WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Similar documents
Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Thermodynamics II Chapter 5 Refrigeration

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Performance of an Improved Household Refrigerator/Freezer

Comparative Exergy Analysis of Vapor Compression Refrigeration System Using Alternative Refrigerants

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Chapter 9. Refrigeration and Liquefaction

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

(Refer Slide Time: 00:00:40 min)

Chapter 11 REFRIGERATION CYCLES

Performance and exergy analysis of vapour compression refrigeration system using various alternative of R134a.

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

Chapter 11 REFRIGERATION CYCLES. Department of Mechanical Engineering

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

Week 9. Refrigeration Cycles I. GENESYS Laboratory

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

International Journal of Research in Engineering and Innovation Vol-2, Issue-2 (2018),

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

Chapter 10. Refrigeration and Heat Pump Systems

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Volume 2, Issue 1 (2014) ISSN International Journal of Advance Research and Innovation

LECTURE-17. Multi-Stage Vapour Compression Refrigeration. 1. Introduction

DEEPAK PALIWAL, S.P.S.RAJPUT

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Thermodynamics I. Refrigeration and Heat Pump Cycles

Theoretical study on a modified subcooling vaporcompression refrigeration cycle using hydrocarbon mixture R290/R600a

Chapter 11 REFRIGERATION CYCLES

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Low Global Warming Refrigerants For Commercial Refrigeration Systems

ISSN Vol.08,Issue.21, November-2016, Pages:

A Comparison Between Refrigerants Used In Air Conditioning

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

CASE STUDIES OF THERMALLY DRIVEN HEAT PUMP ASSISTED DRYING. Minh Cuong Tran, Jamy Logie, Bruno Vanslambrouck, Martijn van den Broek

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Performance Study of a Water-to-Water Heat Pump Using Non-azeotropic Refrigerant Mixtures R407C

ADVANCES in NATURAL and APPLIED SCIENCES

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

η second law = Second law efficiency

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation

Use of fourth generation ecofriendly refrigerants in two and three cascade refrigeration systems for reducing global warming and ozone depletion

Modeling And Testing Of R23/R134a Mixed Refrigerant System With Water Cooled Separator For Low Temperature Refrigeration

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

International Engineering Research Journal (IERJ) Special Issue Page , June 2016, ISSN

POTENTIAL OF NON - AZEOTROPIC REFRIGERANT MIXTURE AS WORKING REFRIGERANT IN HOT WATER HEAT PUMPS. FJ Smit and JP Meyer

Modelling the Performance of a Diffusion Absorption Refrigeration System

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

Thermodynamic Calculations of Two-Stage Vapor Compression Refrigeration Cycle with Flash Chamber and Separate Vapor Mixing Intercooler

Refrigerant Glide and Effect on Performances Declaration

Study of R161 Refrigerant for Residential Airconditioning

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

PERFORMANCE OF A VERY LOW TEMPERATURE REFRIGERATION SYSTEM OPERATING WITH NATURAL FLUIDS

Theoretical and Experimental Analysis of the Superheating in Heat Pump Compressors. * Corresponding Author ABSTRACT 1.

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

Thermodynamic Analysis of Combined Vapor Compression and Vapor Absorption Refrigeration System ABSTRACT

Performance characteristics of low global warming potential R134a alternative refrigerants in ejector-expansion refrigeration system

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Chapter 11. Refrigeration Cycles. Study Guide in PowerPoint

A RECENT REVIEW OF REFRIGERANT R-1234YF AND R-1234ZE (E)

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

Transcritical Carbon Dioxide Microchannel Heat Pump Water Heaters: Part II - System Simulation and Optimization

Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Modeling and Testing of an R-23/R-134a Mixed Refrigerant System for Low Temperature Refrigeration

ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER

TYPICAL INITIAL OUTPUT OF A CO 2 HEAT PUMP

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Department of MCE, Islamic University of Technology 2. Abstract

ADVANCES in NATURAL and APPLIED SCIENCES

Analysis of Vapour Compression Refrigeration System with Refrigerants R134a, R143a, R152a, R290 and R32

Transcription:

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM Sachin Kumar 1, Vicky Ranga 2 1Assistant Professor, Department of Mechanical Engineering, Jagan Nath University Jhajjar, Haryana, India. 2Scholar. Department of Mechanical Engineering, Jagan Nath University Jhajjar Haryana, India. ---------------------------------------------------------------------***--------------------------------------------------------------------- Abstract - Ammonia/CO 2 mixture is presently considered to be the best for cascade refrigeration up to 216.58 K. However to approach temperatures lower than 216.58 K the mixture of CO 2 with other refrigerants are required. The aim of present work was to study the possibility of using carbon dioxide mixtures in those applications where temperatures below triple point (216.58 K) are needed. The blends considered for analysis purpose are R744/R125, R744/R41, R744/R32, and R744/R23. The analysis of cascade refrigeration cycle has been carried out with the help of a computer program developed using Engineering Equation Solver (EES). The composition of CO 2 is varied from a mole fraction of 0.1 to 0.8 along with R23, R32, R41 and R125. The mixtures properties of the investigated blends (R744/R125, R744/R41, R744/R32, and R744/R23) were calculated by Ref Prop 7.0 and used in EES program. Ammonia is used as refrigerant in hightemperature-circuit. Blend of CO 2 with R125 having a mole fraction ratio of 0.3/0.7 is the best among all the blends considered as it offers highest COP values. Up to mole fraction ratio 0.5/0.5, CO 2/R125 blend is better than other blends for same mole fraction ratio. At mole fraction ratio of 0.8/0.2, the blends R744/R125, R744/R41and R744/R32 have almost same values of COP and that of R744/ R32 blend is lowest. Hence R744 blends are an attractive option for the low-temperature circuit of cascade systems operating at temperatures approaching 200 K. Key Words: Cascade System, Mole Fraction, R744 Blends, COP Values, Triple Point, 1. INTRODUCTION Refrigeration is defined as the transfer of heat from a lower temperature region to a higher temperature one. Refrigeration devices that produce refrigeration are heat pumps, refrigerators, automotive air-conditioners, and residential/commercial air-conditioners. All of these devices have one thing is common, to reduce the temperature of an enclosed environment. Vapor compression cycle can be used in temperature range -10 to -30 C easily. And lowtemperature refrigeration systems are typically required in the temperature range from 30 C to 100 C for applications in food, pharmaceutical, chemical, and other industries, e.g., blast freezing, cold storages, liquefaction of gases such as natural gas, etc. At such low temperatures, single-stage compression systems with reciprocating compressors are generally not feasible due to high pressure ratios. A high pressure ratio implies high discharge and oil temperatures and low volumetric efficiencies and, hence, low COP values. Screw and scroll compressors have relatively flat volumetric efficiency curves and have been reported to achieve temperatures as low as 40 C to 50 C in single-stage systems (Stegmann, 2000). Further, the use of a single refrigerant over such a wide range of temperature results in either extremely low pressures in the evaporator and large suction volumes or extremely high pressures in the condenser. To increase volumetric efficiency and refrigerating effect and to reduce power consumption, multistage with intercooling is often employed (Bansal and Jain, 2006). J. Sarkar and S. Bhattacharya (2008) did their research work on assessment of blends of CO 2 with Butane and Isobutene as working fluid in cascade system. Their research work comes to the result that due to gliding temperature during evaporation and condensation the zoetrope blends instead of pure container can be employed very effectively in heat pumps for variable temperature or simultaneously cooling and heating applications. The blend R744/R600a can be the best alternative refrigerant to R114 for high temperature heating due to superior COP (more than twice) over R600 and R600a. J.Alberto Dopazo, Jose F. Seara (2010); evaluated experimentally the design, construction of an experimentally prototype of a CO 2-NH 3 cascade refrigeration system to apply horizontal plate freezer of 9KW of normal refrigeration capacity at -50*C evaporating temperature, the analysis shows that the overall efficiency of the system will be increased up to 19.5% higher than the common double stage refrigeration process at -40*C evaporating temperature. 1.1 Thermal Performance Analysis of Cascade System Fig.1 schematically represents a cascade refrigeration system. Fig.2 represents the corresponding pressure enthalpy diagrams. This refrigeration system comprises two separate refrigeration circuits- the high-temperature circuit (HTC) and the low- temperature circuit (LTC). Ammonia is the refrigerant in HTC, whereas carbon dioxide blend with HFCs (R-23, R-32, R-41 and R-125) are the refrigerants in LTC. The circuits are thermally connected to each other through a cascade-condenser, which acts as an evaporator for the HTC and a condenser for the LTC. 2018, IRJET Impact Factor value: 7.211 ISO 9001:2008 Certified Journal Page 2300

condensing temperature of the cascade- condenser. The following assumptions are made to simplify the thermodynamic analysis, including energy analysis. 1. All components are assumed to be a steady-state and steady-flow process. The changes in the potential and the kinetic energy of the components are negligible. 2. The high and low-temperature circuit compressors are non-isentropic. Fig.1 Schematic representation of two stage cascade refrigeration cycle The condenser in this cascade refrigeration system rejects a heat of QC from the condenser at condensing temperature of TC, to its warm coolant or environment at temperature of T0. The evaporator of this cascade system absorbs a refrigerated load QE from the cold refrigerated space at evaporating temperature T E. The heat rejected by condenser of LTC equals the heat absorbed by the evaporator of the HTC. T MC and T ME represent the condensing and evaporating temperatures of the cascade condenser, respectively. Approach represents the difference between the condensing temperature of LTC and the evaporating temperature of HTC. The evaporating temperature TE, the condensing temperature TC, and the temperature difference in the cascade-condenser are three important design parameters of a cascade refrigeration system. 3. The heat loss and pressure drops in the piping connecting the components are negligible. 4. All throttling devices are isenthalpic. Based on the assumptions mentioned above, the equations for mass and energy balance are written for each component. Each component in the cascade refrigeration system, shown in Fig.7 considered as a control volume. Mass balance: - in m r = out m r (1) Energy balance:- Q W + in m r h out m r h = 0 (2) Energy changes in each component of cascade refrigeration cycle are as follows:- Evaporator: evaporator is a heat exchanger which abstract heat from the cold room and this heat is called refrigeration effect, which is given by:- QE = m r1 (h 1-h 4) (3) Compressor: compressor is a work absorbing device in which, the isentropic work input to the compressor is expressed as In compressor 1:- W comp1 = m r1 (h 2-h 1) (4) In compressor 2:- W comp2 = m r2 (h 6-h 5) (5) Fig.2 P-h diagram of cascade refrigeration system 1.2 Thermodynamic Analysis In the present work, a parametric study with fixed mass flow rate in LTC, and various condensing temperature, evaporating temperature and approach in the cascadecondenser have been conducted to determine the optimum Condenser: condenser is a heat exchanger in which heat rejected by the condenser to the environment or warm coolant is given as:- Q c: - m r2 (h 6-h 7) (6) Expansion Valve: expansion valve is a device in which expansion of refrigerant occurred and enthalpy remains constant. 2018, IRJET Impact Factor value: 7.211 ISO 9001:2008 Certified Journal Page 2301

In expansion valve 1: h 3 = h 4 (7) In expansion valve 2: h 7 = h 8 (8) Cascade condenser: it acts as an evaporator in the hightemperature stage and as a condenser in the lowtemperature stage. Cascade condenser is a heat exchanger in which all the heat released by the low-temperature-circuit condenser is rejected to the high- temperature-circuit evaporator. Energy balance in cascade condenser is:- m r1(h 2-h 3) = m r2(h 5-h 8) (9) Where mr 1 = mass flow rate in low temperature circuit mr 2 = mass flow rate in low temperature circuit Coefficient of performance:- The performance parameter, COP of a cascade system is defined as the ratio of the refrigerating effect produced in the evaporator to the total work input to all compressors in the system. It can be express by following expression. COP = Q E (Wcomp 1 + W comp2) (10) Volumetric cooling capacity:- The volumetric cooling capacity is the cooling capacity per unit volume flow rate at the inlet to the compressor. It can be express by following expression:- VCC = Q E (m r1 V S) (11) Where Vs = specific volume at inlet of the compressor 2. Cascade refrigeration system with liquid vapor heat exchanger Analysis of the cascade Refrigeration System shown in fig.1 and fig.3 has been carried out in this work. The computer program has been developed in EES (Klein and Alvarado, 2005). The mixtures properties of the investigated blends (R744/R125, R744/R41, R744/R32, and R744/R23) were calculated by Ref Prop 7.0 (Huber et al. 2002 and used in EES program to calculate the performance parameters for a cascade refrigeration cycle. For validation of program, results of the present work are compared with results of Nicola et al. (2005). Comparison of results for carbon dioxide (0.1 mole fraction) blend with R-125 and R-41 are shown in figure 6 and 7. The results from present work are 5% higher than that of Nicola et al. (2005). Fig -3 Schematic representation of cascade refrigeration cycle with liquid vapor heat exchanger The Input Parameters taken for computation of results are given below Condenser Temperature Tc = 40 to 50 C in steps of 5ºC Evaporator Temperature TE = -70 C Cascade condenser temperature TMC = 10 to -60 C in steps of 5ºC Approach A = 0, 5 C Mass flow rate in low temperature circuit mr1 = 1 kg/sec Compressor efficiency in low temperature circuit η c1 = 0.7 Compressor efficiency in high temperature circuit η c2 = 0.7 Refrigerant in high temperature circuit = R-717 Refrigerant in low temperature circuit= CO 2 blend with HFCs HFCs used with carbon dioxide: R-23, R-32, R-41, R-125 Sub cooling (in HTC and LTC) = 0, 5 C Superheating (in HTC and LTC) = 0, 10 C By carrying out the thermodynamic analysis of the system for the conditions stated above the values at various state points of the cascade refrigeration cycle have been obtained. The computer program for the thermodynamic analysis of the system developed in EES has been given in Appendix A along with its flow diagram for computation procedure. In the present work, following parameters have been computed. Total compressor work. 2018, IRJET Impact Factor value: 7.211 ISO 9001:2008 Certified Journal Page 2302

Coefficient of performance of the cascade refrigeration cycle. Volumetric cooling capacity of the compressor. Ratio of mass flow rate in HTC and LTC. Based on above we have computed optimal cascade condenser temperature. Fig -6 Variation in COP with intermediate temperature for cascade system operating with R744 blend at 0.1 mole 0ºC Fig -4 comparison of results with Nicola et al. results for R-125 Fig -7 Variation in COP with intermediate temperature for cascade system operating with R744 blend at 0.3 mole 0ºC Fig -5 comparison of results with Nicola et al. results for R- 41 3. Result and discussion Figs 6 to 8 shows the variation of COP for cascade refrigeration cycle with varying intermediate temperature for carbon dioxide blend with HFCs (R-23, R-32, R-41 and R-125) for different mole fraction. These figures show that the COP increases with increase in intermediate temperature up to a temperature (optimum temperature) after this COP decreases with increase in intermediate temperature at a particular evaporator and condenser temperature. COP for R-125 mixture is highest among all mixtures followed by R-32, R-41 and R-23 respectively. Optimum temperature range for cascade refrigeration system is 240 K to 260 K. 3.1 Effect of approach Approach is temperature difference between high temperature circuit evaporator and low temperature condenser. Figs 6 to 8 (with approach 0) and Figs 9 to 11 (with 5 C approach) show that by taking approach 5 C, COP decreases as around 8%, because of increase in compressor work. Optimum temperature is shifted 2% to higher side by taking approach. 2018, IRJET Impact Factor value: 7.211 ISO 9001:2008 Certified Journal Page 2303

Fig -8 Variation in COP with intermediate temperature for cascade system operating with R744 blend at 0.5 mole 0ºC. Fig -10: Variation in COP with intermediate temperature for cascade system operating with R744 blend at 0.3 mole 5ºC. 3.2 Effect of superheating (10 C) and subcooling (5 C) Figs 6 to 8 show the effect of superheating of refrigerant inlet to compressor and subcooling of refrigerant outlet to condenser. By the comparison of figures with superheating and without superheating (Figs 9 to 11), COP increases by superheating and subcooling, this happens because by superheating work done increases and by subcooling refrigerating effect also increases, and combined effect of these is to increase COP. For R-125 mixture (with carbon dioxide) effect of superheating and subcooling on increase in COP is very high. At optimum temperature COP increased around 1% by superheating and subcooling. Fig -11: Variation in COP with intermediate temperature for cascade system operating with R744 blend at 0.5 mole 5ºC. 3.3 Effect of mole fraction of carbon dioxide Fig.12 show the variation of mole fraction of carbon dioxide in mixture with HFCs. Figure show that by increasing mole fraction of carbon dioxide COP affect slightly. For R-23 and R-41, COP decreases with increase in mole fraction of carbon dioxide. For R-125, COP increases up to mole fraction 0.3 and after this decrease up to mole fraction 0.9. For R-32, COP decreases up to mole fraction 0.8 and after this COP increases. Fig -9: Variation in COP with intermediate temperature for cascade system operating with R744 blend at 0.1 mole 5ºC. 2018, IRJET Impact Factor value: 7.211 ISO 9001:2008 Certified Journal Page 2304

4. Wilson, I., Maier, D. (2006), Carbon dioxide for use as a refrigerant, The University of Auckland, pp. 305 311. 5. Lee, T.S., Liu, C.H., Chen, T.W. (2006), Thermodynamic analysis of optimal condensing temperature of cascade-condenser in CO2/NH3 cascade refrigeration system, International Journal of Refrigeration 29, pp. 1100-1108. 6. Sawalha, S., Cabrajas; 2007, experimental investigation of NH3/CO2 cascade system and comparison to R404a system for supermarket. Fig -12: Variation in COP with CO2 mole fraction for cascade system operating with R744 blends as low temperature working fluid. 4. CONCLUSIONS In the present study, thermodynamic analysis have been carried out for cascade refrigeration cycle using CO2/HFC blends as the low-temperature fluid and ammonia as the high- temperature fluid with a view to extending the applicability of carbon dioxide in such systems below its triple point (216.58 K). The results obtained permit the following remarks: 1. COP increases with increase in intermediate temperature up to a temperature 7. B.A. Younglove; Thermo-physical properties of natural refrigerant such as ethane, methane, propane, butane, isobutene CO2, N2O etc. 8. G.K. Christensen; Refrigeration system supermarket with Propane and CO2 energy consumption and economy analysis. 9. International journals on refrigeration by international refrigeration committee of the UK institute of refrigeration. 10. Domanski P, McLinden M. A simplified cycle simulation model for the performance rating of refrigerants and refrigerant mixtures. Int J Refrig. 1992. (optimum temperature) after this COP decreases with increase in intermediate temperature. 2. COP for R-125 mixture is highest among all mixtures followed by R-32, R-41 and R-23 respectively. 3. Optimum temperature range for cascade refrigeration system is 245 K to 260 K without superheating and subcooling and 250 K to 265 K, with superheating and subcooling. REFERENCES 1. Nicola, G.D., Giuliani, G., Polonara, F., and Stryjek, R. (2005), Blends of carbon dioxide and HFCs as working fluids for the low temperature circuit in cascade refrigerating systems, International Journal of Refrigeration, 28, pp. 130 40. 2. Getu, H.M., Bansal, P.K. (2008), Thermodynamic analysis of an R744 R71 cascade refrigeration system International Journal of Refrigeration 31, pp. 45 54. 3. Bhattacharyya, S., Mukhopadhyay, S., Kumar, A., Khurana, R.K., Sarkar, J. (2005), Optimization of a CO2 C3H8 cascade system for refrigeration and heating, International Journal of Refrigeration, 28, pp. 1284-1292 2018, IRJET Impact Factor value: 7.211 ISO 9001:2008 Certified Journal Page 2305