Information Job Sheet 4. Closed-Loop Drainback Systems. Drainback tanks

Similar documents
Information Job Sheet. Trainer Familiarization and Safety

EDS Solar Thermal ( )

Solar water heating system

The. Steam ONE-PIPE STEAM SYSTEMS

Shell-and-Tube Heat Exchanger (Four Passes) - Optional

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring

1 Exam Prep Solar Water and Pool Heating Manual (UCF) Questions and Answers (Plumbing Contractor)

CodeNotes. Solar Water Heating Systems Based on the 2018 International Solar Energy Provisions (ISEP ) Introduction OFFICIAL

Job Sheet 1. Geothermal Energy OBJECTIVES. Familiarization with the training system components PROCEDURE

Geothermal Training System

BEFORE OPERATING THE MACHINE: WARNING

Solar Water Heaters. Bastián Acevedo Bustos. Electronic Engineering Student, Tarapacá University. Environmental Studies Student, York University

SEALED THERMAL STORE

CodeNotes. Solar Water Heating Systems Based on the 2015 International Solar Energy Provisions. Introduction. Solar Water Heating System Designs

Wood Boiler Plumbing Schematics

Geothermal Training System (46126-A0)

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

Exercise 2-4. Heat Exchangers (Optional Exercise) EXERCISE OBJECTIVE DISCUSSION OUTLINE. Description of a brazed plate heat exchanger DISCUSSION

Installation & Operation Manual Models: TSU

Solar heating systems

INSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC

ART TEC Solar Differential Temperature Controller DTC-1 Manual

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL

CRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING ANSWER SCHEDULE

P/N CC-100. Coolant Circulator. Operation manual

Explorer CleaningPartsDirect.com Carpet Extractor. Operator and Parts Manual. Home Find... Go To.. Model No.: Can.

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

V80-H Multistage Pump Instruction Manual

Lubrication Tools and Equipment Portable Oil Drains

DHW Tanks Indirect Tanks for Domestic Hot Water. New! Single coil tanks with electric element

Solar Thermal Planning Worksheet Date: / /

HW 22 District heating substation for indirect heating and domestic hot water systems

Conical Fermenter. Instructions

INSTALLATION & TESTING MANUAL

Installation & Operation Manual Models: SIT030, SIT040, SIT050, SIT065, SIT080, & SIT119

The Refrigeration Cycle

INSTALLATION & TESTING MANUAL

INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER

The Refrigeration Cycle

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

Series 1140 and 1141 Temperature Regulators

Used Fluid Handling Portable Used-Oil Gravity Drains

Diplomat Inverter/Diplomat Duo Inverter

Akva Lux VX District heating substation for indirect heating and domestic hot water systems

pod Installation, Operation & Maintenance viridian Pod-PV, Pod-ST solar v

8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN.

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

Portable Air-conditioner

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Components for solar heating systems

Understanding Solar Types

TOYOTA FJ-40 DIRECTIONS

oventrop OVSOL 5 Evacuated Tube Collector Regusol 130 EL Solar Domestic Hot Water Heating System

DOUBLE O-RING GEO-PRIME TANK Non-Pressurized Flow Center System INSTALLATION INSTRUCTIONS. Model: DORGPT-1 NOTE:

Used Fluid Handling Portable Used Oil Gravity Drains

User s Information Manual

INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER

GOLD Plus 30/40/60/80

Indirect Fired Water Heaters

DC INVERTER AIR TO WATER HEAT PUMP AC series Heating & Cooling series CX45

Portable Air-conditioner Use and Care Manual

Installation Instructions

ASSEMBLY INSTRUCTIONS FOR THE PUMP AND CONTROL UNIT ZPS 18a-01

SUN EQUINOX HEATING SYSTEMS

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

Heaters and Defrosters

R.A.S.E.R.S System. Installation Guide

Installation & Operation Manual Models: SIT030 - SIT119

WORKSHEET 4-4 (ON-CAR) HFC-134a Recovery

Section 2: Solar Water Heating Systems focuses primarily on the common solar system design types.

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

User instructions DHP-AT

INSTALLATION INSTRUCTIONS

EZ CLEAN IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. External Aquarium Filter

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

WRAS TEST & ACCEPTANCE CRITERIA Issue No: 1 Date of issue: October Sheet 1 of 7

Atmos EasySolar. Installation Instructions for. Sloping roof and flat roof installation with evacuated tube collector

Solar Controller Training Presentation

VADA - Rain2Main Automatic Rainwater Controller

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS

INSTALLATION & OPERATION MANUAL

INDIRECT SYSTEM FOR FROST LOCATIONS

* * English. Operator Manual. Carpet Cleaner Rev. 01 ( ) Model V

INVERTER SPLIT - TYPE

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

Installation, operation and care. Pellmax UB. Burner not included Replaces:

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

THERMflow Thermal Store Cylinders

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

USER S INFORMATION MANUAL

SEA FROST SHORE ASSIST SA-1 R-12 THIS MANUAL IS SUPPLEMENTAL TO THE SEA FROST R-12 ENGINE DRIVE MANUAL INSTALLATION INSTRUCTIONS

Transcription:

Information Job Sheet 4 Closed-Loop Drainback Systems Drainback systems can consist of two closed-loop circuits. Each loop contains an active pump to circulate the solar and storage fluids independently. These systems can be used for heating water and space (air and/or surfaces). When solar energy is available, the contents of a small storage tank, called a drainback tank are heated by the primary system loop. When the tank reaches the differential controller s temperature setting, the circulator pump is turned off, and the water in the solar collector array drains backwards through the system into the drainback tank. For this reason, a check should not be installed in a drainback system loop. The system is simplified further by its low-pressure operation. An external heat exchanger (or an integrated one inside the tank), extracts heat from the drainback tank, as a secondary system loop pumps the heated fluid into a solar storage tank or a space heating element, such as a hydronic radiator or radiant flooring. The drainback tank must be installed below the collector and plumbing must be angled downward from the top of the collector to let gravity drain the fluid without any pump assistance. The pipes must also be well supported to minimize any sagging. A vacuum breaker must be installed at the top outlet of the solar collector to automatically permit air to enter the collector panel as it drains. This action prevents any potentially high vacuum from collapsing the collector panel, and also allows the collector to empty its contents completely. A high-head pump is often required to push the solar fluid upwards, back to the top of the collector, whenever the system turns on. Certain solar collectors cannot be used with drainback systems, such as flatplate collectors with serpentine riser tubes and some evacuated-tube collectors. Drainback tanks Drainback systems include a separate tank (in addition to a storage tank), called a drainback tank. As shown in Figure 18, this tank is often smaller and is specifically intended to store the drained fluid from the solar collector array. Festo Didactic 52669-20 41

Solar collector Drainback tank Storage tank Heat exchanger Figure 18. Basic drainback system with external heat exchanger. As shown in Figure 19, drainback tanks can have integrated heat exchanger coils, either internal to the tank or externally wrapped around the tank. Also, the thermal storage can be configured with multiple storage tanks. Solar collector Heat exchanger Storage tank Drainback tank Figure 19. Basic drainback system with integrated heat exchanger. 42 Festo Didactic 52669-20

The drainback tank is a thermally insulated, unvented vessel that often contains a sight glass (sight gauge) to visually monitor the fluid level within the tank. When commissioning a drainback system, the drainback tank must only be filled partially, well below the tank s maximum capacity. Sizing the tank requires a simple determination of liquid volume within the solar collector array, including all piping that exists above the drainback tank level. Then, add 15.14 L for extra margin. Another rule-of-thumb is to simply double the solar fluid loop volume. Common tank sizes range from 18.93 to 113.56 L in 18.93 L increments. Standard electric water heaters range in size from 113.56 to 454.25 L, and may be used as large drainback tanks. Larger custom tanks are also available from 378.54 to 7 570.82 L. A pressure relief is often installed on the drainback tank, and is usually set for 344.74 kpa. In the solar thermal training system, the storage tank is used as the drainback tank and a secondary storage tank is assumed. Drainback pumps selection is critical for a drainback system to function properly. ACpowered, high-head, low-flow pumps are required to move the solar fluid back up to the solar collectors from the bottom of the drainback tank. The head for the pump is determined by adding four feet to the vertical distance between the bottom of the drainback tank and the uppermost part of the solar collector array. The extra margin helps to ensure that friction head is overcome. System performance This job sheet involves installing and operating a dual closed-loop water (DHW) and space (floor or air) drainback system with thermal storage, which has the following advantages and disadvantages. System type Active, indirect, closed-loop, unvented, water (DHW) and space (floor or air) heating with storage. Advantages Efficient operation Simple configuration reduces cost and lowers maintenance Overheat-protection turns off pump when high temperature is reached Can use water or sand for thermal storage Limited freeze-protection provided without antifreeze If used, antifreeze life is extended (compared to pressurized systems) Festo Didactic 52669-20 43

Disadvantages Can freeze over extended cold periods, not for extremely cold climates Additional tank or special tank needed High-head pump needed Collector array must be placed near and above storage tank Drainback tank must be placed below collector array and above storage tank Only certain solar collectors that drain properly can be used Collector piping must be sloped at least 1, and cannot sag Careful planning and installation is needed 44 Festo Didactic 52669-20

Job Sheet 4 Closed-Loop Drainback Systems OBJECTIVE In this job sheet, you will install a dual closed-loop water (DHW) and space (floor or air) drainback system that includes thermal storage and can use antifreeze as part of a solar thermal energy system. Four different solar heating systems can be installed. Three of these drainback systems use internal heat exchangers that are an integral part of the drainback tank: one for heating water, one for heating water and flooring, or one for heating water and space. A fourth example of a drainback system uses an external heat exchanger to heat water. PROCEDURE Equipment required Refer to the Equipment Utilization Chart in Appendix A to obtain the list of equipment required for this job sheet. Safety procedures Before proceeding with this job sheet, complete the following checklist. You are wearing safety glasses. You are wearing safety shoes. You are not wearing anything that might get caught such as a tie, jewelry, or loose clothes. If your hair is long, tie it out of the way. The working area is clean and free of oil. The floor is not wet. Your sleeves are rolled up. The wheels of the system are locked in place. Festo Didactic 52669-20 45

Installation 1. Figure 20 through Figure 23 show indirect solar heating systems with thermal storage for heating water and/or air. Choose one of those systems, then continue this procedure using the selected system. Pressurerelief Hot water outlet (DHW to taps) Shutoff Expansion tank Vacuum breaker COL TST Heat exchangers Solar collector TRF Storage tank Cold water inlet (WS) Storage tank Differential controller Shutoff Fill bowl Funnel Figure 20. Closed-loop, water-heating drainback (storage) system schematic. 46 Festo Didactic 52669-20

Vacuum breaker Hot water outlet (to storage tank) COL TST Heat exchangers Solar collector Storage tank Cold water inlet (from storage tank) TRF Differential controller Pressurerelief Shutoff Warm surface Expansion tank Radiant floor Shutoff Fill bowl Funnel Figure 21. Closed-loop, water/floor-heating drainback (storage) system schematic. Festo Didactic 52669-20 47

Vacuum breaker Hot water outlet (to storage tank) COL TST Heat exchangers Solar collector Storage tank Cold water inlet (from storage tank) TRF Differential controller Cold air inlet (AS) Fan Radiator Warm air outlet Pressurerelief Fill bowl Funnel Expansion tank Shutoff Power input (ES) Shutoff Figure 22. Closed-loop, water/air-heating drainback (storage) system schematic. 48 Festo Didactic 52669-20

Vacuum breaker COL TST Heat exchangers Solar collector TRF Heat exchanger Storage tank Differential controller Hot water outlet (DHW to taps) Fill bowl Pressurerelief Funnel Expansion tank Shutoff Shutoff Storage tank Cold water inlet (WS) Figure 23. Closed-loop, water-heating drainback (storage) system schematic with external heat exchanger. Festo Didactic 52669-20 49

2. Ensure that the following parts are mounted on the mobile workstation as shown in Figure 24 to Figure 27. Solar collector Circulator pumps (2) Storage tank (used as drainback tank) Plate heat exchanger Differential controller (with 3 sensors) Thermostat controller (with 1 sensor) Expansion tank (1) Radiator Radiant floor Thermometers (2) Rotameters (2) Pressure gauge Pressure relief (1) Vacuum breaker Shutoff s (2) Fill bowl (1) Electrical panel 50 Festo Didactic 52669-20

Primary loop Hot flow Cold return Warm path Secondary loop Hot flow Cold return Warm path Figure 24. Closed-loop, water-heating drainback (storage) system configuration. Festo Didactic 52669-20 51

Primary loop Hot flow Cold return Warm path Secondary loop Hot flow Cold return Warm path Figure 25. Closed-loop, water/floor-heating drainback (storage) system configuration. 52 Festo Didactic 52669-20

Primary loop Hot flow Cold return Warm path Secondary loop Hot flow Cold return Warm path Figure 26. Closed-loop, water/air-heating drainback (storage) system configuration. Festo Didactic 52669-20 53

Primary loop Hot flow Cold return Warm path Secondary loop Hot flow Cold return Warm path Figure 27. Closed-loop, water-heating drainback (storage) system configuration with external heat exchanger. 3. Ensure that the electrical wiring is complete by referring to the electrical wiring instructions in Appendix F. 4. Adjust the solar collector tilt angle for 50 to ensure that the collector is above the drainback tank water level. Be careful when rotating the solar collector. Improper use can lead to injuries. 5. Connect the necessary hoses as shown in Figure 20 and Figure 24 (or Figure 21 and Figure 25, or Figure 22 and Figure 26, or Figure 23 and Figure 27). a Always use the minimum hose length required for each circuit connection. 6. Connect the training system to an ac power source. 54 Festo Didactic 52669-20

7. Partially fill the system with water by performing the System filling procedure in Appendix C, while adhering to the following note: a Do not fill the drainback tank completely. Fill the tank to a depth of about 22.2 cm (measured at tank center). Be careful to prevent water from being in contact with electrical components. Use a bucket and mop if some leakage occurs. 8. Turn the power on by setting the circuit breaker to I. 9. Start the pumps by setting both override switches to Override. Then, set the pumps to III. 10. Evacuate the air present in the system using the priming procedure (refer to Appendix C). Commissioning 11. Set the s as shown in Table 7. Table 7. State of the different s. Valves States Fill bowl ball Solar collector ball Storage tank ball Shutoff s (2) closed open open open a Make sure the solar collector outlet hose (91.44 cm long) is connected directly to the top (return port) of the drainback tank, with no sagging. Also, ensure that the vacuum breaker is installed. 12. Turn the pumps on by setting both override switches to the Controller position. 13. If installed, turn on the radiator and set the fan to minimum speed (Switch settings: S1 = 2, S2 = ). Festo Didactic 52669-20 55

14. Use the differential controller (TDIC) to set the pump to AUTO mode. To do so, press and hold the + (right) button on the controller until a new menu appears. Then, use the + button to select the MAN-1 menu. Press the OK (center) button and use the + and - buttons to select the AUTO mode. Press the OK (center) button to confirm. 15. Use the thermostat controller (TH) to adjust the set-point temperature between 3 C to 6 C above the ambient temperature by using a rotating knob. Ambient temperature C Set-point temperature C 16. Measure (with the pump on) the different parameters listed in Table 8, then record the values in the Initial column of the table. After that, position and power up the two 500 W work lights so that most of the radiant energy floods the solar collector panel evenly. a a a The pressure gauge port must be vertically level with the rotameter pressure port. If the rotameter does not indicate any flow, it means that the controller has turned the pump off. Use the magnetic surface thermometer to measure ambient air temperature in front of the radiator output. The solar thermal training system should be operated under supervision at all times. Never let the system operate unattended. The surface of the work lights can become very hot. Whenever you manipulate them, take great care to avoid direct contact with the skin. 56 Festo Didactic 52669-20

Table 8. Test results. Values for different measuring times Device Initial At 15 min At 30 min Units F1-1 (flow rate) L/min PI-1 (pressure) kpa F1-2 (flow rate) L/min PI-2 (Pressure) kpa TI (collector input) C TI (collector output) C TE-S1 (COIL) C TE-S2 (TST) C TE-S4 (TRF) C Floor temperature C Air temperature C 17. After about 15 minutes, measure (with the pump on) the different parameters listed in Table 8, then record the values in the At 15 min column of the table. 18. After about 30 minutes, measure (with the pump on) the different parameters listed in Table 8, then record the values in the At 30 min column of the table. 19. Use the differential controller override switch to turn the primary pump off. 20. Use the thermostat controller override switch to turn the secondary pump off. 21. Turn off the work lights. Festo Didactic 52669-20 57

22. Measure and record the water levels in the storage tank (being used as a drainback tank) with the primary pump turned on and turned off. Measure the water depth at the tank center. See Figure 28. a Wait at least 30 seconds with the pump off while draining ends. on: cm off: cm Figure 28. Drainback (storage) tank water level. 23. Turn off the system and the radiator by setting the circuit breaker to O. 24. Disconnect the power cords and drain the system by performing the System draining procedure in Appendix C. 58 Festo Didactic 52669-20

25. Use the data in Table 9 to determine the total volume of water that is contained in the solar collector and all tubing that is situated above the drainback tank water level. Do not include the volume listed for the storage tank. Table 9. System component volume. Item Description Volume (L) 87042-10 1.82 m long hose with 1.27 cm inner diameter 0.23 87042-11 91.44 cm long hose with 1.27 cm inner diameter 0.12 87042-12 60.96 cm long hose with 1.27 cm inner diameter 0.08 87042-13 30.48 cm long hose with 1.27 cm inner diameter 0.04 89515 Solar collector 0.6 46508-1C Circulator pump 0.20 87318-10 Storage tank 51.1 L (37.85 L max.) 37.85 87318-10 Coil heat exchanger 0.30 46505 Plate heat exchanger 0.11 L (x2) 0.11 46509 Temperature sensor (RTD) 0.03 52181 Thermostat controller (sensor) 0.05 46510-10 Expansion tank 7.95 L (4.16 L max.) 0.05 6531-C0 Radiator 0.26 46512 Radiant floor 0.16 46501 Thermometer 0.04 6550-A0 Rotameter 0.09 6553-E0 Pressure gauge (60.96 cm long hose with 0.46 cm inner diameter) 0.01 46503 or 46504 Pressure relief 0.06 6520-A0 Shutoff 0.04 46507 Check assembly 0.12 46519-10 Fill bowl 0.05 46511 Automatic air vent 0.05 a a The thermostat controller (52181) is part of the workstation (46500-2C). Each system component volume (in liters) includes the connection ports. Festo Didactic 52669-20 59

26. Based upon the estimation, how much water should drain into the drainback tank? L 27. Calculate and record the difference in water levels (height in cm) that you measured in the drainback tank with the primary pump turned on and turned off. cm 28. Calculate the volumetric difference (volume in L) between the two drainback tank conditions using the equation below. b Use the inside dimensions of the drainback tank, or approximately 50.8 cm x 31.12 cm. Volume Length Width Height 3 1000 cm / l 29. Based upon the results, how much water is draining from the solar collector into the drainback tank? L 30. Is this observed value similar to the estimated value (within 10%)? Yes No 31. Ask the instructor to check your work. PROCEDURE QUESTIONS 1. Did the system work correctly? Yes No 2. Describe and briefly explain the system behavior. 60 Festo Didactic 52669-20

3. Name at least two locations or devices in the system where thermal energy was transferred through a containment wall. 4. Where might a similar system prove to be effective or useful? 5. Was the drainback tank water level lower when the primary pump was running (on)? Yes No 6. Based upon the measured values, what was the overall temperature rise of the water? 7. Based upon the measured values, what was the overall temperature rise of the floor or air? Name: Date: Instructor's approval: Festo Didactic 52669-20 61