Optical imaging using coherent anti-stokes Raman scattering and other nonlinear mechanisms

Similar documents
Towards CARS Endoscopy

Ecotoxicological assessment of nanoparticle-containing acrylic copolymer dispersions in fairy shrimp and zebrafish embryos

Compact Raman spectrometer system for low frequency spectroscopy

Current Research Topics in Optical Sensors and Laser Diagnostics

Differential femtosecond coherent Stokes and anti-stokes Raman. spectroscopy

Laser Diagnostics and Optical Measurement Techniques

Low-Frequency Raman Spectroscopy Enabling Affordable Access to the Terahertz Regime

Picosecond anti-stokes generation in a photonic-crystal fiber for interferometric CARS microscopy

Contrast enhancement using silica microspheres in coherent anti-stokes Raman spectroscopic imaging

SPECTRAL INSTRUMENTATION

RAMAN SCATTERING AND OTDR BASED DISTRIBUTED SENSOR FOR TEMPERATURE MONITORING APPLICATIONS

Design of a high accuracy non-dispersive Infrared gas sensor for continuous emission monitoring of carbon monoxide emitted from an industrial stack

Communications. Sensing. Instrumentation. Delivering tomorrow s optical and photonic solutions today. BREAKTHROUGH PHOTONIC PRODUCTS

WHITE PAPER FIBER OPTIC SENSING. Summary. Index. Introduction. About Fischer Connectors

Multitel develops components and full instruments for in-vitro and in-vivo diagnostics in the biomedical, food and drug sectors.

Propagation loss in optical fibers (01/29/2016)

The FEL Facility Optical Diagnostics and FEL Characterization

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

Chemistry Instrumental Analysis Lecture 4. Chem 4631

Chemistry Instrumental Analysis Lecture 14. Chem 4631

Stimulated Raman Scattering Microscopy with a Robust Fibre Laser Source

Application of Golay Coded Pulse Compression in Air-coupled Ultrasonic Testing of Flexible Package Seal Defect

Mark Farries. Gooch & Housego

EXTENDING RAMAN INTO THE THz REGIME

Long-distance remote simultaneous measurement of strain and temperature based on a Raman fiber laser with a single FBG embedded in a quartz plate

FiberSystem. Fiber Optic Linear Heat Detection for Special Hazard Applications

Stand-off Detection of Trace Explosives by Infrared Photothermal Imaging. Trace Contamination

FLIM/FFS and Nanoimaging Upgrade of Olympus confocal microscopes

Optical Time Domain Reflectometry (OTDR)

Journal of Applied Science and Agriculture. Improve the Spatial resolution of distributed optical sensors by designing a new detection scheme

University of California Santa Barbara Department of Chemistry and Biochemistry Optical Characterization Facility. Safe operations manual

High Sensitivity Explosives Detection using Dual-Excitation- Wavelength Resonance-Raman Detector

Recent Advances in Solid State Lasers and Nonlinear Optics for Remote Sensing

Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE

New optical frequency domain differential mode delay measurement method for a multimode optical fiber

Publication American Institute of Physics. Reprinted with permission.

Distributed Temperature Sensing

Questionnaire on activities in radiometry and photometry. Reply from: Korea Research Institute of Standards and Science (KRISS)

FPI Detectors Pyroelectric Detectors with Spectrometer Functionality

From THz to X-ray - Inventing the Future. Progress in NIR spectroscopy and its industrial applications

DETECTION AND LOCALIZATION OF MICRO AND MULTIPHASE LEAKAGES USING DISTRIBUTED FIBER OPTIC SENSING

An FT-NIR Primer. NR800-A-006

RAMAN SPECTROSCOPY See more, faster than ever before

Application Note. Which characterization method is best for your application? The Future of Thermal Imaging is Here!!!

scale analysis to micro scale imaging-ftir. State of the art and future perspectives.

Separation of the Pyro- and Piezoelectric Response of Electroactive Polymers for Sensor Applications

Intrusion Detection System based on Speckle Pattern change in Fiber Optic Sensors...Abdulkareem H. Dagher, Shehab A kadhim, Hawraa H.

Interferometric optical time-domain reflectometry for distributed optical-fiber sensing

INTERNATIONAL JOURNAL OF RESEARCH GRANTHAALAYAH A knowledge Repository

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

Distributed Rayleigh scatter dynamic strain sensing above the scan rate with optical frequency domain reflectometry

Compact Portable QEPAS Multi-gas Sensor

OFDR-Temperature Sensing using Existing Fiber-Optic Communication Cables An Application for Automatic Fire Detection?

Electro Optical Components, Inc Skylane Boulevard, Santa Rosa, CA Toll Free: 855-EOC

Microscopy from Carl Zeiss

quantum cascade lasers (EC-QCL)

Fli'l HEWLETT. Measurement of Raylelgh Backscattering at 1.55 urn with a 32 um Spatial Resolution

Bunch Length Interferometer System

Date: Wednesday, January 31, 2018 Time: 8:30 am 5:00 pm Location: Moscone West (Room 2018, Level 2)

Leakage detection using fiber optics distributed temperature monitoring

Autonomous Vehicles. Pushing the Boundaries of Sensors and Emitters Reader Issue Beacons of the Industry Annual Reader Poll

Development of a variable output LED-365 irradiance standard

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Development and demonstration of a diode laser sensor for a scramjet combustor

Understanding total measurement uncertainty in power meters and detectors

SOLUTION MINING RESEARCH INSTITUTE

Temperature dependent Components within the Pyroelectric Detector

DURIP: Fast Oscilloscope and Detectors for Air Laser Research

Lasers Technical Seminar at Bruno Events Center on March 27 th, Next generation of SPADs - Single Photon Avalanche Detectors

Characterization of High Speed Optical Detectors for Purpose of OM4 Fibre Qualification: Selective Mode Detection

The Optical Scattering Calibration System at SNO+ IOP 2015

Fibre Optic Sensors: basic principles and most common applications

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

E11 Tests of trace gas concentration multicomponent. monitoring system

Instruments Designed for POF & Fibre Optic Cable Testing

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

NIH Public Access Author Manuscript Opt Express. Author manuscript; available in PMC 2011 February 1.

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Company facts. ! Photoacoustic Spectroscopy (PAS) and! Fourier Transform InfraRed (FTIR) principle

Construction of a Calibration System for Power Responsivity of Optical detectors Using Different Laser Sources

WHAT IS LASER ULTRASONIC TESTING?

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Instrumentation for Beam Profiling in the Terahertz Regime

Office of Nonproliferation and Verification Research and Development University and Industry Technical Interchange (UITI2011) Review Meeting

Analisi del Focus-shift su sorgenti multikw. Luca Porcelluzzi Ophir Spiricon Europe GmbH

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

Rutgers Environmental Health and Safety (REHS)

Gas Temperature Measurements with High Temporal Resolution

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

Fiber optic distributed pressure sensor for structural monitoring applications

Range Dependent Turbulence Characterization by Co-operating Coherent Doppler Lidar with Direct Detection Lidar

OPTICAL TIME DOMAIN REFLECTOMETRY (OTDR) Dr. BC Choudhary Professor, NITTTR, Chandigarh

Technical specifications of FT-IR Spectrometer

Non-destructive testing of green sanitary ceramics by microwaves and an active thermographic technique

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011

Mid-Infrared Laser based Trace Gas Sensor Technologies: Recent Advances and Applications OUTLINE. Mar. 23, Houston, TX

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

Transcription:

Optical imaging using coherent anti-stokes Raman scattering and other nonlinear mechanisms Application notes Issue AN1012IL01 Authors Keywords: Coherent anti-stokes Raman scattering, vibrational contrast, label free imaging, nonlinear optical imaging. In this work multimodal operation of commercially available CARS microspectrometer (EKSPLA CARSCOPE) equipped with a picosecond dual wavelength laser source (EKSPLA PT259) was demonstrated for the imaging of various biological objects using coherent anti Stokes Raman scattering (CARS), two photon excited fluorescence (TPEF) and second harmonic generation (SHG) contrast mechanisms. Obtained CARS images of yeast cell and flower pollen clearly demonstrate label free and 3D imaging capabilities of CARS technique. Multi contrast images of green algae and plants containing starch demonstrate a variety of research facilities, where the method can be applied. Andrej Dementjev 1 Jūris Kiškis 1 1 Center for Physical Sciences and Technology, A. Goštauto 11, LT-01108, Vilnius, Lithuania 1. Introduction In recent decade the coherent anti-stokes Raman scattering (CARS) phenomenon has found multiple applications in microscopy as an imaging technique [1-6]. This tool enables chemically selective visualization of various objects using vibrational contrast. CARS microscopy is primarily marketed as label-free technique, where the contrast mechanism is based on intrinsic molecular vibrations. The CARS process is nonlinear light-matter interaction. Thus, similarly as two photon excited fluorescence (TPEF) it allows 3D sectioning, circumventing the need for confocal detection. Moreover, using near infrared excitation wavelengths CARS microscopy enables a probe of thick tissue up to 100 µm in depth. Detected anti-stokes signal is blue shifted with respect to the excitation wavelengths and therefore CARS signal is free from linear fluorescence. In comparison to spontaneous Raman microscopy, CARS signal is coherent and directional, with several orders of magnitude higher intensity. All mentioned advantages make this technique very attractive to imaging purposes. Fundamentals of the coherent anti-stokes Raman scattering imaging may be found in detailed reviews [7, 8]. Briefly, the CARS signal originates from the four-wave mixing process involving three laser pulses pump, probe and Stokes with frequencies p p > s, respectively. In most of implementations pump and probe frequencies coincide ( p = p ). Thus two-color light sources are used in this technique and the CARS signal is obtained at the frequency as = 2 p - s. Optical parametric oscillator (OPO) pumped by a high repetition rate ultrashort pulsed laser currently is considered as a most suitable source for CARS microscopy. It features widely tunable two-color output in near-infrared region. Using near infrared excitation wavelengths for microscopy eliminates or significantly reduces possibility of photochemical damage. The pulse duration of several picoseconds is a good compromise between high intensity and narrow spectral bandwidth necessary for the CARS microscopy [3]. Its intensity is sufficient also for observation of other nonlinear responses of the matter, e.g.: TPEF or second harmonic generation (SHG). Considering CARS microspectrometer as a multimodal platform for nonlinear optical imaging extends capabilities of equipment and helps to reveal different properties of investigated samples. In this work multimodal operation of commercially available CARS microspectrometer CARSCOPE from EKSPLA was demonstrated for the imaging of various biological objects using CARS, TPEF and SHG contrast mechanisms.

2 Optical imaging using coherent anti-stokes Raman scattering and other nonlinear mechanisms 2. Experimental setup Intensity and polarization control 1064 nm Power monitoring Revolver with filters Delay line Beam collimation Condenser optics Forward detection Detector Sample Piezo stage Picosecond tunable laser PT259 690-990 nm 50/50 mirror Detector PC Intensity and polarization control Filter Power monitoring Spatial filter Revolver with filters Inverted microscope Olympus IX71 Backward detection Revolver with filters Multifunctional PCI board Fig. 1. Block diagram of microscpectrometer CARSCOPE (EKSPLA). The block diagram of experimental setup is shown on Fig. 1. Picosecond tunable laser PT259 (EKSPLA) is used as an excitation source. Both excitation beams (Stokes and pump) are collinearly combined in main optical unit of microspectometer and directed to an inverted microscope Olympus IX71. A spatial filter was used to improve the beam profile. The excitation light was focused on the sample with an oil-immersion objective (Olympus, Plan Apochrom., 60X, NA 1.42). In the forward detection scheme the CARS signal was collected by a long working distance condenser. Long-pass and short-pass filters were used as a blocking tool for spectral separation of the CARS signal. CARS radiation was detected with the avalanche photodiode (Perkin Elmer), which was connected to a multifunctional PCI board (National Instruments Ltd.) A piezo scanning system (Physik Instrumente GmbH & Co) was used for scanning the sample. EKSPLA tunable laser PT259 consists of picosecond Nd:YVO₄ pump laser with the pulse repetition rate of 1 MHz equipped with a frequency doubling unit and traveling wave optical parametric generator (OPG) integrated into single compact housing. It features 700-2300 nm tuning range, 5 ps pulse duration and nearly Fourier transform-limited linewidth. It also contains additional port for fundamental pump laser radiation (1064 nm) access, which is specially designed for CARS application. Using this laser source, three different combinations of excitation beams coupling can be realized: OPG signal wave (700 990 nm) with fundamental wave (1064 nm), OPG idler wave (1150 2300 nm) with fundamental wave or OPG signal wave with OPG idler wave. In all cases the range of accessible vibrations is approx. 700 4000 cm ¹, which covers all most important vibrational modes. In our scheme for CARS implementation OPG signal wave was coupled with fundamental wave (1064 nm) and used as pump and Stokes excitation beams, respectively. This configuration was chosen, because it allows using simpler, commercially available microscopy optics and achieving best possible spatial resolution. Furthermore, in longer than approx. 1300 nm wavelengths water absorption increases significantly. This effect drastically reduces damage threshold of investigated biological objects. Measurements of the CARS spectra were performed by tuning OPG wavelength and changing filter sets within five different spectral ranges, enabling investigations with the typical detection rate of 5 cm ¹/s. The single frame scans of 200 200 pixels images were obtained with 2 ms pixel dwell time. Excitation pulse energies from 0.1 to 1 nj at the sample for both pump and Stokes beams were used. Scanning control, data processing and the laser wavelength tuning were controlled by a computer. TPEF and SHG signal detection was realized using the epi- and forward detection, respectively, and utilizing appropriate band-pass and interference filters.

Optical imaging using coherent anti-stokes Raman scattering and other nonlinear mechanisms 3 3. Results and Discussion 3.1 CARS contrast For CARS imaging demonstration we chose a cell biology model organism the yeast cell in water. Fig. 2 shows a 3D picture of yeast cell distinguishing the distribution of lipids inside cell. as well (Fig. 3). The spectrum contains several peaks at 2850 cm ¹ and 2900, 2920 cm ¹ which were assigned to the -CH₂, -CH₃ symmetrical, and -CH₂, -CH₃ asymmetrical stretches correspondingly. 12 CARS signal, 10 CPS 3 8 4 0 2600 2800 3000 3200 Ω, cm -1 Fig. 3. The spectrum of the one of lipid droplet inside the yeast cell. The resolution of image is limited by the excitation wavelengths and numerical aperture (NA) of focusing objective. In our case, when 813 nm and 1064 nm excitation light was focused on the sample using objective with 1.42 NA the resolution was of the order of 0.5 µm and 1.5 µm in lateral and axial directions respectively. Fig. 4 shows 3D projection of flower pollen grain located on the surface of objective cover glass. Fig. 2. CARS image of yeast cell recorded at 2850 cm ¹ vibrational frequency. Intensity scale bar indicates the number of photons for a single pixel from 0 to the maximal value. Fig. 4. Three-dimensional projection of flower pollen grain located on the surface of objective cover glass. The scanned volume is cube with size of 15 µm. Image was recorded at the 2850 cm ¹ vibrational frequency the region where C-H vibrations are active. The spectrum of the one of lipid droplet inside the yeast cell was measured Image recorded at the 2880 cm ¹ vibrational frequency. The pointed growths on the grain surface are clearly visible in picture.

4 Optical imaging using coherent anti-stokes Raman scattering and other nonlinear mechanisms 3.2 TPEF contrast Operation of CARS microspectrometer in TPEF imaging mode can be realized in single beam excitation scheme utilizing either OPO or fundamental beam output for sample excitation. The contrast of TPEF image can be enhanced by entering of special fluorophores (labels) into the sample. Often the object under investigation has a strong autofluorescence property enabling label-free TPEF imaging. For instance, the plants contained a lot of chlorophyll give a strong autofluorescence signal. In such type of objects the label-free studying using both TPEF and CARS contrasts can be realized. The imaging of green algae Nostoc commune with CARS and TPEF contrast mechanisms are shown in Fig. 5. This algae has two types of cells: normal cells which have chlorophyll, and heterocyst cells which do not have chlorophyll. Fig. 5(a) shows CARS image tuned to CH₂ vibration contrast where both types of cells are visualized. Fig. 5(b) shows TPEF image of chlorophyll fluorescence. In this figure heterocyst cell is not visible. Combined image (Fig. 5(c)) of two contrasts revealed all type of Nostoc commune cells. In general, TPEF is a competitive process in the CARS technique. It should be noted that correct measurement of CARS signal is possible only in the case when at least one of the excitation beams does not induce the TPEF. Such a beam (not exciting the TPEF) should be used at maximum acceptable intensity, while the beam generating TPEF must be attenuated. Recording CARS image of algae Nostoc commune contribution from TPEF in our experiment was less than 3%. Fig. 5. Pseudo color images of green algae Nostoc commune using different contrast mechanisms: coherent anti-stokes Raman scattering (a), two-photon excitation fluorescence (b) and overlay of CARS and TPEF images (c). 3.2 SHG contrast SHG occurs only in the presence of the compound having a non-centrosymmetric structure. In biological objects the second harmonic is obtained in compounds such as collagen and starch. The imaging based on SHG contrast mechanism reveals the distribution of collagen in life tissue or starch distribution in plant cells. Most distinguishing SHG can be observed in starch grains pulled from potatoes. Fig. 6 demonstrates combined image of some starch grains located on the surface of objective cover glass. In linearly polarized light the SHG picture (green) has a two-lobed pattern. Such a pattern is due to radial orientation of glucose polymers inside the granule [9]. SHG images of some crop plants contained a lot of starch are depicted in Figs. 7-9. For better perception the combined SHG and CARS image is depicted. CARS signal painted red color. Fig. 6. Pseudo color (overlay) image of starch grain of potatoes recorded using two contrast mechanisms: CARS and SHG.

Optical imaging using coherent anti-stokes Raman scattering and other nonlinear mechanisms 5 Fig. 7 shows the image of starch grains of buckwheat seed (Fagopyrum) recorded in two contrasts: SHG (green) and CARS (red). The SHG signal comes from the starch granules for which the orientation of glucose polymers (nonlinear dipoles) coincide with linearly polarized incident light oriented horizontally [9]. Fig. 9 shows SHG/CARS image of starch grain of barley (Hordeum vulgare) seeds. The SHG-image (green color) of the starch grain has a typical pattern when the linearly polarized incident light is used. Fig. 7. Pseudo color (overlay) image of Fagopyrum recorded using two contrast mechanisms: CARS and SHG. The image recorded at the 2880 cm ¹ frequency. Fig. 9. Pseudo color (overlay) image of starch grain of barley (Hordeum vulgare) recorded using two contrast mechanisms: CARS and SHG. CARS signal, 10 CPS 3 30 20 10 0 2600 2800 3000 3200 Ω, cm -1 Fig. 8. CARS spectra of Fagopyrum. Conclusions We have demonstrated that the CARS microspectrometer equipped with a picosecond dual wavelength laser source provides the unified multimodal platform suitable for microscopic investigations using second-order and thirdorder nonlinear optical contrast mechanisms such as TPEF, SHG and CARS. Obtained CARS-images of yeast cell and flower pollen clearly demonstrate label-free and 3D imaging capabilities of CARS technique. Multi-contrast images of green algae and plants containing starch demonstrate a variety of research facilities where the method can be applied.

Optical imaging using coherent anti-stokes Raman scattering and other nonlinear mechanisms 6 References 1. A. Zumbusch; G. R. Holtom; X. S. Xie. Threedimensional vibrational imaging by coherent anti-stokes Raman scattering. Phys. Rev. Lett. 1999, 82, 4142 4145. 2. N. Dudovich; Y. Silberberg. Single-pulse coherently controlled nonlinear Raman spectroscopy and microscopy. Nature 2002, 418, 512 514. 3. J. X. Cheng; X. S. Xie; Coherent anti-stokes Raman scattering microscopy: instrumentation, theory, and applications. J. Phys. Chem. B 2004, 108, 827 840. 4. T. Ichimura; N. Hayazawa; M. Hashimoto; Y. Inouye; S. Kawata. Tip-enhanced coherent anti-stokes Raman scattering for vibrational nanoimaging. Phys. Rev. Lett. 2004, 92, 220801. 5. T. -W. Kee; M. T. Cicerone. Simple approach to one laser, broadband coherent anti-stokes Raman scattering microscopy. Opt. Lett. 2004, 29, 2701 2703. 6. T.-W. Koo; S. Chan; A. A. Berlin. Single-molecule detection of biomolecules by surface-enhanced coherent anti-stokes Raman scattering. Opt. Lett. 2005, 30, 1024 1026. 7. Ji-Xin Cheng; Andreas Volkmer; and X. Sunney Xie. Theoretical and experimental characterization of coherent anti-stokes Raman scattering microscopy. J. Opt. Soc. Am. B 2002, Vol. 19, No. 6, 1363-1375. 8. A. Volkmer. Vibrational imaging and microspectroscopies based on coherent anti-stokes Raman scattering microscopy. J. Phys. D: Appl. Phys. 2005, 38, R59 R81. 9. R. Cisek, L. Spencer, N. Prent, D Zigmantas, George S. Espie, and V. Barzda. Optical microscopy in photosynthesis. Photosynth. Res. Vol. 102, Num. 2-3, pp. 111-141, (2009). ISO 9001 EKSPLA Savanoriu av. 231 02300 Vilnius LITHUANIA Ph.: +370 5 2649629 Fax: +370 5 2641809 sales@ekspla.com www.ekspla.com Find local distributor at www.ekspla.com CERTIFIED Revision number 120314