Ozone Gas Sensor. (Model:MQ131 High Concentration) Manual. Version: 1.4. Valid from: Zhengzhou Winsen Electronics Technology Co.

Similar documents
Ammonia Gas Sensor. (Model:MQ137) Manual. Version: 1.4. Valid from: Zhengzhou Winsen Electronics Technology Co., Ltd

Smoke Sensor. (Model:MQ-2) Manual. Version: 1.4. Valid from: Zhengzhou Winsen Electronics Technology Co., Ltd

Air-Quality Gas Sensor (Model: MP905) Manual. Version:1.1. Valid From: Zhengzhou Winsen Electronics Technology Co., Ltd

MEMS Carbon Monoxide Gas Sensor. (Model No.:GM-702B) Manual. Version: 1.1. Valid from: Zhengzhou Winsen Electronics Technology Co.

Catalytic Gas Sensor. (Model: MC113/ MC113C) Manual. Version: 1.3. Valid from: Zhengzhou Winsen Electronics Technology Co.

Air-Quality Gas Sensor (Model:MP503) Manual. Version:1.3. Valid From: Zhengzhou Winsen Electronics Technology Co., Ltd

Catalytic Flammable Gas Sensor. (Model: MC105B) User s Manual. Version: 1.3. Valid from: Zhengzhou Winsen Electronics Technology Co.

ZP04 Flammable Gas Detection Module (Model:ZP04) Manual V1.1. Zhengzhou Winsen Electronics Technology Co., Ltd

Air-Quality Detection Module. User s Manual

Air-Quality Detection Module. User s Manual

Intelligent Infrared Carbon Dioxide Module (Model: MH-Z14A)

Manual Zhengzhou Winsen Electronics Technology Co., Ltd

an ISO9001 company TECHNICAL INFORMATION FOR TGS813 Technical Information for Combustible Gas Sensors

an ISO9001 company TECHNICAL INFORMATION FOR TGS813 Technical Information for Combustible Gas Sensors

TGS for the detection of Carbon Monoxide

KAE Gas Alarm Operation Manual

E1000 Portable gas detector

an ISO9001 company APPLICATION NOTES FOR TGS2611 Application Notes for Methane Gas Detectors using TGS2611

IMR EX610. Portable Gas Detector. Operation Manual

an ISO9001 company APPLICATION NOTES FOR TGS2610 Application Notes for LP Gas Detectors using TGS2610

Pyroelectric Infrared Sensors

KAB Gas Alarm Operation Manual

O3TH. Ozone Detector c/w Indicator for Temperature/Humidity. Automatikprodukter. Features. Technical Data. Description. Ordering Codes. Dec.

OX100/OX102. Limiting-current type Oxygen Analyzer. Bulletin 11M10A01-03E

Pyroelectric Infrared Sensors

Web Site: Forums: forums.parallax.com Sales: Technical:

Data Sheet Sensor: IRA-S210ST01 Lens: IML-0685 / IML Sensor : IRA-S210ST01 Lens : IML-0685/0688. Pyro Electric Infrared Sensor Fresnel Lens

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL

Model OEM-2 INSTRUCTIONS FOR USE

GD Series Gas Alarm Operation Manual

QD6310. Fixed Gas Detector Operation Manual

Application note. LCD Module. Precautions for LCM handling. LCM handling V 1.1

TECHNICAL DATA MQ-2 GAS SENSOR

M004 combustible gas module

OX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102. Bulletin 11M10A01-03E

A214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption

Application Notes For LED Displays

Piezo-electric Devices Precaution Usage

Infrared Carbon Dioxide Sensor Module CM1107-Dual Beam

Operation and Maintenance Manual

OPERATING INSTRUCTIONS WPSI12. Portable Soldering Station & TCP12. Soldering Tool. Weller Tech Sheet Product Code: Issue A 24/05/05

TC100N. Fixed Gas Detector Operation Manual

DSSHP06G Intelligent Lead Free Soldering Station INSTRUCTION MANUAL

APPLICATION NOTES for LED DISPLAYs

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

QUICK 3202 OPERATION MANUAL. Lead Free Soldering Station

Reverse Package Infrared LED IR25-21C/TR8

852 SMD REWORK SOLDERING STATION MANUAL

IAQ_100 C Package

DSSLF2X04H 2 IN 1. Intelligent Lead Free Soldering Station. OPERATION and MAINTENANCE MANUAL

Ionizer (Static Remover) STABLO-EX Instruction Manual

Infrared Carbon Dioxide Sensor Module CM1106SL

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Used as indicators of indicating the Degree, Functions, Positions etc, in electronic instruments

SPECIFICATION OF ELECTRET CONDENSER MICROPHONE ( TO : )

LED New Light Source Reflow Oven. Model: T-960

SHENZHEN ZHUOMAO TECHNOLOGY CO., LTD. BGA Rework Station ZM-R5860C Instruction Manual

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

General safety precautions English

TOXIC GAS AND OXYGEN DETECTOR DTX 420 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS DTX420_MAN01_EN_V1R2

Reflow Soldering Guidelines

Mini SMT Reflow Oven Model: T-961

BEP Marine Gas Detector 600-GDRV

Room air quality sensors

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

General safety precautions English

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

Room Air Quality Sensors

Chlorine gas leak detector

Models TX-KE and TX-KP Toxic Gas Transmitters

ELIMINOSTAT DC-ESR-CL-S2

CARBON MONOXIDE CO SS SOLID STATE ELECTROCHEMICAL SENSORS

TOCOS. Guidelines & Precautions. For Using Trimmer Potentiometers. Guidelines for Circuit Design. Guidelines for Production Processes

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

Thermoelectric Bath. Series HEB

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

ML562G84 APPLICATION. Display system. Symbol Parameter Conditions Ratings Unit. Pulse (Duty 40%)

ML60171C FEATURES. φ5.6mm TO-CAN PKG (with monitor PD) APPLICATION Motion sensor Printing. Reverse voltage (PD)

Duct Air Quality Sensors

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

ZMOTION Pyroelectric Sensors

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

OPERATING AND MAINTENANCE MANUAL

This instruction manual explains the use of three models listed on the left.

BEP Marine Gas Detector FD-2

474A+ TIP CARE AND USE INSTRUCTION MANUAL DESOLDERING STATION

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

HEB Series. Peltier-Type Thermoelectric Bath

The ultimate in air handling units: directly and indirectly fired

Service Manual For electronic dual temperature zone wine cellar Includes DWC282 / 283

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

EVERLIGHT ELECTRONICS CO.,LTD.

Visual Leak Detectors for Hydrogen Equipment. Presented by

Metal, ceramic, plastic package products

Two-Channel Gas Controller

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

MHTR1D Resistance humidity sensor. MHTR1D humidity and temperature sensor module Data sheet

Transcription:

Ozone Gas Sensor (Model:MQ131 High Concentration) Manual Version: 1.4 Valid from: 2015-03-10 Zhengzhou Winsen Electronics Technology Co., Ltd

Statement This manual copyright belongs to Zhengzhou Winsen Electronics Technology Co., LTD. Without the written permission, any part of this manual shall not be copied, translated, stored in database or retrieval system, also can t spread through electronic, copying, record ways. Thanks for purchasing our product. In order to let customers use it better and reduce the faults caused by misuse, please read the manual carefully and operate it correctly in accordance with the instructions. If users disobey the terms or remove, disassemble, change the components inside of the sensor, we shall not be responsible for the loss. The specific such as color, appearance, sizes &etc, please in kind prevail. We are devoting ourselves to products development and technical innovation, so we reserve the right to improve the products without notice. Please confirm it is the valid version before using this manual. At the same time, users comments on optimized using way are welcome. Please keep the manual properly, in order to get help if you have questions during the usage in the future. Zhengzhou Winsen Electronics Technology CO., LTD

Zhengzhou Winsen Electronics Technology Co., Ltd www.winsen-sensor.com MQ131 Ozone Gas Sensor (High Concentration) Profile Sensitive material of MQ131 gas sensor is semiconductor metallic oxide, which with high conductivity in clean air. When the ozone gas exists, the sensor s conductivity gets lower along with the gas concentration rising. Users can convert the change of conductivity to correspond output signal of gas concentration through a simple circuit. MQ131 ozone gas sensor has high sensitivity to ozone, and also has sensitivity to strong oxide such as Cl 2, NO 2 &etc. It responses oppositely to organic interference gases. Features It has good sensitivity to ozone in wide range, and has advantages such as long lifespan, low cost and simple drive circuit &etc. Main Applications It is widely used in domestic ozone concentration alarm, industrial ozone concentration alarm and portable ozone concentration detector. Technical Parameters Stable.1 Standard Circuit Conditions Sensor character under standard test conditions Model Sensor Type Standard Encapsulation Target Gas Detection range MQ131 Semiconductor Bakelite, Metal cap Ozone 10~1000ppm Ozone Loop Voltage V c 24V DC Heater Voltage V H 5.0V±0.1V AC or DC Load Resistance R L Adjustable Heater Resistance R H 31Ω±5Ω (room temp.) Heater consumption P H 900mW Sensitivity S Rs(in 200ppm O 3 ) / Rs(in air) 2 Output Voltage Vs 1.0V(in 200ppm O 3 ) Concentration Slope α 0.6( R 10ppm /R 100ppm O 3 ) Tem. Humidity 20 ±2 ;55%±5%RH Standard test conditions Standard test circuit Preheat time Vc:5.0V±0.1V; V H : 5.0V±0.1V Over 48 hours NOTE: The change of Output voltage( Vs) is the difference value between V RL in test environment and Fig1.Sensor Structure Unit: mm

Basic Circuit Zhengzhou Winsen Electronics Technology Co., Ltd www.winsen-sensor.com Fig2. MQ131 Test Circuit Instructions: The above fig is the basic test circuit of MQ131.The sensor requires two voltage inputs: heater voltage (V H ) and circuit voltage (V C ). V H is used to supply standard working temperature to the sensor and it can adopt DC or AC power, while V RL is the voltage of load resistance R L which is in series with sensor. Vc supplies the detect voltage to load resistance R L and it should adopts DC power. Description of Sensor Characters O 3 Air Fig3.Typical Sensitivity Curve The ordinate is resistance ratio of the sensor (Rs/R 0 ), the abscissa is concentration of gases. Rs means resistance in target gas with different concentration, R 0 means resistance of sensor in clean air. All tests are finished under standard test conditions. Fig4.Typical temperature/humidity characteristics The ordinate is resistance ratio of the sensor (Rs/Rso). Rs means resistance of sensor in 200ppm O 3 gas under different tem. and humidity. Rso means resistance of the sensor in 200ppm O 3 gas under 20 /55%RH.

Zhengzhou Winsen Electronics Technology Co., Ltd www.winsen-sensor.com Fig5.Sensitity Curve Fig5 shows the V RL in O 3 gas with different concentration. The resistance load R L is 10 KΩ and the test is finished in standard test conditions. Fig6.Responce and Resume Fig5 shows the changing of V RL in the process of putting the sensor into target gas and removing it out. Cautions 1.Following conditions must be prohibited 1.1 Exposed to organic silicon steam Sensing material will lose sensitivity and never recover if the sensor absorbs organic silicon steam. Sensors must avoid exposing to silicon bond, fixature, silicon latex, putty or plastic contain silicon environment. 1.2 High Corrosive gas If the sensors are exposed to high concentration corrosive gas (such as H 2 S, SO X, Cl 2, HCl etc.), it will not only result in corrosion of sensors structure, also it cause sincere sensitivity attenuation. 1.3 Alkali, Alkali metals salt, halogen pollution The sensors performance will be changed badly if sensors be sprayed polluted by alkali metals salt especially brine, or be exposed to halogen such as fluorine. 1.4 Touch water Sensitivity of the sensors will be reduced when spattered or dipped in water. 1.5 Freezing Do avoid icing on sensor s surface, otherwise sensing material will be broken and lost sensitivity. 1.6 Applied higher voltage Applied voltage on sensor should not be higher than stipulated value, even if the sensor is not physically damaged or broken, it causes down-line or heater damaged, and bring on sensors sensitivity characteristic changed badly. 1.7 Voltage on wrong pins For 6 pins sensor, Pin 2&5 is heating electrodes, Pin (1,3)/(4,6) are testing electrodes (Pin 1 connects with Pin 3, while Pin 4 connects with Pin 6).If apply voltage on Pin 1&3 or 4&6, it will make lead broken; and no signal putout if apply on pins 2&4. Fig7. Lead sketch

Zhengzhou Winsen Electronics Technology Co., Ltd www.winsen-sensor.com 2.Following conditions must be avoided 2.1 Water Condensation Indoor conditions, slight water condensation will influence sensors performance lightly. However, if water condensation on sensors surface and keep a certain period, sensors sensitive will be decreased. 2.2 Used in high gas concentration No matter the sensor is electrified or not, if it is placed in high gas concentration for long time, sensors characteristic will be affected. If lighter gas sprays the sensor, it will cause extremely damage. 2.3 Long time storage The sensors resistance will drift reversibly if it s stored for long time without electrify, this drift is related with storage conditions. Sensors should be stored in airproof bag without volatile silicon compound. For the sensors with long time storage but no electrify, they need long galvanical aging time for stability before using. The suggested aging time as follow: Stable2. Storage Time Less than one month Suggested aging time No less than 48 hours 1 ~ 6 months No less than 72 hours More than six months No less than 168 hours 2.4 Long time exposed to adverse environment No matter the sensors electrified or not, if exposed to adverse environment for long time, such as high humidity, high temperature, or high pollution etc., it will influence the sensors performance badly. 2.5 Vibration Continual vibration will result in sensors down-lead response then break. In transportation or assembling line, pneumatic screwdriver/ultrasonic welding machine can lead this vibration. 2.6 Concussion If sensors meet strong concussion, it may lead its lead wire disconnected. 2.7 Usage Conditions 2.7.1For sensor, handmade welding is optimal way. The welding conditions as follow: Soldering flux: Rosin soldering flux contains least chlorine homothermal soldering iron Temperature: 250 Time:less than 3 seconds 2.7.1If users choose wave-soldering, the following conditions should be obey: Soldering flux: Rosin soldering flux contains least chlorine Speed: 1-2 Meter/ Minute Warm-up temperature:100±20 Welding temperature:250±10 One time pass wave crest welding machine If disobey the above using terms, sensors sensitivity will reduce. Zhengzhou Winsen Electronics Technology Co., Ltd Add: No.299, Jinsuo Road, National Hi-Tech Zone, Zhengzhou 450001 China Tel: +86-371-67169097/67169670 Fax: +86-371-60932988 E-mail: sales@winsensor.com Website: www.winsen-sensor.com