System 2000 Automatic control switch 2 Standard. 1 Safety instructions. 2 Device components. 3 Function. Order-No. : Operating instructions

Similar documents
System 3000 Motion detector top unit 1.10 m Standard, Motion detector top unit 2.20 m Standard

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components

System 2000 System 2000 automatic control switch Safety instructions. 2 Device components

1 Safety instructions. 2 Device components. Light Management Universal automatic switch m. Art.-No.: AS Operating instructions

Standard automatic switch 1.1 m, Standard automatic switch 2.2 m

Automatic switch attachment Standard Installation Instructions

1 Safety instructions. 2 Device components. Observer 220. Art.-No.: W 220 WW. Operationsmanual

1 Safety instructions. 2 Device components. Presence detector. Operating instructions

Operating Instructions. Room Temperature Controller 230/10 (4) A~ with NC contact and On/Off button

Presence detector Komfort attachment Installation Instructions

Gira nurse call system Installation, start-up, operation. Gira emergency set

Remote alarm unit Art. Nr.:

Detailed operating instructions

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

Detailed operating instructions

Gira Sensotec / Gira Sensotec LED Motion detector, orientation light and contactless switch in one

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

Operating instructions

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

11,1 30. Ordering data

Lighting Control. Sensor Daylight 2. Daylight+Motion 3. Daylight+Motion+Control 4. Daylight+Motion+Control IP67 5

PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX..

Product and Applications Description

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

1. Basic safety information 3 2. Proper use 3

User Manual 120/240/300 Outdoor Motion Detector

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

UP 258E11 OPTISENS OFFICE

360º Surface Mount Ceiling PIR Light Controller

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

LEVEL SWITCH NP-3T DL v1.0 Installation instructions Order no E-no

18W Round LED Wall/Ceiling Light with Microwave Sensor

Data sheet. Function description. Benefits

0701 CO Light, HVAC, Monitoring, Brightness

2. Safety. 4. Function

Protecting you and your home

Connections, displays and operating elements C D E G H. Installing the control unit

OPERATING INSTRUCTIONS

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

Sensors Explained AUTOMATION

12W Round LED Wall/Ceiling Light with Microwave Sensor

Saving energy with Gira

360 Ceiling PIR Light Controller

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

PräsenzLight PräsenzLight PräsenzLight A.. PräsenzLight A..

360 Surface Mount Ceiling PIR Light Controller

Compact Movement Activated Sensor Installation Instructions

PresenceLight 180 PresenceLight 360

Description of the application programme for KNX occupancy detectors version 3.1

Rev KNX Technical Reference Manual Busch Präsenz tech 6131/ /11-500

PRODUCT INFORMATION. Uses tough, high quality PC diffuser, resistant to fracture and to ultraviolet light to limit discolouring.

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

FSTR- Series Microwave Motion Sensor (MSSD) Dimming Function/Detachable Version for LED Tri-proof Light & LED Batten. Introduction

DALI MSensor 02 Multi-sensor for DALI system

compact office 24V compact office 24V Lux

60W Multi PIR Bulkhead

Surface Mount Wall PIR Light Controller. Model: PDWM1500. Installation & Operating Instructions

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

compact office 24V compact office 24V Lux

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

Devices for Special Applications

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

DALI MSensor 02 Multi-sensor for DALI system

luxcontrol lighting control system basicdim basicdim ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor

Tri-level Control HF Sensor

Technical Manual MDT Motion Detector

Connections, displays and operating elements E F. 20s 3min

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Detector switch - Dual Tech SCS

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

luxcontrol lighting control system basicdim basicdim ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor

THE INNOVATIVE SOLUTION FOR MORE LIGHTING COMFORT LEDOTRON. DIGITALLY DEFINED DIMMING.

1. Basic safety information 3 2. Proper use 3

The two type sensors are innovative and active motion dimmable LED drivers or ballasts.

Passive infrared ceiling sensor

Detector switch - Dual Tech

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

Product and Applications Description

Movement controller comfort, Flush-mounted (Up) xx, xx

1. Basic safety information 3 2. Proper use 3

LUXOMAT Application examples for electricians and planners

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

LPC3BSP65 & LPC3BDP65

5W LED Energy Saver PIR Bulkhead

Tebis application software

. w. POWERHOUSE n MOTION DETECTOR MODEL PR511 OWNER S MANUAL

Busch-Watchdog presence. Overview and applications of presence detectors.

Model: PDSM1500. Installation & Operating Instructions 360º Surface Mount Ceiling PIR Light Controller

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Alarm System SECURE AS 302

Introduction. Dimming Function MC003V (Standard Version) MC003V R (Reinforced Version)

Transcription:

Order-No. : 2301.. Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause damage to the device and result in fire and other hazards. Danger of electric shock. Always disconnect before carrying out work on the devise or load. At the same time, take into account all circuit breakers that supply dangerous voltage to the device or load. Danger of electric shock. Device is not suitable for disconnection from supply voltage. The load is not electrically isolated from the mains even when the device is switched off. Do not press on the sensor window. Device can be damaged. Disconnect before mounting the cover, malfunction possible. The device is not suitable for use as a burglar alarm or other alarm. These instructions are an integral part of the product, and must remain with the end customer. 2 Device components Figure 1 (1) Insert (2) Frame (3) Motion detector (4) Lens 3 Function Intended use - Automatic switching of light, depending on heat motion and ambient brightness - Operation with concealed insert for dimming, switching or extension insert, 3-wire - Indoor mounting on concealed insert 32576902 10410709 I00 12.01.2012 1/7

Product characteristics - Extension of the detection area in combination with the 3-wire extension insert - Operation with 2-wire extension or installation button - Teach function for adjustment of the brightness threshold - Switch-on brightness permanently storable, with dimming insert - Light dimmable, with dimming insert and connected 2-wire extension insert - Creep zone protection - Run-on time limit i Sensitivity and run-on time cannot be changed. Automatic operation The motion detector detects heat motions of people, animals and objects. - The light is switched on when the detection area is entered and the brightness threshold is exceeded. The run-on time restarts with each detected motion. - The light is switched off if no motion is detected in the detection area and the run-on time has elapsed or the run-on time limit is reached. To avoid any light swings caused by a cooling illuminant, the motion detector does not evaluate any motion signals for a brief lockout time after switching off. The motion detector adjusts itself to the ambient conditions to keep the time as short as possible. The day/night switchover takes place after a delay of 30 seconds. Switching over is thus prevented by briefly illuminating or shadowing to the day/night operation. Run-on time limit The light is switched off after 90 minutes at the latest even if there is constant motion in the detection area. The light is only switched on again if the brightness drops below the threshold and motions are detected. Behaviour after a mains failure - Less than 0.2 seconds: The old switching position is restored after mains return. - 0.2 seconds until approx. 2 seconds: The light is switched on for the run-on time after mains return. - Longer than 2 seconds: The motion detector goes through a self-test for approx. 40 seconds after mains return. The light is first switched on. After approx. 10 seconds, the light is switched off. After the end of the self-test, the light is switched on for the duration of the run-on time. 4 Operation Switching on light for the duration of the run-on time A 2-wire extension or an installation button is connected. o Press 2-wire extension or installation button for less than 0.4 seconds. Light is switched on depending on brightness and motion. Motions are evaluated further and prolong the run-on time. i If the motion detector is combined with a dimmer insert, the light is always switched on to the saved switch-on brightness i The light cannot be switched off manually. Adjust the brightness Motion detector is combined with a dimming insert. The light can be dimmed temporarily. The next time the light is switched on, it is switched on again to the switch-on brightness A 2-wire extension is connected. Light is switched on. o 2-wire extension above, press for longer than 0.4 seconds. The light gets brighter up to maximum brightness. o 2-wire extension below, press for longer than 0.4 seconds. 32576902 10410709 I00 12.01.2012 2/7

Light gets darker to minimum brightness. i An installation button cannot be used to adjust the brightness. Switching the light on with minimum brightness Motion detector is combined with a dimming insert. A 2-wire extension is connected. Light is off. o 2-wire extension below, press for longer than 0.4 seconds. The light is switched on to minimum brightness for the duration of the run-on time. i An installation button cannot be used to switch on to minimum brightness. i If the 2-wire extension above is pressed for longer than 0.4 seconds, the light is switched on to minimum brightness and then brighter. Save switch-on brightness Motion detector is combined with a dimming insert. A 2-wire extension is connected. Light is on. o Set light to the required brightness. o 2-wire extension insert over entire surface, press for longer than 3 seconds. Switch-on brightness is saved. For confirmation, the light is switched off briefly and switched on again. i In the state as supplied the maximum switch-on brightness is saved. i An installation button cannot be used to save the switch-on brightness. Changing the brightness threshold The ambient brightness can be permanently saved as brightness threshold with the aid of the teach function. As-delivered state approx. 10 Lux. i Do not shadow the motion detector during the measuring process. i In combination with the automatic RMD stairway light: set the shortest run-on time on the RMD stairway light. i If there is low ambient brightness, the motion detector has difficulty detecting the changes in light, which are required to activate the teach function. Recommendation: During activation, provide additional illumination of the motion detector, e.g. with a flashlight. Figure 2 32576902 10410709 I00 12.01.2012 3/7

o Cover the motion detector with your hand for approx. 1 second at least three times within 9 seconds(figure 2). The teach function is activated after three light changes have been detected. For confirmation, the switched on light is switched off. If the light is switched off, this is switched on for approx. 1 second. After 30 seconds, the motion detector measures the brightness and saves it. For confirmation, the light is switched on for the duration of the run-on time. i If a value greater than 200 lux is saved, the motion detector switches to day operation independent of the brightness. 5 Information for electrically skilled persons 5.1 Fitting and electrical connection DANGER! Electrical shock when live parts are touched. Electrical shocks can be fatal. Before carrying out work on the device or load, disengage all the corresponding circuit breakers. Cover up live parts in the working environment. Selecting the installation location When choosing the installation location, the following points must be considered. o Select a vibration-free installation location. Vibrations can lead to unwanted switching. o Avoid interference sources in the detection area. Interference sources such as heaters, fans, air-conditioners and cooling illuminants can lead to unwanted switching. Motions crosswise to the motion detector (Figure 3) B can be detected more easily than motions approaching the motion detector (Figure 3) A. Thus, the cross walking range is greater than the walk to walking range. o Take direction of motion into account. Figure 3 All information regarding the range (Figure 4) applies to an installation height of 2.2 m. In the case of a deviating installation height, the range changes (Figure 5). o Determine installation height. 32576902 10410709 I00 12.01.2012 4/7

Figure 4 Figure 5 Installing the motion detector The concealed insert is connected and installed correctly (see Concealed insert instructions). i Further installation steps are necessary to ensure the protection rating IP 44 (see Seal set instructions) o Mount the motion detector with the frame onto onto concealed insert. Expanding the detection area To expand the detection area, connect a 3-wire extension insert with motion detector cover. The motion detector of the main unit also evaluates motion signals of the extension and, if necessary, switches the lighting on. The concealed insert is connected and installed correctly (see Concealed insert instructions). o Mount the motion detector with the frame onto the concealed insert. i Do not connect any main units in parallel. This can lead to light swings 32576902 10410709 I00 12.01.2012 5/7

5.2 Commissioning Configuring the motion detector Only when the brightness drops below the threshold will the light be switched on when there is motion in the detection area. o Adjust optional brightness threshold with teach function (see chapter 4. Operation). i Sensitivity and run-on time cannot be changed. Checking the detection area o Pace off the detection area, paying attention to reliable detection and interference sources. i Adjust any previous, possible brightness threshold or darken the room. 6 Appendix 6.1 Technical data Ambient temperature -15... +45 C Protection rating IP 20 Brightness setting approx. 1... 200 lx (and day operation) run-on time approx. 2 min Lockout time approx. 0.3... 4 s Installation height 1.10 / 2.20 m Detection angle 180 cross walking range approx. 12 x 6 m walk to walking range approx. 8 4 m 6.2 Troubleshooting Motion detector does not switch on Cause 1: The ambient brightness is greater than the adjusted brightness threshold. Adjust brightness value using teach function (see chapter 4. Operation). Cause 2: Motion detector does not detect any motions. Check detection area for any obstacles. Motion detector switches on without motion. Cause: Motion detector detects heat motions. Pay attention to interference sources such as heaters, fans, air-conditioners and cooling illuminants in the detection area. Motion detector switches off despite motion Cause 1: Run-on time limit is reached. The run-on time is limited to a maximum of 90 minutes. Cause 2: Motion detector is switched off on 3-wire extension insert. Switch on motion detector. Motion detector does not switch off after the set follow-up time has elapsed Cause: Motion detector detects motions constantly. Pay attention to interference sources such as heaters, fans and air-conditioners in the detection area. 6.3 Warranty The warranty is provided in accordance with statutory requirements via the specialist trade. Please submit or send faulty devices postage paid together with an error description to your responsible salesperson (specialist trade/installation company/electrical specialist trade). They will forward the devices to the Gira Service Center. 32576902 10410709 I00 12.01.2012 6/7

Gira Giersiepen GmbH & Co. KG Elektro-Installations- Systeme Industriegebiet Mermbach Dahlienstraße 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel +49(0)21 95-602-0 Fax +49(0)21 95-602-191 www.gira.de info@gira.de 32576902 10410709 I00 12.01.2012 7/7