SECTION AIR OUTLETS AND INLETS

Similar documents
D. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser.

SECTION AIR DUCT ACCESSORIES

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

SECTION DUCTWORK

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

EXHAUST FAN SCHEDULE

SECTION DUCTWORK

SECTION (15820) - AIR DUCT ACCESSORIES

SECTION CONVECTION HEATING AND COOLING UNITS

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

DARTMOUTH COLLEGE DESIGN March 15, 2003 & CONSTRUCTION GUIDELINES

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

SECTION (15833) - HVAC POWER VENTILATORS

SECTION (15767) - UNIT HEATERS

SECTION CONVECTION HEATING AND COOLING UNITS

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories for each type of product indicated.

AIR DUCT ACCESSORIES

CONTENTS. B. System Design and Performance Requirements

Linear Floor Heaters

B. System Design and Performance Requirements

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

Part # Page Dampers Supported Directly From Structure 5. Dampers Supported From Ductwork Above 4

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

A. Codes and Standards that are Standard at the University:

COHASSET, MA March 6, The following is the HVAC outline specifications, which defines the scope of work of the HVAC system.

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

lindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

SECTION AIR DOORS

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

SECTION AIR HANDLING UNIT

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

SECTION AIR COILS

PDH & Professional Training

SECTION AXIAL FANS

DIVISION 23 - HVAC HVAC Air Distribution

SECTION HEATING BOILER FEEDWATER EQUIPMENT

Section Plaster Accessories

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

A. This Section includes air-handling units with coils for indoor installations.

DIVISION 15 MECHANICAL

Convectors Steam / Hot Water November, 2009

15900 HVAC INSTRUMENTATION AND CONTROLS

SECTION AIR COILS

Florida Department of Transportation

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

SECTION HEATING BOILERS

SECTION CUSTOM INDOOR CENTRAL-STATION AIR-HANDLING UNITS For large systems, 50,000 cfm or more.

SECTION CENTRAL HVAC EQUIPMENT

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

FIRE RATED PRODUCTS GENERAL PRODUCT OVERVIEW. Fire Rated Products

April Rist. & Associates, Inc. Stock Catalog

Direct Fired Heater Model AD Specification

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

SECTION DOMESTIC WATER PUMPS

SECTION FAN COIL UNITS

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

University of Delaware

INNOVATIVE AIR DISTRIBUTION PRODUCTS

A. Standards: Except where modified or exceeded by the requirements of this Specification, conform to the following standards:

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

PATTERN CEILING DIFFUSERS

SECTION WATER-SOURCE UNITARY HEAT PUMPS

SECTION (15900) - INSTRUMENTATION AND CONTROL FOR HVAC

DIVISION 23 - HVAC HVAC Air Distribution

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

DIVISION 10 SPECIALTIES

1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - "Systems and Equipment.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION FIRE EXTINGUISHER CABINETS

Contents INDEX. TDM Series Indirect Fired Heaters

Cabinet Unit Heaters Steam / Hot Water

SECTION GYPSUM PLASTER

LABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

Transcription:

SECTION 23 37 00 AIR OUTLETS AND INLETS PART 1 - GENERAL 1.1 SUMMARY A. Section includes diffusers, light troffer diffusers, registers/grilles, door grilles, louvers, louvered penthouses, roof hoods, goosenecks. B. Related Sections: 1. Section 09 05 00 Common Work Results for Finishes: Execution and product requirements for Painting of ductwork visible behind outlets and inlets specified by this section. 2. Section 23 05 48 Vibration and Seismic Controls for sound performance criteria. 1.2 REFERENCES A. ADC 1062 (Air Diffusion Council) - Certification, Rating and Test Manual. B. AMCA 500 (Air Movement and Control Association) - Test Method for Louvers, Dampers and Shutters. C. ASHRAE 70 (American Society of Heating, Refrigerating and Air Conditioning Engineers) - Method of Testing for Rating the Airflow Performance of Outlets and Inlets. D. SMACNA (Sheet Metal and Air Conditioning Contractors National Association) - HVAC Duct Construction Standard - Metal and Flexible. 1.3 SUBMITTALS A. Section 01 33 00 - Submittal Procedures: Submittal procedures. February 2018 Page 1 of 11 2018 FDG Section 23 37 00

B. Product Data: Submit data outlets and inlets sizes, finish, and type of mounting prior to submission. Submit schedule of outlets and inlets showing type, size, location, application, and noise level. C. Samples: Submit two of each required air outlet and inlet type. D. Test Reports: Rating of air outlet and inlet performance. E. Manufacturer's Certificate: Certify that products meet or exceed specified requirements. 1.4 CLOSEOUT SUBMITTALS A. Section 01 77 00 Closeout Procedures: Closeout procedures. B. Project Record Documents: Record actual locations of air outlets and inlets and send a copy to Stanford Maps and Records. 1.5 QUALIFICATIONS A. Manufacturer: Company specializing in manufacturing products specified in this section with minimum three years documented experience. 1.6 MOCK-UP A. Only required as directed by Designer or Project Manager. B. Provide typical exterior or interior ceiling module with supply and return air outlets. C. Locate where directed. D. Mock-up may be part of general ceiling mock-up specified in Section 01450. E. Mock-up may remain as part of the work. February 2018 Page 2 of 11 2018 FDG Section 23 37 00

1.7 WARRANTY A. Section 01 77 00 Closeout Procedures: Product warranties and product bonds. PART 2 - PRODUCTS 2.1 MANUFACTURERS 1. Titus 2. Price 3. Anemostat 4. Barber Coleman 5. Tuttle & Bailey 6. or approved equal 2.2 ROUND CEILING DIFFUSERS A. Product Description: Type: Round, adjustable pattern, stamped or spun, multicore diffuser to discharge air in 360 degree pattern, with sector baffles where indicated. B. Diffuser collar not more than 1 inch above ceiling per design and application. In plaster ceilings, provide plaster ring and ceiling plaque. C. Fabrication: Steel with baked enamel finish color to be determined by design. D. Accessories: Radial opposed-blade, Butterfly or combination splitter damper and multi-louvered equalizing grid with damper adjustable from diffuser face per design. 2.3 RECTANGULAR CEILING DIFFUSERS A. Type: Square, adjustable pattern, stamped, multi-core Square and rectangular, adjustable pattern multi-louvered diffuser to discharge air in 360 degree one way, two-way, three-way or four-way pattern with sector baffles where indicated per design. February 2018 Page 3 of 11 2018 FDG Section 23 37 00

B. Frame: Surface mount Snap-in Inverted T-bar Spline type per design and application. In plaster ceilings, provide plaster frame and ceiling frame. C. Fabrication: Steel with baked enamel finish color to be determined per design. D. Accessories: Radial opposed-blade Butterfly or Combination splitter damper and multi-louvered equalizing grid with damper adjustable from diffuser face. 2.4 PERFORATED FACE CEILING DIFFUSERS A. Manufactured by Titus unless approved otherwise. B. Type: Perforated face with fully adjustable pattern and removable face. C. Frame: Surface mount Snap-in Inverted T-bar Spline type per design and application. In plaster ceilings, provide plaster frame and ceiling frame. D. Fabrication: Steel with steel frame and baked enamel finish color to be determined per design. E. Accessories: Radial opposed-blade Butterfly or Combination splitter damper and multi-louvered equalizing grid with damper adjustable from diffuser face. 2.5 MODIFIED LIGHT TROFFER DIFFUSERS A. Type: Single or double plenum constructed independent of light troffer with volume and pattern controllers, air inlet either round or oval, top or side. Match diffusers to light troffer for airtight connection without tools. B. Fabrication: Galvanized steel with welded or soldered joints and finish matte black inside. February 2018 Page 4 of 11 2018 FDG Section 23 37 00

2.6 CEILING SLOT DIFFUSERS Stanford University Facilities Design Guidelines A. Type: Continuous wide slot, number of slots wide to be determined with adjustable vanes for left, right or vertical discharge; integral fire damper where design requires. B. Fabrication: Steel with factory clear lacquer, backed enamel finish, color to be selected. C. Frame: margin with countersunk screw concealed support clips for suspension system or support clips for T bar mounting and gasket mitered end border. Open end construction or end cap. D. Plenum: Integral, galvanized steel, insulated or non-insulated as design dictates. 2.7 CEILING SUPPLY REGISTERS/GRILLES A. Type: Streamlined and individually adjustable curved blades to discharge air along face of grille, one-way or two-way deflection. B. Frame: Margin with countersunk screw or concealed mounting and gasket. C. Fabrication: Aluminum extrusions with factory clear lacquer or prime coat finish as design dictates, color to be selected. D. Damper: Integral, gang-operated, opposed-blade type with removable key 2.8 CEILING EXHAUST AND RETURN REGISTERS/GRILLES A. Manufactured by Titus unless approved otherwise. B. Type: Streamlined blades, ¾ inch minimum depth, ¾ inch maximum spacing, with blades set at 45 degrees, vertical or horizontal face. C. Frame: Margin with countersunk screw concealed mounting. February 2018 Page 5 of 11 2018 FDG Section 23 37 00

D. Fabrication: Steel with 20 gage minimum blades, steel and aluminum with 20 gage minimum frame, or aluminum extrusions, with factory baked enamel, prime coated or clear lacquer finish per design, color as selected. E. Damper: Integral, gang-operated, opposed blade type with removable key operator, operable from face where not individually connected to exhaust fans. F. Gymnasiums: Provide front pivoted or welded in place blades, securely fastened to be immobile. 2.9 CEILING GRID CORE EXHAUST AND RETURN REGISTERS/GRILLES A. Type: Fixed grilles of ½ x ½ x 1 inch louvers. B. Frame: Margin with countersunk screw mounting, or concealed mounting, Channel lay-in frame for suspended grid ceilings. C. Fabrication: Aluminum with factory clear lacquer baked enamel finish color to be selected. D. Damper: Integral, gang-operated, opposed-blade type with removable key 2.10 CEILING LINEAR EXHAUST AND RETURN GRILLES A. Type: Streamlined blades with 90 degree one-way or two-way deflection, 1/8 x ¾ inch on ¼ or ½ inch centers per design. B. Frame: ¼ inch margin, extra heavy for floor mounting, with countersunk screw or concealed mounting. C. Fabrication: Steel with 20 gage minimum frames and 22 gage minimum blades, steel and aluminum with 20 gage minimum frame or aluminum extrusions with factory baked enamel, prime coated or clear lacquer finish per design, color to be selected. D. Damper: Integral, gang-operated, opposed blade type with removable key February 2018 Page 6 of 11 2018 FDG Section 23 37 00

2.11 WALL SUPPLY REGISTERS/GRILLES A. Type: Streamlined and individually adjustable blades, ¾ inch minimum depth, ¾ inch maximum spacing with spring or other device to set blades, vertical or horizontal face, single or double deflection per design B. Frame: Margin with countersunk screw concealed mounting and gasket C. Fabrication: Steel with 20 gage minimum frames and 22 gage minimum blades, steel and aluminum with 20 gage minimum frame or aluminum extrusions, with factory baked enamel, prime coat, clear lacquer finish per design, color to be selected. D. Damper: Integral, gang-operated opposed blade type with removable key E. Gymnasiums: Provide front pivoted or welded in place blades, securely fastened to be immobile. 2.12 WALL SUPPLY REGISTERS/GRILLES A. Type: Streamlined and individually adjustable curved blades to discharge air along face of grille with one way or two way deflection B. Frame: 1-1/4 inch margin with countersunk screw or concealed mounting and gasket per design C. Fabrication: Aluminum extrusions with factory clear lacquer or prime coat baked enamel finish, color to be selected. D. Damper: Integral, gang-operated, opposed blade type with removable key 2.13 WALL EXHAUST AND RETURN REGISTERS/GRILLES A. Type: Streamlined blades, ¾ inch minimum depth, ¾ inch maximum spacing, with spring or other device to set blades, vertical or horizontal face. February 2018 Page 7 of 11 2018 FDG Section 23 37 00

B. Frame: 1-1/4 inch margin with countersunk screw or concealed mounting C. Fabrication: Steel with 20 gage minimum frames and 22 gage minimum blades with factory baked enamel, prime coated, or clear lacquer finish per design, color to be selected. D. Damper: Integral, gang-operated, opposed-blade type with removable key E. Gymnasiums: Provide front pivoted or welded in place blades, securely fastened to be immobile. 2.14 WALL GRID CORE EXHAUST AND RETURN REGISTERS/GRILLES A. Type: Fixed grilles of ½ x ½ x 1 inch louvers B. Frame: 1-1/4 inch margin with countersunk screw mounting, concealed mounting or lay in frame for suspended grid ceilings C. Fabrication: Aluminum with factory clear lacquer, baked enamel finish per design, color to be selected. D. Damper: Integral, gang-operated, opposed-blade type with removable key 2.15 LINEAR WALL REGISTERS/GRILLES A. Type: Streamlined blades with 0-15 degree deflection, 1/8 x ¾ inch on ¼ or ½ inch centers per design. B. Frame: 1-1/4 inch margin with countersunk screw or concealed mounting and gasket C. Fabrication: Aluminum extrusions with factory clear lacquer, prime coat baked enamel finish per design February 2018 Page 8 of 11 2018 FDG Section 23 37 00

D. Damper: Integral gang-operated opposed blade or hinged single blade damper with removable key operator, operable from face per design. 2.16 LINEAR FLOOR SUPPLY REGISTERS/GRILLES A. Type: Streamlined blades with 0-15 degree deflection, 1/8 x ¾ inch on ¼ or ½ inch centers per design. B. Frame: 1-1/4 inch margin with countersunk screw or concealed mounting and gasket C. Fabrication: Aluminum extrusions with factory clear lacquer, prime coat baked enamel finish per design D. Damper: Integral gang-operated opposed blade or hinged single blade damper with removable key operator, operable from face per design. 2.17 FLOOR SUPPLY REGISTERS/GRILLES A. Individually adjustable or fixed blades, wide stamped border, single or double blade damper with setscrew adjustment per design. B. Fabricate of steel, welded construction, with factory baked enamel finish. 2.18 DOOR GRILLES A. Type: V-shaped louvers of 20 gage thick steel, 1 inch deep on ½ inch centers B. Frame: 20 gage steel with auxiliary frame to give finished appearance on both sides of door, with factory prime coat finish. 2.19 LOUVERS A. Louvers: As specified in Division 15: Mechanical. February 2018 Page 9 of 11 2018 FDG Section 23 37 00

B. Type: 4 or 6 inch deep with blades per design and application on 45 degree slope with center baffle and return bend, heavy channel frame, bird screen with ½ inch square mesh for exhaust and ¾ inch for intake C. Fabrication: 16 gage thick galvanized steel thick extruded, welded assembly with factory prime coat, baked enamel, anodized or fluoropolymer spray finish per design and application, color to be selected D. Mounting: Furnish with interior, exterior, flat flange angle flange, screw holes in jambs or masonry strap anchors for installation per design. 2.20 LOUVER PENTHOUSE A. Fabricate louver penthouses with mitered corners and reinforce with structural angles. B. Louver Penthouse: As specified in Division 15: Mechanical. Type: All welded assembly with 4 inch deep louvers, mitered corners with factory prime coat, baked enamel, anodized or fluoropolymer spray finish per design, color to be selected. 2.21 ROOF HOODS A. Fabricate air inlet or exhaust hoods in accordance with SMACNA HVAC Duct Construction Standards - Metal and Flexible. B. Fabricate of reinforced galvanized steel, minimum 16 gage base and 20 gage hood. Provide removable hood; bird screen with ½ inch square mesh for exhaust and ¾ inch for intake and factory, prime coat, baked enamel finish per design, color to be selected. C. Mount unit on minimum 12 inch high curb base with insulation between duct and curb. D. Make hood outlet area minimum of twice throat area. February 2018 Page 10 of 11 2018 FDG Section 23 37 00

2.22 GOOSENECKS A. Fabricate in accordance with SMACNA HVAC Duct Construction Standards - Metal and Flexible, of minimum of 18 gage galvanized steel. B. Mount on minimum 12 inch high curb base. PART 3 - EXECUTION 3.1 EXAMINATION A. Verify inlet/outlet locations. B. Verify ceiling and wall systems are ready for installation. 3.2 INSTALLATION A. Install diffusers to ductwork with airtight connection. B. Provide balancing dampers on duct take-off to diffusers, and grilles and registers, despite whether dampers are specified as part of the diffuser, or grille and register assembly. C. Paint ductwork visible behind air outlets and inlets matte black. Refer to Section 09 05 00 Common Work Results for Finishes 3.3 INTERFACE WITH OTHER PRODUCTS A. Check location of outlets and inlets and make necessary adjustments in position to conform to architectural features, symmetry, and lighting arrangement. END OF SECTION February 2018 Page 11 of 11 2018 FDG Section 23 37 00