Waste water ejection unit

Similar documents
Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data

PV3000S Professional Pond Vacuum

USER S MANUAL ATH WH220

TTV 4500 / TTV 4500 HP / TTV 7000

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

Operating Manual. VIENNA Hot Display

VC-1, VC-1-SL, VC-2-L, VC-2-SL

TFV 900 OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN

Installation and operating instructions. DK energy storage and DK energy buffer

Compression Sprayers TECH DATA SHEET /03/17. Ersatzteile Spare Parts Pièces de Rechange

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

Operation Manual. Trash Water Pump ARTICLE Image similar

Operating Instructions UniTech Perfect

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

FSW300 Series Flow Switch

Operating instructions

Installation, Operation and Maintenance Manual. 3AV 1 to 3AV 430

Lifting Station Type ABS Sanimax

CRU-S Series Stainless Steel Condensate Recovery Unit

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

TDS 20 R / TDS 30 R / TDS 50 R

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

Instructions manual DEHUMID HP50

Installation and Operating Instructions. Models: T4-12LOW-9IS

ENGLISH USER S MANUAL PRE SOAKER 3600

Operating Instructions

High Pressure Washer 130

Instruction manual. Water treatment Boiler system D 30 L

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285

TTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN

DUST EXTRACTOR MODEL No: CDE1000

CombiGrinder. Instruction manual. Grinder for cattle, horse and pet clipper blades. swiss made. Version/Index: CombiGrinder/A 09-16

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

600W Hand Blender. Model: SP20160 (all colours) Helpline: v1.0. SP20160_IM.indd 1 26/07/ :38

Compact Pressure Washer 100

RESISTENT PLUS D A CH Gebrauchsanleitung GB IRL AUS USA NZ CDN IND Instructions for Use... 12

Model: 1100 Float-Controlled Condensate Trap, PN 25

1592P01. for liquids in piping DN

Propane Flame Projector Safety instructions and operating manual

O P E R A T I N G M A N U A L

Steam Generator v2.0. Model: SI9021N. Helpline. SI9021N_IM.indd 1 28/10/ :45

Universal vacuum. Operation Manual LS 5000 ESW. Machine no. Models. Universal vacuum LS 5000 ESW Original Operation Manual

RESISTENT EXTRA 3592, 3602 RESISTENT EXTRA PLUS 3592P, 3602P

100 Series Maxi Internal Filters

FHA 1100 A1 Domestic Water Pump

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

PowerVent. Installation manual (GB) English. Store this document in a safe place UK

OPERATION AND MONTAGE MANUAL ROOF FANS

Operation Manual for Drying Storage Cabinet with Drying Unit U-5002

Operating Instructions!

Instruction Manual. Electronic gas and smoke detector GRM

Operating instructions Electric agitator RE80Ex. T-Dok-520-GB-Rev.5 Article no Translation of the original operating instructions

User instructions. VA20HD, VA55HD, VA55IND and VA75IND. Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

Installation & Service Manual

Operating instructions DULCO flex DFDa Peristaltic Pump

CE Unit is suitable for material transport. The transported gas may be up to 80 C.

Operating Instruction Centrifugal fans without scroll (Translation of the Original) BA-RLE-AC /2014 RLE RLA

Whole Room Dryer WRD, WRD/110

BEFORE USING THE DISHWASHER/CONNECTIONS

Installation and assembly instructions. for standard configuration radial blowers

3 in 1 Can opener with bottle opener & knife sharpener Model: SP20110N

1.5L Fryer v1.0. Model: SD6060N. Helpline. SD6060N_IM.indd 1 07/10/ :58

KESSEL Grease separator EasyClean free Standard, Direct - oval in NS 2, 4, 7, 10, 15, 20, 25, 30 for set-up in frost-free rooms

OPERATION AND MONTAGE MANUAL ROOF FANS

Original Operating Instructions V-VTE

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

BSK-RPR Fire Damper. Additional operating instructions according to

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

Manual. Above-counter dispenser for hot drinks OTHG /12

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

OPERATING MANUAL CDP 115 Peltier cooling unit for waterbaths

MiniSkim. Inspiring Excellence in Fish Keeping! Instruction version: 17/08/2012.

Electronic Temperature Controller 70304,

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

Operating Manual. Please keep this manual. with the unit! Cooling Unit. For Heat Recovery Unit santos (F) 570 DC. Status:

Commercial backpack vacuum cleaner

BKA-EN Fire Damper. Additional operating instructions according to

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

Compression Sprayers CLEANER 3275PP, 3270PP, 3275PE, 3270PE PROFI PLUS 3275P, 3270P PROFI PLUS 3275P, 3270P TECH DATA SHEET /03/17

Operating instructions DULCO flex DFDa Peristaltic Pump

ANLAGENBAU HEAT EXCHANGER w w w. a nla g enba u-b oehm er. d e Version 05/2015

EYS SEPARATOR EYS 01 G. USER MANUAL for EYS SCREW-PRESS SEPARATOR MODEL EYS 01 G. User Manual for EYS 01G Screw-Press Separator

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

HELMUT KÄMPKEN GMBH OPERATING MANUAL

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions.

CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

HOT WASHER MODEL NO: KING150

Installation and operating instructions KEMPER KHS-Timer-Set Figure and Figure

Transcription:

Waste water ejection unit Over ground box SWH 500/50-80 SWH 500/50-80 Operation manual

Table of contents: Page Declaration of conformity... 3 1. General... 4 1.1 Introduction... 4 1.2 Enquiries and orders... 4 1.3 Technical data... 4 1.4 Range of application... 5 1.5 Accessories... 5 2. Safety... 5 2.1 Marking of the notes contained in the operation manual... 5 2.2 Personnel development and training... 5 2.3 Dangers in case of non-observance of the safety notes... 6 2.4 Safety-conscious way of working... 6 2.5 Safety notes for the operator/user... 6 2.6 Safety notes concerning maintenance, inspection, and assembly works... 6 2.7 Unauthorised modification and fabrication of spare parts... 6 2.8 Unauthorised modes of operation... 7 3. Transport and temporary storage... 7 3.1 Transport... 7 3.2 Temporary storage/conservation... 7 4. Description... 7 5. Installation... 8 6. Commissioning... 8 7. Maintenance/repair... 9 8. Malfunctions; causes and elimination... 9 9. Warranty... 10 10. Technical modifications... 10 11. Dimensions... 10 Appendixes Appendix 1 Spare parts list... 11 Appendix 2 Example of installation... 11 2

Declaration of conformity - According to EC low voltage directive 73/23/EEC, Appendix III B - According to EMC directive 92/31/EEC and 93/68/EEC - According to Machinery directive 2006/42/EC --------------------------------------------------------------------------------------------------------------- We, the herewith declare ZEHNDER Pumpen GmbH Zwönitzer Str. 19 08344 Grünhain-Beierfeld, that the waste water ejection units of the type series SWH conform to the following relevant regulations: - EC low voltage directive 93/68/EEC, Appendix I - EMC directive 92/31/EEC and 93/68/EEC - Machinery directive 2006/42/EC Applied conform standards, particularly - EN 809 State 1998 - EN 60 335-1 State 2006 (concept) - EN 60 335-2-41 State 2004 - EN 50 081-1 State 1993 - EN 50 082-1 State 1994 Grünhain, 22/12/2009 Matthias Kotte Product development 3

1. General: 1.1 Introduction This operating manual is valid for the waste water ejection units of the type series SWH 500. If the instructions of the operation manual especially the safety instructions - are not observed, or in case of unauthorized modifications of the device or the installation of non-original spare parts, the guarantee expires automatically. The manufacturer assumes no liability for damages resulting from such behaviour! Such as any other electrical device, this product may fail due to absence of mains voltage or a technical failure. If damage could occur, an emergency power supply, a second unit and/or an offgrid alarm device should be provided according to the application. We as manufacturer are at your disposal for consultation also after the purchase. In case of failures or damages, please contact your retailer. Manufacturer: ZEHNDER GmbH Pumpen und Anlagenbau Zwönitzer Straße 19 08344 Grünhain-Beierfeld Manufactured sizes: SWH 500/50 SWH 500/65 SWH 500/80 SWH 500/50 duplex SWH 500/65 duplex SWH 500/80 duplex State of the operation manual: March 2009 1.2 Enquiries and orders: In case of enquiries or orders, address yourself to your specialist retailer. 1.3 Technical data: SWH 500 simplex and duplex SWH 500/50 SWH 500/65 SWH 500/80 Output power P 1 380 W 850 W 850 W Output power P 2 210 W 430 W 430 W Voltage U 230 V 230 V 230 V Frequency f 50 Hz 50 Hz 50 Hz Nominal power reception I nenn 1.8 A 3.7 A 3.7 A Speed n 2800 min -1 2800 min -1 2800 min -1 Max. discharge flow Q max 7.5 m³/h 9.5 m³/h 10 m³/h Max. discharge height H max 7.5 m 14 m 8.5 m Max. medium temperature t max 40 C short-term 90 C Pressure connection G 1 ¼ G 1 ¼ G 1 ¼ Dimensions 500x520 mm 500x520 mm 500x520 mm xh Materials: Tank PE PE PE Pump housing Stainless steel Stainless steel Stainless steel Running wheel PA 6 PA 6 PA-6 Shaft 1.4301 1.4301 1.4301 Pressure pipe Stainless steel Stainless steel Stainless steel Sealings NBR NBR NBR 4

1.4 Range of application The waste water ejection units of the type series SWH 500 are suitable for the discharge of sewage and/or waste water out of hand washbowls, rinsing tanks, washing machines behind grease separators etc. and may be used in private homes, in the industrial sector or agriculture. They are used where the above-mentioned installations are installed below the backwater level of the channel and the waste water must be pumped upwards. ATTENTION The waste water ejection units of the type series SWH must not be used for the discharge of sewages containing excrements and in front of grease separators. 1.5 Accessories The waste water ejection units are delivered completely with pump, switching system and non-return valves (integrated into the pump). 2. Safety: ( from: VDMA sheet 24 292 ) The operation manual at hand provides basic notes which must be taken into account during assembly, operation and maintenance works. Therefore, before assembly and commissioning, this operation manual must be read by the assembler as well as by the responsible personnel/operator at all costs. It always must be available on site of operation of the machine/unit. The general safety notes listed under the main point safety are not the only notes to be taken into account. Please also observe the specific safety instructions, such as those for private use, listed under other main points. 2.1 Marking of the notes contained in the operation manual The safety notes contained in this operation manual which can cause danger to persons are specifically marked by the following general danger symbol Safety sign according to DIN 4844 - W 9, The following symbol warns against dangers caused by voltage Safety sign according to DIN 4844 - W 8 In case of safety notes the non-observance of which can cause danger to the machine and its functioning, the word ATTENTION is inserted Notes that are directly attached to the machine, such as - arrow indicating the direction of rotation - marking of liquid connections must be observed and kept in completely readable condition at all costs. 2.2 Personnel development and training The personnel responsible for operation, maintenance, inspection and assembly must have the corresponding qualifications for those types of work. Area of responsibility, competence and the surveillance of the personnel must be regulated precisely by the operator. If the personnel do not possess the necessary knowledge, they must be trained and instructed. By order of the operator, the instruction and training, if necessary, can be carried out by the manufacturer/supplier. Furthermore the operator must make sure that the personnel have completely understood the content of the operation manual. 5

2.3 Dangers in case of non-observance of the safety notes The non-observance of the safety notes can cause dangers to persons as well as to the environment and the machine. If the safety notes are not observed, this can result in the loss of all compensation claims. In detail, non-observance can for instance result in the following damages for example: - Failure of important functions of the machine/unit - Failure of the prescribed methods for maintenance and repair - Endangerment of persons through electrical, mechanical and chemical influences - Endangerment of the environment through leakage of hazardous substances 2.4 Safety-conscious way of working The safety notes listed in this operation manual, the existent national regulations on accident prevention as well as possible internal working, operating, and safety instructions of the operator must be observed. 2.5 Safety notes for the operator/user - Hot or cold machine components which could cause danger must be secured against contact by the customer. - Protection against contact with moving parts (e.g. coupling) must not be removed while the machine is operating. - Leakages (e.g. of the shaft sealing) of hazardous materials to be conveyed (e.g. explosive, toxic, hot) must be discharged in such a way that no danger arises for persons or the environment. The legal requirements must be observed. - Endangerments through electric power must be eliminated (details concerning this, see e.g. the regulations of the VDE (German Association for Electrical, Electronic and Information Technology) and the local energy suppliers). 2.6 Safety notes concerning maintenance, inspection, and assembly works The operator must make sure that all maintenance, inspection, and assembly works are carried out by authorised, skilled, and qualified personnel which are adequately informed by having thoroughly studied the operation manual. Generally, works on the machine are only to be carried out when the machine is turned off. The procedure of switching off the machine, which is described in the operation manual, must be observed at all costs. Pumps or pump units which convey media that are hazardous to health must be decontaminated. Immediately after completion of the works, all safety and protection devices must be reattached and/or reactivated. Before restart, the points listed in the chapter commissioning must be taken into consideration. 2.7 Unauthorised modification of the machine and fabrication of spare parts Retrofitting or modifications of the machine are permitted only after having consulted the manufacturer. Original spare parts and accessories authorised by the manufacturer ensure the safety. The use of other parts can lead to the removal of liability for the resulting damages. 6

2.8 Unauthorised modes of operation The operational reliability is only guaranteed, if the machine is used as intended according to chapter 1 General. The limit values stated in the data sheet must not be exceeded. ATTENTION ACHTUNG Also a device operating automatically such as an ejection unit must not be operated without supervision for a longer time period. 3. Transport and temporary storage 3.1 Transport The ejection unit must not be thrown, hit or dropped. 3.2 Temporary storage/conservation For temporary storage and conservation, it suffices if the unit is stored in a cool, dark, dry, and frostprotected place. The unit should be stored in horizontal position. 4. Description The waste water ejection units of the type series SWH are ejection units allowing the automatic discharge to a higher level out of hand washbowls, rinsing tanks, washing machines and similar. The discharge of waste water containing excrements is not allowed with these units. Composition and mode of operation simplex unit: The ejection units are delivered in assembled condition ready for connection to 230 V, 50 Hz (alternating current). The motor is equipped with a thermal overload protection and switches off automatically if it is too hot. After cooling, it will be reactivated automatically. According to the guidelines of the German Institution for Structural Engineering (DIBt), the units are equipped with non-return valves and operate automatically with an integrated floating switch: if the liquid level inside of the tank exceeds a defined level, the floating switch activates the pump and the pumping process starts. After the tank is pumped out (floating switch decreases) the pump switches off automatically. In doing so, the integrated non-return valve prevents the backflow of the discharged water from the pressure pipe into the tank. Composition and mode of operation duplex unit: The ejection units are delivered in assembled condition ready for connection to 230 V, 50 Hz (alternating current). The motor of the pumps is equipped with a thermal overload protection and switches off automatically if it is too hot. After cooling, it will be reactivated automatically. If waste water flows into the ejection unit, the water level inside of the pilot tube screwed into the upper side of the tank raises and compresses the air inside of the pilot tube until the pressure actuates the dynamic pressure switch inside of the switching box. With it, the pump is switched-on and discharges the water from the tank through the pressure pipe into the channel located on a higher level. The changeover switch effects an alternating switching-on of the pumps. Only in case of an overload operation (one pump cannot manage the incoming water) a second pump is activated. The non-return valves inside of the pump prevent the water backflow from the pressure pipe into the tank. The switching system is equipped with alarm contacts to which, additionally to the alarm buzzer e, other alarm devices (bell, horn, lamp, etc.) may be connected. 7

5. Installation - Disconnect the power supply before carrying out any kind of work on the unit. - According to standard DIN VDE 070, the socket must be equipped with grounding terminals (Safety socket) - The electrical connections must not be exposed to humidity. Installation place: The unit must be installed in a frost-free place and on a plane floor. Connection of the inlets: 3 x inlet sleeve DN 100 for sewer pipe, 1 x threaded sleeve G 1 ½ IG with blank plug The necessary inlet sleeves DN 100 must be opened! Inlets which are not used must be closed! Connection of the pressure pipe: There is a ball valve with an internal thread G 1 ¼ at the end of the pressure pipe. Ventilation: The ejection units are ventilated through a ventilation pipe DN 40-50 via the roof. The pipe is mounted to the respective seal collar of the tank cover. Please ensure that the pipe extends max. 100 mm into the tank! Electrical connection simplex unit The plug of the unit (protective plug) is connected directly before commissioning. In doing so, it must be ensured that the electric device meets the valid VDE regulations. Electrical connection duplex unit The switching box must be attached in such a manner that the air hose for the pneumatic level control can be installed continuously rising and without kinks. Connect the plugs of the pumps to the couplings of the switching system. The plug of the unit (protective plug) shall be connected directly before commissioning and the pumps are switched to automatic operation. In doing so, it must be ensured that the electric device meets the valid VDE regulations. Please also observe the separate operation manual of the switching system. The switching system is already preset in factory. 6. Commissioning Prior to commissioning, all connections should be checked again for proper assembly. Subsequently, connect the plug to the socket. Now, the simplex unit is ready for operation. In case of duplex units, both pumps are switched to automatic operation. Now, effect a test run. For this purpose, the collecting tank is filled by a normal inlet (washbowl, etc.). The unit must switch-on automatically, empty the tank and switch-off. After switching-off, no water shall flow back from the pressure pipe into the tank. During the test run, all pipes and valves are checked for tightness and sealed again, if necessary. If the ejection units operated properly, the pumps of duplex units rest in automatic operation. 8

Water escaping out of the hole in the pump housing in case of ejection units SWH 500 is construction-conditioned (ventilation) no failure! 7. Maintenance/repair - Disconnect the power supply before carrying out any kind of work on the ejection unit. For inspection and cleaning unscrew the inspection cover. In order to prevent functional disorders and blockages, regularly remove solid matters and contaminations from the tank and the inlet filter of the pump. The cleaning interval depends on the accumulation of contaminations. - For troubleshooting and inspection of the motor or the electrical components, please contact your specialist retailer. 8. Malfunctions; causes and elimination - Disconnect the power supply before carrying out any kind of work on the ejection unit. Failure Cause Removal 1. No motor rotation - Mains voltage missing or faulty - Check power socket - Connect mains plug - Running wheel is blocked - Remove cover; remove possibly existing foreign objects, in case of reoccurrence, removal by specialist. - Motor is overloaded - If the motor does not switch-on after cooling, removal by specialist. - Level control is defective - Removal by specialist - Motor is defective - Removal by specialist 2. Motor rotates but does not convey - Pressure pipe is blocked/hose is bended - Remove blockage and/or bends, effect a test running. - Pump ventilation in blocked - Clean the ventilation hole in the pump housing - Ball valve is blocked/closed - Clean/open - Non-return valve in not correctly installed - Rotate, check the function 3. Motor runs in short intervals - Non-return valve is leaky - Clean and/or replace the nonreturn valve 4. Motor rotates with a high noise - Foreign object reached the device - Removal by specialist 9

9. Warranty As manufacturer, for this unit we provide a warranty of 24 months from date of purchase. Your sales receipt passes for verification. During that warranty period, we gratuitously remedy all deficiencies which are attributed to material or fabrication defects by either repairing the unit, or by replacing the defective parts (to our choice). Defects which are attributed to misuse or wear are excluded from warranty. We will assume no responsibility for consequential damages that are caused by a breakdown of the unit. 10. Technical modifications We reserve the possibility of technical modifications for the purpose of further development. 11. Dimensions SWH 500 simplex pressure connection G 1 ¼ inlet DN 100 inlet DN 100 ventilation hole DN 40/50 inlet DN 100 inlet DN 100 cable gland pressure connection G 1 ¼ SWH 500 duplex pressure connection G 1 ¼ inlet DN 100 inlet DN 100 ventilation hole DN 40/50 inlet DN 100 inlet DN 100 inlet DN 100 cable gland pressure connection G 1 ¼ inlet G 1 ½ 10

Appendix 1 Spare parts list SWH 500 simplex Qty. Designation Art. no. Qty. Designation Art. no. 1 Collecting tank SWH 500 100.180 1 Non-return valve R 1 ¼ 117056 1 Screw cap ZE1332 1 Double nipple G 1 ¼ 117055.11 1 O-ring for screw cap 133108 1 Pressure pipeline VA 2 Blank plug G 1 ½ 117320 1 O-ring 40x6 117321 1 Cable gland PG 11 117323 1 E-ZW 50 A-2 for SWH 500/50 22016.0 1 E-ZW 65 A for SWH 500/65 80.565 1 E-ZW 80 A for SWH 500/80 80.580 Spare parts list SWH 500 duplex Qty. Designation Art. no. Qty. Designation Art. no. 1 Collecting tank SWH 500 100.180 2 Non-return valve R 1 ¼ 117056 1 Screw cap ZE1332 2 Double nipple G 1 ¼ 117055.11 1 O-ring for screw cap 133108 1 Control hose 10 m 60221 2 Blank plug G 1 ½ 117320 1 Pilot tube SWH 500 1 O-ring 40x6 117321 1 Y-section DN 32 VA 200.130 2 Cable gland PG 11 117323 1 Control unit ZPS 2 600.780 2 E-ZW 50-2 for SWH 500/50 22016.7 2 E-ZW 65 for SWH 500/65 80.565.5 2 E-ZW 80 for SWH 500/80 80.580.4 Appendix 2 Example of installation: Pos. Component part 1 Waste water ejection unit 2 Inlet washbowl with siphon 3 Washing machine 4 Electrical connection 5 Additional connection possibility 6 Ventilation (then, without activated charcoal filter) 7 Pressure pipe with loop in channel 2009 by Zehnder GmbH 11