The Ed Roberts Campus Berkeley, CA

Similar documents
The Ed Roberts Campus

Performance of Solar Water Heating Systems in the United States

Dehumidification: Energy Efficiency Comparisons

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

NET ENERGY WATER LOOPS A clear path to net zero energy buildings

Design and Operation of a Conditioning Energy Recovery Ventilator (CERV) for Passive Houses

Laboratory Evaluation of Hybrid and Advanced Water Heaters: Performance Overview in Hot Humid Climate

Farm Energy Audit Workshop

Daikin Altherma Selection Report

IES Whole-Building Energy Model Baseline Energy Model Input/ Output Report. East Liberty Presbyterian Church East Liberty Presbyterian Church

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

Annual environmental performance evaluation of light and heat in daylight harvesting systems using Radiance and NewHASP

Time-Based Scheduling of Residential Ventilation

Sivu 2/8 Rate data Description Suomi Shut off times total 0.0 h/day Weekends with shut off times yes Daytime rate of heat pump Time for daytime rate 5

MSP WRAP-AROUND MULTIPLE SMALL PLATE DEHUMIDIFICATION TECHNOLOGY VS. CONVENTIONAL DEHUMIDIFICATION IN DEDICATED OUTDOOR AIR SYSTEMS (DOAS)

Hot Water a Hot Commodity Better Buildings by Design, February 2012 Burlington, VT

Innovative Technologies [and Design Concepts] in Commercial Foodservice

Air System Sizing Summary for Lobby System Project Name: Existing Lobby 04/04/2005 Prepared by: psuae

Practical and Effective Approaches to Residential Ventilation for Production Builders

High Performance Building Guide 1

Matt Cooper, PE, BEMP, HBDP, Group 14 Engineering Ken Urbanek, PE, HBDP MKK Consulting Engineers, Inc.

Continuous Commissioning: A Valuable Partner to Retrofit Projects

Heat Pumps and Public Swimming Pools, a Perfect Match

AHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

2 Safety valve. 3 Pressure gauge. 4 Thermometer. 8 Ball valves

ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD (I-P Edition) Energy Standard for Buildings Except Low-Rise Residential Buildings.

Design Considerations For Dedicated OA Systems BY HUGH CROWTHER, P.ENG, MEMBER ASHRAE; YI TENG MA, ASSOCIATE MEMBER ASHRAE

The School District of Philadelphia Administration Headquarters

Des Places Residence Hall

In Search of the Magic Box: A Review of Crossover Conditioning/Ventilation/Dehumidification Devices on the US Market

A New Approach to Museum HVAC Design ASHRAE TECHNOLOGY AWARD CASE STUDIES

RECOMMENDATIONS FOR 15% ABOVE-CODE ENERGY EFFICIENCY MEASURES FOR RESIDENTIAL BUILDINGS

Air System Sizing Summary for AHU/CU-1 Project Name: Wilton Manors Fire Station#16 06/26/2016 Prepared by: L.N.I.

SOLAR HOT WATER AND HEAT PUMP BOOSTER ENERGY CALCULATION METHODOLOGY

In Search of the Magic Box: A Review of Crossover Conditioning/Ventilation/ Dehumidification Devices on the US Market

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

Produced by the Residential Solution Sales Division. Daikin AC Americas, Inc.

Variable Refrigeration Flow Systems Overview 10/11/2016

August 15, 2013 Page 1 of 19

Sustainable Hot Water: Better Design, Delivery, and Use

Architectural Engineering Senior Thesis Mechanical System Redesign

ASHRAE Headquarters Building: GSHP vs. VRF systems

EnergyPlus Testing with Global Energy Balance Test

HVAC 101. H V A C S y s t e m s

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

ASHRAE/IESNA Standard

Kimberly Rollins, Professor, Department of Economics, University of Nevada, Reno

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

High Efficiency Heating and Cooling Systems for Community Colleges Kirk Mescher, PE, LEED AP Principal ICCCFO

Session: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island

Auburn University Basketball Arena:

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

Copyright 2003 IBACOS, Inc. All rights reserved.

Evaporative Cooling in a Hot-Dry Climate

DISTRICT HEATING SCHEME FEASIBILITY STUDY FRANKTON FLATS QUEENSTOWN

New Steps towards Compact Solar Combisystems in Scandinavia

WLAC Facilities Committee Meeting. September 18, 2017

ENGINEERING. Edition No. 13 October 2002

VARIABLE HEAT RECOVERY IN DOUBLE BUNDLE ELECTRIC CHILLERS. Richard J Liesen 1, Rahul J Chillar 2 1 University of Illinois at Urbana Champaign

Tech Report III. Technology and Engineering Development (TED) Building. Thomas Jefferson National Accelerator Facility.

Best Practices for Applied Rooftop ` Systems, Applications and. Jerry Cohen President Jacco & Assoc. Installation

Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems

Best Practices for Applied Rooftop ` Systems - Application and. Jerry Cohen President Jacco & Assoc. Installation

On Balance: Heat Rejection Control a Packaged Solution

Engineers and Contractors - Innovative Technologies to Achieve Highest GeoExchange System Efficiencies for Commercial Projects

The Ad-Hoc Passive House. Paul W Panish

MEASURED PERFORMANCE DATA FOR

Enhance Facility Energy Management at Naval Expeditionary Base Camp Lemonnier, Djibouti. 12 May 2011

Mechanical Technical Report 3. Mechanical Systems Existing Conditions Evaluation

Integrated Building Environmental Design Case Study: Beijing Parkview Green

Site Evaluation. for. Oregon School for the Deaf. 999 Locust Street Northeast Salem, OR BE15178

MT. AIRY MIDDLE SCHOOL CARROLL COUNTY PUBLIC SCHOOLS

Heating and Hot Water

Better Buildings By Design 2013 Building the Renewable Energy Ready Home Solar Thermal Lessons Learned and Results

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

Increase your flexibility.

Thermal equalization is the obvious answer to the situation. But, how is "thermal equalization" achieved?

Technical Assignment 3

SELECTED TOPICS IN HIGH RISE MECHANICAL DESIGN

Building Science Principles for Managing Moisture in Tight Buildings

DIGI-VAV APPLICATIONS

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

Alexander Hosko Final Thesis Report April 7, 2011

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee

1. Packaged Variable Air Volume (VAV) Rooftop Units (RTU) with Hot Water Reheat. 2. Geothermal Heat Pump VAV Rooftop Units with Hot Water Reheat

WLAC Facilities Committee Meeting. May 15, 2017

Special Topics on Residential HVAC

7. MECHANICAL SYSTEM DESIGN

b.) Technical Information:

Heat Pump Water Heater Technology Development. EEBA High Performance Home Summit Ed Vineyard Oak Ridge National Laboratory

Split Type System. Air to Water Heat Pump

HVAC Mandatory Provisions Part II, Page 1

Designing Energy Efficient Outdoor Air Systems

Terminal. Las Vegas, NV. Technical

HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS

Performance Rating of Variable Refrigerant Flow (VRF) Multi-split Air-conditioning and Heat Pump Equipment

Technical Report Three

Zero Net Energy Retrofit Projects The Domes Final Performance Assessment & Verification

Transcription:

The Ed Roberts Campus Berkeley, CA Anderson Clemenceau Mechanical Option Penn State A.E. Senior Thesis April 14, 2015 Leddy Maytum Stacy Architects, Photo by Tim Griffith

ASHRAE Climate Zone 3C 99.6% Heating DB: 37 F 0.4% Cooling DB: 81.8 F MCWB: 65 F Google Maps Leddy Maytum Stacy Architects

Cooling and Heating 100% OA System Radiant Floor

Cooling and Heating 100% OA System Radiant Floor Water Source Heat Pump System With 100% Outdoor Air 2 Gas-fired Boilers Provide Hot Water 900 MBH (Each) 98% Efficiency 2 Cooling Towers Provide Chilled Water 100 Ton Capacity (Each)

Cooling and Heating 100% OA System Radiant Floor Water Source Heat Pump System With 100% Outdoor Air 2 Gas-fired Boilers Provide Hot Water 900 MBH (Each) 98% Efficiency 2 Cooling Towers Provide Chilled Water 100 Ton Capacity (Each) 5 Air Handling Units 3 Constant Air Volume Units 2 Variable Air Volume Units Paired with Exhaust Fans Water Source Heat Pumps Total of 63 Units Range of Capacity: 0.75 3.25 tons COP: 4.1 4.4 EER: 13.7-16.0

Cooling and Heating 100% OA System Radiant Floor Water Source Heat Pump System With 100% Outdoor Air 2 Gas-fired Boilers Provide Hot Water 900 MBH (Each) 98% Efficiency 2 Cooling Towers Provide Chilled Water 100 Ton Capacity (Each) 5 Air Handling Units 3 Constant Air Volume Units 2 Variable Air Volume Units Paired with Exhaust Fans Water Source Heat Pumps Total of 63 Units Range of Capacity: 0.75 3.25 tons COP: 4.1 4.4 EER: 13.7-16.0 Radiant Floor Leddy Maytum Stacy Architects

Cooling and Heating 100% OA System Radiant Floor Water Source Heat Pump System With 100% Outdoor Air 2 Gas-fired Boilers Provide Hot Water 900 MBH (Each) 98% Efficiency 2 Cooling Towers Provide Chilled Water 100 Ton Capacity (Each) 5 Air Handling Units 3 Constant Air Volume Units 2 Variable Air Volume Units Paired with Exhaust Fans Water Source Heat Pumps Total of 63 Units Range of Capacity: 0.75 3.25 tons COP: 4.1 4.4 EER: 13.7-16.0 Radiant Floor Heating and Cooling Capacity Serves Lobby and Courtyard Areas 7,150 sq. ft. Zone 1 Zone 2 Area Served Courtyard North Courtyard South Coverage Area (sqft) Cooling Cap. (MBH) Heating Cap. (MBH) 1800 27 18 2000 30 20 Zone 3 Lobby 3350 58 30

Cooling and Heating 100% OA System Radiant Floor Trace 700 Model vs. Real Building Modeled Energy Use ~30% Less Electricity Use ~30% More Gas Use Building Capacity Cooling 146 Tons 200 Tons Heating 2,200 MBH 1800 MBH

Cooling and Heating 100% OA System Radiant Floor Trace 700 Model vs. Real Building Modeled Building Capacity Cooling 146 Tons 200 Tons Heating 2,200 MBH 1800 MBH kwh 60000 50000 40000 30000 20000 10000 0 2,500.0 Energy Use by HVAC Equipment Type Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Cooling Tower Tower Fans Ceiling Pumps Fans Boiler -Natural Gas Use Energy Use ~30% Less Electricity Use ~30% More Gas Use Therms 2,000.0 1,500.0 1,000.0 500.0 - Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Energy Use by HVAC Equipment Type Cooling and Heating 100% OA System Radiant Floor Trace 700 Model vs. Real Building Modeled Building Capacity Cooling 146 Tons 200 Tons Heating 2,200 MBH 1800 MBH kwh 60000 50000 40000 30000 20000 10000 0 2,500.0 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Cooling Tower Tower Fans Ceiling Pumps Fans Boiler -Natural Gas Use Electricity Consumption [kwh] 90,000 80,000 70,000 60,000 50,000 40,000 30,000 20,000 Electricity Use Trace Model Existing Building Energy Use ~30% Less Electricity Use ~30% More Gas Use Therms 2,000.0 1,500.0 1,000.0 10,000-500.0 - Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Variable Refrigerant Flow System Unit Sizing Solar Thermal Radiant Floor and System Sizing

Variable Refrigerant Flow System Unit Sizing Solar Thermal Radiant Floor and System Sizing VRF Heat Recovery System Air-cooled Condenser (Outdoor) Unit Variable-Speed Scroll Compressor Simultaneous Cooling And Heating Heat Recovery Between Indoor Units c c Ceiling-Mounted, Ducted Indoor Units 6,000-48,000 Btu/h Capacities.32 in wgstatic Pressure Johnson Controls c Johnson Controls

VRF Mechanical Zoning Plan Variable Refrigerant Flow System Unit Sizing Solar Thermal Radiant Floor and System Sizing Nominal Size of Outdoor Unit [tons] IEER COP VRF Zone 1 26 (10+10+6) 18.8 3.56 VRF Zone 2 22 (10+6+6) 18.8 3.61 VRF Zone 3 18 (6+6+6) 19.2 3.49 VRF Zone 4 28 (8+8+6+6) 21.2 3.87 First Floor Leddy Maytum Stacy Architects Second Floor Leddy Maytum Stacy Architects

Variable Refrigerant Flow System Unit Sizing Solar Thermal Radiant Floor and System Sizing Dedicated Outside Air System (DOAS) Supplies Filtered, Dehumidified Ventilation Air Variable-Speed Fan Operation DX Cooling, Electric Heating Required Airflow [cfm] Model DOAS Unit Nominal Airflow [cfm] VRF Zone 1 4,426.47 JDHA-210 2250-5500 VRF Zone 2 5,480.2 JDHA-300 3750-8700 VRF Zone 3 3,808.54 JDHA-210 2250-5500 VRF Zone 4 5,867.72 JDHA-300 3750-8700 Lobby/Reception 2,503.64 JDHA-120 1500-3550

Variable Refrigerant Flow System Unit Sizing Solar Thermal Radiant Floor and System Sizing Utility Cost [$] 20,000 18,000 16,000 14,000 12,000 10,000 8,000 6,000 4,000 2,000 - Utility Costs: WSHP vs. VRF Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec WSHP VRF % Change in Utility Cost - WSHP vs. VRF Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 8.86% 5.55% -2.40% -13.90%-17.26%-26.34%-30.78%-26.67%-28.40%-18.22% -5.59% 6.78% Yearly Utility Cost Change: 14.3% Yearly Savings: $23,200

Life Cycle Cost Analysis Variable Refrigerant Flow System Unit Sizing 2014 Supplement to NIST Manual 135 Discount Rate: 3% Existing System Energy Costs VRF Energy Costs Net Savings Investment Discounted Payback Period $4,336,036.32 $3,718,476.30 $617,560.02 $364,300.00 20 Years Solar Thermal Radiant Floor and System Sizing

Variable Refrigerant Flow System Unit Sizing Solar Thermal Radiant Floor and System Sizing Solar Thermal Water Heating System Domestic Water Heating Radiant Floor Space Heating Analysis: CombiSys Solar Thermal Water Heating Simulation Solar Thermal Schematic

Variable Refrigerant Flow System Unit Sizing Solar Thermal Radiant Floor and System Sizing Solar Thermal Water Heating System Domestic Water Heating Radiant Floor Space Heating Analysis: CombiSys Solar Thermal Water Heating Simulation Model Inputs: Collector Area: 90 m 2 (970 ft 2 ) Collector Performance Characteristics: η 0 =0.687, a 1 =1.505 [W/m 2 -K], a 2 =0.011 [W/m 2 -K] Dom. Hot Water Load: 3 gal/d per occupant, 50 occupants Space Loss Coefficient: 500 W/K (~1700 Btu/h/ F)

Comparison of Collector Angles 100.00 Variable Refrigerant Flow System Unit Sizing Solar Thermal Radiant Floor and System Sizing Solar Thermal Water Heating System Domestic Water Heating Radiant Floor Space Heating Analysis: CombiSys Solar Thermal Water Heating Simulation Model Inputs: Collector Area: 90 m 2 (970 ft 2 ) Collector Performance Characteristics: η 0 =0.687, a 1 =1.505 [W/m 2 -K], a 2 =0.011 [W/m 2 -K] Dom. Hot Water Load: 3 gal/d per occupant, 50 occupants Space Loss Coefficient: 500 W/K (~1700 Btu/h/ F) Solar Fraction (%) 95.00 90.00 85.00 80.00 75.00 70.00 65.00 60.00 55.00 50.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 12.00 Month 47 Degree 37 Degree 27 Degree Gross Roof Area: ~2,500 sq. ft.

Variable Refrigerant Flow System Unit Sizing Solar Thermal Radiant Floor and System Sizing CombiSysSolar Thermal Simulation Model Inputs: Collector Area: 90 m 2 (970 ft 2 ) Collector Performance Characteristics: η 0 =0.687, a 1 =1.505 [W/m 2 -K], a 2 =0.011 [W/m 2 -K] Dom. Hot Water Load: 3 gal/d per occupant, 50 occupants Space Loss Coefficient: 500 W/K (~1700 Btu/h/ F) Avg. Solar Fraction 91% Avg. Collector Efficiency 24% Btu Solar Gains vs. Building Loads 20,000,000 18,000,000 16,000,000 14,000,000 12,000,000 10,000,000 8,000,000 6,000,000 4,000,000 2,000,000 - Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Space Load Useful Gain Aux Heat

Variable Refrigerant Flow System Unit Sizing Solar Thermal Radiant Floor and System Sizing CombiSysSolar Thermal Simulation Model Inputs: Collector Area: 90 m 2 (970 ft 2 ) Collector Performance Characteristics: η 0 =0.687, a 1 =1.505 [W/m 2 -K], a 2 =0.011 [W/m 2 -K] Dom. Hot Water Load: 3 gal/d per occupant, 50 occupants Space Loss Coefficient: 500 W/K (~1700 Btu/h/ F) Btu 100,000.00 90,000.00 80,000.00 70,000.00 60,000.00 50,000.00 40,000.00 30,000.00 20,000.00 10,000.00 - Solar Gains vs. Building Loads 1 2 3 4 5 Space Load Useful Gains Aux Heat

Life Cycle Cost Analysis Variable Refrigerant Flow System Unit Sizing Yearly Cost Savings Net Savings Investment Discounted Payback Period Solar Thermal Radiant Floor and System Sizing $3,058.63 $80,074.93 ~$75,000 25+ Years

Variable Refrigerant Flow System Unit Sizing Solar Thermal Radiant Floor and System Sizing Btu Alternative Application: Domestic Hot Water Only Peak 1-Hour Demand of 150 gal Constant, Year-Round Load 3,500,000 3,000,000 2,500,000 2,000,000 1,500,000 1,000,000 500,000 - Load vs.useful Gains 100.0 90.0 80.0 70.0 60.0 50.0 40.0 30.0 20.0 10.0 - Solar Fraction (%) Load Solar Gains Solar Fraction Solar Fraction Collector Efficiency Yearly Cost Savings Investment Payback Period 96% 23% $2,016 ~$25,000 18 Years

Roof Structure Redesign Current Structure New Design Criteria Results Current Roof Structure Structural Steel Framing 18 Gage VercoW3 Metal Decking 3-1/2 LW Concrete Topping Current Roof Structure Max UnshoredClear Span: 15-7 @3-Span Allowable Superimposed Load for 11-0 Span Condition: 207 psf Typical Framing Plan for South East Roof: 3 Spans@10-8 Verco Decking, Inc.

Roof Structure Redesign Current Structure New Design Criteria Results Current Roof Structure Structural Steel Framing 18 Gage VercoW3 Metal Decking 3-1/2 LW Concrete Topping Solar Panel Array for and Space Heating Vulcraft Deck Manuals 3VLI Composite Deck, LW Concrete Topping 19 Gage, 2 Topping Self-Weight: 35 psf Maximum SLL @10-8 Spans: 105 psf 30 Panels at 225 lb/panel Vertical Pull Force Due To Wind: ~610 lb Panel Area on Roof: 1,100 sqft. Arup, San Francisco Total Additional Load: ~55 psf

Variable Refrigerant Flow System First Cost: $364,300 Yearly Energy Savings: $23,200 Payback Period: 20 Years : Not Recommended For A Complete Renovation Could Be Considered For New Construction Solar Thermal Water Heating System Two Options: Space Heating and First Cost: $75,000 Payback: 25+ Years Only First Cost: $25,000 Payback: 18 Years : Not Recommended Could More Economical In Different Climate Conditions