GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

Similar documents
SERVICE BY QUALIFIED PERSONNEL ONLY

Bdl60u Fluorescent Emergency Ballast

ESRB and ESRN Installation & Safety Instructions

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

Installation Instructions

Ni - Cd THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

MODEL LUT-ATS-D (EPC-D-F-ATS) INSTALLATION ! IMPORTANT SAFEGUARDS!

HIGH BAY APPLICATIONS

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400

Application Note. Using XPoint Wireless Devices with Emergency Lighting. 1 of 16

CDL8 LED Architectural

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

BACKUP BATTERY INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

Emergency Lighting Transfer System Model: ELTS2 Installation and User Operation Manual

TSLED STAIRWELL INSTALLATION INSTRUCTIONS

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

USER GUIDE & INSTALLATION INSTRUCTIONS

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

WPLED 26W INSTALLATION INSTRUCTIONS

Douglas Lighting Controls. Bluetooth Fixture Controller & Sensor. Installation Manual BT-FMS-A. *Patent Pending. Installation Guide BT-FMS-A v7

MaxLite LED Round Pendant Highbay Series

USER GUIDE & INSTALLATION INSTRUCTIONS

DHL-LP-LED Low Profile LED Linear High/Low Bay

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

20W and 45W Dimmable LED Power Supply INSTALLATION GUIDE. Copyright ASP Holdings, Inc.

Installation Instructions

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

Albeo TM LED Luminaire Accessory (Emergency Battery Backup Module)

Installation Guide for models:

Honeywell Durafit LED Retrofit Kit

HighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75

Cold Deck Canopy and Shelf Lights and Retrofit Kit

Installation Guide for models:

EATON DFDAP-M / FDAP-M Remote Alarm Panels

DRC12FR DRC12FR347. Dynalite. Install Guide

Power Supply Display Module PSDM. Installation and Operation Manual

Installation Instructions

Installation Instructions

SP-1000X. Panic Device Power Controller Installation Guide. Rev

LED Emergency Battery Backup

UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx:

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

ARTEMIS Series of Low Occupancy LED Ceiling Mounted Fixtures (Including Stairwells) Installation & Operation Guide

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

FPC-02 Series. Installation and Operating manual

SECTION LOW VOLTAGE LIGHTING CONTROLS

XET-20 Series 20 Amp Emergency Lighting Control Device

LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

Cold Door 2 LED Retrofit Kit Lighting System

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Dual Column Dehydrating Breather Manual

P4200PM / P5000PM Remote Air Dryer User s Guide

Related Sections: TBD. Effective Date: January 1, 2016

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

Unison Echo Room Controller

For more information, please visit 3-form.com or call

RAM3 Remote Alarm Module

Installation Instructions for W2H Series Signals

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

MANUAL RESET ALARM RELEASE BOX

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

IN2 Lighting Control Devices

Dual Input ph/orp Analyzer

LED IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

GPF Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

MLLG-DE-LED-CHAN Installation Guide IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

Installation Instructions

Emergency Lighting. Product Guide LED. The right source for the. right light

Relay Panel and Relay Panel Module Wiring and installation manual Light is OSRAM

OG5000 Ozone Generator Model OG5000B-A. User Manual

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

Series. Access Power Controllers. Installation Guide

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual

LOSBAY800. BAY SENSOR Installation Manual. LOSBAY800 Specifications

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

P6500W Air Dryer User s Guide

MaxLite LED Vapor Tight Linear Fixture

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

BAS SFP22 Edge-lit LED Panel

INTRODUCTION / TABLE OF CONTENTS

ecolor Graze Powercore Linear LED surface light for wall washing and grazing

Transcription:

Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/ CONTROL DEVICE UL 1008-BCELTS UL 924-Switch Bypass! IMPORTANT SAFEGUARDS! WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. This product is for use with generator-supplied (or central inverter system-supplied) lighting loads. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 2. To reduce the risk of electric shock, disconnect all power sources before servicing. 3. This product is for field installation. 4. This product is for use in indoor or damp locations where the ambient temperature is -20ºC minimum, +55ºC maximum. 5. This product is UL Listed as either a Branch Circuit Emergency Lighting Transfer Switch (BCELTS) under UL 1008 or a Switch Bypass under UL 924. Use the proper wiring diagram in the appropriate section of these instructions. 6. An unswitched, normal AC power source (120 through 277 VAC, 50/60 Hz) and a direct, separate connection to a generator-supplied or central inverter system-supplied emergency panel are required. 7. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. 8. Do not use this product for other than intended use. 9. Servicing should be performed by qualified service personnel. SAVE THESE INSTRUCTIONS CAUTION: THIS UNIT HAS MORE THAN ONE POWER SUPPLY CONNECTION POINT. TO REDUCE THE RISK OF ELECTRIC SHOCK, DISCONNECT ALL POWER SOURCES BEFORE INSTALLING OR SERVICING THIS UNIT. SERVICE BY QUALIFIED PERSONNEL ONLY NOTE: BEFORE INSTALLING THE CONTROL DEVICE, MAKE SURE THAT THE NECESSARY BRANCH CIRCUIT WIRING IS AVAILABLE. AN UNSWITCHED SOURCE OF POWER IS REQUIRED. A SEPARATE CONNECTION TO A GENERATOR-SUPPLIED (OR CENTRAL INVERTER SYSTEM-SUPPLIED) CIRCUIT MUST ALSO BE PROVIDED. 06/19/18 Philips Emergency Lighting 236 Mt. Pleasant Rd. Collierville, TN 38017-2752 Tech Support 888-263-4638 Fax 901-853-5009 www.philips.com/bodine 70100047

CAUTION: THIS UNIT HAS MORE THAN ONE POWER SUPPLY CONNECTION POINT. TO REDUCE THE RISK OF ELECTRIC SHOCK, DISCONNECT ALL POWER SOURCES BEFORE INSTALLING OR SERVICING THIS UNIT. NOTE: BEFORE INSTALLING THE CONTROL DEVICE, MAKE SURE THAT THE NECESSARY BRANCH CIRCUIT WIRING IS AVAILABLE. AN UNSWITCHED SOURCE OF POWER IS REQUIRED. A SEPARATE CONNECTION TO A GENERATOR-SUPPLIED (OR CENTRAL INVERTER SYSTEM-SUPPLIED) CIRCUIT MUST ALSO BE PROVIDED. STEP #1 MOUNTING THE > FAMILIARIZE YOURSELF WITH THESE INSTRUCTIONS BEFORE BEGINNING INSTALLATION. > Mount in a convenient location using appropriate hardware (not supplied). See Illustration 1 for typical installation. DO NOT MOUNT WITH LID FACING DOWN (See Illustration 2). ILLUSTRATION 1 ILLUSTRATION 2 WALL MOUNTING FACE DOWN MOUNTING (NOT APPROVED) STEP #2 INSTALLING THE > Disconnect AC power from all supply circuits. > Remove lid and install necessary conduit and wiring (not supplied) to the. > Refer to the illustrations on the following pages for proper wiring connections and choose the correct illustration for your application. > Note: When using Class 2 power limited circuits, (for example, 0-10 VDC dimming connections) remember to keep this wiring separate from high voltage wiring by using separate conduit and the enclosure knockout provided. > Replace lid and secure. 2

WIRING DIAGRAMS for UL 1008 - BCELTS Applications ILLUSTRATION 3 LOCAL SWITCHING MEANS as a BCELTS Device ILLUSTRATION 4 DIMMED RACK as a BCELTS Device for a Dimming Rack *NOTE: Wire gauges for ALL leads terminating at T2 should be #18 AWG. Wire gauges for all other connections should be sized according to total connected lighting load. Ground unit using supplied green lead wire. 3

WIRING DIAGRAMS for UL 1008 - BCELTS Applications ILLUSTRATION 5 DIMMED TO SWITCHED TO TO DIMMED SWITCHED CONTROL as a BCELTS Device with a 3-wire Dimming System ILLUSTRATION 6 0-10 VDC DIMMER TO LEADS TO LEADS WHT (IF PROVIDED) as a BCELTS Device with a 0-10 VDC Dimming System Use knockout provided on enclosure and separate conduit to route the 0-10 VDC dimming control wires (see Note in Step #2 on page 2). *NOTE: Wire gauges for ALL leads terminating at T2 should be #18 AWG. Wire gauges for all other connections should be sized according to total connected lighting load. Ground unit using supplied green lead wire. 4

WIRING DIAGRAMS for UL 924 - SWITCH BYPASS Applications ILLUSTRATION 7 LOCAL SWITCHING MEANS as a Switch Bypass Device ILLUSTRATION 8 DIMMED TO CONTROL SWITCHED TO SWITCHED TO DIMMED as a Switch Bypass Device with a 3-wire Dimming System *NOTE: Wire gauges for ALL leads terminating at T2 should be #18 AWG. Wire gauges for all other connections should be sized according to total connected lighting load. Ground unit using supplied green lead wire. 5

WIRING DIAGRAM for UL 924 - SWITCH BYPASS Applications ILLUSTRATION 9 TO CONNECTIONS (0-10VDC) CONTROL SWITCHED TO SWITCHED TO WHT (IF PROVIDED) TO CONNECTIONS (0-10VDC) as a Switch Bypass Device with a 0-10 VDC Dimming System STEP #3 FOLLOW-UP & QUICK TEST OF THE INSTALLATION > Mark each designated emergency lighting fixture with the warning labels provided (20 labels are provided with each unit). > Apply AC power to all circuits. The green "Normal Power Present" and the red "Emergency Power Available" LED's should be illuminated. > Perform a quick test as described on the unit label to check for proper operation. When the test button is depressed, the green "Normal Power Present" LED should extinguish and the controlled lighting load should illuminate regardless of the local switch position provided emergency power is available (check red LED). > During a quick test using a with a dimming system, the lighting load should illuminate at full lumen levels when the test switch is depressed regardless of the lumen level during normal operation. OPERATION > The entire generator (or central inverter) system, including all designated lighting loads, should be exercised to ensure proper operation (e.g., power up the generator, throw the main automatic transfer switch to the generator position, and check the lighting loads to verify they are operating properly from the generator/central inverter supply). The uses an internal relay contact to control the AC power feeding the lighting load. When the generator (or central inverter) supplies AC power to the lighting fixture, the bypasses the local switching means or dimmer. This ensures the lighting load will be energized at full lumen output during generator (or central inverter) operation regardless of switch position or dim setting. MAINTENANCE No routine maintenance is required to keep the functional. However, it should be checked periodically to ensure that it is working properly. Note: Make sure to disconnect both the normal and emergency panel circuit breakers before servicing.! REFER ANY SERVICING INDICATED BY THESE CHECKS TO QUALIFIED PERSONNEL! 6