Extension Module. Fig.1

Similar documents
Interface Module RS232/485. INTERFACE MODULE RS232/485 Instruction Manual 03-INT-02-17

Fire Control Panel FS4000

Fire Control Panel FS4000

REPEATER FS5200R INSTRUCTION MANUAL

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

REPEATER FS5200R OPERATION MANUAL

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

CONVENTIONAL FIRE CONTROL PANELS FS 5100 and FS 5200

UniPOS Wireless Fire Alarm Control Panel VIT 01 WIRELESS FIRE ALARM CONTROL PANEL VIT01 INSTRUCTION MANUAL

Fire Control Panel FS5100

Configuration and Operation Manual for the Unipos

FEC400 Series. Installation Manual

DIGITAL TEMPERATURE RELAY TR-100

MANUAL FOR ASSEMBLY AND OPERATION OF ELECTRIC FLOW-THROUGH BOILER/MODULE WITH THREE STAGE ELECTRONIC CONTROL

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

EL-OEM-3 OEM Packaged Voltage Data Logger

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

FC722 Fire control panel

MANUAL FOR ASSEMBLY AND OPERATION OF ELECTRIC FLOW-THROUGH BOILER WITH RELAY CONTROL

SEE DISCLAIMER ON REVERSE

RELEASE DEVICE CONTROLS

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface

Forever Flowering Greenhouse Suggested Setup Wiring Diagrams

FC724 Fire control panel

FC722 Fire control panel

Intelligent addressable fire alarm control panel

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D)

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Frequently asked questions: Intelligent Transmitter Series

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

4010 Fire Alarm Parts List

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

DIGITAL ALARM UNIT Model ALU-AP

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

S2000-ASPT. Fire Alarm and Extinguishing Control Panel. Engineer s and User s Manual

1U ULTRA Compact System

FC724 Fire control panel

Battery control panel BCP-136

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

CONTROL PANELS. Tech Data Sheet D01688GB1 10/2012 Fire Detection. Control Panels of the FX 3NET (ALC) Fire Detection System

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

ATS Annunciator - MODBUS

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

MANUAL FOR ASSEMBLY AND OPERATION OF ELECTRIC FLOW-THROUGH BOILER/MODULE WITH THREE STAGE CONTROL

PDD-8PCI. Power Distribution Board With Supervised Interface. Installation and Specifications Manual

21-light Remote Annunciator. Owner s Manual

Soft Start Series MP700 Solid State, Reduced Voltage

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

FEC403EN Installation Manual

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel

Halton SAFE / 7.14 user guide and installation instructions

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

EXTINGUISHING AGENT RELEASE MODULE

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Components Brochure DX CONNEXION

JENCO ELECTRONICS, LTD.

Labkotec Ice Detector

Gas Detection System TOX ALARM DG2000-Garage

FC2020 Fire control panel

Across-the-Line SERIES MP300 Combined Manual and Automatic

CONTROLLER FOR INDUSTRIAL MUSHROOM CULTIVATION

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

MODEL B2 INSTALLATION MANUAL

The EN54 Part 2 & 4 Fire System

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

STRIKE GUARD DELIVERS:

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

"DMTeh" Ltd. Pleven. Fire conventional panel FP 9000 Installation, setup and operation.

4100U City and Relay Cards Installation Instructions

TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

CONTROL AND INDICATOR MODULE. Potok-BKI INSTRUCTION MANUAL

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

20 Light Remote Annunciator

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Warranty Registration

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

WM3000 WIRELESS MODULES

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

The EN54 Part 2, 4 and 13 Fire System

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Exit Stopper. STI-6400 Series

Operating Instructions. For. Alarm Control Module. Model SSR 500

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

Installation guide for J4 Junction Box for R4 AIS Transponder System

Fire control panels FC360

Transcription:

Extension Module Type FD 4201 05/12.17 General Description Module FD 4201 is optional for the fire control panel FS4000. Expands the functionality of the fire control panel, as follow: - Connection of fire control panel FS4000 in a system of a repeater FS5200R and/or several remote fire control panels FS4000, FS5100, FS5200, FS5200E; - Trigger dry contact fire output for each zone that is in Fire condition. The module could work only with the latest version of the fire control panel FS4000 (fire control panels with serial numbers higher than 4000). Module FD4201 is manufactured in 4 versions (2,4,6 or 8 dry-contacts), related to the 4 types of the FS4000 panel (2,4,6 or 8 fire zones). The RS485 interface is built-in the module in each of its 4 types. The module includes: - Interface RS485 for connection with repeater FS5200R; - Potential free dry-contacts for Fire condition (one to each zone of the fire control panel FS4000). - The unit consists of a printed circuit board and ribbon cable. Fig.1 The power supply and communication interface are on the same ribbon cable connecting the FS4000 fire control panel and the FD4201 extension module. Page1

Technical Data Relay outputs for Fire condition - type potential free, switching - power supply 3A/125VAC; 3A/30VDC Interface RS485 - network address not-programmable, the 4 digits of the serial number of the FS4000 panel - data exchange speed fixed 9600 bits/s. Operational temperature range from minus 5 о С to 40 о С Relative humidity resistance max 93% at 40 о С Dimensions 100 х 50 х 15 mm Weight 0,60 kg Installation The installation sequence is as follow: 1. Preliminary steps: 1.1. Unpack the module. 1.2. Configure the jumpers of the dry-contacts (normal open or normal close) depending on the specific project requirements, pos. 3 (fig. 2). 1.3. Terminate the interface RS485 network line (refer the of Fire Control Panel FS4000): - if the connected fire control panel is the first or the last one in the network line, switch on the jumper in the module, pos. 1 (fig. 2). - if the fire control panel is in the middle of the network line, then the jumper is switched off. Fig.2 Page2

2. Installation of Extension Module FD 4201 in fire control panel FS4000 Fig.3 2.1. Open the front cover of the fire control panel. - remove the access level key (fig.3, pos.4); - remove the plastic plugs (fig.3, pos.3); - remove the screws of the dedicated openings on the front cover (fig.3, pos.1 and pos.2); Page3

2.2. Switch off the mains power line in FCP. 2.3. Switch off the back-up batteries in FCP. Fig.4 2.4. Pull-out the main interface board (fig.4) following the sequence: - push the holders on the top side (fig.4, pos.1); - take out (from the top holders) the interface board and leave it fixed on the bottom holders (fig.4, pos. 2); - pull the interface board out of the bottom side holders (fig.4, pos. 3), till fully released; Page4

Fig.5 2.5. The main interface board in FCP is mounted to the bottom holders, as illustrated on fig.5, pos.1. 2.6. The bottom side of the extension module is mounted on the holders (fig.5, pos.2); The top side of the extension module is pushed (fig.5 pos.6) until the top-side holders click to fix it (fig.5,pos.3); 2.7. Connect the ribbon cable to the module, fig.5 pos.4 and to the connector located on the FS4000 main PCB, fig.5 pos.5. The connectors are provided with a slot, determining the direction of the connection. network line Page5

3. Connecting the interface and the commutated output devices 3.1. Take out the network line and the line of end output devices through the dedicated openings (refer the of Fire Control Panel FS4000). 3.2. The network line is connected to module 4201, on the terminals А and В, pos. 2 (fig. 2). 3.3. Connect the end output devices lines in dry-contacts terminals of module 4201, pos. 4 (fig. 2). 4. Start-up procedure of the FS4000 panel with FD4201 installed 4.1. Switch on the mains power line in FCP. 4.2. Switch on the back-up batteries in FCP. 4.3. Close the front cover of the fire control panel. The entered delay for the FS4000 monitored outputs is the same like the delay of the FD4201 dry contacts. Testing Extension Module FD 4201 is tested after installation as an element of the fire control panel or during maintenance activities. 1. Testing of the dry-contacts part. - Set time-delay of the outputs 0 minutes in the fire control panel by means of jumper J1 (refer the of Fire Control Panel FS4000); - Simulate fire condition in a randomly selected zone (for example: line/zone 1); - The fire control panel enters Fire condition and the dry-contact, corresponding to the selected zone, is activated (example: Rel1 for line 1); - If the dry-contact is configured like normally open contact, then in Fire condition it is closed; - Press button to reset the fire control panel. The dry-contact (e.g.: Rel1) must be reset to its initial position; - If no other dry-contact of another line is going to be tested, reset the delay of the fire control panel to its initial settings (0, 1, 2, 3, 4 or 5 minutes). ATTENTION! The dry-contacts of the FD4201 extension module must not trigger 220 Vac (the maximum rating is 125 Vac or 30 Vdc)! Page6

2. Testing the interface part. The interface part RS485 of the Extension Module FD 4201 is tested as a part of a local network of repeater FS5200R and remote fire control panels. The parameters of the repeater have to be set-up accordingly, in order to communicate with the FS4000 panel. The network address and the data communication speed along RS485 in a fire control panel, equipped with an extension module are fixed: - The fire control panel network address coincides with its serial number; - the data communication speed is fixed 9600 bits/s. Complete set PCB Extension Module Ribbon cable Instruction manual Package - 1 pc. - 1 pc. - 1 pc. - 1 pc. Technical service It should be done only by an authorized person as it during the actions for the technical maintenance of the fire control panel. Warranty The warranty period is 24 months from the date of sale. The manufacturer guarantees the normal performance of the unit providing that the operation requirements set herewith have been observed. The manufacturer does not bear warranty liabilities for damages caused through accidental mechanical damage, misuse, adaptation or modification after production. The manufacturer bears warranty liabilities for damages in the unit caused through manufacturer's fault only. Manufacturer UniPOS LTD 47 San Stefano Str. Pleven 5800 http://www.unipos-bg.com Page7

Page8