WAGD systems in Level 1 and Level 2 health care facilities. Level 1 Medical Piped Gas and Vacuum Systems Systems serving occupancies where interruption of the piped medical gas and vacuum system would place patients in imminent danger of morbidity or mortality. Level 2 Medical Piped Gas and Vacuum Systems Systems serving occupancies where interruption of the piped medical gas and vacuum system would place patients at manageable risk of morbidity or mortality. Medical gas alarms are required at Level 1 and Level 2 healthcare facilities. (NFPA 99, 2005) Related Regulations: NFPA 99 (National Fire Protection Association) HTM 2022, HTM02-01 (Health Technical Memorandum) ISO 7396-1, ISO 7396-2 12

Genstar Technologies Company Inc. 4525 Edison Avenue, Chino, CA 91710, USA Tel: 909-606-2726 Fax: 909-606-6485 www.gentechealthcare.com Copyright 2009 Genstar Technologies Co., Inc CATA#: MED07V0909