Thermal Stability Systems

Similar documents
Installation Instruction. Puritan Bennett. Wall Air Water Trap For 800 Series Ventilator Basic Cart. Pla

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

24 VAC SYSTEM CONTROL KIT

Installation Instructions

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

Installation & Operation Manual NCB-E Condensing Combi-Boilers

Teflon Rotary Drum Pump

24 VAC SYSTEM CONTROL KIT

DRAIN WATER TEMPERING INSTALL

Industrial Flanged Immersion Heaters

Columbia Boiler Company

SIERRA RADIANT HEAT MAJESTIC OAK VENTED GAS LOG KIT INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS

SYSTEM CONTROL KIT. Model: CK-62. Designed for use on SWG Series Power Vent Hoods for controlling oil fired heating appliances with 120 VAC controls.

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT

! WARNING. Replacement Head Mechanism INSTRUCTION MANUAL MM-413F

25M01A-100 to 25M01A-199 HSI Single Stage Combination Gas Valve

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-284. Series PSE-800 Probe Type Low Water Cut-Off for Steam Boilers

Installation Instructions

Fig. 1 - Unit PGD4, PGS4, WPG4

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

Page 1 of 18. Part# /5/2013

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

BGH Series Hot Surface Ignition Control

120 VAC SYSTEM CONTROL KIT

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Oil Furnace USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

Owner s Information Manual

INSTALLATION INSTRUCTIONS

Installation Instructions Dual Fuel Ranges

INSTALLATION INSTRUCTIONS

Installation Instructions

FLT93 Installation, Operation and Troubleshooting Guide

Dynaflex Hot melt hoses

southbend A MIDDLEBY COMPANY INSTALLATION AND OPERATION MANUAL CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) GAS BOILERS MODELS:

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

Decorative Low Profile Integrated Kit

Installation Instructions Millennia Cooktops

Packaged Gas/Electric

US Filtermaxx. 200,000 BTU Waste Oil Burner

Discontinued Old-Style Switch

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

Energy Manager INSTALLATION INSTRUCTIONS. Keep these instructions with the boiler at all times for future reference

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

Part#: 26B113 HEAVY DUTY CAST IRON ROTARY DRUM PUMP

Check It Panel. 1 Phase Simplex Demand Dose Operation, Maintenance & Installation Manual. Introduction. Safety Guidelines

Installation Instructions

GAS COOKTOP MODELS: CTG365D, CTG305D, CTG304D TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

USER S INFORMATION MANUAL

WARNING DESCRIPTION PART NUMBER QTY PLUMBING, DYNATEMP DRAIN QUENCH BRACKET, THERMOSTAT DRAIN QUENCH

Installation Instructions

L A signature series TA T N E RE O, A L L A T S IN

Installation Instructions

INSTALLATION INSTRUCTIONS FOR FREESTANDING DUAL FUEL

! WARNING. Before using product, read and understand instructions.

Installation Instructions

Installation Instructions

WATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.

QVE1901U Flow Switch. Technical Instructions Document No September 20, Description. Features. Application.

Installation Instructions

Installation Instructions

Dual Billet Bottle Bracket Assembly Instructions

GAS COOKTOP INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN. IMPORTANT Save these instructions for local electrical inspector s use.

Hanson LED C e i l i n g F a n

Installation Instructions

USER'S INFORMATION MANUAL

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Universal Fire Tube Boiler Wall Mount Models

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit

Installation Instructions for W2H Series Signals

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

Automatic Dryers. Installation. Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.

User s Manual. For the SHORE POWER CONNECTION MONITOR MODEL 9151

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-315(C)

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

Installation Instructions

Models: GW/R-T GW/R-2-T GW/R-3-T

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG

Installation Instructions Part No , Part No Part No

Instruction Manual. Crescent Cuber Models WME-2500SRH. hoshizakiamerica.com

WARNING. Failure to install this kit within the guidelines might adversely affect safety, performance, component life and warranty coverage.

E-Z Zone Pack 3+1 And 5+1 Boiler Manifold System

Installation Instructions

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Installation Instructions

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

HELIATOS Bottom Feed Connector Installation Instructions Introduction. Step 1

Outdoor Armor Water Heater Installation & Operation Manual Models:

DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

120 VAC SYSTEM CONTROL KIT Model: CK-63

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

INSTALLATION INSTRUCTIONS

Installation Instructions

Transcription:

Thermal Stability Systems for Oil Tank Heating Unit Model: TSSHU6002 PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION. THESE INSTRUCTIONS MUST BE LEFT WITH THE USER AND SHOULD BE RETAINED FOR FUTURE REFERENCE BY QUALIFIED SERVICE PERSONNEL. Thermal Stability Systems www.thermalstabilitysystems.com (732) 689-5587

SAFETY: WARNING: IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE, OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER OR SERVICE AGENCY. WARNING: THERMAL STABILITY SYSTEMS HEATING UNITS ARE DESIGNED TO HEAT NO. 1, NO. 2 OR UP TO B20 BIOFUEL FUEL OIL. NEVER USE GASOLINE OR A MIXTURE OF OIL AND GASOLINE. WARNING: ALL INSTALLATION AND SERVICES MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. This page contains various warnings and cautions found throughout the Oil Tank Heating Unit. Please read and comply with the statements below. CAUTION: Installation MUST conform to local building codes. WARNING: This heating unit must only be installed indoor. WARNING: Disconnect all power to the boiler or furnace prior to installation. Failure to do so may cause injury from electrical shock. WARNING: This heating unit must only be connected to a boiler or furnace primary controller. INTRODUCTION: This Oil Tank Heating Unit is intended for use within a two line residential or light commercial oil heating installation. The heating unit is installed inline with the return line to the oil storage tank. The heating unit obtains power from the boiler or furnace primary controller. The heating unit will sense the temperature of the heating oil returning to the oil storage tank. If the temperature of the heating oil is below the set point temperature, the heating unit will active it s heating coil. The heating unit will only become active if the heating oil is below the set point temperature AND the boiler or furnace is active. TSSHU6002 Page 2 12/13/2007

INSTALLATION: MOUNTING WARNING: This heating unit must only be installed indoor. The model TSSHU6002 heating unit is to be spliced into the return line from the boiler or furnace to the oil storage tank. Locate the unit on a vertical surface. The unit can be located on the boiler or furnace or indoor wall along the return line from the boiler or furnace to the oil storage tank. Once location has been determined, mount the unit utilizing the three mounting feet (see Figure A). If unit is to be mounted on a sheet metal wall, use three #8 x ¾ self tapping sheet metal screws. If unit is to be mounted on an indoor wall, use three appropriate mounting fasteners with no less than size #8 screws. ELECTRICAL POWER WARNING: Disconnect all power to the boiler or furnace prior to installation. Failure to do so may cause injury from electrical shock. WARNING: This heating unit must only be connected to a boiler or furnace primary controller. CAUTION: All installation and services must be performed by qualified service personnel. CAUTION: Installation MUST conform to local building codes. The model TSSHU6002 heating unit obtains electrical power from the boiler or furnace primary controller. The unit comes equipped with 6 Line and Neutral wire leads within the unit that must be spliced into the boiler or furnace primary controller. The unit is also equipped with a ground screw located near the Line and Neutral wire leads. The unit will except metal-clad cable or conduit through the port located under the power switch. Remove the black grommet before installing the cable or conduit connector. The units wiring must be mechanically protected by the use of metal-clad cable or conduit per local building code. Utilizing the appropriate wire connectors, connect the unit s black lead to the load side of the primary controller (burner motor lead). Connect the unit s white lead to the neutral lead of the primary controller. Connect the unit s ground screw to the field grounding connection. FLUID CONNECTIONS WARNING: Clear all heating oil from return line prior to connecting to unit. TSSHU6002 Page 3 12/13/2007

CAUTION: Installation MUST conform to local building codes. The model TSSHU6002 heating unit utilizes two 3/8 bulkhead female NPT connectors for the fluid connections to/from the oil storage tank. These connectors are used to splice the unit inline with the return line from the boiler or furnace to the oil storage tank. The return line must conform to local building codes. Using the appropriate 3/8 male NPT connectors (not supplied), splice the return line into the unit. CAUTION: The 3/8 bulkhead female NPT connector nuts must be held with a suitable wrench during the tightening of the 3/8 male NPT connectors. The line from the boiler or furnace is to be connected to the port labeled IN (FROM TANK) (see Figure A). The line from the unit to the oil storage tank is to be connected to the port labeled OUT (TO TANK) (see Figure A). The portion of the line from the unit to the oil storage tank that is outdoor may be wrapped in an insulating material according to local building codes. Figure A TSSHU6002 Page 4 12/13/2007

TESTING Once all electrical and fluid connections have been checked, the unit is powered by switching the SYSTEM PROTECTION ENABLED switch ON (located on the right side of the unit). The switch will light green showing the unit has electrical power. Temporally active the boiler or furnace and check for any fluid leaks. Retighten fluid connections if necessary. Note: the unit s heating coil with not energize if the heating oil is above the set point temperature. TROUBLESHOOTING WARNING: There are no serviceable components located under the unit s cover; do not remove cover. If unit s SYSTEM PROTECTION ENABLED switch does not light green once the switch is ON, recheck wired connections at the boiler or furnace primary controller. If unit is properly connected, contact supplier where unit was purchased or Thermal Stability Systems customer service. If heating oil leakage is detected from within unit, contact supplier where unit was purchased or Thermal Stability Systems customer service. TSSHU6002 Page 5 12/13/2007